Normalized to: Fouque, N.
[4]
oai:arXiv.org:1508.07120 [pdf] - 1938080
Silicon Photomultiplier Research and Development Studies for the Large
Size Telescope of the Cherenkov Telescope Array
Rando, Riccardo;
Corti, Daniele;
Dazzi, Francesco;
De Angelis, Alessandro;
Dettlaff, Antonios;
Dorner, Daniela;
Fink, David;
Fouque, Nadia;
Grundner, Felix;
Haberer, Werner;
Hahn, Alexander;
Hermel, Richard;
Korpar, Samo;
Mezek, Gašper Kukec;
Maier, Ronald;
Manea, Christian;
Mariotti, Mosè;
Mazin, Daniel;
Mehrez, Fatima;
Mirzoyan, Razmik;
Podkladkin, Sergey;
Reichardt, Ignasi;
Rhode, Wolfgang;
Rosier, Sylvie;
Schultz, Cornelia;
Stella, Carlo;
Teshima, Masahiro;
Wetteskind, Holger;
Zavrtanik, Marko
Submitted: 2015-08-28
The Cherenkov Telescope Array (CTA) is the the next generation facility of
imaging atmospheric Cherenkov telescopes; two sites will cover both
hemispheres. CTA will reach unprecedented sensitivity, energy and angular
resolution in very-high-energy gamma-ray astronomy. Each CTA array will include
four Large Size Telescopes (LSTs), designed to cover the low-energy range of
the CTA sensitivity ($\sim$20 GeV to 200 GeV). In the baseline LST design, the
focal-plane camera will be instrumented with 265 photodetector clusters; each
will include seven photomultiplier tubes (PMTs), with an entrance window of 1.5
inches in diameter. The PMT design is based on mature and reliable technology.
Recently, silicon photomultipliers (SiPMs) are emerging as a competitor.
Currently, SiPMs have advantages (e.g. lower operating voltage and tolerance to
high illumination levels) and disadvantages (e.g. higher capacitance and cross
talk rates), but this technology is still young and rapidly evolving. SiPM
technology has a strong potential to become superior to the PMT one in terms of
photon detection efficiency and price per square mm of detector area. While the
advantage of SiPMs has been proven for high-density, small size cameras, it is
yet to be demonstrated for large area cameras such as the one of the LST. We
are working to develop a SiPM-based module for the LST camera, in view of a
possible camera upgrade. We will describe the solutions we are exploring in
order to balance a competitive performance with a minimal impact on the overall
LST camera design.
[5]
oai:arXiv.org:1508.06555 [pdf] - 1267007
NectarCAM : a camera for the medium size telescopes of the Cherenkov
Telescope Array
Glicenstein, J-F.;
Abril, O.;
Barrio, J-A.;
Blanch~Bigas, O.;
Bolmont, J.;
Bouyjou, F.;
Brun, P.;
Chabanne, E.;
Champion, C.;
Colonges, S.;
Corona, P.;
Delagnes, E.;
Delgado, C.;
Ginzov, C. Diaz;
Durand, D.;
Ernenwein, J-P.;
Fegan, S.;
Ferreira, O.;
Fesquet, M.;
Fiasson, A.;
Fontaine, G.;
Fouque, N.;
Gascon, D.;
Giebels, B.;
Henault, F.;
Hermel, R.;
Hoffmann, D.;
Horan, D.;
Houles, J.;
Jean, P.;
Jocou, L.;
Karkar, S.;
Knoedlseder, J.;
Kossakowski, R.;
Lamanna, G.;
LeFlour, T.;
Lenain, J-P.;
Leveque, A.;
Louis, F.;
Martinez, G.;
Moudden, Y.;
Moulin, E.;
Nayman, P.;
Nunio, F.;
Olive, J-F.;
Panazol, J-L.;
Pavy, S.;
Petrucci, P-O.;
Pierre, E.;
Prast, J.;
Punch, M.;
Ramon, P.;
Rateau, S.;
Ravel, T.;
Rosier-Lees, S.;
Sanuy, A.;
Shayduk, M.;
Sizun, P-Y.;
Sulanke, K-H.;
Tavernet, J-P.;
Tejedor~Alvarez, L-A.;
Toussenel, F.;
Vasileiadis, G.;
Voisin, V.;
Waegebert, V.;
Wischnewski, R.
