Normalized to: Finkbeiner, F.
[1]
oai:arXiv.org:1908.02687 [pdf] - 2050188
Towards 100,000-pixel microcalorimeter arrays using multi-absorber
transition-edge sensors
Smith, S. J.;
Adams, J. S.;
Bandler, S. R.;
Beaumont, S.;
Chervenak, J. A.;
Datesman, A. M.;
Finkbeiner, F. M.;
Hummatov, R.;
Kelly, R. L.;
Kilbourne, C. A.;
Miniussi, A. R.;
Porter, F. S.;
Sadleir, J. E.;
Sakai, K.;
Wakeham, N. A.;
Wassell, E. J.;
Witthoeft, M. C.;
Ryu, K.
Submitted: 2019-08-07
We report on the development of multi-absorber transition edge sensors
(TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers
each with a different thermal conductance to a TES. Position information is
encoded in the pulse shape. With some trade-off in performance, hydras enable
very large format arrays without the prohibitive increase in bias and read-out
components associated with arrays of individual TESs. Hydras are under
development for the next generation of space telescope such as Lynx. Lynx is a
NASA concept under study that will combine a < 1 arcsecond angular resolution
optic with 100,000-pixel microcalorimeter array with energy resolution of
deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results
from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and
50 micron pitch are studied. Arrays incorporate, for the first time, microstrip
buried wiring layers of suitable pitch and density required to readout a
full-scale Lynx array. The resolution from the coadded energy histogram
including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at
an energy of 1.5 keV for the 25 micron and 50 micron absorber designs
respectively. Position discrimination is demonstrated from parameterization of
the rise-time.
[2]
oai:arXiv.org:1108.4632 [pdf] - 1083577
Proximity Effects and Nonequilibrium Superconductivity in
Transition-Edge Sensors
Submitted: 2011-08-23
We have recently shown that normal-metal/superconductor (N/S) bilayer TESs
(superconducting Transition-Edge Sensors) exhibit weak-link behavior.1 Here we
extend our understanding to include TESs with added noise-mitigating
normal-metal structures (N structures). We find TESs with added Au structures
also exhibit weak-link behavior as evidenced by exponential temperature
dependence of the critical current and Josephson-like oscillations of the
critical current with applied magnetic field. We explain our results in terms
of an effect converse to the longitudinal proximity effect (LoPE)1, the lateral
inverse proximity effect (LaiPE), for which the order parameter in the N/S
bilayer is reduced due to the neighboring N structures. Resistance and critical
current measurements are presented as a function of temperature and magnetic
field taken on square Mo/Au bilayer TESs with lengths ranging from 8 to 130
{\mu}m with and without added N structures. We observe the inverse proximity
effect on the bilayer over in-plane distances many tens of microns and find the
transition shifts to lower temperatures scale approximately as the inverse
square of the in- plane N-structure separation distance, without appreciable
broadening of the transition width. We also present evidence for nonequilbrium
superconductivity and estimate a quasiparticle lifetime of 1.8 \times 10-10 s
for the bilayer. The LoPE model is also used to explain the increased
conductivity at temperatures above the bilayer's steep resistive transition.
[3]
oai:arXiv.org:1011.4052 [pdf] - 264469
Science Objectives for an X-Ray Microcalorimeter Observing the Sun
Laming, J. Martin;
Adams, J.;
Alexander, D.;
Aschwanden, M;
Bailey, C.;
Bandler, S.;
Bookbinder, J.;
Bradshaw, S.;
Brickhouse, N.;
Chervenak, J.;
Christe, S.;
Cirtain, J.;
Cranmer, S.;
Deiker, S.;
DeLuca, E.;
Del Zanna, G.;
Dennis, B.;
Doschek, G.;
Eckart, M.;
Fludra, A.;
Finkbeiner, F.;
Grigis, P.;
Harrison, R.;
Ji, L.;
Kankelborg, C.;
Kashyap, V.;
Kelly, D.;
Kelley, R.;
Kilbourne, C.;
Klimchuk, J.;
Ko, Y. -K.;
Landi, E.;
Linton, M.;
Longcope, D.;
Lukin, V.;
Mariska, J.;
Martinez-Galarce, D.;
Mason, H.;
McKenzie, D.;
Osten, R.;
Peres, G.;
Pevtsov, A.;
Porter, K. Phillips F. S.;
Rabin, D.;
Rakowski, C.;
Raymond, J.;
Reale, F.;
Reeves, K.;
Sadleir, J.;
Savin, D.;
Schmelz, J.;
Smith, R. K.;
Smith, S.;
Stern, R.;
Sylwester, J.;
Tripathi, D.;
Ugarte-Urra, I.;
Young, P.;
Warren, H.;
Wood, B.
Submitted: 2010-11-17
We present the science case for a broadband X-ray imager with high-resolution
spectroscopy, including simulations of X-ray spectral diagnostics of both
active regions and solar flares. This is part of a trilogy of white papers
discussing science, instrument (Bandler et al. 2010), and missions (Bookbinder
et al. 2010) to exploit major advances recently made in transition-edge sensor
(TES) detector technology that enable resolution better than 2 eV in an array
that can handle high count rates. Combined with a modest X-ray mirror, this
instrument would combine arcsecondscale imaging with high-resolution spectra
over a field of view sufficiently large for the study of active regions and
flares, enabling a wide range of studies such as the detection of microheating
in active regions, ion-resolved velocity flows, and the presence of non-thermal
electrons in hot plasmas. It would also enable more direct comparisons between
solar and stellar soft X-ray spectra, a waveband in which (unusually) we
currently have much better stellar data than we do of the Sun.
[4]
oai:arXiv.org:astro-ph/0610580 [pdf] - 260805
The optical performance of frequency selective bolometers
Perera, T. A.;
Chen, T. C.;
Cheng, E. S.;
Cottingham, D. A.;
Crawford, T. M.;
Downes, T. P.;
Finkbeiner, F. M.;
Fixsen, D. J.;
Logan, D. W.;
Meyer, S. S.;
Sharp, E. H.;
Silverberg, R. F.;
Wilson, G. W.
Submitted: 2006-10-19
Frequency Selective Bolometers (FSBs) are a new type of detector for
millimeter and sub-millimeter wavelengths that are transparent to all but a
narrow range of frequencies as set by characteristics of the absorber itself.
Therefore, stacks of FSBs tuned to different frequencies provide a low-loss
compact method for utilizing a large fraction of the light collected by a
telescope. Tests of prototype FSBs, described here, indicate that the
absorption spectra are well predicted by models, that peak absolute absorption
efficiencies of order 50% are attainable, and that their out-of-band
transmission is high.