Normalized to: Ferreira, D.
[1]
oai:arXiv.org:1807.10777 [pdf] - 1729194
Small-N collisional dynamics IV: Order in the realm of not-so-small-N
Submitted: 2018-07-27
In this paper, the fourth in the series, we continue our study of
combinatorics in chaotic Newtonian dynamics. We focus once again on the chaotic
four-body problem in Newtonian gravity assuming finite-sized particles, and
interactions that produce direct collisions between any two particles. Our
long-term goal is to predict the probability of a given collision event
occurring over the course of an interaction, as a function of the numbers and
properties of the particles. In previous papers, we varied the number of
interacting particles, as well as the distributions of particle radii and
masses. Here, we refine the methods developed in these preceding studies, and
arrive at a final and robust methodology that can be used to study collisional
dynamics in a variety of astrophysical contexts, ranging from stars in star
clusters, galaxies in galaxy groups and clusters and even the collisional
growth of planetesimals in protoplanetary disks. We further present and refine
the concept of a Collision Rate Diagram (CRD), the primary tool we use to
quantify the relative rates for different collision scenarios to occur. The
agreement between our final theoretical model and the results of numerical
scattering simulations is excellent.
[2]
oai:arXiv.org:1608.01075 [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview,
recent progress, and future perspectives
Tamura, Naoyuki;
Takato, Naruhisa;
Shimono, Atsushi;
Moritani, Yuki;
Yabe, Kiyoto;
Ishizuka, Yuki;
Ueda, Akitoshi;
Kamata, Yukiko;
Aghazarian, Hrand;
Arnouts, Stephane;
Barban, Gabriel;
Barkhouser, Robert H.;
Borges, Renato C.;
Braun, David F.;
Carr, Michael A.;
Chabaud, Pierre-Yves;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chiba, Masashi;
Chou, Richard C. Y.;
Chu, You-Hua;
Cohen, Judith G.;
de Almeida, Rodrigo P.;
de Oliveira, Antonio C.;
de Oliveira, Ligia S.;
Dekany, Richard G.;
Dohlen, Kjetil;
Santos, Jesulino B. dos;
Santos, Leandro H. dos;
Ellis, Richard S.;
Fabricius, Maximilian;
Ferrand, Didier;
Ferreira, Decio;
Golebiowski, Mirek;
Greene, Jenny E.;
Gross, Johannes;
Gunn, James E.;
Hammond, Randolph;
Harding, Albert;
Hart, Murdock;
Heckman, Timothy M.;
Hirata, Christopher M.;
Ho, Paul;
Hope, Stephen C.;
Hovland, Larry;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Ping-Jie;
Jaquet, Marc;
Jing, Yipeng;
Karr, Jennifer;
Kimura, Masahiko;
King, Matthew E.;
Komatsu, Eiichiro;
Brun, Vincent Le;
Fevre, Olivier Le;
Fur, Arnaud Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig P.;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas S.;
de Oliveira, Claudia Mendes;
Minowa, Yosuke;
Morantz, Chaz N.;
Murayama, Hitoshi;
Murray, Graham J.;
Ohyama, Youichi;
Orndorff, Joseph;
Pascal, Sandrine;
Pereira, Jefferson M.;
Reiley, Daniel J.;
Reinecke, Martin;
Ritter, Andreas;
Roberts, Mitsuko;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Sodre, Laerte;
Spergel, David N.;
Steinkraus, Aaron J.;
Strauss, Michael A.;
Surace, Christian;
Suto, Yasushi;
Suzuki, Nao;
Swinbank, John;
Tait, Philip J.;
Takada, Masahiro;
Tamura, Tomonori;
Tanaka, Yoko;
Tresse, Laurence;
Verducci, Orlando;
Vibert, Didier;
Vidal, Clement;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Yan, Chi-Hung;
Yasuda, Naoki
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the
8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed,
optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394
reconfigurable fibers will be distributed over the 1.3 deg field of view. The
spectrograph has been designed with 3 arms of blue, red, and near-infrared
cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure
at a resolution of ~1.6-2.7A. An international collaboration is developing this
instrument under the initiative of Kavli IPMU. The project is now going into
the construction phase aiming at undertaking system integration in 2017-2018
and subsequently carrying out engineering operations in 2018-2019. This article
gives an overview of the instrument, current project status and future paths
forward.
