sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Frolov, E.

Normalized to: Frolov, E.

8 article(s) in total. 316 co-authors, from 1 to 8 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:2004.13355  [pdf] - 2127466
Observation of unusual slow components in electroluminescence signal of two-phase argon detector
Comments: 18 pages, 14 figures, 1 equation. Proceedings paper of the INSTR20 conference
Submitted: 2020-04-28, last modified: 2020-05-08
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter search to record ionization signals in the gas phase induced by particle scattering in the liquid phase (S2 signals). In this work, the EL pulse-shapes in a two-phase argon detector have for the first time been studied systematically in a wide range of reduced electric field, varying from 3 to 9 Td. The pulse-shapes were studied at different readout configurations and spectral ranges: using cryogenic PMTs and SiPMs, with and without a wavelength shifter (WLS), in the VUV and visible range. We observed the fast component and two unusual slow components, with time constants of about 5 $\mu$s and 40 $\mu$s. The unusual characteristic property of slow components was that their contribution and time constants increased with electric field.
[2]  oai:arXiv.org:2004.13296  [pdf] - 2127465
Observation of primary scintillations in the visible range in liquid argon doped with methane
Comments: 10 pages, 6 figures. Presented at Instrumentation for Colliding Beam Physics Conference (INSTR20)
Submitted: 2020-04-28
Neutron veto detector based on liquid scintillator containing hydrogen atoms is an integral part of any underground experiment for dark matter search. So far, a flammable mixture of liquid hydrocarbons was used as a liquid scintillator in such detectors. A safe alternative might be a liquid scintillator based on liquid argon doped with methane. In this work, we have studied the primary scintillations in pure liquid argon and its mixtures with methane, the CH4 content varying from 100 ppm to 5%. The primary scintillations have for the first time been observed in liquid argon doped with methane, in the visible and near infrared range, and their relative light yields have been measured as a function of the CH4 content.
[3]  oai:arXiv.org:2004.02024  [pdf] - 2075899
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
The DarkSide collaboration; Aalseth, C. E.; Abdelhakim, S.; Agnes, P.; Ajaj, R.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Amaudruz, P.; Ameli, F.; Anstey, J.; Antonioli, P.; Arba, M.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Arpaia, P.; Asner, D. M.; Asunskis, A.; Ave, M.; Back, H. O.; Barbaryan, V.; Olmedo, A. Barrado; Batignani, G.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Borisova, E.; Bottino, B.; Boulay, M. G.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carnesecchi, F.; Castellani, A.; Castello, P.; Cavalcante, P.; Cavazza, D.; Cavuoti, S.; Cebrian, S.; Ruiz, J. M. Cela; Celano, B.; Cereseto, R.; Chashin, S.; Cheng, W.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Coccetti, F.; Cocco, V.; Colocci, M.; Vidal, E. Conde; Consiglio, L.; Cossio, F.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; Rolo, M. D. Da Rocha; Dadoun, O.; Daniel, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Falco, A.; De Gruttola, D.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Demontis, P.; De Pasquale, S.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Noto, L.; Di Pietro, G.; Di Stefano, P.; Dionisi, C.; Dolganov, G.; Dordei, F.; Downing, M.; Edalatfar, F.; Empl, A.; Diaz, M. Fernandez; Filip, C.; Fiorillo, G.; Fomenko, K.; Franceschi, A.; Franco, D.; Frolov, E.; Froudakis, G. E.; Funicello, N.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Garbini, M.; Abia, P. Garcia; Fora, D. Gascón; Gendotti, A.; Ghiano, C.; Ghisi, A.; Giampa, P.; Giampaolo, R. A.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gorchakov, O.; Grab, M.; Diaz, R. Graciani; Grassi, M.; Grate, J. W.; Grobov, A.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hackett, B. R.; Hallin, A.; Haranczyk, M.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hubaut, F.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ilyasov, A.; Ippolito, V.; Jillings, C.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Kondo, K.; Kopp, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kugathasan, R.; Kuss, M.; La Commara, M.; La Delfa, L.; Lai, M.; Lebois, M.; Lehnert, B.; Levashko, N.; Li, X.; Liqiang, Q.; Lissia, M.; Lodi, G. U.; Longo, G.; Lussana, R.; Luzzi, L.