Normalized to: Fogliani, S.
[1]
oai:arXiv.org:1001.4642 [pdf] - 33158
Off-line radiometric analysis of Planck/LFI data
Tomasi, M.;
Mennella, A.;
Galeotta, S.;
Lowe, S. R.;
Mendes, L.;
Leonardi, R.;
Villa, F.;
Cappellini, B.;
Gregorio, A.;
Meinhold, P.;
Sandri, M.;
Cuttaia, F.;
Terenzi, L.;
Maris, M.;
Valenziano, L.;
Salmon, M. J.;
Bersanelli, M.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschi, E.;
Gasparo, F.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Morgante, G.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) is an array of 22
pseudo-correlation radiometers on-board the Planck satellite to measure
temperature and polarization anisotropies in the Cosmic Microwave Background
(CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the
performances of the LFI, a software suite named LIFE has been developed. Its
aims are to provide a common platform to use for analyzing the results of the
tests performed on the single components of the instrument (RCAs, Radiometric
Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA).
Moreover, its analysis tools are designed to be used during the flight as well
to produce periodic reports on the status of the instrument. The LIFE suite has
been developed using a multi-layered, cross-platform approach. It implements a
number of analysis modules written in RSI IDL, each accessing the data through
a portable and heavily optimized library of functions written in C and C++. One
of the most important features of LIFE is its ability to run the same data
analysis codes both using ground test data and real flight data as input. The
LIFE software suite has been successfully used during the RCA/RAA tests and the
Planck Integrated System Tests. Moreover, the software has also passed the
verification for its in-flight use during the System Operations Verification
Tests, held in October 2008.
[2]
oai:arXiv.org:1001.4730 [pdf] - 33178
Level 1 on-ground telemetry handling in Planck LFI
Zacchei, A.;
Frailis, M.;
Maris, M.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Maino, D.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meinhold, P.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave
Background (CMB) by covering the frequency range 30-70 GHz in three bands. The
primary instrument data source are the temperature samples acquired by the 22
radiometers mounted on the Planck focal plane. Such samples represent the
scientific data of LFI. In addition, the LFI instrument generates the so called
housekeeping data by sampling regularly the on-board sensors and registers. The
housekeeping data provides information on the overall health status of the
instrument and on the scientific data quality. The scientific and housekeeping
data are collected on-board into telemetry packets compliant with the ESA
Packet Telemetry standards. They represent the primary input to the first
processing level of the LFI Data Processing Centre. In this work we show the
software systems which build the LFI Level 1. A real-time assessment system,
based on the ESA SCOS 2000 generic mission control system, has the main purpose
of monitoring the housekeeping parameters of LFI and detect possible anomalies.
A telemetry handler system processes the housekeeping and scientific telemetry
of LFI, generating timelines for each acquisition chain and each housekeeping
parameter. Such timelines represent the main input to the subsequent processing
levels of the LFI DPC. A telemetry quick-look system allows the real-time
visualization of the LFI scientific and housekeeping data, by also calculating
quick statistical functions and fast Fourier transforms. The LFI Level 1 has
been designed to support all the mission phases, from the instrument ground
tests and calibration to the flight operations, and developed according to the
ESA engineering standards.
[3]
oai:arXiv.org:1001.4787 [pdf] - 33194
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
Malaspina, M.;
Franceschi, E.;
Battaglia, P.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschet, C.;
Galeotta, S.;
Gasparo, F.;
Gregorio, A.;
Lapolla, M.;
Leonardi, R.;
Maggio, G.;
Mandolesi, N.;
Manzato, P.;
Maris, M.;
Meharga, M.;
Meinhold, P.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Sandri, M.;
Tomasi, M.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST
(http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation
radiometers at 30, 44, and 70 GHz. Before integrating the overall array
assembly, a first set of tests has been performed for each radiometer chain
assembly (RCA), consisting of two radiometers. In this paper, we describe
Rachel, a software application which has been purposely developed and used
during the RCA test campaign to carry out both near-realtime on-line data
analysis and data storage (in FITS format) of the raw output from the
radiometric chains.
[4]
oai:arXiv.org:1001.4838 [pdf] - 33213
A systematic approach to the Planck LFI end-to-end test and its
application to the DPC Level 1 pipeline
Frailis, M.;
Maris, M.;
Zacchei, A.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Lowe, S. R.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the
handling of the scientific and housekeeping telemetry. It is a critical
component of the Planck ground segment which has to strictly commit to the
project schedule to be ready for the launch and flight operations. In order to
guarantee the quality necessary to achieve the objectives of the Planck
mission, the design and development of the Level 1 software has followed the
ESA Software Engineering Standards. A fundamental step in the software life
cycle is the Verification and Validation of the software. The purpose of this
work is to show an example of procedures, test development and analysis
successfully applied to a key software project of an ESA mission. We present
the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by
detailing the methods used and the results obtained. Different approaches have
been used to test the scientific and housekeeping data processing. Scientific
data processing has been tested by injecting signals with known properties
directly into the acquisition electronics, in order to generate a test dataset
of real telemetry data and reproduce as much as possible nominal conditions.
