Normalized to: Ficorella, F.
[1]
oai:arXiv.org:1812.02432 [pdf] - 1795973
HERMES: An ultra-wide band X and gamma-ray transient monitor on board a
nano-satellite constellation
Fuschino, F.;
Campana, R.;
Labanti, C.;
Evangelista, Y.;
Feroci, M.;
Burderi, L.;
Fiore, F.;
Ambrosino, F.;
Baldazzi, G.;
Bellutti, P.;
Bertacin, R.;
Bertuccio, G.;
Borghi, G.;
Cirrincione, D.;
Cauz, D.;
Di Salvo, T.;
Ficorella, F.;
Fiorini, M.;
Gambino, A.;
Gandola, M.;
Grassi, M.;
Guzman, A.;
Iaria, R.;
La Rosa, G.;
Lavagna, M.;
Lunghi, P.;
Malcovati, P.;
Maselli, A.;
Menna, M. T.;
Morgante, G.;
Negri, B.;
Papitto, A.;
Pauletta, G.;
Piazzolla, R.;
Picciotto, A.;
Pirrotta, S.;
Pliego-Caballero, S.;
Puccetti, S.;
Rachevski, A.;
Rashevskaya, I.;
Riggio, A.;
Rignanese, L.;
Salatti, M.;
Sanna, A.;
Santangelo, A.;
Silvestrini, S.;
Sottile, G.;
Tenzer, C.;
Vacchi, A.;
Zampa, G.;
Zampa, N.;
Zorzi, N.
Submitted: 2018-12-06, last modified: 2018-12-11
The High Energy Modular Ensemble of Satellites (HERMES) project is aimed to
realize a modular X/gamma-ray monitor for transient events, to be placed
on-board of a CubeSat bus. This expandable platform will achieve a significant
impact on Gamma Ray Burst (GRB) science and on the detection of Gravitational
Wave (GW) electromagnetic counterparts: the recent LIGO/VIRGO discoveries
demonstrated that the high-energy transient sky is still a field of extreme
interest. The very complex temporal variability of GRBs (up to the millisecond
scale) combined with the spatial and temporal coincidence between GWs and their
electromagnetic counterparts suggest that upcoming instruments require sub-ms
time resolution combined with a transient localization accuracy lower than a
degree. The current phase of the ongoing HERMES project is focused on the
realization of a technological pathfinder with a small network (3 units) of
nano-satellites to be launched in mid 2020. We will show the potential and
prospects for short and medium-term development of the project, demonstrating
the disrupting possibilities for scientific investigations provided by the
innovative concept of a new "modular astronomy" with nano-satellites (e.g. low
developing costs, very short realization time). Finally, we will illustrate the
characteristics of the HERMES Technological Pathfinder project, demonstrating
how the scientific goals discussed are actually already reachable with the
first nano-satellites of this constellation. The detector architecture will be
described in detail, showing that the new generation of scintillators (e.g.
GAGG:Ce) coupled with very performing Silicon Drift Detectors (SDD) and low
noise Front-End-Electronics (FEE) are able to extend down to few keV the
sensitivity band of the detector. The technical solutions for FEE,
Back-End-Electronics (BEE) and Data Handling will be also described.
[2]
oai:arXiv.org:1808.08041 [pdf] - 1756027
Characterization of a novel pixelated Silicon Drift Detector (PixDD) for
high-throughput X-ray astrophysics
Evangelista, Y.;
Ambrosino, F.;
Feroci, M.;
Bellutti, P.;
Bertuccio, G.;
Borghi, G.;
Campana, R.;
Caselle, M.;
Cirrincione, D.;
Ficorella, F.;
Fiorini, M.;
Fuschino, F.;
Gandola, M.;
Grassi, M.;
Labanti, C.;
Malcovati, P.;
Mele, F.;
Morbidini, A.;
Picciotto, A.;
Rachevski, A.;
Rashevskaya, I.;
Sammartini, M.;
Zampa, G.;
Zampa, N.;
Zorzi, N.;
Vacchi, A.
Submitted: 2018-08-24, last modified: 2018-08-29
Multi-pixel fast silicon detectors represent the enabling technology for the
next generation of space-borne experiments devoted to high-resolution
spectral-timing studies of low-flux compact cosmic sources. Several imaging
detectors based on frame-integration have been developed as focal plane devices
for X-ray space-borne missions but, when coupled to large-area concentrator
X-ray optics, these detectors are affected by strong pile-up and dead-time
effects, thus limiting the time and energy resolution as well as the overall
system sensitivity. The current technological gap in the capability to realize
pixelated silicon detectors for soft X-rays with fast, photon-by-photon
response and nearly Fano-limited energy resolution therefore translates into
the unavailability of sparse read-out sensors suitable for high throughput
X-ray astronomy applications. In the framework of the ReDSoX Italian
collaboration, we developed a new, sparse read-out, pixelated silicon drift
detector which operates in the energy range 0.5-15 keV with nearly Fano-limited
energy resolution ($\leq$150 eV FWHM @ 6 keV) at room temperature or with
moderate cooling ($\sim$0 {\deg}C to +20 {\deg}C). In this paper, we present
the design and the laboratory characterization of the first 16-pixel
(4$\times$4) drift detector prototype (PixDD), read-out by individual ultra
low-noise charge sensitive preamplifiers (SIRIO) and we discuss the future
PixDD prototype developments.