[3]
oai:arXiv.org:1608.00675 [pdf] - 1531167
The Current Status of Prime Focus Instrument of Subaru Prime Focus
Spectrograph
Wang, Shiang-Yu;
Schwochert, Mark A.;
Huang, Pin-Jie;
Chen, Hsin-Yo;
Kimura, Masahiko;
Chou, Richard C. Y.;
Chang, Yin-Chang;
Hu, Yen-Sang;
Ling, Hung-Hsu;
Morantz, Chaz N.;
Reiley, Dan J.;
Mao, Peter;
Braun, David F.;
Wen, Chih-Yi;
Yan, Chi-Hung;
Karr, Jennifer;
Gunn, James E.;
Murray, Graham;
Tamura, Naoyuki;
Takato, Naruhisa;
Shimono, Atsushi;
Ferreira, Decio;
Santosh, Leandro Henriqu dos;
Oliveira, Ligia Souza;
de Oliveira, Antonio Cesar;
Marrara, Lucas Souza
Submitted: 2016-08-01
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber
spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will
cover 1.3 degree diameter field with 2394 fibers to complement the imaging
capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime
Focus Instrument (PFI) provides the interface with the top structure of Subaru
telescope and also accommodates the optical bench in which Cobra fiber
positioners are located. In addition, the acquisition and guiding cameras
(AGCs), the optical fiber positioner system, the cable wrapper, the fiducial
fibers, illuminator, and viewer, the field element, and the telemetry system
are located inside the PFI. The mechanical structure of the PFI was designed
with special care such that its deflections sufficiently match those of the
HSC's Wide Field Corrector (WFC) so the fibers will stay on targets over the
course of the observations within the required accuracy. In this report, the
latest status of PFI development will be given including the performance of PFI
components, the setup and performance of the integration and testing equipment.
[4]
oai:arXiv.org:1507.00725 [pdf] - 1241387
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed
optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2015-07-02
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber
spectrograph with 2394 science fibers distributed across a 1.3-deg diameter
field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from
0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously
strengthens its ability to target three main survey programs: cosmology,
galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a
resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available
by simply exchanging dispersers. We highlight some of the technological aspects
of the design. To transform the telescope focal ratio, a broad-band coated
microlens is glued to each fiber tip. A higher transmission fiber is selected
for the longest part of the cable system, optimizing overall throughput; a
fiber with low focal ratio degradation is selected for the fiber-positioner and
fiber-slit components, minimizing the effects of fiber movements and fiber
bending. Fiber positioning will be performed by a positioner consisting of two
stages of piezo-electric rotary motors. The positions of these motors are
measured by taking an image of artificially back-illuminated fibers with the
metrology camera located in the Cassegrain container; the fibers are placed in
the proper location by iteratively measuring and then adjusting the positions
of the motors. Target light reaches one of the four identical fast-Schmidt
spectrograph modules, each with three arms. The PFS project has passed several
project-wide design reviews and is now in the construction phase.
[5]
oai:arXiv.org:1411.1573 [pdf] - 1223044
A NuSTAR observation of the center of the Coma Cluster
Gastaldello, F.;
Wik, D. R.;
Molendi, S.;
Westergaard, N. J.;
Hornstrup, A.;
Madejski, G.;
Ferreira, D. D. M.;
Boggs, S. E.;
Christensen, F. E.;
Craig, W. W.;
Grefenstette, B. W.;
Hailey, C. J.;
Harrison, F. A.;
Madsen, K. K.;
Stern, D.;
Zhang, W. W.