For the HK telemetry processing, validation software have been developed to
inject known parameter values into a set of real housekeeping packets and
perform a comparison with the corresponding timelines generated by the Level 1.
With the proposed validation and verification procedure, where the on-board and
ground processing are viewed as a single pipeline, we demonstrated that the
scientific and housekeeping processing of the Planck-LFI raw data is correct
and meets the project requirements.
[5]
oai:arXiv.org:1001.4737 [pdf] - 1937606
Optimization of Planck/LFI on--board data handling
Maris, M.;
Tomasi, M.;
Galeotta, S.;
Miccolis, M.;
Hildebrandt, S.;
Frailis, M.;
Rohlfs, R.;
Morisset, N.;
Zacchei, A.;
Bersanelli, M.;
Binko, P.;
Burigana, C.;
Butler, R. C.;
Cuttaia, F.;
Chulani, H.;
D'Arcangelo, O.;
Fogliani, S.;
Franceschi, E.;
Gasparo, F.;
Gomez, F.;
Gregorio, A.;
Herreros, J. M.;
Leonardi, R.;
Leutenegger, P.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Meinhold, P.;
Mennella, A.;
Pasian, F.;
Perrotta, F.;
Rebolo, R.;
Turler, M.;
Zonca, A.
Submitted: 2010-01-26
To asses stability against 1/f noise, the Low Frequency Instrument (LFI)
onboard the Planck mission will acquire data at a rate much higher than the
data rate allowed by its telemetry bandwith of 35.5 kbps. The data are
processed by an onboard pipeline, followed onground by a reversing step. This
paper illustrates the LFI scientific onboard processing to fit the allowed
datarate. This is a lossy process tuned by using a set of 5 parameters Naver,
r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level
of distortion introduced by the onboard processing, EpsilonQ, as a function of
these parameters. It describes the method of optimizing the onboard processing
chain. The tuning procedure is based on a optimization algorithm applied to
unprocessed and uncompressed raw data provided either by simulations, prelaunch
tests or data taken from LFI operating in diagnostic mode. All the needed
optimization steps are performed by an automated tool, OCA2, which ends with
optimized parameters and produces a set of statistical indicators, among them
the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr =
2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup
the process an analytical model is developed that is able to extract most of
the relevant information on EpsilonQ and Cr as a function of the signal
statistics and the processing parameters. This model will be of interest for
the instrument data analysis. The method was applied during ground tests when
the instrument was operating in conditions representative of flight. Optimized
parameters were obtained and the performance has been verified, the required
data rate of 35.5 Kbps has been achieved while keeping EpsilonQ at a level of
3.8% of white noise rms well within the requirements.
[6]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[7]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[8]
oai:arXiv.org:astro-ph/0607439 [pdf] - 83642
Simulating the Zody Emission in the Planck Mission
Submitted: 2006-07-19
The increasing sensitivity of cosmic microwave background (CMB) missions will
require to significantly improve the accuracy in the subtraction of the various
sources of Galactic foreground, from the most relevant components (synchrotron,
dust and free-free emission) to those usually considered of minor relevance in
CMB experiments. With respect to other Galactic diffuse components, the
Zodiacal Light Emission (ZLE) is peculiar, depending not only on the observing
direction but also on the location of the observer within the Solar System: ZLE
behaves then as a large scale, time-dependent foreground. Starting from the
existing far-infrared ZLE models, we discuss the impact of ZLE contribution in
CMB maps and the level of contamination in time ordered data and maps expected
from the forthcoming Planck space mission as well as the Planck capability to
increase our knowledge of the ZLE properties.
[9]
oai:arXiv.org:astro-ph/0603048 [pdf] - 80257
Zodiacal Light Emission in the PLANCK mission
Submitted: 2006-03-02, last modified: 2006-04-07
The PLANCK satellite, scheduled for launch in 2007, will produce a set of all
sky maps in nine frequency bands spanning from 30 GHz to 857 GHz, with an
unprecedented sensitivity and resolution. Planets, minor bodies and diffuse
interplanetary dust will contribute to the (sub)mm sky emission observed by
PLANCK, representing a source of foreground contamination to be removed before
extracting the cosmological information. The aim of this paper is to assess the
expected level of contamination in the survey of the forthcoming PLANCK
mission. Starting from existing far-infrared (far-IR) models of the Zodiacal
Light Emission (ZLE), we present a new method to simulate the time-dependent
level of contamination from ZLE at PLANCK frequencies. We studied the
possibility of PLANCK to detect and separate the ZLE contribution from the
other astrophysical signals. We discuss the conditions in which PLANCK will be
able to increase the existing information on the ZLE and IDP physical
properties.