Normalized to: Fink, D.
[1]
oai:arXiv.org:1911.06029 [pdf] - 1998631
Optical intensity interferometry observations using the MAGIC imaging
atmospheric Cherenkov telescopes
Acciari, V. A.;
Bernardos, M. I.;
Colombo, E.;
Contreras, J. L.;
Cortina, J.;
Delgado, C.;
Diaz, C.;
Fink, D.;
Mariotti, M.;
Mangano, S.;
Mirzoyan, R.;
Polo, M.;
Schweizer, T.;
Will, M.
Submitted: 2019-11-14
Imaging Atmospheric Cherenkov Telescopes (IACTs) currently in operation
feature large mirrors and order of 1 ns time response to signals of a few
photo-electrons produced by optical photons. This means that they are ideally
suited for optical interferometry observations. Thanks to their sensitivity to
visible wavelengths and long baselines optical intensity interferometry with
IACTs allows reaching angular resolutions of tens to microarcsec. We have
installed a simple optical setup on top of the cameras of the two 17 m diameter
MAGIC IACTs and observed coherent fluctuations in the photon intensity measured
at the two telescopes for three different stars. The sensitivity is roughly 10
times better than that achieved in the 1970s with the Narrabri interferometer.
[3]
oai:arXiv.org:1709.00239 [pdf] - 1587792
Light-Trap: A SiPM Upgrade for Very High Energy Astronomy and Beyond
Guberman, D.;
Cortina, J.;
Ward, J. E.;
Hahn, A.;
Mazin, D.;
Boix, J.;
Dettlaff, A.;
Fink, D.;
Gaweda, J.;
Haberer, W.;
Illa, J.;
Mundet, J.;
Vera, Y.;
Wetteskind, H.
Submitted: 2017-09-01
With the development of the Imaging Atmospheric Cherenkov Technique (IACT),
Gamma-ray astronomy has become one of the most interesting and productive
fields of astrophysics. Current IACT telescope arrays (MAGIC, H.E.S.S, VERITAS)
use photomultiplier tubes (PMTs) to detect the optical/near-UV Cherenkov
radiation emitted due to the interaction of gamma rays with the atmosphere. For
the next generation of IACT experiments, the possibility of replacing the PMTs
with Silicon photomultipliers (SiPMs) is being studied. Among the main
drawbacks of SiPMs are their limited active area (leading to an increase in the
cost and complexity of the camera readout) and their sensitivity to unwanted
wavelengths. Here we propose a novel method to build a relatively low-cost
pixel consisting of a SiPM attached to a PMMA disc doped with a wavelength
shifter. This pixel collects light over a much larger area than a single
standard SiPM and improves sensitivity to near-UV light while simultaneously
rejecting background. We describe the design of a detector that could also have
applications in other fields where detection area and cost are crucial. We
present results of simulations and laboratory measurements of a pixel prototype
and from field tests performed with a 7-pixel cluster installed in a MAGIC
telescope camera.
[4]
oai:arXiv.org:1708.07698 [pdf] - 1587487
MAGIC sensitivity to millisecond-duration optical pulses
Submitted: 2017-08-25, last modified: 2017-08-28
The MAGIC telescopes are a system of two Imaging Atmospheric Cherenkov
Telescopes (IACTs) designed to observe very high energy (VHE) gamma rays above
~50 GeV. However, as IACTs are sensitive to Cherenkov light in the UV/blue and
use photo-detectors with a time response well below the ms scale, MAGIC is also
able to perform simultaneous optical observations. Through an alternative
system installed in the central PMT of MAGIC II camera, the so-called central
pixel, MAGIC is sensitive to short (1ms - 1s) optical pulses. Periodic signals
from the Crab pulsar are regularly monitored. Here we report for the first time
the experimental determination of the sensitivity of the central pixel to
isolated 1-10 ms long optical pulses. The result of this study is relevant for
searches of fast transients such as Fast Radio Bursts (FRBs).
