Normalized to: Fruitwala, N.
[1]
oai:arXiv.org:2007.06496 [pdf] - 2132084
Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave
Device Arrays
Smith, Jennifer Pearl;
Mazin, Benjamin A.;
Walter, Alex B.;
Daal, Miguel;
Bailey,, J. I.;
Bockstiegel, Clinton;
Zobrist, Nicholas;
Swimmer, Noah;
Steiger, Sarah;
Fruitwala, Neelay
Submitted: 2020-07-13
Superconducting electronics often require high-density microwave
interconnects capable of transporting signals between temperature stages with
minimal loss, cross talk, and heat conduction. We report the design and
fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial
ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner
conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm
thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on
connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick)
soldered to a coplanar wave guide transition board. The 30 cm long cable has 1
dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss
is 0.5 dB more than commercially available superconducting coax likely due to
impedance mismatches caused by manufacturing imperfections in the cable. The
reported cross talk is 30 dB lower than previously developed laminated
NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to
be 20 nW per trace, approximately half the computed load from the smallest
commercially available superconducting coax from CryoCoax
[2]
oai:arXiv.org:1911.06434 [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance
Detectors
Zobrist, Nicholas;
Coiffard, Grégoire;
Bumble, Bruce;
Swimmer, Noah;
Steiger, Sarah;
Daal, Miguel;
Collura, Giulia;
Walter, Alex B.;
Bockstiegel, Clint;
Fruitwala, Neelay;
Lipartito, Isabel;
Mazin, Benjamin A.
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance
Detectors (MKIDs) sensitive to single photons in the optical to near-infrared
range using hafnium as the sensor material. Our test device had a
superconducting transition temperature of 395 mK and a room temperature normal
state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the
device displayed internal quality factors of around 200,000. Similar to the
analysis of MKIDs made from other highly resistive superconductors, we find
that modeling the temperature response of the detector requires an extra
broadening parameter in the superconducting density of states. Finally, we show
that this material and design is compatible with a full-array fabrication
process which resulted in pixels with decay times of about 40 $\mu$s and
resolving powers of ~9 at 800 nm.
[3]
oai:arXiv.org:1908.02775 [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in
the 2020s
Mazin, Benjamin A.;
Bailey, Jeb;
Bartlett, Jo;
Bockstiegel, Clint;
Bumble, Bruce;
Coiffard, Gregoire;
Currie, Thayne;
Daal, Miguel;
Davis, Kristina;
Dodkins, Rupert;
Fruitwala, Neelay;
Jovanovic, Nemanja;
Lipartito, Isabel;
Lozi, Julien;
Males, Jared;
Mawet, Dimitri;
Meeker, Seth;
O'Brien, Kieran;
Rich, Michael;
Smith, Jenny;
Steiger, Sarah;
Swimmer, Noah;
Walter, Alex;
Zobrist, Nick;
Zmuidzinas, Jonas
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are
superconducting photon counting detectors capable of measuring the energy and
arrival time of individual OIR photons without read noise or dark current. In
this whitepaper we will discuss the current status of OIR MKIDs and MKID-based
instruments.
[4]
oai:arXiv.org:1907.03078 [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical
Microwave Kinetic Inductance Detectors
Zobrist, Nicholas;
Eom, Byeong Ho;
Day, Peter;
Mazin, Benjamin A.;
Meeker, Seth R.;
Bumble, Bruce;
LeDuc, Henry G.;
Coiffard, Gérgoire;
Szypryt, Paul;
Fruitwala, Neelay;
Lipartito, Isabel;
Bockstiegel, Clint
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic
Inductance Detector (MKID) can be degraded by noise coming from the primary low
temperature amplifier in the detector's readout system. Until recently, quantum
limited amplifiers have been incompatible with these detectors due to dynamic
range, power, and bandwidth constraints. However, we show that a kinetic
inductance based traveling wave parametric amplifier can be used for this
application and reaches the quantum limit. The total system noise for this
readout scheme was equal to ~2.1 in units of quanta. For incident photons in
the 800 to 1300 nm range, the amplifier increased the average resolving power
of the detector from ~6.7 to 9.3 at which point the resolution becomes limited
by noise on the pulse height of the signal. Noise measurements suggest that a
resolving power of up to 25 is possible if redesigned detectors can remove this
additional noise source.
[5]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[6]
oai:arXiv.org:1710.07318 [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors
for optical to near-IR astronomy
Szypryt, P.;
Meeker, S. R.;
Coiffard, G.;
Fruitwala, N.;
Bumble, B.;
Ulbricht, G.;
Walter, A. B.;
Daal, M.;
Bockstiegel, C.;
Collura, G.;
Zobrist, N.;
Lipartito, I.;
Mazin, B. A.
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave
Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR
Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID
Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive
optics systems with the goal of directly imaging exoplanets in a 800-1400 nm
band. Previous large optical and near-IR MKID arrays were fabricated using
substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays,
however, suffered from severe non-uniformities in the TiN critical temperature,
causing resonances to shift away from their designed values and lowering usable
detector yield. We have begun fabricating DARKNESS and MEC arrays using
platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays
have much higher uniformity than the TiN arrays, resulting in higher pixel
yields, they have demonstrated better spectral resolution than TiN MKIDs of
similar design. PtSi MKIDs also do not display the hot pixel effects seen when
illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1
um.