Normalized to: Flanigan, D.
[1]
oai:arXiv.org:1711.02523 [pdf] - 1723973
Development of Multi-Chroic MKIDs for Next-Generation CMB Polarization
Studies
Johnson, B. R.;
Flanigan, D.;
Abitbol, M. H.;
Ade, P. A. R.;
Bryan, S.;
Cho, H. -M.;
Datta, R.;
Day, P.;
Doyle, S.;
Irwin, K.;
Jones, G.;
Li, D.;
Mauskopf, P.;
McCarrick, H.;
McMahon, J.;
Miller, A.;
Pisano, G.;
Song, Y.;
Surdi, H.;
Tucker, C.
Submitted: 2017-11-07, last modified: 2018-07-29
We report on the status of an ongoing effort to develop arrays of
horn-coupled, polarization-sensitive microwave kinetic inductance detectors
(MKIDs) that are each sensitive to two spectral bands between 125 and 280 GHz.
These multi-chroic MKID arrays are tailored for next-generation,
large-detector-count experiments that are being designed to simultaneously
characterize the polarization properties of both the cosmic microwave
background (CMB) and Galactic dust emission. We present our device design and
describe laboratory-based measurement results from two 23-element prototype
arrays. From dark measurements of our first engineering array we demonstrated a
multiplexing factor of 92, showed the resonators respond to bath temperature
changes as expected, and found that the fabrication yield was 100%. From our
first optically loaded array we found the MKIDs respond to millimeter-wave
pulses, additional optical characterization measurements are ongoing. We end by
discussing our plans for scaling up this technology to kilo-pixel arrays over
the next two years.
[2]
oai:arXiv.org:1403.2369 [pdf] - 1715860
A Measurement of the Cosmic Microwave Background B-Mode Polarization
Power Spectrum at Sub-Degree Scales with POLARBEAR
The POLARBEAR Collaboration;
Ade, P. A. R.;
Akiba, Y.;
Anthony, A. E.;
Arnold, K.;
Atlas, M.;
Barron, D.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Dobbs, M.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feng, C.;
Flanigan, D.;
Gilbert, A.;
Grainger, W.;
Halverson, N. W.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Holzapfel, W. L.;
Hori, Y.;
Howard, J.;
Hyland, P.;
Inoue, Y.;
Jaehnig, G. C.;
Jaffe, A. H.;
Keating, B.;
Kermish, Z.;
Keskitalo, R.;
Kisner, T.;
Jeune, M. Le;
Lee, A. T.;
Leitch, E. M.;
Linder, E.;
Lungu, M.;
Matsuda, F.;
Matsumura, T.;
Meng, X.;
Miller, N. J.;
Morii, H.;
Moyerman, S.;
Myers, M. J.;
Navaroli, M.;
Nishino, H.;
Paar, H.;
Peloton, J.;
Poletti, D.;
Quealy, E.;
Rebeiz, G.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Schanning, I.;
Schenck, D. E.;
Sherwin, B. D.;
Shimizu, A.;
Shimmin, C.;
Shimon, M.;
Siritanasak, P.;
Smecher, G.;
Spieler, H.;
Stebor, N.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Takakura, S.;
Tomaru, T.;
Wilson, B.;
Yadav, A.;
Zahn, O.
Submitted: 2014-03-10, last modified: 2018-07-16
We report a measurement of the B-mode polarization power spectrum in the
cosmic microwave background (CMB) using the POLARBEAR experiment in Chile. The
faint B-mode polarization signature carries information about the Universe's
entire history of gravitational structure formation, and the cosmic inflation
that may have occurred in the very early Universe. Our measurement covers the
angular multipole range 500 < l < 2100 and is based on observations of an
effective sky area of 25 square degrees with 3.5 arcmin resolution at 150 GHz.
On these angular scales, gravitational lensing of the CMB by intervening
structure in the Universe is expected to be the dominant source of B-mode
polarization. Including both systematic and statistical uncertainties, the
hypothesis of no B-mode polarization power from gravitational lensing is
rejected at 97.1% confidence. The band powers are consistent with the standard
cosmological model. Fitting a single lensing amplitude parameter A_BB to the
measured band powers, A_BB = 1.12 +/- 0.61 (stat) +0.04/-0.12 (sys) +/- 0.07
(multi), where A_BB = 1 is the fiducial WMAP-9 LCDM value. In this expression,
"stat" refers to the statistical uncertainty, "sys" to the systematic
uncertainty associated with possible biases from the instrument and
astrophysical foregrounds, and "multi" to the calibration uncertainties that
have a multiplicative effect on the measured amplitude A_BB.
[3]
oai:arXiv.org:1710.02239 [pdf] - 1641296
Design and performance of dual-polarization lumped-element kinetic
inductance detectors for millimeter-wave polarimetry
McCarrick, H.;
Jones, G.;
Johnson, B. R.;
Abitbol, M. H.;
Ade, P. A. R.;
Bryan, S.;
Day, P.;
Essinger-Hileman, T.;
Flanigan, D.;
Leduc, H. G.;
Limon, M.;
Mauskopf, P.;
Miller, A.;
Tucker, C.
