sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Ferrari, M.

Normalized to: Ferrari, M.

28 article(s) in total. 266 co-authors, from 1 to 18 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:2006.13956  [pdf] - 2122111
CASTLE: performances and science cases
Comments: 29 pages, 11 figures
Submitted: 2020-06-24
We present here the Calar Alto Schmidt-Lemaitre Telescope (CASTLE) concept, a technology demonstrator for curved detectors, that will be installed at the Calar Alto Observatory (Spain). This telescope has a wide field of view (2.36x1.56 deg^2) and a design, optimised to generate a Point Spread Function with very low level wings and reduced ghost features, which makes it considerably less susceptible to several systematic effects usually affecting similar systems. These characteristics are particularly suited to study the low surface brightness Universe. CASTLE will be able to reach surface brightness orders of magnitude fainter than the sky background level and observe the extremely extended and faint features around galaxies such as tidal features, stellar halos, intra-cluster light, etc. CASTLE will also be used to search and detect astrophysical transients such as gamma ray bursts (GRB), gravitational wave optical counterparts, neutrino counterparts, etc. This will increase the number of precisely localized GRBs from 20% to 60% (in the case of Fermi/GMB GRBs).
[2]  oai:arXiv.org:2004.09361  [pdf] - 2080264
Stress mirror polishing for future large lightweight mirrors: design using shape optimization
Comments: 18 pages, 17 figures
Submitted: 2020-04-20
This study proposes a new way to manufacture large lightweight aspherics for space telescopes using Stress Mirror Polishing (SMP). This technique is well known to allow reaching high quality optical surfaces in a minimum time period, thanks to a spherical full-size polishing tool. To obtain the correct surface' aspheric shape, it is necessary to define precisely the thickness distribution of the mirror to be deformed, according to the manufacturing parameters. We first introduce active optics and Stress Mirror Polishing techniques, and then, we describe the process to obtain the appropriate thickness mirror distribution allowing to generate the required aspheric shape during polishing phase. Shape optimization procedure using PYTHON programing and NASTRAN optimization solver using Finite Element Model (FEM) is developed and discussed in order to assist this process. The main result of this paper is the ability of the shape optimization process to support SMP technique to generate a peculiar aspherical shape from a spherical optical surface thanks to a thickness distribution reshaping. This paper is primarily focused on a theoretical framework with numerical simulations as the first step before the manufacturing of a demonstrator. This two-steps approach was successfully used for previous projects.
[3]  oai:arXiv.org:1908.05951  [pdf] - 1944329
The Search for Living Worlds and the Connection to Our Cosmic Origins
Comments: Submission to the European Space Agency Voyage 2050 call for white papers
Submitted: 2019-08-16
One of the most exciting scientific challenges is to detect Earth-like planets in the habitable zones of other stars in the galaxy and search for evidence of life. The ability to observe and characterise dozens of potentially Earth-like planets now lies within the realm of possibility due to rapid advances in key space and imaging technologies. The associated challenge of directly imaging very faint planets in orbit around nearby very bright stars is now well understood, with the key instrumentation also being perfected and developed. Such advances will allow us to develop large transformative telescopes, covering a broad UV-optical-IR spectral range, which can carry out the detailed research programmes designed to answer the questions we wish to answer: Carry out high contrast imaging surveys of nearby stars to search for planets within their habitable zones. Characterise the planets detected to determine masses and radii from photometric measurements. Through spectroscopic studies of their atmospheres and surfaces, search for habitability indicators and for signs of an environment that has been modified by the presence of life. Active studies of potential missions have been underway for a number of years. The latest of these is the Large UV Optical IR space telescope (LUVOIR), one of four flagship mission studies commissioned by NASA in support of the 2020 US Decadal Survey. LUVOIR, if selected, will be of interest to a wide scientific community and will be the only telescope capable of searching for and characterizing a sufficient number of exoEarths to provide a meaningful answer to the question - Are we alone?. This paper is a submission to the European Space Agency Voyage 2050 call for white papers outlining the case for an ESA contribution to a Large UVOIR telescope.
