Normalized to: Freiwald, J.
[1]
oai:arXiv.org:1506.06045 [pdf] - 1219534
Data compression for the First G-APD Cherenkov Telescope
Ahnen, M. L.;
Balbo, M.;
Bergmann, M.;
Biland, A.;
Bretz, T.;
Buß, J.;
Dorner, D.;
Einecke, S.;
Freiwald, J.;
Hempfling, C.;
Hildebrand, D.;
Hughes, G.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meier, K.;
Mueller, S.;
Neise, D.;
Neronov, A.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Rhode, W.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Toscano, S.;
Vogler, P.;
Walter, R.;
Wilbert, A.
Submitted: 2015-06-19
The First Geiger-mode Avalanche photodiode (G-APD) Cherenkov Telescope (FACT)
has been operating on the Canary island of La Palma since October 2011.
Operations were automated so that the system can be operated remotely. Manual
interaction is required only when the observation schedule is modified due to
weather conditions or in case of unexpected events such as a mechanical
failure. Automatic operations enabled high data taking efficiency, which
resulted in up to two terabytes of FITS files being recorded nightly and
transferred from La Palma to the FACT archive at ISDC in Switzerland. Since
long term storage of hundreds of terabytes of observations data is costly, data
compression is mandatory. This paper discusses the design choices that were
made to increase the compression ratio and speed of writing of the data with
respect to existing compression algorithms.
Following a more detailed motivation, the FACT compression algorithm along
with the associated I/O layer is discussed. Eventually, the performances of the
algorithm is compared to other approaches.
[2]
oai:arXiv.org:1502.02582 [pdf] - 932585
FACT - Monitoring Blazars at Very High Energies
Dorner, D.;
Ahnen, M. L.;
Bergmann, M.;
Biland, A.;
Balbo, M.;
Bretz, T.;
Buss, J.;
Einecke, S.;
Freiwald, J.;
Hempfling, C.;
Hildebrand, D.;
Hughes, G.;
Lustermann, W.;
Mannheim, K.;
Meier, K.;
Mueller, S.;
Neise, D.;
Neronov, A.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Rhode, W.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Toscano, S.;
Vogler, P.;
Walter, R.;
Wilbert, A.
Submitted: 2015-02-09
The First G-APD Cherenkov Telescope (FACT) was built on the Canary Island of
La Palma in October 2011 as a proof of principle for silicon based photosensors
in Cherenkov Astronomy. The scientific goal of the project is to study the
variability of active galatic nuclei (AGN) at TeV energies. Observing a small
sample of TeV blazars whenever possible, an unbiased data sample is collected.
This allows to study the variability of the selected objects on timescales from
hours to years. Results from the first three years of monitoring will be
presented. To provide quick flare alerts to the community and trigger
multi-wavelength observations, a quick look analysis has been installed on-site
providing results publicly online within the same night. In summer 2014,
several flare alerts were issued. Results of the quick look analysis are
summarized.
[3]
oai:arXiv.org:1403.5747 [pdf] - 903425
Calibration and performance of the photon sensor response of FACT -- The
First G-APD Cherenkov telescope
Biland, A.;
Bretz, T.;
Buß, J.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Freiwald, J.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hempfling, C.;
Hildebrand, D.;
Hughes, G.;
Horisberger, U.;
Knoetig, M. L.;
Krähenbühl, T.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meier, K.;
Mueller, S.;
Neise, D.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Rhode, W.;
Röser, U.;
Stucki, J. -P.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Vogler, P.;
Walter, R.;
Weitzel, Q.
Submitted: 2014-03-23, last modified: 2014-07-30
The First G-APD Cherenkov Telescope (FACT) is the first in-operation test of
the performance of silicon photo detectors in Cherenkov Astronomy. For more
than two years it is operated on La Palma, Canary Islands (Spain), for the
purpose of long-term monitoring of astrophysical sources. For this, the
performance of the photo detectors is crucial and therefore has been studied in
great detail. Special care has been taken for their temperature and voltage
dependence implementing a correction method to keep their properties stable.
Several measurements have been carried out to monitor the performance. The
measurements and their results are shown, demonstrating the stability of the
gain below the percent level. The resulting stability of the whole system is
discussed, nicely demonstrating that silicon photo detectors are perfectly
suited for the usage in Cherenkov telescopes, especially for long-term
monitoring purpose.
[4]
oai:arXiv.org:1407.1988 [pdf] - 1516230
FACT -- Operation of the First G-APD Cherenkov Telescope
Bretz, T.;
Biland, A.;
Buß, J.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Freiwald, J.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hempfling, C.;
Hildebrand, D.;
Hughes, G.;
Horisberger, U.;
Knoetig, M. L.;
Krähenbühl, T.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meier, K.;
Mueller, S.;
Neise, D.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Rhode, W.;
Röser, U.;
Stucki, J. -P.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Vogler, P.;
Walter, R.;
Weitzel, Q.
Submitted: 2014-07-08
Since more than two years, the First G-APD Cherenkov Telescope (FACT) is
operating successfully at the Canary Island of La Palma. Apart from its purpose
to serve as a monitoring facility for the brightest TeV blazars, it was built
as a major step to establish solid state photon counters as detectors in
Cherenkov astronomy.
The camera of the First G-APD Cherenkov Telesope comprises 1440 Geiger-mode
avalanche photo diodes (G-APD aka. MPPC or SiPM) for photon detection. Since
properties as the gain of G-APDs depend on temperature and the applied voltage,
a real-time feedback system has been developed and implemented. To correct for
the change introduced by temperature, several sensors have been placed close to
the photon detectors. Their read out is used to calculate a corresponding
voltage offset. In addition to temperature changes, changing current introduces
a voltage drop in the supporting resistor network. To correct changes in the
voltage drop introduced by varying photon flux from the night-sky background,
the current is measured and the voltage drop calculated. To check the stability
of the G-APD properties, dark count spectra with high statistics have been
taken under different environmental conditions and been evaluated.
The maximum data rate delivered by the camera is about 240 MB/s. The recorded
data, which can exceed 1 TB in a moonless night, is compressed in real-time
with a proprietary loss-less algorithm. The performance is better than gzip by
almost a factor of two in compression ratio and speed. In total, two to three
CPU cores are needed for data taking. In parallel, a quick-look analysis of the
recently recorded data is executed on a second machine. Its result is publicly
available within a few minutes after the data were taken.
[...]