Normalized to: Fields, N.
[1]
oai:arXiv.org:1407.7524 [pdf] - 903589
Coherent neutrino-nucleus scattering detection with a CsI[Na]
scintillator at the SNS spallation source
Submitted: 2014-07-28, last modified: 2014-08-20
We study the possibility of using CsI[Na] scintillators as an advantageous
target for the detection of coherent elastic neutrino-nucleus scattering
(CENNS), using the neutrino emissions from the SNS spallation source at Oak
Ridge National Laboratory. The response of this material to low-energy nuclear
recoils like those expected from this process is characterized. Backgrounds are
studied using a 2 kg low-background prototype crystal in a dedicated radiation
shield. The conclusion is that a planned 14 kg detector should measure
approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr
low-energy threshold, with a signal-to-background ratio sufficient for a first
measurement of the CENNS cross-section. The cross-section for the
$^{208}$Pb($\nu_{e},e^{-}$)$^{208}$Bi reaction, of interest for future
supernova neutrino detection, can be simultaneously obtained.
[2]
oai:arXiv.org:1401.3295 [pdf] - 770398
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter
Detector Data
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2014-01-14
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter
candidates. WIMP interactions with sensitive detectors are expected to display
a characteristic annual modulation in rate. We release a dataset spanning 3.4
years of operation from a low-background germanium detector, designed to search
for this signature. A previously reported modulation persists, concentrated in
a region of the energy spectrum populated by an exponential excess of unknown
origin. Its phase and period agree with phenomenological expectations, but its
amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP
galactic halo. We consider the possibility of a non-Maxwellian local halo
velocity distribution as a plausible explanation, able to help reconcile
recently reported WIMP search anomalies.
[3]
oai:arXiv.org:1208.5737 [pdf] - 690015
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact
Germanium Detectors
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2012-08-28, last modified: 2013-04-29
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for
Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy
threshold and ability to reject surface backgrounds, this type of device allows
an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2).
We report on the characteristics of the PPC detector presently taking data at
the Soudan Underground Laboratory, elaborating on aspects of shielding, data
acquisition, instrumental stability, data analysis, and background estimation.
A detailed background model is used to investigate the low energy excess of
events previously reported, and to assess the possibility of temporal
modulations in the low-energy event rate. Extensive simulations of all
presently known backgrounds do not provide a viable background explanation for
the excess of low-energy events in the CoGeNT data, or the previously observed
temporal variation in the event rate. Also reported on for the first time is a
determination of the surface (slow pulse rise time) event contamination in the
data as a function of energy. We conclude that the CoGeNT detector technology
is well suited to search for the annual modulation signature expected from dark
matter particle interactions in the region of WIMP mass and coupling favored by
the DAMA/LIBRA results
[4]
oai:arXiv.org:1210.6282 [pdf] - 1152380
The C-4 Dark Matter Experiment
Bonicalzi, R. M.;
Collar, J. I.;
Colaresi, J.;
Fast, J. E.;
Fields, N. E.;
Fuller, E. S.;
Hai, M.;
Hossbach, T. W.;
Kos, M. S.;
Orrell, J. L.;
Overman, C. T.;
Reid, D. J.;
VanDevender, B. A.;
Wiseman, C.;
Yocum, K. M.
Submitted: 2012-10-23, last modified: 2013-02-07
We describe the experimental design of C-4, an expansion of the CoGeNT dark
matter search to four identical detectors each approximately three times the
mass of the p-type point contact germanium diode presently taking data at the
Soudan Underground Laboratory. Expected reductions of radioactive backgrounds
and energy threshold are discussed, including an estimate of the additional
sensitivity to low-mass dark matter candidates to be obtained with this search.
[5]
oai:arXiv.org:1204.3559 [pdf] - 503190
A Maximum Likelihood Analysis of Low-Energy CDMS Data
Submitted: 2012-04-16, last modified: 2012-04-21
An unbinned maximum likelihood analysis of CDMS low-energy data reveals a
strong preference (5.7 sigma C.L.) for a model containing an exponential excess
of events in the nuclear recoil band, when compared to the null hypothesis. We
comment on the possible origin of such an excess, establishing a comparison
with anomalies in other dark matter experiments. A recent annual modulation
search in CDMS data is shown to be insufficiently sensitive to test a dark
matter origin for this excess.