Submitted: 2015-08-26
NectarCAM is a camera proposed for the medium-sized telescopes of the
Cherenkov Telescope Array (CTA) covering the central energy range of ~100 GeV
to ~30 TeV. It has a modular design and is based on the NECTAr chip, at the
heart of which is a GHz sampling Switched Capacitor Array and a 12-bit Analog
to Digital converter. The camera will be equipped with 265 7-photomultiplier
modules, covering a field of view of 8 degrees. Each module includes the
photomultiplier bases, high voltage supply, pre-amplifier, trigger, readout and
Ethernet transceiver. The recorded events last between a few nanoseconds and
tens of nanoseconds. The camera trigger will be flexible so as to minimize the
read-out dead-time of the NECTAr chips. NectarCAM is designed to sustain a data
rate of more than 4 kHz with less than 5\% dead time. The camera concept, the
design and tests of the various subcomponents and results of thermal and
electrical prototypes are presented. The design includes the mechanical
structure, cooling of the electronics, read-out, clock distribution, slow
control, data-acquisition, triggering, monitoring and services.
[7]
oai:arXiv.org:1307.4565 [pdf] - 1937883
The Cherenkov Telescope Array Large Size Telescope
Ambrosi, G.;
Awane, Y.;
Baba, H.;
Bamba, A.;
Barceló, M.;
de Almeida, U. Barres;
Barrio, J. A.;
Bigas, O. Blanch;
Boix, J.;
Brunetti, L.;
Carmona, E.;
Chabanne, E.;
Chikawa, M.;
Colin, P.;
Conteras, J. L.;
Cortina, J.;
Dazzi, F.;
Deangelis, A.;
Deleglise, G.;
Delgado, C.;
Díaz, C.;
Dubois, F.;
Fiasson, A.;
Fink, D.;
Fouque, N.;
Freixas, L.;
Fruck, C.;
Gadola, A.;
García, R.;
Gascon, D.;
Geffroy, N.;
Giglietto, N.;
Giordano, F.;
Grañena, F.;
Gunji, S.;
Hagiwara, R.;
Hamer, N.;
Hanabata, Y.;
Hassan, T.;
Hatanaka, K.;
Haubold, T.;
Hayashida, M.;
Hermel, R.;
Herranz, D.;
Hirotani, K.;
Inoue, S.;
Inoue, Y.;
Ioka, K.;
Jablonski, C.;
Kagaya, M.;
Katagiri, H.;
Kishimoto, T.;
Kodani, K.;
Kohri, K.;
Konno, Y.;
Koyama, S.;
Kubo, H.;
Kushida, J.;
Lamanna, G.;
Flour, T. Le;
López-Moya, M.;
López, R.;
Lorenz, E.;
Majumdar, P.;
Manalaysay, A.;
Mariotti, M.;
Martínez, G.;
Martínez, M.;
Mazin, D.;
Miranda, J. M.;
Mirzoyan, R.;
Monteiro, I.;
Moralejo, A.;
Murase, K.;
Nagataki, S.;
Nakajima, D.;
Nakamori, T.;
Nishijima, K.;
Noda, K.;
Nozato, A.;
Ohira, Y.;
Ohishi, M.;
Ohoka, H.;
Okumura, A.;
Orito, R.;
Panazol, J. L.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Pauletta, G.;
Podkladkin, S.;
Prast, J.;
Rando, R.;
Reimann, O.;
Ribó, M.;
Rosier-Lees, S.;
Saito, K.;
Saito, T.;
Saito, Y.;
Sakaki, N.;
Sakonaka, R.;
Sanuy, A.;
Sasaki, H.;
Sawada, M.;
Scalzotto, V.;
Schultz, S.;
Schweizer, T.;
Shibata, T.;
Shu, S.;
Sieiro, J.;
Stamatescu, V.;
Steiner, S.;
Straumann, U.;
Sugawara, R.;
Tajima, H.;
Takami, H.;
Tanaka, S.;
Tanaka, M.;
Tejedor, L. A.;
Terada, Y.;
Teshima, M.;
Totani, T.;
Ueno, H.;
Umehara, K.;
Vollhardt, A.;
Wagner, R.;
Wetteskind, H.;
Yamamoto, T.;
Yamazaki, R.;
Yoshida, A.;
Yoshida, T.;
Yoshikoshi, T.