[7]
oai:arXiv.org:1508.07120 [pdf] - 1938080
Silicon Photomultiplier Research and Development Studies for the Large
Size Telescope of the Cherenkov Telescope Array
Rando, Riccardo;
Corti, Daniele;
Dazzi, Francesco;
De Angelis, Alessandro;
Dettlaff, Antonios;
Dorner, Daniela;
Fink, David;
Fouque, Nadia;
Grundner, Felix;
Haberer, Werner;
Hahn, Alexander;
Hermel, Richard;
Korpar, Samo;
Mezek, Gašper Kukec;
Maier, Ronald;
Manea, Christian;
Mariotti, Mosè;
Mazin, Daniel;
Mehrez, Fatima;
Mirzoyan, Razmik;
Podkladkin, Sergey;
Reichardt, Ignasi;
Rhode, Wolfgang;
Rosier, Sylvie;
Schultz, Cornelia;
Stella, Carlo;
Teshima, Masahiro;
Wetteskind, Holger;
Zavrtanik, Marko
Submitted: 2015-08-28
The Cherenkov Telescope Array (CTA) is the the next generation facility of
imaging atmospheric Cherenkov telescopes; two sites will cover both
hemispheres. CTA will reach unprecedented sensitivity, energy and angular
resolution in very-high-energy gamma-ray astronomy. Each CTA array will include
four Large Size Telescopes (LSTs), designed to cover the low-energy range of
the CTA sensitivity ($\sim$20 GeV to 200 GeV). In the baseline LST design, the
focal-plane camera will be instrumented with 265 photodetector clusters; each
will include seven photomultiplier tubes (PMTs), with an entrance window of 1.5
inches in diameter. The PMT design is based on mature and reliable technology.
Recently, silicon photomultipliers (SiPMs) are emerging as a competitor.
Currently, SiPMs have advantages (e.g. lower operating voltage and tolerance to
high illumination levels) and disadvantages (e.g. higher capacitance and cross
talk rates), but this technology is still young and rapidly evolving. SiPM
technology has a strong potential to become superior to the PMT one in terms of
photon detection efficiency and price per square mm of detector area. While the
advantage of SiPMs has been proven for high-density, small size cameras, it is
yet to be demonstrated for large area cameras such as the one of the LST. We
are working to develop a SiPM-based module for the LST camera, in view of a
possible camera upgrade. We will describe the solutions we are exploring in
order to balance a competitive performance with a minimal impact on the overall
LST camera design.
[8]
oai:arXiv.org:1409.6073 [pdf] - 986943
The major upgrade of the MAGIC telescopes, Part I: The hardware
improvements and the commissioning of the system
MAGIC Collaboration;
Aleksic, J.;
Ansoldi, S.;
Antonelli, L. A.;
Antoranz, P.;
Babic, A.;
Bangale, P.;
Barcelo, M.;
Barrio, J. A.;
Gonzalez, J. Becerra;
Bednarek, W.;
Bernardini, E.;
Biasuzzi, B.;
Biland, A.;
Bitossi, M.;
Blanch, O.;
Bonnefoy, S.;
Bonnoli, G.;
Borracci, F.;
Bretz, T.;
Carmona, E.;
Carosi, A.;
Cecchi, R.;
Colin, P.;
Colombo, E.;
Contreras, J. L.;
Corti, D.;
Cortina, J.;
Covino, S.;
Da Vela, P.;
Dazzi, F.;
De Angelis, A.;
De Caneva, G.;
De Lotto, B.;
