Normalized to: Figini, L.
[1]
oai:arXiv.org:1001.4633 [pdf] - 33153
Planck LFI flight model feed horns
Villa, F.;
D'Arcangelo, O.;
Pecora, M.;
Figini, L.;
Nesti, R.;
Simonetto, A.;
Sozzi, C.;
Sandri, M.;
Battaglia, P.;
Guzzi, P.;
Bersanelli, M.;
Butler, R. C.;
Mandolesi, N.
Submitted: 2010-01-26
this paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency
Instrument is optically interfaced with the ESA Planck telescope through 11
corrugated feed horns each connected to the Radiometer Chain Assembly (RCA).
This paper describes the design, the manufacturing and the testing of the
flight model feed horns. They have been designed to optimize the LFI optical
interfaces taking into account the tight mechanical requirements imposed by the
Planck focal plane layout. All the eleven units have been successfully tested
and integrated with the Ortho Mode transducers.
[2]
oai:arXiv.org:1001.4711 [pdf] - 33175
The Planck-LFI flight model composite waveguides
D'Arcangelo, O.;
Figini, L.;
Simonetto, A.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Mennella, A.;
Morgante, G.;
Pagan, L.;
Valenziano, L.
Submitted: 2010-01-26
The Low Frequency Instrument on board the PLANCK satellite is designed to
give the most accurate map ever of the CMB anisotropy of the whole sky over a
broad frequency band spanning 27 to 77 GHz. It is made of an array of 22
pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End
Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between
the two parts is made with rectangular Wave Guides. Considerations of different
nature (thermal, electromagnetic and mechanical), imposed stringent
requirements on the WGs characteristics and drove their design. From the
thermal point of view, the WG should guarantee good insulation between the FEM
and the BEM sections to avoid overloading the cryocooler. On the other hand it
is essential that the signals do not undergo excessive attenuation through the
WG. Finally, given the different positions of the FEM modules behind the focal
surface and the mechanical constraints given by the surrounding structures,
different mechanical designs were necessary. A composite configuration of
Stainless Steel and Copper was selected to satisfy all the requirements. Given
the complex shape and the considerable length (about 1.5-2 m), manufacturing
and testing the WGs was a challenge. This work deals with the development of
the LFI WGs, including the choice of the final configuration and of the
fabrication process. It also describes the testing procedure adopted to fully
characterize these components from the electromagnetic point of view and the
space qualification process they underwent. Results obtained during the test
campaign are reported and compared with the stringent requirements. The
performance of the LFI WGs is in line with requirements, and the WGs were
successfully space qualified.
[3]
oai:arXiv.org:1001.4686 [pdf] - 1477095
The PLANCK LFI flight model ortho-mode transducers
D'Arcangelo, O.;
Simonetto, A.;
Figini, L.;
Pagana, E.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Sozzi, C.
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array
of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70
GHz. LFI has been calibrated and delivered for integration with the satellite
to the European Space Agency on November 2006. The aim of Planck is to measure
the anisotropy and polarization of the Cosmic Background Radiation with a
sensitivity and angular resolution never reached before over the full sky. LFI
is intrinsically sensitive to polarization thanks to the use of Ortho-Mode
Transducers (OMT) located between the feedhorns and the pseudo-correlation
radiometers. The OMTs are microwave passive components that divide the incoming
radiation into two linear orthogonal components. A set of 11 OMTs (2 at 30 GHz,
3 at 44 GHz, and 6 at 70 GHz) were produced and tested. This work describes the
design, development and performance of the eleven Flight Model OMTs of LFI. The
final design was reached after several years of development. At first, Elegant
Bread Board OMTs were produced to investigate the manufacturing technology and
design requirements. Then, a set of 3 Qualification Model (QM) OMTs were
designed, manufactured and tested in order to freeze the design and the
manufacturing technology for the flight units. Finally, the Flight Models were
produced and tested. It is shown that all the OMT units have been accepted for
flight and the electromagnetic performance is at least marginally compliant
with the requirements. Mechanically, the units passed all the thermoelastic
qualification tests after a reworking necessary after the QM campaign.
[4]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.