Submitted: 2013-07-17
The two arrays of the Very High Energy gamma-ray observatory Cherenkov
Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with
a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA
to achieve a low-energy threshold of 20 GeV, which is critical for important
studies in astrophysics, astroparticle physics and cosmology. This work
presents the key specifications and performance of the current LST design in
the light of the CTA scientific objectives.
[8]
oai:arXiv.org:1307.4545 [pdf] - 1941894
The NectarCAM camera project
Glicenstein, J-F.;
Barcelo, M.;
Barrio, J-A.;
Blanch, O.;
Boix, J.;
Bolmont, J.;
Boutonnet, C.;
Cazaux, S.;
Chabanne, E.;
Champion, C.;
Chateau, F.;
Colonges, S.;
Corona, P.;
Couturier, S.;
Courty, B.;
Delagnes, E.;
Delgado, C.;
Ernenwein, J-P.;
Fegan, S.;
Ferreira, O.;
Fesquet, M.;
Fontaine, G.;
Fouque, N.;
Henault, F.;
Gascón, D.;
Herranz, D.;
Hermel, R.;
Hoffmann, D.;
Houles, J.;
Karkar, S.;
Khelifi, B.;
Knödlseder, J.;
Martinez, G.;
Lacombe, K.;
Lamanna, G.;
LeFlour, T.;
Lopez-Coto, R.;
Louis, F.;
Mathieu, A.;
Moulin, E.;
Nayman, P.;
Nunio, F.;
Olive, J-F.;
Panazol, J-L.;
Petrucci, P-O.;
Punch, M.;
Prast, J.;
Ramon, P.;
Riallot, M.;
Ribó, M.;
Rosier-Lees, S.;
Sanuy, A.;
Siero, J.;
Tavernet, J-P.;
Tejedor, L. A.;
Toussenel, F.;
Vasileiadis, G.;
Voisin, V.;
Waegebert, V.;
Zurbach, C.
Submitted: 2013-07-17
In the framework of the next generation of Cherenkov telescopes, the
Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium
size telescopes covering the central energy range of 100 GeV to 30 TeV.
NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view,
FoV) in order to image atmospheric Cherenkov showers by measuring the charge
deposited within a few nanoseconds time-window. It will have additional
features like the capacity to record the full waveform with GHz sampling for
every pixel and to measure event times with nanosecond accuracy. An array of a
few tens of medium size telescopes, equipped with NectarCAMs, will achieve up
to a factor of ten improvement in sensitivity over existing instruments in the
energy range of 100 GeV to 10 TeV. The camera is made of roughly 250
independent read-out modules, each composed of seven photo-multipliers, with
their associated high voltage base and control, a read-out board and a
multi-service backplane board. The read-out boards use NECTAr (New Electronics
for the Cherenkov Telescope Array) ASICs which have the dual functionality of
analogue memories and Analogue to Digital Converter (ADC). The camera trigger
to be used will be flexible so as to minimize the read-out dead-time of the
NECTAr chips. We present the camera concept and the design and tests of the
various subcomponents. The design includes the mechanical parts, the cooling of
the electronics, the readout, the data acquisition, the trigger, the monitoring
and services.
[9]
oai:arXiv.org:astro-ph/0010242 [pdf] - 387034
The AMS-01 Aerogel Threshold Cherenkov counter
Barancourt, D.;
Barao, F.;
Barbier, G.;
Barreira, G.;
Buenerd, M.;
Castellini, G.;
Choumilov, E.;
Favier, J.;
Fouque, N.;
Gougas, A.;
Hermel, V.;
Kossakowski, R.;
Laborie, G.;
Laurenti, G.;
Lee, S. -C.;
Mayet, F.;
Meillon, B.;
Oyang, Y. -T.;
Plyaskin, V.;
Pojidaev, V.;
Rossin, C.;
Santos, D.;
Vezzu, F.;
Vialle, J. P.
Submitted: 2000-10-12
The Alpha Magnetic Spectrometer in a precursor version (AMS-01), was flown in
June 1998 on a 51.6 degrees orbit and at altitudes ranging between 320 and 390
km, on board of the space shuttle Discovery (flight STS-91). AMS-01 included an
Aerogel Threshold Cherenkov counter (ATC) to separate antiprotons from
electrons and positrons from protons, for momenta below 3.5 GeV/c. This paper
presents a description of the ATC counter and reports on its performances
during the flight STS-91.