[4]  oai:arXiv.org:1901.04050  [pdf] - 1814326
Key Technologies for the Wide Field Infrared Survey Telescope Coronagraph Instrument
Comments: Submitted in response to the 2018 NAS Exoplanet Science Strategy call. 5 pages, 2 figures
Submitted: 2019-01-13
The Wide Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument (CGI) is a high-contrast imager and integral field spectrograph that will enable the study of exoplanets and circumstellar disks at visible wavelengths. Ground-based high-contrast instrumentation has fundamentally limited performance at small working angles, even under optimistic assumptions for 30m-class telescopes. There is a strong scientific driver for better performance, particularly at visible wavelengths. Future flagship mission concepts aim to image Earth analogues with visible light flux ratios of more than 10^10. CGI is a critical intermediate step toward that goal, with a predicted 10^8-9 flux ratio capability in the visible. CGI achieves this through improvements over current ground and space systems in several areas: (i) Hardware: space-qualified (TRL9) deformable mirrors, detectors, and coronagraphs, (ii) Algorithms: wavefront sensing and control; post-processing of integral field spectrograph, polarimetric, and extended object data, and (iii) Validation of telescope and instrument models at high accuracy and precision. This white paper, submitted to the 2018 NAS Exoplanet Science Strategy call, describes the status of key CGI technologies and presents ways in which performance is likely to evolve as the CGI design matures.
[5]  oai:arXiv.org:1812.10484  [pdf] - 1953381
Design and modelling of spectrographs with holographic gratings on freeform surfaces
Comments: 37 pages, 19 figures, 2 tables. arXiv admin note: substantial text overlap with arXiv:1805.09073
Submitted: 2018-12-26
In the present paper we demonstrate the approach of using a holographic grating on a freeform surface for advanced spectrographs design. We discuss the surface and groove pattern description used for ray-tracing. Moreover, we present a general procedure of diffraction efficiency calculation, which accounts for the change of hologram recording and operation conditions across the surface. The primary application of this approach is the optical design of the POLLUX spectropolarimeter for the LUVOR mission project where a freeform holographic grating operates simultaneously as a cross-disperser and a camera with high resolution and high dispersion. The medium ultraviolet channel design of POLLUX is considered in detail as an example. Its resolving power reaches [126,000-133,000] in the region of 118.5-195 nm. Also, we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 4000 in the region 350-550 nm and remains stable along the slit.
[6]  oai:arXiv.org:1810.06478  [pdf] - 1766518
James Webb Space Telescope Optical Simulation Testbed V: Wide-field phase retrieval assessment
Comments: 13 pages, 6 figures
Submitted: 2018-10-15
The James Webb Space Telescope (JWST) Optical Simulation Testbed (JOST) is a hardware simulator for wavefront sensing and control designed to produce JWST-like images. A model of the JWST three mirror anas- tigmat is realized with three lenses in the form of a Cooke triplet, which provides JWST-like optical quality over a field equivalent to a NIRCam module. An Iris AO hexagonally segmented mirror stands in for the JWST primary. This setup successfully produces images extremely similar to expected JWST in-flight point spread functions (PSFs), and NIRCam images from cryotesting, in terms of the PSF morphology and sampling relative to the diffraction limit. The segmentation of the primary mirror into subapertures introduces complexity into wavefront sensing and control (WFS&C) of large space based telescopes like JWST. JOST provides a platform for independent analysis of WFS&C scenarios for both commissioning and maintenance activities on such ob- servatories. We present an update of the current status of the testbed including both single field and wide-field alignment results. We assess the optical quality of JOST over a wide field of view to inform the future imple- mentation of different wavefront sensing algorithms including the currently implemented Linearized Algorithm for Phase Diversity (LAPD). JOST complements other work at the Makidon Laboratory at the Space Telescope Science Institute, including the High-contrast imager for Complex Aperture Telescopes (HiCAT) testbed, that investigates coronagraphy for segmented aperture telescopes. Beyond JWST we intend to use JOST for WFS&C studies for future large segmented space telescopes such as LUVOIR.