[3]
oai:arXiv.org:1807.11269 [pdf] - 1724303
The Large Area Detector onboard the eXTP mission
Feroci, Marco;
Ahangarianabhari, Mahdi;
Ambrosi, Giovanni;
Ambrosino, Filippo;
Argan, Andrea;
Barbera, Marco;
Bayer, Joerg;
Bellutti, Pierluigi;
Bertucci, Bruna;
Bertuccio, Giuseppe;
Borghi, Giacomo;
Bozzo, Enrico;
Cadoux, Franck;
Campana, Riccardo;
Ceraudo, Francesco;
Chen, Tianxiang;
Cirrincione, Daniela;
De Rosa, Alessandra;
Del Monte, Ettore;
Di Cosimo, Sergio;
Diebold, Sebastian;
Evangelista, Yuri;
Fan, Qingmei;
Favre, Yannick;
Ficorella, Francesco;
Fuschino, Fabio;
Gevin, Olivier;
Grassi, Marco;
Hong, Bin;
Mao, Hanqi;
Karas, Vladimir;
Kennedy, Tom;
Labanti, Claudio;
Limousin, Olivier;
Cicero, Ugo Lo;
Lu, Fang-Jun;
Luo, Tao;
Malcovati, Piero;
Martindale, Adrian;
Meuris, Aline;
Michalska, Malgorzata;
Morbidini, Alfredo;
Muleri, Fabio;
Orleanski, Piotr;
Paltani, Stephane;
Pan, Teng;
Perinati, Emanuele;
Picciotto, Antonino;
Pohl, Martin;
Rashevskaia, Irina;
Santangelo, Andrea;
Schanne, Stephane;
Skup, Konrad;
Svoboda, Jiri;
Tenzer, Chris;
Vacchi, Andrea;
Walton, Dave;
Winter, Berend;
Wu, Xin;
Xu, Yupeng;
Zampa, Ganluigi;
Zampa, Nicola;
Zane, Silvia;
Zdziarski, Andrzej;
Zhang, Long;
Zhang, Shu;
Zhang, Shuang-Nan;
Zhang, Wenda;
Zhang, Xiaoli;
Zhou, Yupeng;
Zorzi, Nicola
Submitted: 2018-07-30
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project
of the Chinese Academy of Sciences (CAS) and China National Space
Administration (CNSA) currently performing an extended phase A study and
proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload
envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry
Focusing Array, Large Area Detector and Wide Field Monitor) offering
unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry
sensitivity. A large European consortium is contributing to the eXTP study and
it is expected to provide key hardware elements, including a Large Area
Detector (LAD). The LAD instrument for eXTP is based on the design originally
proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a
deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through
the technology of the large-area Silicon Drift Detectors - offering a spectral
resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators -
limiting the field of view to about 1 degree. In this paper we provide an
overview of the LAD instrument design, including new elements with respect to
the earlier LOFT configuration.
[4]
oai:arXiv.org:1807.09330 [pdf] - 1942050
The Wide Field Monitor onboard the eXTP mission
Hernanz, M.;
Brandt, S.;
Feroci, M.;
Orleanski, P.;
Santangelo, A.;
Schanne, S.;
Wu, Xin;
Zand, J. in't;
Zhang, S. N.;
Xu, Y. P.;
Bozzo, E.;
Evangelista, Y.;
Gálvez, J. L.;
Tenzer, C.;
Zwart, F.;
Lu, F. J.;
Zhang, S.;
Chen, T. X.;
Ambrosino, F.;
Argan, A.;
Del Monte, E.;
Budtz-Jørgensen, C.;
Lund, N.;
Olsen, P.;
Mansanet, C.;
Campana, R.;
Fuschino, F.;
Labanti, C.;
Rachevski, A.;
Vacchi, A.;
Zampa, G.;
Zampa, N.;
Rashevskaya, I.;
Bellutti, P.;
Borghi, G.;
Ficorella, F.;
Picciotto, A.;
Zorzi, N.;
Limousin, O.;
Meuris, A.
Submitted: 2018-07-24
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project
of the Chinese Academy of Sciences (CAS) and China National Space
Administration (CNSA) currently performing an extended phase A study and
proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload
envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry
Focusing Array, Large Area Detector and Wide Field Monitor) offering
unprecedented simultaneous wide-band X-ray timing and polarimetry sensitivity.
