Normalized to: Ferrer-Ribas, E.
[1]
oai:arXiv.org:1504.05865 [pdf] - 1579629
First detection of tracks of radon progeny recoils by MIMAC
Riffard, Q.;
Santos, D.;
Bosson, G.;
Bourrion, O.;
Descombes, T.;
Fourel, C.;
Guillaudin, O.;
Muraz, J. -F.;
Colas, P.;
Ferrer-Ribas, E.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Lebreton, L.;
Maire, D.
Submitted: 2015-04-22, last modified: 2017-06-20
The MIMAC experiment is a $\mu$-TPC matrix project for directional dark
matter search. Directional detection is a strategy based on the measurement of
the WIMP flux anisotropy due to the solar system motion with respect to the
dark matter halo. The main purpose of MIMAC project is the measurement of the
energy and the direction of nuclear recoils in 3D produced by elastic
scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the
Modane underground laboratory. In this paper, we report the first ionization
energy and 3D track observations of nuclear recoils produced by the radon
progeny. This measurement shows the capability of the MIMAC detector and opens
the possibility to explore the low energy recoil directionality signature.
[2]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[3]
oai:arXiv.org:1503.04561 [pdf] - 1376478
Search for chameleons with CAST
Anastassopoulos, V.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Christensen, F.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Desch, K.;
Dermenev, A.;
Eleftheriadis, C.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Hailey, C.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakobsen, A.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Kavuk, M.;
Krčmar, M.;
Krieger, C.;
Krüger, A.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Luzón, G.;
Neff, S.;
Ortega, I.;
Papaevangelou, T.;
Pivovarov, M. J.;
Raffelt, G.;
Riege, H.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Solanki, S. K.;
Vafeiadis, T.;
Villar, J. A.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.;
Brax, P.;
Lavrentyev, I.;
Upadhye, A.
Submitted: 2015-03-16, last modified: 2016-03-18
In this work we present a search for (solar) chameleons with the CERN Axion
Solar Telescope (CAST). This novel experimental technique, in the field of dark
energy research, exploits both the chameleon coupling to matter ($\beta_{\rm
m}$) and to photons ($\beta_{\gamma}$) via the Primakoff effect. By reducing
the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV
CAST became sensitive to the converted solar chameleon spectrum which peaks
around 600$\,$eV. Even though we have not observed any excess above background,
we can provide a 95% C.L. limit for the coupling strength of chameleons to
photons of $\beta_{\gamma}\!\lesssim\!10^{11}$ for $1<\beta_{\rm m}<10^6$.
[4]
oai:arXiv.org:1509.06190 [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a
slumped-glass telescope for axion research
Aznar, F.;
Castel, J.;
Christensen, F. E.;
Dafni, T.;
Decker, T. A.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Giomataris, I.;
Gracia, J. G.;
Hailey, C. J.;
Hill, R. M.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakobsen, A. C.;
Luzon, G.;
Mirallas, H.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Ruz, J.;
Vafeiadis, T.;
Vogel, J. K.
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray
detection line composed of a shielded Micromegas (micromesh gaseous structure)
detector of the microbulk technique. The detector is made from radiopure
materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m
focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of
thermally-formed (or "slumped") glass substrates deposited with multilayer
coatings. The system has been conceived as a technological pathfinder for the
future International Axion Observatory (IAXO), as it combines two of the
techniques (optic and detector) proposed in the conceptual design of the
project. It is innovative for two reasons: it is the first time an x-ray optic
has been designed and fabricated specifically for axion research, and the first
time a Micromegas detector has been operated with an x-ray optic. The line has
been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and
is currently looking for solar axions. The combination of the XRT and
Micromegas detector provides the best signal-to-noise ratio obtained so far by
any detection system of the CAST experiment with a background rate of
5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and
signal spot area.
[5]
oai:arXiv.org:1508.03006 [pdf] - 1330987
Exploring 0.1-10$\,$eV axions with a new helioscope concept
Galán, J.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Iguaz, F. J.;
Irastorza, I. G.;
García, J. A.;
Gracia, J.;
Luzón, G.;
Papaevangelou, T.;
Redondo, J.;
Tomás, A.
Submitted: 2015-08-12, last modified: 2015-09-07
We explore the possibility to develop a new axion helioscope type, sensitive
to the higher axion mass region favored by axion models. We propose to use a
low background large volume TPC immersed in an intense magnetic field. Contrary
to traditional tracking helioscopes, this detection technique takes advantage
of the capability to directly detect the photons converted on the buffer gas
which defines the axion mass sensitivity region, and does not require pointing
the magnet to the Sun. The operation flexibility of a TPC to be used with
different gas mixtures (He, Ne, Xe, etc) and pressures (from 10 mbar to 10 bar)
will allow to enhance sensitivity for axion masses from few meV to several eV.
