Normalized to: Fraenkle, F.
[1]
oai:arXiv.org:1808.09168 [pdf] - 1740186
Impact of a cryogenic baffle system on the suppression of radon-induced
background in the KATRIN Pre-Spectrometer
Goerhardt, S.;
Bonn, J.;
Bornschein, L.;
Drexlin, G.;
Fraenkle, F. M.;
Gumbsheimer, R.;
Mertens, S.;
Mueller, F. R.;
Thuemmler, T.;
Wandkowsky, N.;
Weinheimer, C.;
Wolf, J.
Submitted: 2018-08-28
The KATRIN experiment will determine the effective electron anti-neutrino
mass with a sensitivity of 200 meV/c$^2$ at 90% CL. The energy analysis of
tritium $\beta$-decay electrons will be performed by a tandem setup of
electrostatic retarding spectrometers which have to be operated at very low
background levels of $<10^{-2}$ counts per second. This benchmark rate can be
exceeded by background processes resulting from the emanation of single
$^{219,220}$Rn atoms from the inner spectrometer surface and an array of
non-evaporable getter strips used as main vacuum pump. Here we report on a the
impact of a cryogenic technique to reduce this radon-induced background in
electrostatic spectrometers. It is based on installing a liquid nitrogen cooled
copper baffle in the spectrometer pump port to block the direct line of sight
between the getter pump, which is the main source of $^{219}$Rn, and the
sensitive flux tube volume. This cold surface traps a large fraction of
emanated radon atoms in a region outside of the active flux tube, preventing
background there. We outline important baffle design criteria to maximize the
efficiency for the adsorption of radon atoms, describe the baffle implemented
at the KATIRN Pre-Spectrometer test set-up, and report on its initial
performance in suppressing radon-induced background.
[2]
oai:arXiv.org:1602.04816 [pdf] - 1530478
A White Paper on keV Sterile Neutrino Dark Matter
Adhikari, R.;
Agostini, M.;
Ky, N. Anh;
Araki, T.;
Archidiacono, M.;
Bahr, M.;
Baur, J.;
Behrens, J.;
Bezrukov, F.;
Dev, P. S. Bhupal;
Borah, D.;
Boyarsky, A.;
de Gouvea, A.;
Pires, C. A. de S.;
de Vega, H. J.;
Dias, A. G.;
Di Bari, P.;
Djurcic, Z.;
Dolde, K.;
Dorrer, H.;
Durero, M.;
Dragoun, O.;
Drewes, M.;
Drexlin, G.;
Düllmann, Ch. E.;
Eberhardt, K.;
Eliseev, S.;
Enss, C.;
Evans, N. W.;
Faessler, A.;
Filianin, P.;
Fischer, V.;
Fleischmann, A.;
Formaggio, J. A.;
Franse, J.;
Fraenkle, F. M.;
Frenk, C. S.;
Fuller, G.;
Gastaldo, L.;
Garzilli, A.;
Giunti, C.;
Glück, F.;
Goodman, M. C.;
Gonzalez-Garcia, M. C.;
Gorbunov, D.;
Hamann, J.;
Hannen, V.;
Hannestad, S.;
Hansen, S. H.;
Hassel, C.;
Heeck, J.;
Hofmann, F.;
Houdy, T.;
Huber, A.;
Iakubovskyi, D.;
Ianni, A.;
Ibarra, A.;
Jacobsson, R.;
Jeltema, T.;
Jochum, J.;
Kempf, S.;
Kieck, T.;
Korzeczek, M.;
Kornoukhov, V.;
Lachenmaier, T.;
Laine, M.;
Langacker, P.;
Lasserre, T.;
Lesgourgues, J.;
Lhuillier, D.;
Li, Y. F.;
Liao, W.;
Long, A. W.;
Maltoni, M.;
Mangano, G.;
Mavromatos, N. E.;
Menci, N.;
Merle, A.;
Mertens, S.;
Mirizzi, A.;
Monreal, B.;
Nozik, A.;
Neronov, A.;
Niro, V.;
Novikov, Y.;
Oberauer, L.;
Otten, E.;
Palanque-Delabrouille, N.;
Pallavicini, M.;
Pantuev, V. S.;
Papastergis, E.;
Parke, S.;
Pascoli, S.;
Pastor, S.;
Patwardhan, A.;
Pilaftsis, A.;
Radford, D. C.;
Ranitzsch, P. C. -O.;
Rest, O.;
Robinson, D. J.;
da Silva, P. S. Rodrigues;
Ruchayskiy, O.;
Sanchez, N. G.;
Sasaki, M.;
Saviano, N.;
Schneider, A.;
Schneider, F.;
Schwetz, T.;
Schönert, S.;
Scholl, S.;
Shankar, F.;
Shrock, R.;
Steinbrink, N.;
Strigari, L.;
Suekane, F.;
Suerfu, B.;
Takahashi, R.;
Van, N. Thi Hong;
Tkachev, I.;
Totzauer, M.;
Tsai, Y.;
Tully, C. G.;
Valerius, K.;
Valle, J. W. F.;
Venos, D.;
Viel, M.;
Vivier, M.;
Wang, M. Y.;
Weinheimer, C.;
Wendt, K.;
Winslow, L.;
Wolf, J.;
Wurm, M.;
Xing, Z.;
Zhou, S.;
Zuber, K.