Submitted: 2017-10-05, last modified: 2017-11-19
Lumped-element kinetic inductance detectors (LEKIDs) are an attractive
technology for millimeter-wave observations that require large arrays of
extremely low-noise detectors. We designed, fabricated and characterized
64-element (128 LEKID) arrays of horn-coupled, dual-polarization LEKIDs
optimized for ground-based CMB polarimetry. Our devices are sensitive to two
orthogonal polarizations in a single spectral band centered on 150 GHz with
$\Delta\nu/\nu=0.2$. The $65\times 65$ mm square arrays are designed to be
tiled into the focal plane of an optical system. We demonstrate the viability
of these dual-polarization LEKIDs with laboratory measurements. The LEKID
modules are tested with an FPGA-based readout system in a sub-kelvin cryostat
that uses a two-stage adiabatic demagnetization refrigerator. The devices are
characterized using a blackbody and a millimeter-wave source. The polarization
properties are measured with a cryogenic stepped half-wave plate. We measure
the resonator parameters and the detector sensitivity, noise spectrum, dynamic
range, and polarization response. The resonators have internal quality factors
approaching $1\times 10^{6}$. The detectors have uniform response between
orthogonal polarizations and a large dynamic range. The detectors are
photon-noise limited above 1 pW of absorbed power. The noise-equivalent
temperatures under a 3.4 K blackbody load are $<100~\mu\mathrm{K\sqrt{s}}$. The
polarization fractions of detectors sensitive to orthogonal polarizations are
>80%. The entire array is multiplexed on a single readout line, demonstrating a
multiplexing factor of 128. The array and readout meet the requirements for 4
arrays to be read out simultaneously for a multiplexing factor of 512. This
laboratory study demonstrates the first dual-polarization LEKID array optimized
for CMB polarimetry and shows the readiness of the detectors for on-sky
observations.
[4]
oai:arXiv.org:1510.06609 [pdf] - 1579736
Photon noise from chaotic and coherent millimeter-wave sources measured
with horn-coupled, aluminum lumped-element kinetic inductance detectors
Flanigan, Daniel;
McCarrick, Heather;
Jones, Glenn;
Johnson, Bradley R.;
Abitbol, Maximilian H.;
Ade, Peter;
Araujo, Derek;
Bradford, Kristi;
Cantor, Robin;
Che, George;
Day, Peter K.;
Doyle, Simon;
Kjellstrand, Carl Bjorn;
LeDuc, Henry G;
Limon, Michele;
Luu, Vy;
Mauskopf, Philip;
Miller, Amber;
Mroczkowski, Tony;
Tucker, Carole;
Zmuidzinas, Jonas
Submitted: 2015-10-22, last modified: 2017-05-24
We report photon-noise limited performance of horn-coupled, aluminum
lumped-element kinetic inductance detectors at millimeter wavelengths. The
detectors are illuminated by a millimeter-wave source that uses an active
multiplier chain to produce radiation between 140 and 160 GHz. We feed the
multiplier with either amplified broadband noise or a continuous-wave tone from
a microwave signal generator. We demonstrate that the detector response over a
40 dB range of source power is well-described by a simple model that considers
the number of quasiparticles. The detector noise-equivalent power (NEP) is
dominated by photon noise when the absorbed power is greater than approximately
1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \,
\mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher
source power levels we observe the relationships between noise and power
expected from the photon statistics of the source signal: $\mathrm{NEP} \propto
P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for
continuous-wave (coherent) illumination.
[5]
oai:arXiv.org:1701.08461 [pdf] - 1581309
High quality factor manganese-doped aluminum lumped-element kinetic
inductance detectors sensitive to frequencies below 100 GHz
Jones, G.;
Johnson, B. R.;
Abitbol, M. H.;
Ade, P. A. R.;
Bryan, S.;
Cho, H. -M.;
Day, P.;
Flanigan, D.;
Irwin, K. D.;
Li, D.;
Mauskopf, P.;
McCarrick, H.;
Miller, A.;
Song, Y. R.;
Tucker, C.
Submitted: 2017-01-29, last modified: 2017-04-15
Aluminum lumped-element kinetic inductance detectors (LEKIDs) sensitive to
millimeter-wave photons have been shown to exhibit high quality factors, making
them highly sensitive and multiplexable. The superconducting gap of aluminum
limits aluminum LEKIDs to photon frequencies above 100 GHz. Manganese-doped
aluminum (Al-Mn) has a tunable critical temperature and could therefore be an
attractive material for LEKIDs sensitive to frequencies below 100 GHz if the
internal quality factor remains sufficiently high when manganese is added to
the film. To investigate, we measured some of the key properties of Al-Mn
LEKIDs. A prototype eight-element LEKID array was fabricated using a 40 nm
thick film of Al-Mn deposited on a 500 {\mu}m thick high-resistivity,
float-zone silicon substrate. The manganese content was 900 ppm, the measured
$T_c = 694\pm1$ mK, and the resonance frequencies were near 150 MHz. Using
measurements of the forward scattering parameter $S_{21}$ at various bath
temperatures between 65 and 250 mK, we determined that the Al-Mn LEKIDs we
fabricated have internal quality factors greater than $2 \times 10^5$, which is
high enough for millimeter-wave astrophysical observations. In the dark
conditions under which these devices were measured, the fractional frequency
noise spectrum shows a shallow slope that depends on bath temperature and probe
tone amplitude, which could be two-level system noise. The anticipated white
photon noise should dominate this level of low-frequency noise when the
detectors are illuminated with millimeter-waves in future measurements. The
LEKIDs responded to light pulses from a 1550 nm light-emitting diode, and we
used these light pulses to determine that the quasiparticle lifetime is 60
{\mu}s.