We present different helioscope data taking scenarios, considering detection
efficiency and axion absorption probability, and show the sensitivities
reachable with this technique to be few $\times$ 10$^{-11}\,$GeV$^{-1}$ for a
5$\,$T$\,$m$^3$ scale TPC. We show that a few years program taking data with
such setup would allow to probe the KSVZ axion model for axion masses above 100
meV.
[6]
oai:arXiv.org:1501.01466 [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas
x-ray detectors for axion searches
Iguaz, F. J.;
Aune, S.;
Aznar, F.;
Castel, J. F.;
Dafni, T.;
Davenport, M.;
Ferrer-Ribas, E.;
Galan, J.;
Garcia, J. A.;
Garza, J. G.;
Giomataris, I.;
Irastorza, I. G.;
Papaevangelou, T.;
Rodriguez, A.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in
the presence of high magnetic fields. The use of low background x-ray detectors
is an essential component contributing to the sensitivity of these searches. In
this work, we review the recent advances on Micromegas detectors used in the
CERN Axion Solar Telescope (CAST) and proposed for the future International
Axion Observatory (IAXO). The actual setup in CAST has achieved background
levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than
the first generation of Micromegas detectors. This reduction is based on active
and passive shielding techniques, the selection of radiopure materials, offline
discrimination techniques and the high granularity of the readout. We describe
in detail the background model of the detector, based on its operation at CAST
site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4
simulations. The best levels currently achieved at LSC are low than 10$^{-7}$
keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of
this technology in IAXO. Finally, we present some ideas and results for
reducing the energy threshold of these detectors below 1 keV, using
high-transparent windows, autotrigger electronics and studying the cluster
shape at different energies. As a high flux of axion-like-particles is expected
in this energy range, a sub-keV threshold detector could enlarge the physics
case of axion helioscopes.
[7]
oai:arXiv.org:1307.1985 [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark
matter gap
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Brauninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Da Riva, E.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Georgiopoulou, E.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Marzoa, M. Gomez;
Gruber, E.;
Guthorl, T.;
Hartmann, R.;
Hauf, S.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Karuza, M.;
Konigsmann, K.;
Kotthaus, R.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Lang, P. M.;
Laurent, J. M.;
Liolios, A.;
Ljubicic, A.;
Lozza, V.;
Luzon, G.;
Neff, S.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Riege, H.;
Rodriguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Shilon, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomas, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar
axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV.
This closes the gap to the cosmological hot dark matter limit and actually
overlaps with it. From the absence of excess X-rays when the magnet was
pointing to the Sun we set a typical upper limit on the axion-photon coupling
of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on
the pressure setting. Future direct solar axion searches will focus on
increasing the sensitivity to smaller values of g_a, for example by the
currently discussed next generation helioscope IAXO.
[8]
oai:arXiv.org:1210.3287 [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine
mixtures
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Gonzalez-Diaz, D.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Rodríguez, A.;
Segui, L.;
Tomás, A.
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high
pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains
and energy resolutions for 22.1 keV X-rays are measured for pressures between 1
and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We
observe stable operation at all pressures, and a strongly enhanced gas gain,
suggestive of Penning-like energy-transfer processes. The effect is present at
all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3
%. Operating in this concentration range, the maximum gain reached values as
high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable
for 22.1 keV X-rays is substantially better than the one previously obtained in
pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of
interest for calorimetric applications of high pressure gas Xe TPCs, in
particular for the search of the neutrinoless double beta decay of Xe-136. The
resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value
of Xe-136 for 1 (10) bar.
[9]
oai:arXiv.org:1209.6347 [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST
experiment
Ferrer-Ribas, E.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Ezer, C.;
Fanourakis, G.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gómez, H.;
Gruber, E.;
Guthörl, T.;
Hartmann, R.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovčić, K.;
Karuza, M.;
Königsmann, K.;
Kotthaus, R.;
Krčmar, M.;
Kuster, M.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Lozza, V.;
Lutz, G.;
Luzón, G.;
Morales, J.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Rashba, T.;
Riege, H.;
Rodríguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomás, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope
(CAST) will be presented. Recent results obtained by the use of $^3$He as a
buffer gas has allowed us to extend our sensitivity to higher axion masses than
our previous measurements with $^4$He. With about 1 h of data taking at each of
252 different pressure settings we have scanned the axion mass range 0.39 eV$
\le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the
magnet was pointing to the Sun we set a typical upper limit on the axion-photon
coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the
exact value depending on the pressure setting. CAST published results represent
the best experimental limit on the photon couplings to axions and other similar
exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the
considered mass range and for the first time the limit enters the region
favored by QCD axion models. Preliminary sensitivities for axion masses up to
1.16 eV will also be shown reaching mean upper limits on the axion-photon
coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L.