Wilhelmi, E. de Ona;
Mendez, C. Delgado;
Dettlaff, A.;
Prester, D. Dominis;
Dorner, D.;
Doro, M.;
Einecke, S.;
Eisenacher, D.;
Elsaesser, D.;
Fidalgo, D.;
Fink, D.;
Fonseca, M. V.;
Font, L.;
Frantzen, K.;
Fruck, C.;
Galindo, D.;
Lopez, R. J. Garcia;
Garczarczyk, M.;
Terrats, D. Garrido;
Gaug, M.;
Giavitto, G.;
Godinovic, N.;
Munoz, A. Gonzalez;
Gozzini, S. R.;
Haberer, W.;
Hadasch, D.;
Hanabata, Y.;
Hayashida, M.;
Herrera, J.;
Hildebrand, D.;
Hose, J.;
Hrupec, D.;
Idec, W.;
Illa, J. M.;
Kadenius, V.;
Kellermann, H.;
Knoetig, M. L.;
Kodani, K.;
Konno, Y.;
Krause, J.;
Kubo, H.;
Kushida, J.;
La Barbera, A.;
Lelas, D.;
Lemus, J. L.;
Lewandowska, N.;
Lindfors, E.;
Lombardi, S.;
Longo, F.;
Lopez, M.;
Lopez-Coto, R.;
Lopez-Oramas, A.;
Lorca, A.;
Lorenz, E.;
Lozano, I.;
Makariev, M.;
Mallot, K.;
Maneva, G.;
Mankuzhiyil, N.;
Mannheim, K.;
Maraschi, L.;
Marcote, B.;
Mariotti, M.;
Martinez, M.;
Mazin, D.;
Menzel, U.;
Miranda, J. M.;
Mirzoyan, R.;
Moralejo, A.;
Munar-Adrover, P.;
Nakajima, D.;
Negrello, M.;
Neustroev, V.;
Niedzwiecki, A.;
Nilsson, K.;
Nishijima, K.;
Noda, K.;
Orito, R.;
Overkemping, A.;
Paiano, S.;
Palatiello, M.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Paredes-Fortuny, X.;
Persic, M.;
Poutanen, J.;
Moroni, P. G. Prada;
Prandini, E.;
Puljak, I.;
Reinthal, R.;
Rhode, W.;
Ribo, M.;
Rico, J.;
Garcia, J. Rodriguez;
Rugamer, S.;
Saito, T.;
Saito, K.;
Satalecka, K.;
Scalzotto, V.;
Scapin, V.;
Schultz, C.;
Schlammer, J.;
Schmidl, S.;
Schweizer, T.;
Sillanpaa, A.;
Sitarek, J.;
Snidaric, I.;
Sobczynska, D.;
Spanier, F.;
Stamerra, A.;
Steinbring, T.;
Storz, J.;
Strzys, M.;
Takalo, L.;
Takami, H.;
Tavecchio, F.;
Tejedor, L. A.;
Temnikov, P.;
Terzic, T.;
Tescaro, D.;
Teshima, M.;
Thaele, J.;
Tibolla, O.;
Torres, D. F.;
Toyama, T.;
Treves, A.;
Vogler, P.;
Wetteskind, H.;
Will, M.;
Zanin, R.
Submitted: 2014-09-21, last modified: 2015-04-30
The MAGIC telescopes are two Imaging Atmospheric Cherenkov Telescopes (IACTs)
located on the Canary island of La Palma. The telescopes are designed to
measure Cherenkov light from air showers initiated by gamma rays in the energy
regime from around 50 GeV to more than 50 TeV. The two telescopes were built in
2004 and 2009, respectively, with different cameras, triggers and readout
systems. In the years 2011-2012 the MAGIC collaboration undertook a major
upgrade to make the stereoscopic system uniform, improving its overall
performance and easing its maintenance. In particular, the camera, the
receivers and the trigger of the first telescope were replaced and the readout
of the two telescopes was upgraded. This paper (Part I) describes the details
of the upgrade as well as the basic performance parameters of MAGIC such as raw
data treatment, dead time of the system, linearity in the electronic chain and
sources of noise. In Part II, we describe the physics performance of the
upgraded system.