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Manecki, S.; Mapelli, L.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Marinelli, M.; Marras, D.; Martínez, M.; Rojas, A. D. Martinez; Mascia, M.; Mason, J.; Masoni, A.; McDonald, A. B.; Messina, A.; Miletic, T.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Morrocchi, M.; Mroz, T.; Mu, W.; Muratova, V. N.; Murphy, S.; Muscas, C.; Musico, P.; Nania, R.; Napolitano, T.; Agasson, A. Navrer; Nessi, M.; Nikulin, I.; Nosov, V.; Nowak, J. A.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Peeters, S.; Pegoraro, P. A.; Pelczar, K.; Pellegrini, L. A.; Pellegrino, C.; Pelliccia, N.; Perotti, F.; Pesudo, V.; Picciau, E.; Pietropaolo, F.; Pocar, A.; Pollmann, T. R.; Portaluppi, D.; Poudel, S. S.; Pralavorio, P.; Price, D.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Regenfus, C.; Renshaw, A. L.; Rescia, S.; Rescigno, M.; Retiere, F.; Rignanese, L. P.; Ripoli, C.; Rivetti, A.; Rode, J.; Romani, A.; Romero, L.; Rossi, N.; Rubbia, A.; Sala, P.; Salatino, P.; Samoylov, O.; García, E. Sánchez; Sandford, E.; Sanfilippo, S.; Sant, M.; Santone, D.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Siddhanta, S.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Stainforth, R.; Steri, A.; Stracka, S.; Strickland, V.; Suffritti, G. B.; Sulis, S.; Suvorov, Y.; Szelc, A. M.; Tartaglia, R.; Testera, G.; Thorpe, T.; Tonazzo, A.; Tosi, A.; Tuveri, M.; Unzhakov, E. V.; Usai, G.; Vacca, A.; Vázquez-Jáuregui, E.; Viant, T.; Viel, S.; Villa, F.; Vishneva, A.; Vogelaar, R. B.; Wahl, J.; Walding, J. J.; Wang, H.; Wang, Y.; Westerdale, S.; Wheadon, R. J.; Williams, R.; Wilson, J.; Wojcik, Marcin; Wojcik, Mariusz; Wu, S.; Xiao, X.; Yang, C.; Ye, Z.; Zuffa, M.; Zuzel, G.
Comments: 25 pages, 22 figures, 3 tables
Submitted: 2020-04-04
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter search to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition to it, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) range. The first is due to bremsstrahlung of electrons scattered on neutral atoms (so-called neutral bremsstrahlung, NBrS). The second, responsible for electron avalanche scintillations in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a SiPM matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillations effects. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter search. It should be emphasized that this is the first practical application of the NBrS effect in detection science.
[4]  oai:arXiv.org:1909.00619  [pdf] - 1953832
Electron transport and electric field simulations in two-phase detectors with THGEM electrodes
Comments: 7 pages, 11 figures, 1 table
Submitted: 2019-09-02
One of the main features of two-phase detectors with electroluminescence (EL) gap being developed in our laboratory for dark matter search is the extensive use of THGEMs (Thick Gas Electron Multipliers). In various versions of the detector, the THGEMs are used as electrodes in the gas and liquid phases to form the drift, electron emission and EL regions, as well as for avalanche amplification of a signal in the gas phase. In this work the simulations of the electric field and electron transport through such THGEM electrodes were performed. In the liquid phase, these simulations allowed to determine the optimal parameters, such as the hole diameter of THGEM and applied voltage across it, that can provide effective transmission of the electrons from the drift region to that of the EL gap. In the gas phase, the effect of the THGHEM voltage on the electric field uniformity in the EL gap was studied.
[5]  oai:arXiv.org:1905.05502  [pdf] - 2052567
Neutral bremsstrahlung in two-phase argon electroluminescence: further studies and possible applications
Comments: 4 pages, 5 figures, presented at VCI2019 conference, to be published in NIM A
Submitted: 2019-05-14
We further study the effect of neutral bremsstrahlung (NBrS) in two-phase argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield due to NBrS effect, in the visible and NIR range, was remeasured in pure gaseous argon in the two-phase mode, using a two-phase detector with EL gap read out directly by cryogenic PMTs and SiPMs. Possible applications of the NBrS effect in detection science are discussed, including those in two-phase dark matter detectors.
