Normalized to: Fouché, M.
[1]
oai:arXiv.org:2007.06470 [pdf] - 2132079
A comparison of g(1)(\tau), g(3/2)(\tau), and g(2)(\tau), for radiation
from harmonic oscillators in Brownian motion with coherent background
Submitted: 2020-07-13
We compare the field-field g(1)(\tau), intensity-field g(3/2)(\tau), and
intensity-intensity g(2)(\tau) correlation functions for models that are of
relevance in astrophysics. We obtain expressions for the general case of a
chaotic radiation, where the amplitude is Rician based on a model with an
ensemble of harmonic oscillators in Brownian motion. We obtain the signal to
noise ratios for two methods of measurement. The intensity-field correlation
function signal to noise ratio scales with the first power of |g(1)(\tau)|.
This is in contrast with the well-established result of g(2)(\tau) which goes
as the square of |g(1)(\tau)|.
[2]
oai:arXiv.org:1910.08366 [pdf] - 2056860
Intensity interferometry of P Cygni in the H$\alpha$ emission line:
towards distance calibration of LBV supergiant stars
Rivet, J. -P.;
Siciak, A.;
de Almeida, E. S. G.;
Vakili, F.;
de Souza, A. Domiciano;
Fouché, M.;
Lai, O.;
Vernet, D.;
Kaiser, R.;
Guerin, W.
Submitted: 2019-10-18, last modified: 2020-03-02
We present intensity interferometry of the luminous blue variable P Cyg in
the light of its H$\alpha$ emission performed with 1\,m-class telescopes. We
compare the measured visibility points to synthesized interferometric data
based on the CMFGEN physical modeling of a high-resolution spectrum of P Cyg
recorded almost simultaneously with our interferometry data. Tuning the stellar
parameters of P Cyg and its H$\alpha$ linear diameter we estimate the distance
of P Cyg as $1.56\pm0.25$~kpc, which is compatible within $1\sigma$ with
$1.36\pm0.24$~kpc reported by the Gaia DR2 catalogue of parallaxes recently
published. Both values are significantly smaller than the canonic value of
$1.80\pm0.10$~kpc usually adopted in literature. Our method used to calibrate
the distance of P Cyg can apply to very massive and luminous stars both in our
galaxy and neighbour galaxies and can improve the so-called Wind-Momentum
Luminosity relation that potentially applies to calibrate cosmological candles
in the local Universe.
[3]
oai:arXiv.org:1810.08023 [pdf] - 1769582
Intensity Interferometry revival on the C\^ote d'Azur
Lai, Olivier;
Guerin, William;
Vakili, Farrokh;
Kaiser, Robin;
Rivet, Jean Pierre;
Fouché, Mathilde;
Labeyrie, Guillaume;
Chabé, Julien;
Courde, Clément;
Samain, Etienne;
Vernet, David
Submitted: 2018-10-18
Recent advances in photonics have revived the interest in intensity
interferometry for astronomical applications. The success of amplitude
interferometry in the early 1970s, which is now mature and producing
spectacular astrophysical results (e.g. GRAVITY, MATISSE, CHARA, etc.), coupled
with the limited sensitivity of intensity interferometry stalled any progress
on this technique for the past 50 years. However, the precise control of the
optical path difference in amplitude interferometry is constraining for very
long baselines and at shorter wavelengths. Polarization measurements are also
challenging in amplitude interferometry due to instrumental effects. The
fortuitous presence of strong groups in astronomical interferometry and quantum
optics at Universite Cote d'Azur led to the development of a prototype
experiment at Calern Observatory, allowing the measure of the temporal
correlation g(2)(\tau, r=0) in 2016 and of the spatial correlation g^(2)(r) in
2017 with a gain in sensitivity (normalized in observing time and collecting
area) of a factor ~100 compared to Hanbury Brown and Twiss's original Narrabri
Interferometer. We present possible ways to further develop this technique and
point to possible implementations on existing facilities, such as CTA, the VLTI
ATs or the summit of Maunakea, which offer a unique scientific niche.
[4]
oai:arXiv.org:1805.06653 [pdf] - 1731713
Spatial intensity interferometry on three bright stars
Submitted: 2018-05-17, last modified: 2018-08-13
The present articlereports on the first spatial intensity interferometry
measurements on stars since the observations at Narrabri Observatory by Hanbury
Brown et al. in the 1970's. Taking advantage of the progresses in recent years
on photon-counting detectors and fast electronics, we were able to measure the
zero-time delay intensity correlation $g^{(2)}(\tau = 0, r)$ between the light
collected by two 1-m optical telescopes separated by 15 m. Using two marginally
resolved stars ($\alpha$ Lyr and $\beta$ Ori) with R magnitudes of 0.01 and
0.13 respectively, we demonstrate that 4-hour correlation exposures provide
reliable visibilities, whilst a significant loss of contrast is found on alpha
Aur, in agreement with its binary-star nature.
[5]
oai:arXiv.org:1805.06078 [pdf] - 1705323
Optical long baseline intensity interferometry: prospects for stellar
physics
Submitted: 2018-05-15
More than sixty years after the first intensity correlation experiments by
Hanbury Brown and Twiss, there is renewed interest for intensity interferometry
techniques for high angular resolution studies of celestial sources. We report
on a successful attempt to measure the bunching peak in the intensity
correlation function for bright stellar sources with 1 meter telescopes (I2C
project). We propose further improvements of our preliminary experiments of
spatial interferometry between two 1 m telescopes, and discuss the possibility
to export our method to existing large arrays of telescopes.
[6]
oai:arXiv.org:1708.06119 [pdf] - 1731558
Temporal intensity interferometry: photon bunching on three bright stars
Submitted: 2017-08-21
We report the first intensity correlation measured with star light since
Hanbury Brown and Twiss' historical experiments. The photon bunching
$g^{(2)}(\tau, r=0)$, obtained in the photon counting regime, was measured for
3 bright stars, $\alpha$ Boo, $\alpha$ CMi, and $\beta$ Gem. The light was
collected at the focal plane of a 1~m optical telescope, was transported by a
multi-mode optical fiber, split into two avalanche photodiodes and digitally
correlated in real-time. For total exposure times of a few hours, we obtained
contrast values around $2\times10^{-3}$, in agreement with the expectation for
chaotic sources, given the optical and electronic bandwidths of our setup.
Comparing our results with the measurement of Hanbury Brown et al. on $\alpha$
CMi, we argue for the timely opportunity to extend our experiments to measuring
the spatial correlation function over existing and/or foreseen arrays of
optical telescopes diluted over several kilometers. This would enable $\mu$as
long-baseline interferometry in the optical, especially in the visible
wavelengths with a limiting magnitude of 10.