[6]
oai:arXiv.org:1609.06352 [pdf] - 1492815
Magnetic field dependence of the internal quality factor and noise
performance of lumped-element kinetic inductance detectors
Flanigan, Daniel;
Johnson, Bradley R.;
Abitbol, Maximilian H.;
Bryan, Sean;
Cantor, Robin;
Day, Peter K.;
Jones, Glenn;
Mauskopf, Philip;
McCarrick, Heather;
Miller, Amber;
Zmuidzinas, Jonas
Submitted: 2016-09-20
We present a technique for increasing the internal quality factor of kinetic
inductance detectors (KIDs) by nulling ambient magnetic fields with a properly
applied magnetic field. The KIDs used in this study are made from thin-film
aluminum, they are mounted inside a light-tight package made from bulk
aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film
aluminum has a slightly elevated critical temperature ($T_\mathrm{c} = 1.4 \,
\mathrm{K}$), it therefore transitions before the package ($T_\mathrm{c} = 1.2
\, \mathrm{K}$), which also serves as a magnetic shield. On cooldown, ambient
magnetic fields as small as approximately $30 \, \mathrm{\mu T}$ can produce
vortices in the thin-film aluminum as it transitions because the bulk aluminum
package has not yet transitioned and therefore is not yet shielding. These
vortices become trapped inside the aluminum package below $1.2 \, \mathrm{K}$
and ultimately produce low internal quality factors in the thin-film
superconducting resonators. We show that by controlling the strength of the
magnetic field present when the thin film transitions, we can control the
internal quality factor of the resonators. We also compare the noise
performance with and without vortices present, and find no evidence for excess
noise beyond the increase in amplifier noise, which is expected with increasing
loss.
[7]
oai:arXiv.org:1607.03796 [pdf] - 1441570
Polarization Sensitive Multi-Chroic MKIDs
Johnson, Bradley R.;
Flanigan, Daniel;
Abitbol, Maximilian H.;
Ade, Peter A. R.;
Bryan, Sean;
Cho, Hsiao-Mei;
Datta, Rahul;
Day, Peter;
Doyle, Simon;
Irwin, Kent;
Jones, Glenn;
Kernasovskiy, Sarah;
Li, Dale;
Mauskopf, Phil;
McCarrick, Heather;
McMahon, Jeff;
Miller, Amber;
Pisano, Giampaolo;
Song, Yanru;
Surdi, Harshad;
Tucker, Carole
Submitted: 2016-07-13
We report on the development of scalable prototype microwave kinetic
inductance detector (MKID) arrays tailored for future multi-kilo-pixel
experiments that are designed to simultaneously characterize the polarization
properties of both the cosmic microwave background (CMB) and Galactic dust
emission. These modular arrays are composed of horn-coupled,
polarization-sensitive MKIDs, and each pixel has four detectors: two
polarizations in two spectral bands between 125 and 280 GHz. A horn is used to
feed each array element, and a planar orthomode transducer, composed of two
waveguide probe pairs, separates the incoming light into two linear
polarizations. Diplexers composed of resonant-stub band-pass filters separate
the radiation into 125 to 170 GHz and 190 to 280 GHz pass bands. The
millimeter-wave power is ultimately coupled to a hybrid co-planar waveguide
microwave kinetic inductance detector using a novel, broadband circuit
developed by our collaboration. Electromagnetic simulations show the expected
absorption efficiency of the detector is approximately 90%. Array fabrication
will begin in the summer of 2016.
[8]
oai:arXiv.org:1607.03448 [pdf] - 1531012
Development of dual-polarization LEKIDs for CMB observations
McCarrick, Heather;
Abitbol, Maximilian H.;
Ade, Peter A. R.;
Barry, Peter;
Bryan, Sean;
Che, George;
Day, Peter;
Doyle, Simon;
Flanigan, Daniel;
Johnson, Bradley R.;
Jones, Glenn;
LeDuc, Henry G.;
Limon, Michele;
Mauskopf, Philip;
Miller, Amber;
Tucker, Carole;
Zmuidzinas, Jonas
Submitted: 2016-07-12
We discuss the design considerations and initial measurements from arrays of
dual-polarization, lumped element kinetic inductance detectors (LEKIDs)
nominally designed for cosmic microwave background (CMB) studies. The detectors
are horn-coupled, and each array element contains two single-polarization
LEKIDs, which are made from thin-film aluminum and optimized for a single
spectral band centered on 150 GHz. We are developing two array architectures,
one based on 160 micron thick silicon wafers and the other based on
silicon-on-insulator (SOI) wafers with a 30 micron thick device layer. The
20-element test arrays (40 LEKIDs) are characterized with both a
linearly-polarized electronic millimeter wave source and a thermal source. We
present initial measurements including the noise spectra, noise-equivalent
temperature, and responsivity. We discuss future testing and further design
optimizations to be implemented.
[9]
oai:arXiv.org:1512.01847 [pdf] - 1347758
A Titanium Nitride Absorber for Controlling Optical Crosstalk in
Horn-Coupled Aluminum LEKID Arrays for Millimeter Wavelengths
McCarrick, H.;
Flanigan, D.;
Jones, G.;
Johnson, B. R.;
Ade, P. A. R.;
Bradford, K.;
Bryan, S.;
Cantor, R.;
Che, G.;
Day, P.;
Doyle, S.;
Leduc, H.;
Limon, M.;
Mauskopf, P.;
Miller, A.;
Mroczkowski, T.;
Tucker, C.;
Zmuidzinas, J.
Submitted: 2015-12-06
We discuss the design and measured performance of a titanium nitride (TiN)
mesh absorber we are developing for controlling optical crosstalk in
horn-coupled lumped-element kinetic inductance detector arrays for
millimeter-wavelengths. This absorber was added to the fused silica
anti-reflection coating attached to previously-characterized, 20-element
prototype arrays of LEKIDs fabricated from thin-film aluminum on silicon
substrates. To test the TiN crosstalk absorber, we compared the measured
response and noise properties of LEKID arrays with and without the TiN mesh.
For this test, the LEKIDs were illuminated with an adjustable, incoherent
electronic millimeter-wave source. Our measurements show that the optical
crosstalk in the LEKID array with the TiN absorber is reduced by 66\% on
average, so the approach is effective and a viable candidate for future
kilo-pixel arrays.