Submitted: 2014-11-06, last modified: 2015-01-12
We present the results of a 55ks NuSTAR observation of the core of the Coma
Cluster. The global spectrum can be explained by thermal gas emission, with a
conservative 90% upper limit to non-thermal inverse Compton (IC) emission of
$5.1 \times 10^{-12}$ erg cm$^{-2}$ s$^{-1}$ in a 12 arcmin $\times$ 12 arcmin
field of view . The brightness of the thermal component in this central region
does not allow more stringent upper limits on the IC component when compared
with non-imaging instruments with much larger fields of view where claims of
detections have been made. Future mosaic NuSTAR observations of Coma will
further address this issue. The temperature map shows a relatively uniform
temperature distribution with a gradient from the hot northwest side to the
cooler southeast, in agreement with previous measurements. The temperature
determination is robust given the flat effective area and low background in the
3-20 keV band, making NuSTAR an ideal instrument to measure high temperatures
in the intracluster medium.
[6]
oai:arXiv.org:1408.2849 [pdf] - 863453
Multi-fibers connectors systems for FOCCoS-PFS-Subaru
de Oliveira, Antonio Cesar;
de Oliveira, Ligia Souza;
Marrara, Lucas Souza;
Santos, Leandro Henrique dos;
de Arruda, Marcio Vital;
Santos, Jesulino Bispo dos;
Ferreira, Décio;
Rosa, Josimar Aparecido;
Vilaca, Rodrigo de Paiva;
de Oliveira, Laerte Sodre Junior Claudia Mendes;
Gunn, James E.
Submitted: 2014-08-12
The Fiber Optical Cable and Connector System (FOCCoS), provides optical
connection between 2400 positioners and a set of spectrographs through optical
fibers cables as part of PFS instrument for Subaru telescope. The optical fiber
cable will be segmented in 3 parts along the route, cable A, cable B and cable
C, connected by a set of multi-fiber connectors. The company USCONEC produces
the multi-fiber connector under study. The USCONEC 32F model can connect 32
optical fibers in a 4 x 8 matrix arrangement. The ferrules are made of a
durable composite, Polyphenylene Sulfide (PPS) based thermoplastic. The
connections are held in place by a push-on/pull-off latch, and the connector
can also be distinguished by a pair of metal guide pins that protrude from the
front of the connector. Two fibers per connector will be used for monitoring
the connection procedure. It was found to be easy to polish and it is small
enough to be mounted in groups. Highly multiplexed instruments like PFS require
a fiber connector system that can deliver excellent optical performance and
reliability. PFS requires two different types of structures to organize the
connectors. The Tower Connector system, with 80 multi-fiber connectors, will be
a group of connectors for connecting cable B (Telescope Structure) with cable C
(Positioners Plate). The Gang Connector system is a group of 8 gang connectors,
each one with 12 multi-fibers connectors, for connecting cable B (Telescope
Structure) with cable A (Spectrograph). The bench tests with these connector
systems and the chosen fibers should measure the throughput of light and the
stability after many connections and disconnections. In this paper we describe
tests and procedures to evaluate the throughput and FRD increment. The lifetime
of the ferrules is also in evaluation.