[7]  oai:arXiv.org:1807.02172  [pdf] - 1711615
Curved detectors developments and characterization: application to astronomical instruments
Comments:
Submitted: 2018-07-05
Many astronomical optical systems have the disadvantage of generating curved focal planes requiring flattening optical elements to project the corrected image on flat detectors. The use of these designs in combination with a classical flat sensor implies an overall degradation of throughput and system performances to obtain the proper corrected image. With the recent development of curved sensor this can be avoided. This new technology has been gathering more and more attention from a very broad community, as the potential applications are multiple: from low-cost commercial to high impact scientific systems, to mass-market and on board cameras, defense and security, and astronomical community. We describe here the first concave curved CMOS detector developed within a collaboration between CNRS- LAM and CEA-LETI. This fully-functional detector 20 Mpix (CMOSIS CMV20000) has been curved down to a radius of Rc = 150 mm over a size of 24x32 mm^2 . We present here the methodology adopted for its characterization and describe in detail all the results obtained. We also discuss the main components of noise, such as the readout noise, the fixed pattern noise and the dark current. Finally we provide a comparison with the flat version of the same sensor in order to establish the impact of the curving process on the main characteristics of the sensor.
[8]  oai:arXiv.org:1806.08168  [pdf] - 1703370
Design of optical systems with toroidal curved detectors
Comments: 4 pages, 7 figures
Submitted: 2018-06-21
We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured re-imaging three-mirror anastigmat as an example (f'=960 mm, F/5.3, FoV 4x4 degrees). By assuming that the image is focused on a toroidal detector surface and perform re-optimization, it becomes possible to obtain a notable gain in the image quality - up to 40 % in terms of the spot RMS radius. Through analytic computations and finite-element analysis, we demonstrate that this toroidal shape can be obtained by bending of a thinned detector in a relatively simple setup.
[9]  oai:arXiv.org:1805.09069  [pdf] - 1688203
Curved detectors for wide field imaging systems: impact on tolerance analysis
Comments:
Submitted: 2018-05-23
In the present paper we consider quantitative estimation of the tolerances widening in optical systems with curved detectors. The gain in image quality allows to loosen the margins for manufacturing and assembling errors. On another hand, the requirements for the detector shape and positioning become more tight. We demonstrate both of the effects on example of two optical designs. The first one is a rotationally-symmetrical lens with focal length of 25 mm, f-ratio of 3.5 and field of view equal to 72$^\circ$, working in the visible domain. The second design is a three-mirror anastigmat telescope with focal length of 250 mm, f-ratio of 2.0 and field of view equal to $4^\circ \times 4^\circ$. In both of the cases use of curved detectors allow to increase the image quality and substantially decrease the requirements for manufacturing precision
[10]  oai:arXiv.org:1805.09073  [pdf] - 1688205
Spectrographs with holographic gratings on freeform surfaces: design approach and application for the LUVOIR mission
Comments:
Submitted: 2018-05-23
In the present paper we demonstrate the approach to use a holographic grating on a freeform surface for advanced spectrographs design. On the example POLLUX spectropolarimeter medium-UV channel we chow that such a grating can operate as a cross-disperser and a camera mirror at the same time. It provides the image quality high enough to reach the spectral resolving power of 126 359-133 106 between 11.5 and 195 nm, which is higher than the requirement. Also we show a possibility to use a similar element working in transmission to build an unobscured double-Schmidt spectrograph. The spectral resolving power reaches 2750 for a long slit. It is also shown that the parameters of both the gratings are feasible with the current technologies.
[11]  oai:arXiv.org:1805.09067  [pdf] - 1688202
POLLUX: a UV spectropolarimeter for the LUVOIR space telescope project
Comments:
Submitted: 2018-05-23
The present paper describes the current baseline optical design of POLLUX, a high-resolution spectropolarimeter for the future LUVOIR mission. The instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in both spectropolarimetric and pure spectroscopic modes. The working range is split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near (195-390 nm) UV. Each of the channels is composed of a polarimeter followed by an echelle spectrograph consisting of a classical off-axis paraboloid collimator, echelle grating with a high grooves frequency and a cross-disperser grating operating also as a camera. The latter component integrates some advanced technologies: it is a blazed grating with a complex grooves pattern formed by holographic recording, which is manufactured on a freeform surface. One of the key features underlying the current design is the large spectral length of each order ~6 nm, which allows to record wide spectral lines without any discontinuities. The modelling results show that the optical design will provide the required spectral resolving power higher than R ~ 120,000 over the entire working range for a point source object with angular size of 30 mas. It is also shown that with the 15-m primary mirror of the LUVOIR telescope the instrument will provide an effective collecting area up to 38 569 cm 2. Such a performance will allow to perform a number of groundbreaking scientific observations. Finally, the future work and the technological risks of the design are discussed in details.