[10]
oai:arXiv.org:1509.04658 [pdf] - 1347523
WSPEC: A waveguide filter-bank focal plane array spectrometer for
millimeter wave astronomy and cosmology
Bryan, Sean;
Aguirre, James;
Che, George;
Doyle, Simon;
Flanigan, Daniel;
Groppi, Christopher;
Johnson, Bradley;
Jones, Glenn;
Mauskopf, Philip;
McCarrick, Heather;
Monfardini, Alessandro;
Mroczkowski, Tony
Submitted: 2015-09-15
Imaging and spectroscopy at (sub-)millimeter wavelengths are key frontiers in
astronomy and cosmology. Large area spectral surveys with moderate spectral
resolution (R=50-200) will be used to characterize large scale structure and
star formation through intensity mapping surveys in emission lines such as the
CO rotational transitions. Such surveys will also be used to study the SZ
effect, and will detect the emission lines and continuum spectrum of individual
objects. WSPEC is an instrument proposed to target these science goals. It is a
channelizing spectrometer realized in rectangular waveguide, fabricated using
conventional high-precision metal machining. Each spectrometer is coupled to
free space with a machined feed horn, and the devices are tiled into a 2D array
to fill the focal plane of the telescope. The detectors will be aluminum
Lumped-Element Kinetic Inductance Detectors (LEKIDs). To target the CO lines
and SZ effect, we will have bands at 135-175 GHz and 190-250 GHz, each
Nyquist-sampled at R~200 resolution. Here we discuss the instrument concept and
design, and successful initial testing of a WR10 (i.e. 90 GHz) prototype
spectrometer. We recently tested a WR5 (180 GHz) prototype to verify that the
concept works at higher frequencies, and also designed a resonant backshort
structure that may further increase the optical efficiency. We are making
progress towards integrating a spectrometer with a LEKID array and deploying a
prototype device to a telescope for first light.
[11]
oai:arXiv.org:1404.7103 [pdf] - 1546171
Galaxy cluster scaling relations measured with APEX-SZ
Bender, A. N.;
Kennedy, J.;
Ade, P. A. R.;
Basu, K.;
Bertoldi, F.;
Burkutean, S.;
Clarke, J.;
Dahlin, D.;
Dobbs, M.;
Ferrusca, D.;
Flanigan, D.;
Halverson, N. W.;
Holzapfel, W. L.;
Horellou, C.;
Johnson, B. R.;
Kermish, Z. D.;
Klein, M.;
Kneissl, R.;
Lanting, T.;
Lee, A. T.;
Mehl, J.;
Menten, K. M.;
Muders, D.;
Nagarajan, A.;
Pacaud, F.;
Reichardt, C. L.;
Richards, P. L.;
Schaaf, R.;
Schwan, D.;
Sommer, M. W.;
Spieler, H.;
Tucker, C.;
Westbrook, B.
Submitted: 2014-04-28, last modified: 2015-04-26
We present thermal Sunyaev-Zel'dovich effect (SZE) measurements for 42 galaxy
clusters observed at 150 GHz with the APEX-SZ experiment. For each cluster, we
model the pressure profile and calculate the integrated Comptonization $Y$ to
estimate the total thermal energy of the intracluster medium (ICM). We compare
the measured $Y$ values to X-ray observables of the ICM from the literature
(cluster gas mass $M_{\rm{gas}}$, temperature $T_X$, and $Y_X
=M_{\rm{gas}}T_X$) that relate to total cluster mass. We measure power law
scaling relations, including an intrinsic scatter, between the SZE and X-ray
observables for three subsamples within the set of 42 clusters that have
uniform X-ray analysis in the literature. We observe that differences between
these X-ray analyses introduce significant variability into the measured
scaling relations, particularly affecting the normalization. For all three
subsamples, we find results consistent with a self-similar model of cluster
evolution dominated by gravitational effects. Comparing to predictions from
numerical simulations, these scaling relations prefer models that include
cooling and feedback in the ICM. Lastly, we measure an intrinsic scatter of
$\sim28$ per cent in the $Y-Y_X\,$ scaling relation for all three subsamples.
[12]
oai:arXiv.org:1407.7749 [pdf] - 971383
Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic
Inductance Detectors for Millimeter Wavelengths
McCarrick, H.;
Flanigan, D.;
Jones, G.;
Johnson, B. R.;
Ade, P.;
Araujo, D.;
Bradford, K.;
Cantor, R.;
Che, G.;
Day, P.;
Doyle, S.;
Leduc, H.;
Limon, M.;
Luu, V.;
Mauskopf, P.;
Miller, A.;
Mroczkowski, T.;
Tucker, C.;
Zmuidzinas, J.
Submitted: 2014-07-29, last modified: 2015-03-26
We discuss the design, fabrication, and testing of prototype horn-coupled,
lumped-element kinetic inductance detectors (LEKIDs) designed for cosmic
microwave background (CMB) studies. The LEKIDs are made from a thin aluminum
film deposited on a silicon wafer and patterned using standard
photolithographic techniques at STAR Cryoelectronics, a commercial device
foundry. We fabricated twenty-element arrays, optimized for a spectral band
centered on 150 GHz, to test the sensitivity and yield of the devices as well
as the multiplexing scheme. We characterized the detectors in two
configurations. First, the detectors were tested in a dark environment with the
horn apertures covered, and second, the horn apertures were pointed towards a
beam-filling cryogenic blackbody load. These tests show that the multiplexing
scheme is robust and scalable, the yield across multiple LEKID arrays is 91%,
and the noise-equivalent temperatures (NET) for a 4 K optical load are in the
range 26$\thinspace\pm6 \thinspace \mu \mbox{K} \sqrt{\mbox{s}}$.