[7]
oai:arXiv.org:1408.2848 [pdf] - 863452
Slit device for FOCCoS, PFS, Subaru
de Oliveira, Antonio Cesar;
Gunn, James E.;
de Oliveira, Ligia Souza;
de Arruda, Marcio Vital;
Marrara, Lucas Souza;
Santos, Leandro Henrique dos;
Ferreira, Décio;
Santos, Jesulino Bispo dos;
Rosa, Josimar Aparecido;
Ribeiro, Flavio Felipe;
Vilaça, Rodrigo de Paiva;
Junior, Orlando Verducci;
Junior, Laerte Sodré;
de Oliveira, Claudia Mendes
Submitted: 2014-08-12
The Fiber Optical Cable and Connector System, FOCCoS, subsystem of the Prime
Focus Spectrograph, PFS, for Subaru telescope, is responsible to feed four
spectrographs with a set of optical fibers cables. The light injection for each
spectrograph is assured by a convex curved slit with a linear array of 616
optical fibers. In this paper we present a design of a slit that ensures the
right direction of the fibers by using masks of micro holes. This kind of mask
is made by a technique called electroforming, which is able to produce a nickel
plate with holes in a linear sequence. The precision error is around 1micron in
the diameter and 1 micron in the positions of the holes. This nickel plate may
be produced with a thickness between 50 and 200 microns, so it may be very
flexible. This flexibility allows the mask to be bent into the shape necessary
for a curved slit. The concept requires two masks, which we call Front Mask,
and Rear Mask, separated by a gap that defines the thickness of the slit. The
pitch and the diameter of the holes define the linear geometry of the slit; the
curvature of each mask defines the angular geometry of the slit. Obviously,
this assembly must be mounted inside a structure rigid and strong enough to be
supported inside the spectrograph. This structure must have a CTE optimized to
avoid displacement of the fibers or increased FRD of the fibers when the device
is submitted to temperatures around 3 degrees Celsius, the temperature of
operation of the spectrograph. We have produced two models. Both are mounted
inside a very compact Invar case, and both have their front surfaces covered by
a dark composite, to reduce stray light. Furthermore, we have conducted
experiments with two different internal structures to minimize effects caused
by temperature gradients.
[8]
oai:arXiv.org:1408.2853 [pdf] - 863454
Polish device for FOCCoS/PFS slit system
de Oliveira, Antonio Cesar;
de Oliveira, Ligia Souza;
de Arruda, Marcio Vital;
Marrara, Lucas Souza;
Santos, Leandro Henrique dos;
Ferreira, Décio;
Santos, Jesulino Bispo dos;
Vilaca, Rodrigo de Paiva;
Rosa, Josimar Aparecido;
Junior, Laerte Sodre;
de Oliveira, Claudia Mendes
Submitted: 2014-08-12
The Fiber Optical Cable and Connector System, FOCCoS, for the Prime Focus
Spectrograph, PFS, is responsible for transporting light from the Subaru
Telescope focal plane to a set of four spectrographs. Each spectrograph will be
fed by a convex curved slit with 616 optical fibers organized in a linear
arrangement. The slit frontal surface is covered with a special dark composite,
made with refractory oxide, which is able to sustain its properties with
minimum quantities of abrasives during the polishing process; this stability is
obtained This stability is obtained by the detachment of the refractory oxide
nanoparticles, which then gently reinforce gently the polishing process and
increase its the efficiency. The surface roughness measured in several samples
after high performance polishing was about 0.01 microns. Furthermore, the time
for obtaining a polished surface with this quality is about 10 times less than
the time required for polishing a brass, glass or ceramic surface of the same
size. In this paper, we describe the procedure developed for high quality
polishing of this type of slit. The cylindrical polishing described here, uses
cylindrical concave metal bases on which glass paper is based. The polishing
process consists to use grid sequences of 30 microns, 12 microns, 9 microns, 5
microns, 3 microns, 1 micron and, finally, a colloidal silica on a chemical
cloth. To obtain the maximum throughput, the surface of the fibers should be
polished in such a way that they are optically flat and free from scratches.
The optical fibers are inspected with a microscope at all stages of the
polishing process to ensure high quality. The efficiency of the process may be
improved by using a cylindrical concave composite base as a substrate suitable
for diamond liquid solutions. Despite this process being completely by hand,
the final result shows a very high quality.
[9]
oai:arXiv.org:1408.2825 [pdf] - 1216260
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a
massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsuc, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber
spectrograph with 2394 science fibers, which are distributed in 1.3 degree
diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide
wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000,
strengthens its ability to target three main survey programs: cosmology,
Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with
resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply
exchanging dispersers. PFS takes the role for the spectroscopic part of the
Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam
works on the imaging part. To transform the telescope plus WFC focal ratio, a
3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip.