[12]  oai:arXiv.org:1805.09071  [pdf] - 1688204
Advanced optical designs of curved detectors-based two-mirrors unobscured telescopes
Comments:
Submitted: 2018-05-23
In the present paper we consider a family of unobscured telescope designs with curved detectors. They are based on classical two-mirror schemes -- Ritchey-Chretien, Gregorian and Couder telescopes. It is shown that all the designs provide nearly diffraction limited image quality in the visible domain for $.4^\circ \times .4^\circ$ field of view with the f-number of 7. We also provide a brief ghost analysis and point on special features of the systems with curved detectors. Finally, the detector surface shape obtained in each case is analyzed and its' technological feasibility is demonstrated.
[13]  oai:arXiv.org:1710.08776  [pdf] - 1686650
A fast, wide-field and distortion-free telescope with curved detectors for surveys at ultra-low surface brightness
Comments: 10 pages, 10 figures, 2 tables
Submitted: 2017-10-24, last modified: 2017-10-25
We present the design of an all-reflective, bi-folded Schmidt telescope aimed at surveys of extended astronomical objects with extremely-low surface brightness. The design leads to a high image quality without any diffracting spider, along with a large aperture and field of view, with a small central obstruction which barely alters the PSF. As an example, we present the design of a high-quality, 36 cm diameter, fast ( f /2.5) telescope working in the visible with a large field of view (1.6{\deg}x 2.6{\deg}). The telescope can operate with a curved detector (or with a flat detector with a field flattener) and a set of filters. The entrance mirror is anamorphic and replaces the classical Schmidt entrance corrector plate. We show that this anamorphic primary mirror can be manufactured through stress polishing, avoiding high spatial frequency errors, and tested with a simple interferometer scheme. This prototype is intended to serve as a fast-track scientific and technological pathfinder for the future space-based MESSIER mission.
[14]  oai:arXiv.org:1706.05520  [pdf] - 1584827
Combining freeform optics and curved detectors for wide field imaging: a polynomial approach over squared aperture
Comments: 14 pages, 10 figures, 5 tables, to be published in Optics Express Vol. 25, Iss. 13 - June 26, 2017
Submitted: 2017-06-17
In the recent years a significant progress was achieved in the field of design and fabrication of optical systems based on freeform optical surfaces. They provide a possibility to build fast, wide-angle and high-resolution systems, which are very compact and free of obscuration. However, the field of freeform surfaces design techniques still remains underexplored. In the present paper we use the mathematical apparatus of orthogonal polynomials defined over a square aperture, which was developed before for the tasks of wavefront reconstruction, to describe shape of a mirror surface. Two cases, namely Legendre polynomials and generalization of the Zernike polynomials on a square, are considered. The potential advantages of these polynomials sets are demonstrated on example of a three-mirror unobscured telescope with F/#=2.5 and FoV=7.2x7.2{\deg}. In addition, we discuss possibility of use of curved detectors in such a design.
[15]  oai:arXiv.org:1607.06272  [pdf] - 1531078
Flexible focal plane arrays for UVOIR wide field instrumentation
Comments: SPIE proceeding on Astronomical Telescopes and Instrumentation, 9 pages, 12 figures
Submitted: 2016-07-21
LAM and CEA-LETI are developing the technology of deformable detectors, for UV, VIS or NIR applications. Such breakthrough devices will be a revolution for future wide field imagers and spectrographs, firstly by improving the image quality with better off-axis sharpness, resolution, brightness while scaling down the optical system, secondly by overcoming the manufacturing issues identified so far and by offering a flexibility and versatility in optical design. The technology of curved detectors can benefit of the developments of active and deformable structures, to provide a flexibility and a fine tuning of the detectors curvature by thinning down the substrate without modifying the fabrication process of the active pixels. We present studies done so far on optical design improvements, the technological demonstrators we developed and their performances as well as the future five-years roadmap for these developments.