[13]
oai:arXiv.org:1503.06528 [pdf] - 969448
WSPEC: A Waveguide Filter Bank Spectrometer
Che, George;
Bryan, Sean;
Underhill, Matthew;
Mauskopf, Philip;
Groppi, Christopher;
Jones, Glenn;
Johnson, Bradley;
McCarrick, Heather;
Flanigan, Daniel;
Day, Peter
Submitted: 2015-03-23
We have designed, fabricated, and measured a 5-channel prototype spectrometer
pixel operating in the WR10 band to demonstrate a novel moderate-resolution
(R=f/{\Delta}f~100), multi-pixel, broadband, spectrometer concept for mm and
submm-wave astronomy. Our design implements a transmission line filter bank
using waveguide resonant cavities as a series of narrow-band filters, each
coupled to an aluminum kinetic inductance detector (KID). This technology has
the potential to perform the next generation of spectroscopic observations
needed to drastically improve our understanding of the epoch of reionization
(EoR), star formation, and large-scale structure of the universe. We present
our design concept, results from measurements on our prototype device, and the
latest progress on our efforts to develop a 4-pixel demonstrator instrument
operating in the 130-250 GHz band.
[14]
oai:arXiv.org:1503.04684 [pdf] - 957156
Design of Dual-Polarization Horn-Coupled Kinetic Inductance Detectors
for Cosmic Microwave Background Polarimetry
Bryan, Sean;
Bradford, Kristi;
Che, George;
Day, Peter;
Flanigan, Daniel;
Johnson, Bradley R.;
Jones, Glenn;
Kjellstrand, Bjorn;
Limon, Michele;
Mauskopf, Philip;
McCarrick, Heather;
Miller, Amber;
Smiley, Brian
Submitted: 2015-03-16
Mapping the polarization of the Cosmic Microwave Background is yielding
exciting data on the origin of the universe, the reionization of the universe,
and the growth of cosmic structure. Kilopixel arrays represent the current
state of the art, but advances in detector technology are needed to enable the
larger detector arrays needed for future measurements. Here we present a design
for single-band dual-polarization Kinetic Inductance Detectors (KIDs) at 20%
bandwidths centered at 145, 220, and 280 GHz. The detection and readout system
is nearly identical to the successful photon-noise-limited aluminum
Lumped-Element KIDs that have been recently built and tested by some of the
authors. Fabricating large focal plane arrays of the feed horns and
quarter-wave backshorts requires only conventional precision machining. Since
the detectors and readout lines consist only of a single patterned aluminum
layer on a SOI wafer, arrays of the detectors can be built commercially or at a
standard university cleanroom.
[15]
oai:arXiv.org:1407.6249 [pdf] - 880220
A LEKID-based CMB instrument design for large-scale observations in
Greenland
Araujo, D. C.;
Ade, P. A. R.;
Bond, J. R.;
Bradford, K. J.;
Chapman, D.;
Che, G.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C. E.;
Hillbrand, S. N.;
Johnson, B. R.;
Jones, G.;
Limon, M.;
Miller, A. D.;
Mauskopf, P.;
McCarrick, H.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2014-07-10, last modified: 2014-10-10
We present the results of a feasibility study, which examined deployment of a
ground-based millimeter-wave polarimeter, tailored for observing the cosmic
microwave background (CMB), to Isi Station in Greenland. The instrument for
this study is based on lumped-element kinetic inductance detectors (LEKIDs) and
an F/2.4 catoptric, crossed-Dragone telescope with a 500 mm aperture. The
telescope is mounted inside the receiver and cooled to $<\,4$ K by a
closed-cycle $^4$He refrigerator to reduce background loading on the detectors.
Linearly polarized signals from the sky are modulated with a metal-mesh
half-wave plate that is rotated at the aperture stop of the telescope with a
hollow-shaft motor based on a superconducting magnetic bearing. The modular
detector array design includes at least 2300 LEKIDs, and it can be configured
for spectral bands centered on 150~GHz or greater. Our study considered
configurations for observing in spectral bands centered on 150, 210 and
267~GHz. The entire polarimeter is mounted on a commercial precision rotary air
bearing, which allows fast azimuth scan speeds with negligible vibration and
mechanical wear over time. A slip ring provides power to the instrument,
enabling circular scans (360 degrees of continuous rotation). This mount, when
combined with sky rotation and the latitude of the observation site, produces a
hypotrochoid scan pattern, which yields excellent cross-linking and enables
34\% of the sky to be observed using a range of constant elevation scans. This
scan pattern and sky coverage combined with the beam size (15~arcmin at
150~GHz) makes the instrument sensitive to $5 < \ell < 1000$ in the angular
power spectra.
[16]
oai:arXiv.org:1312.6646 [pdf] - 851338
Measurement of the Cosmic Microwave Background Polarization Lensing
Power Spectrum with the POLARBEAR experiment
POLARBEAR Collaboration;
Ade, P. A. R.;
Akiba, Y.;
Anthony, A. E.;
Arnold, K.;
Atlas, M.;
Barron, D.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Dobbs, M.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feng, C.;
Flanigan, D.;
Gilbert, A.;
Grainger, W.;
Halverson, N. W.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Holzapfel, W. L.;
Hori, Y.;
Howard, J.;
Hyland, P.;
Inoue, Y.;
Jaehnig, G. C.;
Jaffe, A.;
Keating, B.;
Kermish, Z.;
Keskitalo, R.;
Kisner, T.;
Jeune, M. Le;
Lee, A. T.;
Linder, E.;
Leitch, E. M.;
Lungu, M.;
Matsuda, F.;
Matsumura, T.;
Meng, X.;
Miller, N. J.;
Morii, H.;
Moyerman, S.;
Myers, M. J.;
Navaroli, M.;
Nishino, H.;
Paar, H.;
Peloton, J.;
Quealy, E.;
Rebeiz, G.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Schanning, I.;
Schenck, D. E.;
Sherwin, B.;
Shimizu, A.;
Shimmin, C.;
Shimon, M.;
Siritanasak, P.;
Smecher, G.;
Spieler, H.;
Stebor, N.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Takakura, S.;
Tomaru, T.;
Wilson, B.;
Yadav, A.;
Zahn, O.