[9]
oai:arXiv.org:1409.5594 [pdf] - 938161
The major upgrade of the MAGIC telescopes, Part II: A performance study
using observations of the Crab Nebula
MAGIC Collaboration;
Aleksic, J.;
Ansoldi, S.;
Antonelli, L. A.;
Antoranz, P.;
Babic, A.;
Bangale, P.;
Barcelo, M.;
Barrio, J. A.;
Gonzalez, J. Becerra;
Bednarek, W.;
Bernardini, E.;
Biasuzzi, B.;
Biland, A.;
Bitossi, M.;
Blanch, O.;
Bonnefoy, S.;
Bonnoli, G.;
Borracci, F.;
Bretz, T.;
Carmona, E.;
Carosi, A.;
Cecchi, R.;
Colin, P.;
Colombo, E.;
Contreras, J. L.;
Corti, D.;
Cortina, J.;
Covino, S.;
Da Vela, P.;
Dazzi, F.;
De Angelis, A.;
De Caneva, G.;
De Lotto, B.;
Wilhelmi, E. de Ona;
Mendez, C. Delgado;
Dettlaff, A.;
Prester, D. Dominis;
Dorner, D.;
Doro, M.;
Einecke, S.;
Eisenacher, D.;
Elsaesser, D.;
Fidalgo, D.;
Fink, D.;
Fonseca, M. V.;
Font, L.;
Frantzen, K.;
Fruck, C.;
Galindo, D.;
Lopez, R. J. Garcia;
Garczarczyk, M.;
Terrats, D. Garrido;
Gaug, M.;
Giavitto, G.;
Godinovic, N.;
Munoz, A. Gonzalez;
Gozzini, S. R.;
Haberer, W.;
Hadasch, D.;
Hanabata, Y.;
Hayashida, M.;
Herrera, J.;
Hildebrand, D.;
Hose, J.;
Hrupec, D.;
Idec, W.;
Illa, J. M.;
Kadenius, V.;
Kellermann, H.;
Knoetig, M. L.;
Kodani, K.;
Konno, Y.;
Krause, J.;
Kubo, H.;
Kushida, J.;
La Barbera, A.;
Lelas, D.;
Lemus, J. L.;
Lewandowska, N.;
Lindfors, E.;
Lombardi, S.;
Longo, F.;
Lopez, M.;
Lopez-Coto, R.;
Lopez-Oramas, A.;
Lorca, A.;
Lorenz, E.;
Lozano, I.;
Makariev, M.;
Mallot, K.;
Maneva, G.;
Mankuzhiyil, N.;
Mannheim, K.;
Maraschi, L.;
Marcote, B.;
Mariotti, M.;
Martinez, M.;
Mazin, D.;
Menzel, U.;
Miranda, J. M.;
Mirzoyan, R.;
Moralejo, A.;
Munar-Adrover, P.;
Nakajima, D.;
Negrello, M.;
Neustroev, V.;
Niedzwiecki, A.;
Nilsson, K.;
Nishijima, K.;
Noda, K.;
Orito, R.;
Overkemping, A.;
Paiano, S.;
Palatiello, M.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Paredes-Fortuny, X.;
Persic, M.;
Poutanen, J.;
Moroni, P. G. Prada;
Prandini, E.;
Puljak, I.;
Reinthal, R.;
Rhode, W.;
Ribo, M.;
Rico, J.;
Garcia, J. Rodriguez;
Rugamer, S.;
Saito, T.;
Saito, K.;
Satalecka, K.;
Scalzotto, V.;
Scapin, V.;
Schultz, C.;
Schlammer, J.;
Schmidl, S.;
Schweizer, T.;
Shore, S. N.;
Sillanpaa, A.;
Sitarek, J.;
Snidaric, I.;
Sobczynska, D.;
Spanier, F.;
Stamerra, A.;
Steinbring, T.;
Storz, J.;
Strzys, M.;
Takalo, L.;
Takami, H.;
Tavecchio, F.;
Tejedor, L. A.;
Temnikov, P.;
Terzic, T.;
Tescaro, D.;
Teshima, M.;
Thaele, J.;
Tibolla, O.;
Torres, D. F.;
Toyama, T.;
Treves, A.;
Vogler, P.;
Wetteskind, H.;
Will, M.;
Zanin, R.