[16]  oai:arXiv.org:1512.05378  [pdf] - 1354861
Apodization in high-contrast long-slit spectroscopy. II. Concept validation and first on-sky results with VLT/SPHERE
Comments: 13 pages, 13 figures. Accepted for publication in A&A
Submitted: 2015-12-16
Spectral characterization of young, giant exoplanets detected by direct imaging is one of the tasks of the new generation of high-contrast imagers. For this purpose, the VLT/SPHERE instrument includes a unique long-slit spectroscopy (LSS) mode coupled with Lyot coronagraphy in its infrared dual-band imager and spectrograph (IRDIS). The performance of this mode is intrinsically limited by the use of a non-optimal coronagraph, but in a previous work we demonstrated that it could be significantly improved at small inner-working angles using the stop-less Lyot coronagraph (SLLC). We now present the development, testing, and validation of the first SLLC prototype for VLT/SPHERE. Based on the transmission profile previously proposed, the prototype was manufactured using microdots technology and was installed inside the instrument in 2014. The transmission measurements agree well with the specifications, except in the very low transmissions (<5% in amplitude). The performance of the SLLC is tested in both imaging and spectroscopy using data acquired on the internal source. In imaging, we obtain a raw contrast gain of a factor 10 at 0.3" and 5 at 0.5" with the SLLC. Using data acquired with a focal-plane mask, we also demonstrate that no Lyot stop is required to reach the full performance, which validates the SLLC concept. Comparison with a realistic simulation model shows that we are currently limited by the internal phase aberrations of SPHERE. In spectroscopy, we obtain a gain of ~1 mag in a limited range of angular separations. Simulations show that although the main limitation comes from phase errors, the performance in the non-SLLC case is very close to the ultimate limit of the LSS mode. Finally, we obtain the very first on-sky data with the SLLC, which appear extremely promising for the future scientific exploitation of an apodized LSS mode in SPHERE.
[17]  oai:arXiv.org:1411.4807  [pdf] - 904017
Active optics for high-dynamic variable curvature mirrors
Comments: 3 pages, 4 figures
Submitted: 2014-11-18
Variable curvature mirrors of large amplitude are designed by using finite element analysis. The specific case studied reaches at least a 800 {\mu}m sag with an optical quality better than {\lambda}/5 over a 120 mm clear aperture. We highlight the geometrical nonlinearity and the plasticity effect.
[18]  oai:arXiv.org:1411.4473  [pdf] - 900960
Design and development of a freeform active mirror for an astronomy application
Comments: 11 pages, 12 figures
Submitted: 2014-11-17
The advent of extremely large telescopes will bring unprecedented light-collecting power and spatial resolution, but it will also lead to a significant increase in the size and complexity of focal-plane instruments. The use of freeform mirrors could drastically reduce the number of components in optical systems. Currently, manufacturing issues limit the common use of freeform mirrors at short wavelengths. This article outlines the use of freeform mirrors in astronomical instruments with a description of two efficient freeform optical systems. A new manufacturing method is presented which seeks to overcome the manufacturing issues through hydroforming of thin polished substrates. A specific design of an active array is detailed, which will compensate for residual manufacturing errors, thermoelastic deformation, and gravity-induced errors during observations. The combined hydroformed mirror and the active array comprise the Freeform Active Mirror Experiment, which will produce an accurate, compact, and stable freeform optics dedicated to visible and near-infrared observations.