Submitted: 2016-02-15, last modified: 2017-02-09
We present a comprehensive review of keV-scale sterile neutrino Dark Matter,
collecting views and insights from all disciplines involved - cosmology,
astrophysics, nuclear, and particle physics - in each case viewed from both
theoretical and experimental/observational perspectives. After reviewing the
role of active neutrinos in particle physics, astrophysics, and cosmology, we
focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we
first review the physics motivation for sterile neutrino Dark Matter, based on
challenges and tensions in purely cold Dark Matter scenarios. We then round out
the discussion by critically summarizing all known constraints on sterile
neutrino Dark Matter arising from astrophysical observations, laboratory
experiments, and theoretical considerations. In this context, we provide a
balanced discourse on the possibly positive signal from X-ray observations.
Another focus of the paper concerns the construction of particle physics
models, aiming to explain how sterile neutrinos of keV-scale masses could arise
in concrete settings beyond the Standard Model of elementary particle physics.
The paper ends with an extensive review of current and future astrophysical and
laboratory searches, highlighting new ideas and their experimental challenges,
as well as future perspectives for the discovery of sterile neutrinos.
[3]
oai:arXiv.org:1403.0475 [pdf] - 797476
A search for bremsstrahlung solar axions using the Majorana
low-background BEGe detector at Kimballton (MALBEK)
Abgrall, N.;
Aguayo, E.;
Avignone, F. T.;
Barabash, A. S.;
Bertrand, F. E.;
Boswell, M.;
Brudanin, V.;
Busch, M.;
Caldwell, A. S.;
Chan, Y-D.;
Christofferson, C. D.;
Combs, D. C.;
Cooper, R. J.;
Creswick, R. J.;
Detwiler, J. A.;
Doe, P. J.;
Efremenko, Yu.;
Egorov, V.;
Elliott, S. R.;
Fast, J. E.;
Finnerty, P.;
Fraenkle, F. M.;
Galindo-Uribarri, A.;
Giovanetti, G. K.;
Goett, J.;
Green, M. P.;
Gruszko, J.;
Guiseppe, V. E.;
Gusev, K.;
Hegai, A.;
Henning, R.;
Hoppe, E. W.;
Howard, S.;
Howe, M. A.;
Keeter, K. J.;
Kidd, M. F.;
Knecht, A.;
Kochetov, O.;
Konovalov, S. I.;
Kouzes, R. T.;
LaFerriere, B. D.;
Leon, J.;
Leviner, L. E.;
Loach, J. C.;
MacMullin, J.;
MacMullin, S.;
Marino, M. G.;
Martin, R. D.;
Mertens, S.;
Orrell, J. L.;
O'Shaughnessy, C.;
Overman, N. R.;
Phillips, D. G.;
Poon, A. W. P.;
Pushkin, K.;
Radford, D. C.;
Rielage, K.;
Robertson, R. G. H.;
Ronquest, M. C.;
Schubert, A. G.;
Shanks, B.;
Shirchenko, M.;
Snavely, K. J.;
Snyder, N.;
Steele, D.;
Suriano, A. M.;
Thompson, J.;
Timkin, V.;
Varner, R. L.;
Vasilyev, S.;
Vetter, K.;
Vorren, K.;
White, B. R.;
Wilkerson, J. F.;
Xu, W.;
Yakushev, E.;
Young, A. R.;
Yu, C. H.;
Yumatov, V.
Submitted: 2014-03-03, last modified: 2014-03-17
A low-background, high-purity germanium detector has been used to search for
evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound
of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ
model axions to electrons. The prospects for the sensitivity of the Majorana
Demonstrator array of point-contact germanium detectors to solar axions are
discussed in the context of the model-independent annual modulation due to the
seasonal variation of the earth-sun distance.