Submitted: 2014-09-19, last modified: 2015-02-20
MAGIC is a system of two Imaging Atmospheric Cherenkov Telescopes located in
the Canary island of La Palma, Spain. During summer 2011 and 2012 it underwent
a series of upgrades, involving the exchange of the MAGIC-I camera and its
trigger system, as well as the upgrade of the readout system of both
telescopes. We use observations of the Crab Nebula taken at low and medium
zenith angles to assess the key performance parameters of the MAGIC stereo
system. For low zenith angle observations, the standard trigger threshold of
the MAGIC telescopes is ~50GeV. The integral sensitivity for point-like sources
with Crab Nebula-like spectrum above 220GeV is (0.66+/-0.03)% of Crab Nebula
flux in 50 h of observations. The angular resolution, defined as the sigma of a
2-dimensional Gaussian distribution, at those energies is < 0.07 degree, while
the energy resolution is 16%. We also re-evaluate the effect of the systematic
uncertainty on the data taken with the MAGIC telescopes after the upgrade. We
estimate that the systematic uncertainties can be divided in the following
components: < 15% in energy scale, 11-18% in flux normalization and +/-0.15 for
the energy spectrum power-law slope.
[10]
oai:arXiv.org:1410.5070 [pdf] - 884642
Towards SiPM camera for current and future generations of Cherenkov
telescopes
Mazin, Daniel;
Bangale, Priyadarshini;
Sitarek, Julian;
Cortina, Juan;
Fink, David;
Hose, Jürgen;
Illa, Jose Maria;
Lorenz, Eckart;
Martínez, Manel;
Menzel, Uta;
Mirzoyan, Razmik;
Teshima, Masahiro
Submitted: 2014-10-19
So far the current ground-based Imaging Atmospheric Cherenkov Telescopes
(IACTs) have energy thresholds in the best case in the range of ~30 to 50 GeV
(H.E.S.S. II and MAGIC telescopes). Lowest energy gamma-ray showers produce low
light intensity images and cannot be efficiently separated from dominating
images from hadronic background. A cost effective way of improving the
telescope performance at lower energies is to use novel photosensors with
superior photon detection efficiency (PDE). Currently the best commercially
available superbialkali photomultipliers (PMTs) have a PDE of about 30-33%,
whereas the silicon photomultipliers (SiPMs, also known as MPPC, GAPD) from
some manufacturers show a photon detection efficiency of about 40-45%. Using
these devices can lower the energy threshold of the instrument and may improve
the background rejection due to intrinsic properties of SiPMs such as a superb
single photoelectron resolution. Compared to PMTs, SiPMs are more compact, fast
in response, operate at low voltage, and are insensitive to magnetic fields.
SiPMs can be operated at high background illumination, which would allow to
operate the IACT also during partial moonlight, dusk and dawn, hence increasing
the instrument duty cycle. We are testing the SiPMs for Cherenkov telescopes
such as MAGIC and CTA. Here we present an overview of our setup and first
measurements, which we perform in two independent laboratories, in Munich,
Germany and in Barcelona, Spain.
[12]
oai:arXiv.org:1307.4565 [pdf] - 1937883
The Cherenkov Telescope Array Large Size Telescope
Ambrosi, G.;
Awane, Y.;
Baba, H.;
Bamba, A.;
Barceló, M.;
de Almeida, U. Barres;
Barrio, J. A.;
Bigas, O. Blanch;
Boix, J.;
Brunetti, L.;
Carmona, E.;
Chabanne, E.;
Chikawa, M.;
Colin, P.;
Conteras, J. L.;
Cortina, J.;
Dazzi, F.;
Deangelis, A.;
Deleglise, G.;
Delgado, C.;
Díaz, C.;
Dubois, F.;
Fiasson, A.;
Fink, D.;
Fouque, N.;
Freixas, L.;
Fruck, C.;
Gadola, A.;
García, R.;
Gascon, D.;
Geffroy, N.;
Giglietto, N.;
Giordano, F.;
Grañena, F.;
Gunji, S.;
Hagiwara, R.;
Hamer, N.;
Hanabata, Y.;
Hassan, T.;
Hatanaka, K.;
Haubold, T.;