[19]  oai:arXiv.org:1409.2247  [pdf] - 1216772
Compensation of high-order quasi-static aberrations on SPHERE with the coronagraphic phase diversity (COFFEE)
Comments: Accepted in Astronomy & Astrophysics
Submitted: 2014-09-08
The second-generation instrument SPHERE, dedicated to high-contrast imaging, will soon be in operation on the European Very Large Telescope. Such an instrument relies on an extreme adaptive optics system coupled with a coronagraph that suppresses most of the diffracted stellar light. However, the coronagraph performance is strongly limited by quasi-static aberrations that create long-lived speckles in the scientific image plane, which can easily be mistaken for planets. The ultimate performance is thus limited by the unavoidable differential aberrations between the wave-front sensor and the scientific camera, which have to be estimated andcompensated for. In this paper, we use the COFFEE approach to measure and compensate for SPHERE's quasi-static aberrations. COFFEE (for COronagraphic Focal-plane wave-Front Estimation for Exoplanet detection), which consists in an extension of phase diversity to coronagraphic imaging, estimates the quasi-static aberrations, including the differential ones, using only two focal plane images recorded by the scientific camera. In this paper, we use coronagraphic images recorded from SPHERE's infrared detector IRDIS to estimate the aberrations upstream of the coronagraph, which are then compensated for using SPHERE's extreme adaptive optics loop SAXO. We first validate the ability of COFFEE to estimate high-order aberrations by estimating a calibrated influence function pattern introduced upstream of the coronagraph. We then use COFFEE in an original iterative compensation process to compensate for the estimated aberrations, leading to a contrast improvement by a factor that varies from 1.4 to 4.7 between 2l/D and 15l/D on IRDIS. The performance of the compensation process is also evaluated through simulations. An excellent match between experimental results and these simulations is found.
[20]  oai:arXiv.org:1408.7069  [pdf] - 1216582
Local ensemble transform Kalman filter, a fast non-stationary control law for adaptive optics on ELTs: theoretical aspects and first simulation results
Comments: This paper was published in Optics Express and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/oe/ . Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law
Submitted: 2014-08-29
We propose a new algorithm for an adaptive optics system control law, based on the Linear Quadratic Gaussian approach and a Kalman Filter adaptation with localizations. It allows to handle non-stationary behaviors, to obtain performance close to the optimality defined with the residual phase variance minimization criterion, and to reduce the computational burden with an intrinsically parallel implementation on the Extremely Large Telescopes (ELTs).
[21]  oai:arXiv.org:1407.0980  [pdf] - 1215385
High-contrast imager for Complex Aperture Telescopes (HiCAT): 2. Design overview and first light results
Comments: Proc. of the SPIE 2014, 9143-71. 11 pages, 8 figures
Submitted: 2014-07-03
We present a new high-contrast imaging testbed designed to provide complete solutions in wavefront sensing, control and starlight suppression with complex aperture telescopes. The testbed was designed to enable a wide range of studies of the effects of such telescope geometries, with primary mirror segmentation, central obstruction, and spiders. The associated diffraction features in the point spread function make high-contrast imaging more challenging. In particular the testbed will be compatible with both AFTA-like and ATLAST-like aperture shapes, respectively on-axis monolithic, and on-axis segmented telescopes. The testbed optical design was developed using a novel approach to define the layout and surface error requirements to minimize amplitude-induced errors at the target contrast level performance. In this communication we compare the as-built surface errors for each optic to their specifications based on end-to-end Fresnel modeling of the testbed. We also report on the testbed optical and optomechanical alignment performance, coronagraph design and manufacturing, and preliminary first light results.
[22]  oai:arXiv.org:1305.0476  [pdf] - 659115
Mirror actively deformed and regulated for applications in space: design and performance
Comments: 12 pages, 12 figures
Submitted: 2013-05-02
The need for both high quality images and lightweight structures is one of the main drivers in space telescope design. An efficient wavefront control system will become mandatory in future large observatories, retaining performance while relaxing specifications in the global system's stability. We present the mirror actively deformed and regulated for applications in space project, which aims to demonstrate the applicability of active optics for future space instrumentation. It has led to the development of a 24-actuator, 90-mm-diameter active mirror, able to compensate for large lightweight primary mirror deformations in the telescope's exit pupil. The correcting system has been designed for expected wavefront errors from 3-m-class lightweight primary mirrors, while also taking into account constraints for space use. Finite element analysis allowed an optimization of the system in order to achieve a precision of correction better than 10 nm rms. A dedicated testbed has been designed to fully characterize the integrated system performance in representative operating conditions. It is composed of: a telescope simulator, an active correction loop, a point spread function imager, and a Fizeau interferometer. All conducted tests demonstrated the correcting mirror performance and has improved this technology maturity to a TRL4.