A higher transmission fiber is selected for the longest part of cable system,
while one with a better FRD performance is selected for the fiber-positioner
and fiber-slit components, given the more frequent fiber movements and tightly
curved structure. Each Fiber positioner consists of two stages of
piezo-electric rotary motors. Its engineering model has been produced and
tested. Fiber positioning will be performed iteratively by taking an image of
artificially back-illuminated fibers with the Metrology camera located in the
Cassegrain container. The camera is carefully designed so that fiber position
measurements are unaffected by small amounts of high special-frequency
inaccuracies in WFC lens surface shapes. Target light carried through the fiber
system reaches one of four identical fast-Schmidt spectrograph modules, each
with three arms. Prototype VPH gratings have been optically tested. CCD
production is complete, with standard fully-depleted CCDs for red arms and
more-challenging thinner fully-depleted CCDs with blue-optimized coating for
blue arms.
[10]
oai:arXiv.org:1408.2847 [pdf] - 863451
Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru
de Oliveira, Antonio Cesar;
de Oliveira, Lígia Souza;
de Arruda, Márcio V.;
Marrara, Lucas Souza;
Santos, Leandro H. dos;
Ferreira, Décio;
Santos, Jesulino B. dos;
Rosa, Josimar A.;
Junior, Orlando V.;
Pereira, Jeferson M.;
Castilho, Bruno;
Gneiding, Clemens;
Junior, Laerte S.;
de Oliveira, Claudia M.;
Gunn, James E.;
Ueda, Akitoshi;
Takato, Naruhisa;
Shimono, Atsushi;
Sugai, Hajime;
Karoji, Hiroshi;
Kimura, Masahiko;
Tamura, Naoyuki;
Wang, Shiang-Yu;
Murray, Graham;
Mignant, David Le;
Madec, Fabrice;
Jaquet, Marc;
Vives, Sebastien;
Fisher, Charlie;
Braun, David;
Schwochert, Mark;
Reiley, Daniel J.
Submitted: 2014-08-12
FOCCoS, Fiber Optical Cable and Connector System, has the main function of
capturing the direct light from the focal plane of Subaru Telescope using
optical fibers, each one with a microlens in its tip, and conducting this light
through a route containing connectors to a set of four spectrographs. The
optical fiber cable is divided in 3 different segments called Cable A, Cable B
and Cable C. Multi-fibers connectors assure precise connection among all
optical fibers of the segments, providing flexibility for instrument changes.
To assure strong and accurate connection, these sets are arranged inside two
types of assemblies: the Tower Connector, for connection between Cable C and
Cable B; and the Gang Connector, for connection between Cable B and Cable A.
Throughput tests were made to evaluate the efficiency of the connections. A
lifetime test connection is in progress. Cable C is installed inside the PFI,
Prime Focus Instrument, where each fiber tip with a microlens is bonded to the
end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this
assembly allows each fiber to be placed anywhere within its patrol region,
which is 9.5mm diameter.. Each positioner uses a fiber arm to support the
ferrule, the microlens, and the optical fiber. 2400 of these assemblies are
arranged on a motor bench plate in a hexagonal-closed-packed disposition.
[11]
oai:arXiv.org:1403.2722 [pdf] - 1208318
NuSTAR Observations of the Bullet Cluster: Constraints on Inverse
Compton Emission
Wik, Daniel R.;
Hornstrup, Allan;
Molendi, Silvano;
Madejski, Grzegorz;
Harrison, Fiona A.;
Zoglauer, Andreas;
Grefenstette, Brian W.;
Gastaldello, Fabio;
Madsen, Kristin K.;
Westergaard, Niels J.;
Ferreira, Desiree D. M.;
Kitaguchi, Takao;
Pedersen, Kristian;
Boggs, Steven E.;
Christensen, Finn E.;
Craig, William W.;
Hailey, Charles J.;
Stern, Daniel;
Zhang, William W.