Submitted: 2013-12-23, last modified: 2014-04-27
Gravitational lensing due to the large-scale distribution of matter in the
cosmos distorts the primordial Cosmic Microwave Background (CMB) and thereby
induces new, small-scale $B$-mode polarization. This signal carries detailed
information about the distribution of all the gravitating matter between the
observer and CMB last scattering surface. We report the first direct evidence
for polarization lensing based on purely CMB information, from using the
four-point correlations of even- and odd-parity $E$- and $B$-mode polarization
mapped over $\sim30$ square degrees of the sky measured by the POLARBEAR
experiment. These data were analyzed using a blind analysis framework and
checked for spurious systematic contamination using null tests and simulations.
Evidence for the signal of polarization lensing and lensing $B$-modes is found
at 4.2$\sigma$ (stat.+sys.) significance. The amplitude of matter fluctuations
is measured with a precision of $27\%$, and is found to be consistent with the
Lambda Cold Dark Matter ($\Lambda$CDM) cosmological model. This measurement
demonstrates a new technique, capable of mapping all gravitating matter in the
Universe, sensitive to the sum of neutrino masses, and essential for cleaning
the lensing $B$-mode signal in searches for primordial gravitational waves.
[17]
oai:arXiv.org:1312.6645 [pdf] - 812508
Evidence for Gravitational Lensing of the Cosmic Microwave Background
Polarization from Cross-correlation with the Cosmic Infrared Background
POLARBEAR Collaboration;
Ade, P. A. R.;
Akiba, Y.;
Anthony, A. E.;
Arnold, K.;
Atlas, M.;
Barron, D.;
Boettger, D.;
Borrill, J.;
Borys, C.;
Chapman, S.;
Chinone, Y.;
Dobbs, M.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feng, C.;
Flanigan, D.;
Gilbert, A.;
Grainger, W.;
Halverson, N. W.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Holzapfel, W. L.;
Hori, Y.;
Howard, J.;
Hyland, P.;
Inoue, Y.;
Jaehnig, G. C.;
Jaffe, A.;
Keating, B.;
Kermish, Z.;
Keskitalo, R.;
Kisner, T.;
Jeune, M. Le;
Lee, A. T.;
Leitch, E. M.;
Linder, E.;
Lungu, M.;
Matsuda, F.;
Matsumura, T.;
Meng, X.;
Miller, N. J.;
Morii, H.;
Moyerman, S.;
Myers, M. J.;
Navaroli, M.;
Nishino, H.;
Paar, H.;
Peloton, J.;
Quealy, E.;
Rebeiz, G.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Rotermund, K.;
Schanning, I.;
Schenck, D. E.;
Sherwin, B. D.;
Shimizu, A.;
Shimmin, C.;
Shimon, M.;
Siritanasak, P.;
Smecher, G.;
Spieler, H.;
Stebor, N.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Takakura, S.;
Tikhomirov, A.;
Tomaru, T.;
Wilson, B.;
Yadav, A.;
Zahn, O.
Submitted: 2013-12-23, last modified: 2014-03-07
We reconstruct the gravitational lensing convergence signal from Cosmic
Microwave Background (CMB) polarization data taken by the POLARBEAR experiment
and cross-correlate it with Cosmic Infrared Background (CIB) maps from the
Herschel satellite. From the cross-spectra, we obtain evidence for
gravitational lensing of the CMB polarization at a statistical significance of
4.0$\sigma$ and evidence for the presence of a lensing $B$-mode signal at a
significance of 2.3$\sigma$. We demonstrate that our results are not biased by
instrumental and astrophysical systematic errors by performing null-tests,
checks with simulated and real data, and analytical calculations. This
measurement of polarization lensing, made via the robust cross-correlation
channel, not only reinforces POLARBEAR auto-correlation measurements, but also
represents one of the early steps towards establishing CMB polarization lensing
as a powerful new probe of cosmology and astrophysics.
[18]
oai:arXiv.org:1308.0235 [pdf] - 857218
The Detector System for the Stratospheric Kinetic Inductance Polarimeter
(SKIP)
Johnson, B. R.;
Ade, P. A. R.;
Araujo, D.;
Bradford, K. J.;
Chapman, D.;
Day, P. K.;
Didier, J.;
Doyle, S.;
Eriksen, H. K.;
Flanigan, D.;
Groppi, C.;
Hillbrand, S.;
Jones, G.;
Limon, M.;
Mauskopf, P.;
McCarrick, H.;
Miller, A.;
Mroczkowski, T.;
Reichborn-Kjennerud, B.;
Smiley, B.;
Sobrin, J.;
Wehus, I. K.;
Zmuidzinas, J.
Submitted: 2013-08-01, last modified: 2014-01-05
The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed
balloon-borne experiment designed to study the cosmic microwave background, the
cosmic infrared background and Galactic dust emission by observing 1133 square
degrees of sky in the Northern Hemisphere with launches from Kiruna, Sweden.