A large European consortium is contributing to the eXTP study and it is
expected to provide key hardware elements, including a Wide Field Monitor
(WFM). The WFM instrument for eXTP is based on the design originally proposed
for the LOFT mission within the ESA context. The eXTP/WFM envisages a wide
field X-ray monitor system in the 2-50 keV energy range, achieved through the
technology of the large-area Silicon Drift Detectors. The WFM will consist of 3
pairs of coded mask cameras with a total combined Field of View (FoV) of 90x180
degrees at zero response and a source localization accuracy of ~1 arcmin. In
this paper we provide an overview of the WFM instrument design, including new
elements with respect to the earlier LOFT configuration, and anticipated
performance.
[5]
oai:arXiv.org:1802.01674 [pdf] - 1630418
The X-Gamma Imaging Spectrometer (XGIS) onboard THESEUS
Campana, R.;
Fuschino, F.;
Labanti, C.;
Amati, L.;
Mereghetti, S.;
Fiorini, M.;
Frontera, F.;
Baldazzi, G.;
Bellutti, P.;
Borghi, G.;
Elmi, I.;
Evangelista, Y.;
Feroci, M.;
Ficorella, F.;
Orlandini, M.;
Picciotto, A.;
Marisaldi, M.;
Rachevski, A.;
Uslenghi, M.;
Vacchi, A.;
Zampa, G.;
Zampa, N.;
Zorzi, N.
Submitted: 2018-02-05
A compact and modular X and gamma-ray imaging spectrometer (XGIS) has been
designed as one of the instruments foreseen on-board the THESEUS mission
proposed in response to the ESA M5 call. The experiment envisages the use of
CsI scintillator bars read out at both ends by single-cell 25 mm 2 Silicon
Drift Detectors. Events absorbed in the Silicon layer (lower energy X rays) and
events absorbed in the scintillator crystal (higher energy X rays and
Gamma-rays) are discriminated using the on-board electronics. A coded mask
provides imaging capabilities at low energies, thus allowing a compact and
sensitive instrument in a wide energy band (~2 keV up to ~20 MeV). The
instrument design, expected performance and the characterization performed on a
series of laboratory prototypes are discussed.
[6]
oai:arXiv.org:1704.06122 [pdf] - 1565903
A compact and modular X and gamma-ray detector with a CsI scintillator
and double-readout Silicon Drift Detectors
Campana, R.;
Fuschino, F.;
Labanti, C.;
Marisaldi, M.;
Amati, L.;
Fiorini, M.;
Uslenghi, M.;
Baldazzi, G.;
Bellutti, P.;
Evangelista, Y.;
Elmi, I.;
Feroci, M.;
Ficorella, F.;
Frontera, F.;
Picciotto, A.;
Piemonte, C.;
Rachevski, A.;
Rashevskaya, I.;
Rignanese, L. P.;
Vacchi, A.;
Zampa, G.;
Zampa, N.;
Zorzi, N.
Submitted: 2017-04-20
A future compact and modular X and gamma-ray spectrometer (XGS) has been
designed and a series of prototypes have been developed and tested. The
experiment envisages the use of CsI scintillator bars read out at both ends by
single-cell 25 mm2 Silicon Drift Detectors. Digital algorithms are used to
discriminate between events absorbed in the Silicon layer (lower energy X rays)
and events absorbed in the scintillator crystal (higher energy X rays and
gamma-rays). The prototype characterization is shown and the modular design for
future experiments with possible astrophysical applications (e.g. for the
THESEUS mission proposed for the ESA M5 call) are discussed.
[7]
oai:arXiv.org:1407.1710 [pdf] - 1399568
Characterization of the VEGA ASIC coupled to large area
position-sensitive Silicon Drift Detectors
Campana, R.;
Evangelista, Y.;
Fuschino, F.;
Ahangarianabhari, M.;
Macera, D.;
Bertuccio, G.;
Grassi, M.;
Labanti, C.;
Marisaldi, M.;
Malcovati, P.;
Rachevski, A.;
Zampa, G.;
Zampa, N.;
Andreani, L.;
Baldazzi, G.;
Del Monte, E.;
Favre, Y.;
Feroci, M.;
Muleri, F.;
Rashevskaya, I.;
Vacchi, A.;
Ficorella, F.;
Giacomini, G.;
Picciotto, A.;
Zuffa, M.
Submitted: 2014-07-07
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly
useful for experiments in which a good energy resolution combined with a large
sensitive area is required, as in the case of X-ray astronomy space missions
and medical applications. This paper presents the experimental characterization
of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the
front-end electronics for XDXL-2, a large-area (30.5 cm^2) SDD prototype. The
ASICs were integrated on a specifically developed PCB hosting also the
detector. Results on the ASIC noise performances, both stand-alone and bonded
to the large area SDD, are presented and discussed.