Hayashida, M.;
Hermel, R.;
Herranz, D.;
Hirotani, K.;
Inoue, S.;
Inoue, Y.;
Ioka, K.;
Jablonski, C.;
Kagaya, M.;
Katagiri, H.;
Kishimoto, T.;
Kodani, K.;
Kohri, K.;
Konno, Y.;
Koyama, S.;
Kubo, H.;
Kushida, J.;
Lamanna, G.;
Flour, T. Le;
López-Moya, M.;
López, R.;
Lorenz, E.;
Majumdar, P.;
Manalaysay, A.;
Mariotti, M.;
Martínez, G.;
Martínez, M.;
Mazin, D.;
Miranda, J. M.;
Mirzoyan, R.;
Monteiro, I.;
Moralejo, A.;
Murase, K.;
Nagataki, S.;
Nakajima, D.;
Nakamori, T.;
Nishijima, K.;
Noda, K.;
Nozato, A.;
Ohira, Y.;
Ohishi, M.;
Ohoka, H.;
Okumura, A.;
Orito, R.;
Panazol, J. L.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Pauletta, G.;
Podkladkin, S.;
Prast, J.;
Rando, R.;
Reimann, O.;
Ribó, M.;
Rosier-Lees, S.;
Saito, K.;
Saito, T.;
Saito, Y.;
Sakaki, N.;
Sakonaka, R.;
Sanuy, A.;
Sasaki, H.;
Sawada, M.;
Scalzotto, V.;
Schultz, S.;
Schweizer, T.;
Shibata, T.;
Shu, S.;
Sieiro, J.;
Stamatescu, V.;
Steiner, S.;
Straumann, U.;
Sugawara, R.;
Tajima, H.;
Takami, H.;
Tanaka, S.;
Tanaka, M.;
Tejedor, L. A.;
Terada, Y.;
Teshima, M.;
Totani, T.;
Ueno, H.;
Umehara, K.;
Vollhardt, A.;
Wagner, R.;
Wetteskind, H.;
Yamamoto, T.;
Yamazaki, R.;
Yoshida, A.;
Yoshida, T.;
Yoshikoshi, T.
Submitted: 2013-07-17
The two arrays of the Very High Energy gamma-ray observatory Cherenkov
Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with
a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA
to achieve a low-energy threshold of 20 GeV, which is critical for important
studies in astrophysics, astroparticle physics and cosmology. This work
presents the key specifications and performance of the current LST design in
the light of the CTA scientific objectives.
[13]
oai:arXiv.org:1307.3386 [pdf] - 1937869
Development of the Photomultiplier-Tube Readout System for the CTA Large
Size Telescope
Kubo, H.;
Paoletti, R.;
Awane, Y.;
Bamba, A.;
Barcelo, M.;
Barrio, J. A.;
Blanch, O.;
Boix, J.;
Delgado, C.;
Fink, D.;
Gascon, D.;
Gunji, S.;
Hagiwara, R.;
Hanabata, Y.;
Hatanaka, K.;
Hayashida, M.;
Ikeno, M.;
Kabuki, S.;
Katagiri, H.;
Kataoka, J.;
Konno, Y.;
Koyama, S.;
Kishimoto, T.;
Kushida, J.;
Martinez, G.;
Masuda, S.;
Miranda, J. M.;
Mirzoyan, R.;
Mizuno, T.;
Nagayoshi, T.;
Nakajima, D.;
Nakamori, T.;
Ohoka, H.;
Okumura, A.;
Orito, R.;
Saito, T.;
Sanuy, A.;
Sasaki, H.;
Sawada, M.;
Schweizer, T.;
Sugawara, R.;
Sulanke, K. -H.;
Tajima, H.;
Tanaka, M.;
Tanaka, S.;
Tejedor, L. A.;
Terada, Y.;
Teshima, M.;
Tokanai, F.;
Tsuchiya, Y.;
Uchida, T.;
Ueno, H.;
Umehara, K.;
Yamamoto, T.
Submitted: 2013-07-12
We have developed a prototype of the photomultiplier tube (PMT) readout
system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two
thousand PMTs along with their readout systems are arranged on the focal plane
of each telescope, with one readout system per 7-PMT cluster. The Cherenkov
light pulses generated by the air showers are detected by the PMTs and
amplified in a compact, low noise and wide dynamic range gain block. The output
of this block is then digitized at a sampling rate of the order of GHz using
the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer
Institute. The sampler has 1,024 capacitors per channel and four channels are
cascaded for increased depth. After a trigger is generated in the system, the
charges stored in the capacitors are digitized by an external slow sampling ADC
and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4,
trigger threshold, and Ethernet transfer. In addition, the control and
monitoring of the Cockcroft-Walton circuit that provides high voltage for the
7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been
developed that has successfully sampled PMT signals at a rate of 2 GHz, and
generated single photoelectron spectra.