The instrument contains 2317 single-polarization, horn-coupled, aluminum
lumped-element kinetic inductance detectors (LEKID). The LEKIDs will be
maintained at 100 mK with an adiabatic demagnetization refrigerator. The
polarimeter operates in two configurations, one sensitive to a spectral band
centered on 150 GHz and the other sensitive to 260 and 350 GHz bands. The
detector readout system is based on the ROACH-1 board, and the detectors will
be biased below 300 MHz. The detector array is fed by an F/2.4 crossed-Dragone
telescope with a 500 mm aperture yielding a 15 arcmin FWHM beam at 150 GHz. To
minimize detector loading and maximize sensitivity, the entire optical system
will be cooled to 1 K. Linearly polarized sky signals will be modulated with a
metal-mesh half-wave plate that is mounted at the telescope aperture and
rotated by a superconducting magnetic bearing. The observation program consists
of at least two, five-day flights beginning with the 150 GHz observations.
[19]
oai:arXiv.org:1210.7768 [pdf] - 1152551
The POLARBEAR Experiment
Kermish, Z.;
Ade, P.;
Anthony, A.;
Arnold, K.;
Arnold, K.;
Barron, D.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Dobbs, M. A.;
Errard, J.;
Fabbian, G.;
Flanigan, D.;
Fuller, G.;
Ghribi, A.;
Grainger, W.;
Halverson, N.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Holzapfel, W. L.;
Howard, J.;
Hyland, P.;
Jaffe, A.;
Keating, B.;
Kisner, T.;
Lee, A. T.;
Jeune, M. Le;
Linder, E.;
Lungu, M.;
Matsuda, F.;
Matsumura, T.;
Meng, X.;
Miller, N. J.;
Morii, H.;
Moyerman, S.;
Myers, M. J.;
Nishino, H.;
Paar, H.;
Quealy, E.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Shimizu, A.;
Shimon, M.;
Shimmin, C.;
Sholl, M.;
Siritanasak, P.;
Spieler, H.;
Stebor, N.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Tomaru, T.;
Tucker, C.;
Zahn, O.
Submitted: 2012-10-29
We present the design and characterization of the POLARBEAR experiment.
POLARBEAR will measure the polarization of the cosmic microwave background
(CMB) on angular scales ranging from the experiment's 3.5 arcminute beam size
to several degrees. The experiment utilizes a unique focal plane of 1,274
antenna-coupled, polarization sensitive TES bolometers cooled to 250
milliKelvin. Employing this focal plane along with stringent control over
systematic errors, POLARBEAR has the sensitivity to detect the expected small
scale B-mode signal due to gravitational lensing and search for the large scale
B-mode signal from inflationary gravitational waves.
POLARBEAR was assembled for an engineering run in the Inyo Mountains of
California in 2010 and was deployed in late 2011 to the Atacama Desert in
Chile. An overview of the instrument is presented along with characterization
results from observations in Chile.
[20]
oai:arXiv.org:1210.7877 [pdf] - 1152574
The bolometric focal plane array of the Polarbear CMB experiment
Arnold, K.;
Ade, P. A. R.;
Anthony, A. E.;
Barron, D.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Dobbs, M. A.;
Errard, J.;
Fabbian, G.;
Flanigan, D.;
Fuller, G.;
Ghribi, A.;
Grainger, W.;
Halverson, N.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Holzapfel, W. L.;
Howard, J.;
Hyland, P.;
Jaffe, A.;
Keating, B.;
Kermish, Z.;
Kisner, T.;
Jeune, M. Le;
Lee, A. T.;
Linder, E.;
Lungu, M.;
Matsuda, F.;
Matsumura, T.;
Miller, N. J.;
Meng, X.;
Morii, H.;
Moyerman, S.;
Myers, M. J.;
Nishino, H.;
Paar, H.;
Quealy, E.;
Reichardt, C.;
Richards, P. L.;
Ross, C.;
Shimizu, A.;
Shimmin, C.;
Shimon, M.;
Sholl, M.;
Siritanasak, P.;
Spieler, H.;
Stebor, N.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Tomaru, T.;
Tucker, C.;
Zahn, O.
Submitted: 2012-10-29
The Polarbear Cosmic Microwave Background (CMB) polarization experiment is
currently observing from the Atacama Desert in Northern Chile. It will
characterize the expected B-mode polarization due to gravitational lensing of
the CMB, and search for the possible B-mode signature of inflationary
gravitational waves. Its 250 mK focal plane detector array consists of 1,274
polarization-sensitive antenna-coupled bolometers, each with an associated
lithographed band-defining filter. Each detector's planar antenna structure is
coupled to the telescope's optical system through a contacting dielectric
lenslet, an architecture unique in current CMB experiments. We present the
initial characterization of this focal plane.
[21]
oai:arXiv.org:1112.4215 [pdf] - 1092468
Frequency Multiplexed SQUID Readout of Large Bolometer Arrays for Cosmic
Microwave Background Measurements
Dobbs, M. A.;
Lueker, M.;
Aird, K. A.;
Bender, A. N.;
Benson, B. A.;
Bleem, L. E.;
Carlstrom, J. E.;
Chang, C. L.;
Cho, H. -M.;
Clarke, J.;
Crawford, T. M.;
Crites, A. T.;
Flanigan, D. I.;
de Haan, T.;
George, E. M.;
Halverson, N. W.;
Holzapfel, W. L.;
Hrubes, J. D.;
Johnson, B. R.;
Joseph, J.;
Keisler, R.;
Kennedy, J.;
Kermish, Z.;
Lanting, T. M.;
Lee, A. T.;
Leitch, E. M.;
Luong-Van, D.;
McMahon, J. J.;
Mehl, J.;
Meyer, S. S.;
Montroy, T. E.;
Padin, S.;
Plagge, T.;
Pryke, C.;
Richards, P. L.;
Ruhl, J. E.;
Schaffer, K. K.;
Schwan, D.;
Shirokoff, E.;
Spieler, H. G.;
Staniszewski, Z.;
Stark, A. A.;
Vanderlinde, K.;
Vieira, J. D.;
Vu, C.;
Westbrook, B.;
Williamson, R.