[6]  oai:arXiv.org:1803.05329  [pdf] - 1712914
Revealing neutral bremsstrahlung in two-phase argon electroluminescence
Comments: 14 pages, 21 figures. Version3: new several paragraphs and references and a new figure added
Submitted: 2018-03-13, last modified: 2018-06-20
Proportional electroluminescence (EL) in noble gases has long been used in two-phase detectors for dark matter search, to record ionization signals induced by particle scattering in the noble-gas liquid (S2 signals). Until recently, it was believed that proportional electroluminescence was fully due to VUV emission of noble gas excimers produced in atomic collisions with excited atoms, the latter being in turn produced by drifting electrons. In this work we consider an additional mechanism of proportional electroluminescence, namely that of bremsstrahlung of drifting electrons scattered on neutral atoms (so-called neutral bremsstrahlung); it is systemically studied here both theoretically and experimentally. In particular, the absolute EL yield has for the first time been measured in pure gaseous argon in the two-phase mode, using a dedicated two-phase detector with EL gap optically read out by cryogenic PMTs and SiPMs. We show that the neutral bremsstrahlung effect can explain two intriguing observations in EL radiation: that of the substantial contribution of the non-VUV spectral component, extending from the UV to NIR, and that of the photon emission at lower electric fields, below the Ar excitation threshold. Possible applications of neutral bremsstrahlung effect in two-phase dark matter detectors are discussed.
[7]  oai:arXiv.org:1705.05101  [pdf] - 1583416
Further studies of proportional electroluminescence in two-phase argon
Comments: 12 pages, 7 figures, 1 table. Presented at Instrumentation for Colliding Beam Physics Conference (INSTR17). To be published in JINST
Submitted: 2017-05-15
The study of proportional electroluminescence in two-phase argon is relevant in the field of noble-gas liquid detectors for dark matter search and low-energy neutrino experiments. In this work, we continued to study proportional electroluminescence (EL) in two-phase argon doped with a minor (9 ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We confirmed the effect of enhancement of the EL yield, as well as the presence of non-VUV component in addition to that of VUV, in proportional electroluminescence in two-phase Ar. On the other hand, the contribution of non-VUV component determined here within the model of N2 emission in the UV, turned out to be insufficient to explain the EL yield enhancement effect. Accordingly, the problem of proportional electroluminescence in two-phase Ar remains unresolved.
[8]  oai:arXiv.org:1705.01250  [pdf] - 1583058
Study of cryogenic photomultiplier tubes for the future two-phase cryogenic avalanche detector
Comments: Submitted to the Proceedings of the Instrumentation for Colliding Beam Physics INSTR17 Conference, to be published in JINST
Submitted: 2017-05-03
We report the results of a characterization study of several types of cryogenic photomultipliers manufactured by Hamamatsu Photonics and intended for operation in liquid Ar conditions, namely: compact 2-inch R6041-506MOD tubes, 3-inch R11065-10 and R11065-MOD tubes for operation in liquid Ar and 3-inch R11410-20 tubes originally designed for operation in liquid Xe. These types of PMT are proposed for installation into the future two-phase cryogenic avalanche detector that is developed in the Laboratory of Cosmology and Particle Physics of the Novosibirsk State University jointly with the Budker Institute of Nuclear Physics. Eight R11065 PMTs and seven R11410-20 tubes were tested and all demonstrated excellent performance in liquid Ar in terms of gain and relative single electron efficiency. All 3-inch PMTs showed a maximal gain in liquid Ar above 5x10^6 and relative single electron efficiency higher than 95%. Compact R6041-506MOD tubes have dynode system different from that of the 3-inch photomultipliers and thus their single electron energy resolution and relative efficiency is much worse than that of 3-inch tubes. From 21 2-inch PMTs only 12 tubes were selected with acceptable, i.e. higher than 75%, relative single electron efficiency and the maximal gain higher than 5x10^6. However, these PMTs are very attractive because they are the only compact type of tubes that can operate in liquid Ar.