[14]
oai:arXiv.org:0907.0865 [pdf] - 1934383
Development of HPD Clusters for MAGIC-II
Orito, R.;
Bernardini, E.;
Bose, D.;
Dettlaff, A.;
Fink, D.;
Fonseca, V.;
Hayashida, M.;
Hose, J.;
Lorenz, E.;
Mannheim, K.;
Mirzoyan, R.;
Reimann, O.;
Saito, T. Y.;
Schweizer, T.;
Shayduk, M.;
Teshima, M.
Submitted: 2009-07-05
MAGIC-II is the second imaging atmospheric Cherenkov telescope of the MAGIC
observatory, which has recently been inaugurated on Canary island of La Palma.
We are currently developing a new camera based on clusters of hybrid photon
detectors (HPD) for the upgrade of MAGIC-II. The photon detectors feature a
GaAsP photocathode and an avalanche diode as electron bombarded anodes with
internal gain, and were supplied by Hamamatsu Photonics K.K. (R9792U-40). The
HPD camera with high quantum efficiency will increase the MAGIC-II sensitivity
and lower the energy threshold. The basic performance of the HPDs has been
measured and a prototype of an HPD cluster has been developed to be mounted on
MAGIC-II. Here we report on the status of the HPD cluster and the project of
eventually using HPD clusters in the central area of the MAGIC-II camera.
[15]
oai:arXiv.org:0906.5448 [pdf] - 1934350
Performance of the Camera of the MAGIC II Telescope
Tridon, D. Borla;
Goebel, F.;
Fink, D.;
Haberer, W.;
Hose, J.;
Hsu, C. C.;
Jogler, T.;
Mirzoyan, R.;
Orito, R.;
Reimann, O.;
Sawallisch, P.;
Schlammer, J.;
Schweizer, T.;
Steinke, B.;
Teshima, M.
Submitted: 2009-06-30
MAGIC comprises two 17m diameter IACTs to be operated in stereo mode.
Currently we are commissioning the second telescope, MAGIC II. The camera of
the second telescope has been equipped with 1039 pixels of 0.1-degree diameter.
Always seven pixels are grouped in a hexagonal configuration to form a cluster.
This modular design allows easier control and maintenance of the camera. The
pixel sensors are high quantum efficiency photomultiplier tubes (PMTs) from
Hamamatsu (superbialkali type, QE ~ 32% at the peak wavelength) that we operate
at rather low gain of 30 k. This allows us to also perform extended
observations under moderate moonlight. The system of two MAGIC telescopes will
at least double the sensitivity compared to MAGIC I and also will allow us to
lower the energy threshold.Here we will report the performances of the Camera
of the second MAGIC telescope.
[16]
oai:arXiv.org:0709.2474 [pdf] - 5005
The Camera of the MAGIC-II Telescope
Hsu, C. C.;
Dettlaff, A.;
Fink, D.;
Goebel, F.;
Haberer, W.;
Hose, J.;
Maier, R.;
Mirzoyan, R.;
Pimpl, W.;
Reimann, O.;
Rudert, A.;
Sawallisch, P.;
Schlammer, J.;
Schmidl, S.;
Stipp, A.;
Teshima, M.
Submitted: 2007-09-16
The MAGIC 17m diameter Cherenkov telescope will be upgraded with a second
telescope within the year 2007. The camera of MAGIC-II will include several new
features compared to the MAGIC-I camera. Photomultipliers with the highest
available photon collection efficiency have been selected. A modular design
allows easier access and flexibility to test new photodetector technologies.
The camera will be uniformly equipped with 0.1 degree diamter pixels, which
allows the use of an increased trigger area. Finally, the overall signal chain
features a large bandwidth to retain the shape of the very fast Cherenkov
signals.