Expected sensibilities for the extension of the CAST program up to 2014 will be
presented. Moreover long term options for a new helioscope experiment will be
evoked.
[10]
oai:arXiv.org:1208.5690 [pdf] - 771411
CAST microbulk micromegas in the Canfranc Underground Laboratory
Tomás, A.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gómez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Papaevangelou, T.;
Rodríguez, A.;
Ruz, J.;
Seguí, L.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2012-08-28
During the last taking data campaigns of the CAST experiment, the micromegas
detectors have achieved background levels of $\approx 5 \times
10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has
been possible thanks to the introduction of the microbulk technology, the
implementation of a shielding and the development of discrimination algorithms.
It has motivated new studies towards a deeper understanding of CAST detectors
background. One of the working lines includes the construction of a replica of
the set-up used in CAST by micromegas detectors and its installation in the
Canfranc Underground Laboratory. Thanks to the comparison between the
performance of the detectors underground and at surface, shielding upgrades,
etc, different contributions to the detectors background have been evaluated.
In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$
for the intrinsic background of the detector has been obtained. This work means
a first evaluation of the potential of the newest micromegas technology in an
underground laboratory, the most suitable environment for Rare Event Searches.
[11]
oai:arXiv.org:1201.3012 [pdf] - 1092971
Characterization of microbulk detectors in argon- and neon-based
mixtures
Submitted: 2012-01-14
A recent Micromegas manufacturing technique, so called Microbulk, has been
developed, improving the uniformity and stability of this kind of detectors.
Excellent energy resolutions have been obtained, reaching values as low as 11%
FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its
flexible structure, low material budget and high radio-purity. Two microbulk
detectors with gaps of 50 and 25 um have been characterized in argon- and
neon-based mixtures with ethane, isobutane and cyclohexane. The results will be
presented and discussed. The gain curves have been fitted to the Rose-Korff
gain model and dependences of the electron mean free path and the threshold
energy for ionization have been obtained. The possible relation between these
two parameters and the energy resolution will be also discussed.
[12]
oai:arXiv.org:1110.2608 [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Galan, J.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gomez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Papaevangelou, T.;
Rodriguez, A.;
Ruz, J.;
Segui, L.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination
capabilities, are good candidates for rare event search experiments. Recent
X-ray background levels achieved by these detectors in the CAST experiment have
motivated further studies in the nature of the background levels measured. In
particular, different shielding configurations have been tested at the Canfranc
Underground Laboratory, using a microbulk type detector which was previously
running at the CAST experiment. The first results underground show that this
technology, which is made of low radiative materials, is able to reach
background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a
proper shielding. Moreover, the experimental background measurements are
complemented with Geant4 simulations which allow to understand the origin of
the background, and to optimize future shielding set-ups.
[13]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
Attié, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[14]
oai:arXiv.org:1009.1827 [pdf] - 261761
Micromegas readouts for double beta decay searches
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Giomataris, I.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Rodríguez, A.;
Seguí, L.;
Tomás, A.
Submitted: 2010-09-09
Double beta $\beta\beta$ decay experiments are one of the most active
research topics in Neutrino Physics. The measurement of the neutrinoless mode
$0\nu\beta\beta$ could give unique information on the neutrino mass scale and
nature. The current generation of experiments aims at detector target masses at
the 100 kg scale, while the next generation will need to go to the ton scale in
order to completely explore the inverse hierarchy models of neutrino mass. Very
good energy resolutions and ultra-low background levels are the two main
experimental requirements for a successful experiment. The topological
information of the $\beta\beta$ events offered by gaseous detectors like gas
Time Projection Chambers (TPC) could provide a very powerful tool of signal
identification and background rejection. However only recent advances in TPC
readouts may assure the competitiveness of a high pressure gas TPCs for
$\beta\beta$ searches, especially regarding the required energy resolution. In
this paper we present first results on energy resolution with state-of-the-art
microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV
alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have
been achieved for pressures up to 5 bar. These results, together with their
recently measured radiopurity , prove that Micromegas readouts are not only a
viable option but a very competitive one for $\beta\beta$ searches.