Normalized to: Fonte, R.
[2]
oai:arXiv.org:astro-ph/0507577 [pdf] - 74746
Optical Relative Calibration and Stability Monitoring for the Auger
Fluorescence Detector
Pierre Auger Collaboration;
Aramo, C.;
Brack, J.;
Caruso, R.;
D'Urso, D.;
Fazio, D.;
Fonte, R.;
Gemmeke, H.;
Kleifges, M.;
Knapik, R.;
Insolia, A.;
Matthews, J. A. J.;
Menshikov, A.;
Miller, W.;
Privitera, P.;
Martino, J. Rodriguez
Submitted: 2005-07-25, last modified: 2005-07-26
The stability of the fluorescence telescopes of the Pierre Auger Observatory
is monitored with the optical relative calibration setup. Optical fibers
distribute light pulses to three different diffuser groups within the optical
system. The total charge per pulse is measured for each pixel and compared with
reference calibration measurements. This allows monitoring the short and long
term stability with respect of the relative timing between pixels and the
relative gain for each pixel. The designs of the LED calibration unit (LCU) and
of the Xenon flash lamp used for relative calibration, are described and their
capabilities to monitor the stability of the telescope performances are
studied. We report the analysis of relative calibration data recorded during
2004. Fluctuations in the relative calibration constants provide a measure of
the stability of the FD.
[3]
oai:arXiv.org:astro-ph/0507132 [pdf] - 74301
Quality studies of the data taking conditions for the Auger Fluorescence
Detector
Submitted: 2005-07-06
As more than half of the Fluorescence Detector (FD) of the Auger Observatory
is completed, data taking is becoming a routine job. It is then necessary to
follow strict procedures to assure the quality of the data. An overview of the
data taking methods is given. The nature of the FD background signal is due to
the night sky brightness (stars and planet faint light, moonlight, twilight,
airglow, zodiacal and artificial light) and to the electronic background
(photomultiplier and electronic noise). The analysis of the fluctuations in the
FADC signal (variance analysis), directly proportional to the background mean
light level, performed for each night of data taking is used to monitor the FD
background signal. The data quality is analysed using different techniques,
described in detail. Examples of trigger rates, number of stereo events, dead
time due to moonlight, weather or hardware problems are given. The analysis
comprises several months of data taking, giving an overview of the FD
capabilities, performance and allowing a systematic study of data and their
correlation with the environment.