Normalized to: Florian, S.
[1]
oai:arXiv.org:1902.04048 [pdf] - 1924972
Search for dark matter with a 231-day exposure of liquid argon using
DEAP-3600 at SNOLAB
Ajaj, R.;
Amaudruz, P. -A.;
Araujo, G. R.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bonatt, J.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Doria, L.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Gallacher, D.;
Garcés, E. A.;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Lidgard, J.;
Lindner, T.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-02-11, last modified: 2019-07-04
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter
experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The
detector consists of 3279 kg of LAr contained in a spherical acrylic vessel.
This paper reports on the analysis of a 758 tonne\cdot day exposure taken over
a period of 231 live-days during the first year of operation. No candidate
signal events are observed in the WIMP-search region of interest, which results
in the leading limit on the WIMP-nucleon spin-independent cross section on a
LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a
100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a
detailed background model, this analysis demonstrates the best pulse-shape
discrimination in LAr at threshold, employs a Bayesian photoelectron-counting
technique to improve the energy resolution and discrimination efficiency, and
utilizes two position reconstruction algorithms based on PMT charge and photon
arrival times.
[2]
oai:arXiv.org:1707.08042 [pdf] - 1735166
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Collaboration, DEAP-3600;
:;
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Gulyev, E.;
Hakobyan, R.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Lidgard, J. J.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-07-25, last modified: 2018-08-13
This paper reports the first results of a direct dark matter search with the
DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was
performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target
mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg
capacity. The LAr is viewed by an array of PMTs, which would register
scintillation light produced by rare nuclear recoil signals induced by dark
matter particle scattering. An analysis of 4.44 live days (fiducial exposure of
9.87 tonne-days) of data taken with the nearly full detector during the initial
filling phase demonstrates the detector performance and the best electronic
recoil rejection using pulse-shape discrimination in argon, with leakage
$<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate
signal events are observed, which results in the leading limit on WIMP-nucleon
spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100
GeV/c$^2$ WIMP mass (90% C.L.).
[3]
oai:arXiv.org:1712.01982 [pdf] - 1832993
Design and Construction of the DEAP-3600 Dark Matter Detector
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Churchwell, S.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Gulyev, E.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
White, R.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-12-05, last modified: 2018-04-10
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has
been designed for a direct detection search for particle dark matter using a
single-phase liquid argon target. The projected cross section sensitivity for
DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$
WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the
physical properties and construction of the DEAP-3600 detector.
[4]
oai:arXiv.org:1704.01882 [pdf] - 1565347
Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical
Acrylic Vessel Inner Surface
Broerman, B.;
Boulay, M. G.;
Cai, B.;
Cranshaw, D.;
Dering, K.;
Florian, S.;
Gagnon, R.;
Giampa, P.;
Gilmour, C.;
Hearns, C.;
Kezwer, J.;
Kuźniak, M.;
Pollmann, T.;
Ward, M.
Submitted: 2017-04-06
DEAP-3600 uses liquid argon contained in a spherical acrylic vessel as a
target medium to perform a sensitive spin-independent dark matter search. Argon
scintillates in the vacuum ultraviolet spectrum, which requires wavelength
shifting to convert the VUV photons to visible so they can be transmitted
through the acrylic light guides and detected by the surrounding
photomultiplier tubes. The wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene
was evaporatively deposited to the inner surface of the acrylic vessel under
vacuum. Two evaporations were performed on the DEAP-3600 acrylic vessel with an
estimated coating thickness of 3.00 $\pm$ 0.02 $\mu$m which is successfully
wavelength shifting with liquid argon in the detector. Details on the
wavelength shifter coating requirements, deposition source, testing, and final
performance are presented.