Submitted: 2014-03-11
The search for diffuse non-thermal inverse Compton (IC) emission from galaxy
clusters at hard X-ray energies has been undertaken with many instruments, with
most detections being either of low significance or controversial. Background
and contamination uncertainties present in the data of non-focusing
observatories result in lower sensitivity to IC emission and a greater chance
of false detection. We present 266ks NuSTAR observations of the Bullet cluster,
detected from 3-30 keV. NuSTAR's unprecedented hard X-ray focusing capability
largely eliminates confusion between diffuse IC and point sources; however, at
the highest energies the background still dominates and must be well
understood. To this end, we have developed a complete background model
constructed of physically inspired components constrained by extragalactic
survey field observations, the specific parameters of which are derived locally
from data in non-source regions of target observations. Applying the background
model to the Bullet cluster data, we find that the spectrum is well - but not
perfectly - described as an isothermal plasma with kT=14.2+/-0.2 keV. To
slightly improve the fit, a second temperature component is added, which
appears to account for lower temperature emission from the cool core, pushing
the primary component to kT~15.3 keV. We see no convincing need to invoke an IC
component to describe the spectrum of the Bullet cluster, and instead argue
that it is dominated at all energies by emission from purely thermal gas. The
conservatively derived 90% upper limit on the IC flux of 1.1e-12 erg/s/cm^2
(50-100 keV), implying a lower limit on B>0.2{\mu}G, is barely consistent with
detected fluxes previously reported. In addition to discussing the possible
origin of this discrepancy, we remark on the potential implications of this
analysis for the prospects for detecting IC in galaxy clusters in the future.
[12]
oai:arXiv.org:1106.3183 [pdf] - 389895
A Ly{\alpha} blob and zabs {\approx} zem damped Ly{\alpha} absorber in
the dark matter halo of the binary quasar Q 0151+048
Zafar, Tayyaba;
Møller, Palle;
Ledoux, Cédric;
Fynbo, Johan P. U.;
Nilsson, Kim K.;
Christensen, Lise;
D'Odorico, Sandro;
Milvang-Jensen, Bo;
Michałowski, Michał J.;
Ferreira, Desiree D. M.
Submitted: 2011-06-16
Q0151+048 is a physical QSO pair at z ~ 1.929 with a separation of 3.3 arcsec
on the sky. In the spectrum of Q0151+048A (qA), a DLA is observed at a higher
redshift. We have previously detected the host galaxies of both QSOs, as well
as a Lya blob. We performed low-resolution spectroscopy with the slit aligned
with the extended emission. We also observed the system using the
medium-resolution VLT/X-shooter spectrograph and the slit aligned with the two
QSOs. We measure systemic redshifts of zem(A)=1.92924{\pm}0.00036 and
zem(B)=1.92863{\pm}0.00042 from the H{\beta} and H{\alpha} emission lines,
respectively. We estimate the masses of the black holes of the two QSOs to be
10^9.33 M{\odot} and 10^8.38 M{\odot} for qA and qB, respectively. From this we
infered the mass of the dark matter halos hosting the two QSOs: 10^13.74
M{\odot} and 10^13.13 M{\odot} for qA and qB, respectively. We observe a
velocity gradient along the major axis of the Lya blob consistent with the
rotation curve of a large disk galaxy, but it may also be caused by gas inflow
or outflow. We detect residual continuum in the DLA trough which we interpret
as emission from the host galaxy of qA. The derived H0 column density of the
DLA is log NH0 = 20.34 {\pm} 0.02. Metal column densities results in an overall
metallicity of 0.01 Z{\odot}. We detect CII* which allows us to make a physical
model of the DLA cloud. From the systemic redshifts of the QSOs, we conclude
that the Lya blob is associated with qA rather than with the DLA. The DLA must
be located in front of both the Lya blob and qA at a distance larger than 30
kpc. The two QSOs accrete at normal eddington ratios. The DM halo of this
double quasar will grow to the mass of our local super-cluster at z=0. We point
out that those objects therefore form an ideal laboratory to study the physical
interactions in a z=2 pre-cursor of our local super-cluster.