Submitted: 2011-12-18, last modified: 2012-07-17
A technological milestone for experiments employing Transition Edge Sensor
(TES) bolometers operating at sub-kelvin temperature is the deployment of
detector arrays with 100s--1000s of bolometers. One key technology for such
arrays is readout multiplexing: the ability to read out many sensors
simultaneously on the same set of wires. This paper describes a
frequency-domain multiplexed readout system which has been developed for and
deployed on the APEX-SZ and South Pole Telescope millimeter wavelength
receivers. In this system, the detector array is divided into modules of seven
detectors, and each bolometer within the module is biased with a unique ~MHz
sinusoidal carrier such that the individual bolometer signals are well
separated in frequency space. The currents from all bolometers in a module are
summed together and pre-amplified with Superconducting Quantum Interference
Devices (SQUIDs) operating at 4 K. Room-temperature electronics demodulate the
carriers to recover the bolometer signals, which are digitized separately and
stored to disk. This readout system contributes little noise relative to the
detectors themselves, is remarkably insensitive to unwanted microphonic
excitations, and provides a technology pathway to multiplexing larger numbers
of sensors.
[22]
oai:arXiv.org:1110.2101 [pdf] - 423233
Ultra High Energy Cosmology with POLARBEAR
Keating, B.;
Moyerman, S.;
Boettger, D.;
Edwards, J.;
Fuller, G.;
Matsuda, F.;
Miller, N.;
Paar, H.;
Rebeiz, G.;
Schanning, I.;
Shimon, M.;
Stebor, N.;
Arnold, K.;
Flanigan, D.;
Holzapfel, W.;
Howard, J.;
Kermish, Z.;
Lee, A.;
Lungu, M.;
Myers, M.;
Nishino, H.;
O'Brient, R.;
Quealy, E.;
Reichardt, C.;
Richards, P.;
Shimmin, C.;
Steinbach, B.;
Suzuki, A.;
Zahn, O.;
Borrill, J.;
Cantalupo, C.;
Kisner, E.;
Linder, E.;
Sholl, M.;
Spieler, H.;
Anthony, A.;
Halverson, N.;
Errard, J.;
Fabbian, G.;
Jeune, M. Le;
Stompor, R.;
Jaffe, A.;
O'Dea, D.;
Chinone, Y.;
Hasegawa, M.;
Hazumi, M.;
Matsumura, T.;
Morii, H.;
Shimizu, A.;
Tomaru, T.;
Hyland, P.;
Dobbs, M.;
Ade, P.;
Grainger, W.;
Tucker, C.
Submitted: 2011-10-10
Observations of the temperature anisotropy of the Cosmic Microwave Background
(CMB) lend support to an inflationary origin of the universe, yet no direct
evidence verifying inflation exists. Many current experiments are focussing on
the CMB's polarization anisotropy, specifically its curl component (called
"B-mode" polarization), which remains undetected. The inflationary paradigm
predicts the existence of a primordial gravitational wave background that
imprints a unique B-mode signature on the CMB's polarization at large angular
scales. The CMB B-mode signal also encodes gravitational lensing information at
smaller angular scales, bearing the imprint of cosmological large scale
structures (LSS) which in turn may elucidate the properties of cosmological
neutrinos. The quest for detection of these signals; each of which is orders of
magnitude smaller than the CMB temperature anisotropy signal, has motivated the
development of background-limited detectors with precise control of systematic
effects. The POLARBEAR experiment is designed to perform a deep search for the
signature of gravitational waves from inflation and to characterize lensing of
the CMB by LSS. POLARBEAR is a 3.5 meter ground-based telescope with 3.8
arcminute angular resolution at 150 GHz. At the heart of the POLARBEAR receiver
is an array featuring 1274 antenna-coupled superconducting transition edge
sensor (TES) bolometers cooled to 0.25 Kelvin. POLARBEAR is designed to reach a
tensor-to-scalar ratio of 0.025 after two years of observation -- more than an
order of magnitude improvement over the current best results, which would test
physics at energies near the GUT scale. POLARBEAR had an engineering run in the
Inyo Mountains of Eastern California in 2010 and will begin observations in the
Atacama Desert in Chile in 2011.
[23]
oai:arXiv.org:1011.0763 [pdf] - 348120
The new generation CMB B-mode polarization experiment: POLARBEAR
The Polarbear Collaboration;
Errard, J.;
Ade, P. A. R.;
Anthony, A.;
Arnold, K.;
Aubin, F.;
Boettger, D.;
Borrill, J.;
Cantalupo, C.;
Dobbs, M. A.;
Flanigan, D.;
Ghribi, A.;
Halverson, N.;
Hazumi, M.;
Holzapfel, W. L.;
Howard, J.;
Hyland, P.;
Jaffe, A.;
Keating, B.;
Kisner, T.;
Kermish, Z.;
Lee, A. T.;
Linder, E.;
Lungu, M.;
Matsumura, T.;
Miller, N.;
Meng, X.;
Myers, M.;
Nishino, H.;
O'Brient, R.;
O'Dea, D.;
Reichardt, C.;
Schanning, I.;
Shimizu, A.;
Shimmin, C.;
Shimon, M.;
Spieler, H.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Tomaru, T.;
Tran, H. T.;
Tucker, C.;
Quealy, E.;
Richards, P. L.;
Zahn, O.
Submitted: 2010-11-02
We describe the Cosmic Microwave Background (CMB) polarization experiment
called Polarbear. This experiment will use the dedicated Huan Tran Telescope
equipped with a powerful 1,200-bolometer array receiver to map the CMB
polarization with unprecedented accuracy. We summarize the experiment, its
goals, and current status.