[6]
oai:arXiv.org:1106.0650 [pdf] - 669552
Search for an Annual Modulation in a P-type Point Contact Germanium Dark
Matter Detector
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Knecht, A.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2011-06-03, last modified: 2011-10-04
Fifteen months of cumulative CoGeNT data are examined for indications of an
annual modulation, a predicted signature of Weakly Interacting Massive Particle
(WIMP) interactions. Presently available data support the presence of a
modulated component of unknown origin, with parameters prima facie compatible
with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield
a statistical significance for a modulation of ~2.8 sigma, limited by the short
exposure.
[7]
oai:arXiv.org:1002.4703 [pdf] - 339357
Results from a Search for Light-Mass Dark Matter with a P-type Point
Contact Germanium Detector
Aalseth, C. E.;
Barbeau, P. S.;
Bowden, N. S.;
Cabrera-Palmer, B.;
Colaresi, J.;
Collar, J. I.;
Dazeley, S.;
de Lurgio, P.;
Drake, G.;
Fast, J. E.;
Fields, N.;
Greenberg, C. H.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Reyna, D.;
Robertson, R. G. H.;
Talaga, R. L.;
Tench, O.;
Van Wechel, T. D.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2010-02-25, last modified: 2010-03-15
We report on several features present in the energy spectrum from an ultra
low-noise germanium detector operated at 2,100 m.w.e. By implementing a new
technique able to reject surface events, a number of cosmogenic peaks can be
observed for the first time. We discuss several possible causes for an
irreducible excess of bulk-like events below 3 keVee, including a dark matter
candidate common to the DAMA/LIBRA annual modulation effect, the hint of a
signal in CDMS, and phenomenological predictions. Improved constraints are
placed on a cosmological origin for the DAMA/LIBRA effect.
[8]
oai:arXiv.org:0901.1225 [pdf] - 315476
Multiwavelength Observations of Markarian 421 in 2005 - 2006
Horan, D.;
Acciari, V. A.;
Bradbury, S. M.;
Buckley, J. H.;
Bugaev, V.;
Byrum, K. L.;
Cannon, A.;
Celik, O.;
Cesarini, A.;
Chow, Y. C. K.;
Ciupik, L.;
Cogan, P.;
Falcone, A. D.;
Fegan, S. J.;
Finley, J. P.;
Fortin, P.;
Fortson, L. F.;
Gall, D.;
Gillanders, G. H.;
Grube, J.;
Gyuk, G.;
Hanna, D.;
Hays, E.;
Kertzman, M.;
Kildea, J.;
Konopelko, A.;
Krawczynski, H.;
F.;
Lang, M. J.;
Lee, K.;
Moriarty, P.;
Nagai, T.;
Niemiec, J.;
Ong, R. A.;
Perkins, J. S.;
Pohl, M.;
Quinn, J.;
Reynolds, P. T.;
Rose, H. J.;
Sembroski, G. H.;
Smith, A. W.;
Steele, D.;
Swordy, S. P.;
Toner, J. A.;
Vassiliev, V. V.;
Wakely, S. P.;
Weekes, T. C.;
White, R. J.;
Williams, D. A.;
Wood, M. D.;
Zitzer, B.;
Aller, H. D.;
Aller, M. F.;
Baker, M.;
Barnaby, D.;
Carini, M. T.;
Charlot, P.;
Dumm, J. P.;
Fields, N. E.;
Hovatta, T.;
Jordan, B.;
Kovalev, Y. A.;
Kovalev, Y. Y.;
Krimm, H. A.;
Kurtanidze, O. M.;
Lahteenmaki, A.;
Campion, J. F. Le;
Maune, J.;
Montaruli, T.;
Sadun, A. C.;
Smith, S.;
Tornikoski, M.;
Turunen, M.;
Walters, R.
Submitted: 2009-01-09
Since September 2005, the Whipple 10m Gamma-ray Telescope has been operated
primarily as a blazar monitor. The five Northern Hemisphere blazars that have
already been detected at the Whipple Observatory, Markarian 421, H1426+428,
Markarian 501, 1ES 1959+650 and 1ES 2344+514, are monitored routinely each
night that they are visible. We report on the Markarian 421 observations taken
from November 2005 to June 2006 in the gamma-ray, X-ray, optical and radio
bands. During this time, Markarian 421 was found to be variable at all
wavelengths probed. Both the variability and the correlations among different
energy regimes are studied in detail here. A tentative correlation, with large
spread, was measured between the X-ray and gamma-ray bands, while no clear
correlation was evident among the other energy bands. In addition to this, the
well-sampled spectral energy distribution of Markarian 421 (1101+384) is
presented for three different activity levels. The observations of the other
blazar targets will be reported separately.