[13]
oai:arXiv.org:0811.2793 [pdf] - 315332
Resolving the discrepancy between lensing and X-ray mass estimates of
the complex galaxy cluster Abell 1689
Submitted: 2008-11-18
There is a long-standing discrepancy between galaxy cluster masses determined
from X-ray and gravitational lensing observations of which Abell 1689 is a
well-studied example. In this work we take advantage of 180 ks of Chandra X-ray
observations and a new weak gravitational study based on a Hubble Space
Telescope mosaic covering the central 1.8 Mpc x 1.4 Mpc to eliminate the mass
discrepancy. In contrast to earlier X-ray analyses where the very circular
surface brightness has been inferred as Abell 1689 being spherically symmetric
and in hydrostatic equilibrium, a hardness ratio map analysis reveals a regular
and symmetric appearing main clump with a cool core plus some substructure in
the North Eastern part of the cluster. The gravitational lensing mass model
supports the interpretation of Abell 1689 being composed of a main clump, which
is possibly a virialized cluster, plus some substructure. In order to avoid
complications and mis-interpretations due to X-ray emission from the
substructure, we exclude it from the mass reconstruction. Comparing X-ray and
lensing mass profiles of the regular main part only, shows no significant
discrepancy between the two methods and the obtained mass profiles are
consistent over the full range where the mass can be reconstructed from X-rays
(out to approx. 1 Mpc). The obtained cluster mass within approx. 875 kpc
derived from X-rays alone is 6.4 plus/minus 2.1 x 10^14 solar masses compared
to a weak lensing mass of 8.6 plus/minus 3.0 x 10^14 solar masses within the
same radius.
[14]
oai:arXiv.org:astro-ph/0703407 [pdf] - 90216
Spatially resolved properties of the GRB 060505 host: implications for
the nature of the progenitor
Thoene, Christina C.;
Fynbo, Johan P. U.;
Oestlin, Goeran;
Milvang-Jensen, Bo;
Wiersema, Klaas;
Malesani, Daniele;
Ferreira, Desiree Della Monica;
Gorosabel, Javier;
Kann, D. Alexander;
Watson, Darach;
Michalowski, Michal J.;
Fruchter, Andrew S.;
Levan, Andrew J.;
Hjorth, Jens;
Sollerman, Jesper
Submitted: 2007-03-15, last modified: 2007-12-06
GRB 060505 was the first well-observed nearby possible long-duration GRB that
had no associated supernova. Here we present spatially resolved spectra of the
host galaxy of GRB 060505, an Sbc spiral, at redshift z=0.0889. The GRB
occurred inside a star-forming region in the northern spiral arm at 6.5 kpc
from the center. From the position of the emission lines, we determine a
maximum rotational velocity for the galaxy of v~212km/s corresponding to a mass
of 1.14x10^11 M_solar within 11 kpc from the center. By fitting single-age
spectral synthesis models to the stellar continuum, we derive a very young age
for the GRB site, confirmed by photometric and Halpha line measurements, of
around 6 Myr which corresponds to the lifetime of a 32 M_solar star. The
metallicity derived from several emission line measurements is lowest at the
GRB site with 1/5 Z_solar but roughly solar in the rest of the galaxy. Using
the 2dF galaxy redshift survey we can locate the host galaxy in its large scale
(Mpc) environment. The galaxy lies in the foreground of a filamentary
overdensity extending south west from the galaxy cluster Abell 3837 at
z=0.0896. The properties of the GRB site are similar to those found for other
long-duration GRB host galaxies with high specific star formation rate and low
metallicity, which is an indication that GRB 060505 originated from a young
massive star that died without making a supernova.