[23]  oai:arXiv.org:1209.2685  [pdf] - 562650
Active optics: deformable mirrors with a minimum number of actuators
Comments: 13 pages, 9 figures, published in JEOS
Submitted: 2012-09-12
We present two concepts of deformable mirror to compensate for first order optical aberrations. Deformation systems are designed using both elasticity theory and Finite Element Analysis in order to minimize the number of actuators. Starting from instrument specifications, we explain the methodology to design dedicated deformable mirrors. The work presented here leads to correcting devices optimized for specific functions. The Variable Off-Axis paraboLA concept is a 3-actuators, 3-modes system able to generate independently Focus, Astigmatism and Coma. The Correcting Optimized Mirror with a Single Actuator is a 1-actuator system able to generate a given combination of optical aberrations.
[24]  oai:arXiv.org:0811.2496  [pdf] - 18579
Diversity among other worlds: characterization of exoplanets by direct detection
Comments: Update of a White Paper submitted to the ESA ExoPlanet Roadmap Advisory Team
Submitted: 2008-11-15, last modified: 2008-12-04
The physical characterization of exoplanets will require to take spectra at several orbital positions. For that purpose, a direct imaging capability is necessary. Direct imaging requires an efficient stellar suppression mechanism, associated with an ultrasmooth telescope. We show that before future large space missions (interferometer, 4-8 m class coronograph, external occulter or Fresnel imager), direct imaging of giant planets and close-by super-Earth are at the cross-road of a high scientific interest and a reasonable feasibility. The scientific interest lies in the fact that super-Earths share common geophysical attributes with Earths. They already begin to be detected by radial velocity (RV) and, together with giant planets, they have a larger area than Earths, making them detectable with a 1.5-2 m class telescope in reflected light. We propose such a (space) telescope be a first step before large direct imaging missions.
[25]  oai:arXiv.org:0802.0611  [pdf] - 9779
The Wide-field High-resolution Infrared TElescope (WHITE)
Comments: Invited talk to the 2nd ARENA Conference : "The Astrophysical Science Cases at Dome C" Potsdam 17-21 September, 2007
Submitted: 2008-02-05
The Wide-field High-resolution Infrared TElescope (WHITE) will be dedicated in the first years of its life to carrying out a few (well focused in terms of science objectives and time) legacy surveys. WHITE would have an angular resolution of ~0.3'' homogeneous over ~0.7 sq. deg. in the wavelength range 1 - 5 um, which means that we will very efficiently use all the available observational time during night time and day time. Moreover, the deepest observations will be performed by summing up shorter individual frames. We will have a temporal information that can be used to study variable objects. The three key science objectives of WHITE are : 1) A complete survey of the Magellanic Clouds to make a complete census of young stellar objects in the clouds and in the bridge and to study their star formation history and the link with the Milky Way. The interaction of the two clouds with our Galaxy might the closest example of a minor merging event that could be the main driver of galaxy evolution in the last 5 Gyrs. 2) The building of the first sample of dusty supernovae at z<1.2 in the near infrared range (1-5 um) to constrain the equation of state from these obscured objects, study the formation of dust in galaxies and build the first high resolution sample of high redshift galaxies observed in their optical frame 3) A very wide weak lensing survey over that would allow to estimate the equation of state in a way that would favourably compete with space projects.
[26]  oai:arXiv.org:astro-ph/0611556  [pdf] - 86942
Wide Field Astronomy at Dome C: two IR surveys complementary to SNAP
Comments: Invited contribution to the 1st ARENA Conference on "Large Astronomical Infrastructures at CONCORDIA, prospects and constraints for Antarctic optical/IR Astronomy": 8 pages, 5 Postscript figures
Submitted: 2006-11-17
Surveys provide a wealth of data to the astronomical community that are used well after their completion. In this paper, we propose a project that would take the maximum benefit of Dome C in Antarctica by performing two surveys, in the wavelength range from 1-5 micron, complementary to SNAP space surveys. The first one over 1000 sq. deg. (1 KdF) for 4 years and the second one over 15 sq. deg (SNAP-IR) for the next 4 years at the same time as SNAP 0.35-1.7 microns survey. By using a Ground-Layer Adaptive Optics system, we would be able to recover, at the ice level and over at least half a degree in radius, the 300 mas angular resolution available above the 30-m high turbulent layer. Such a survey, combining a high angular resolution with high sensitivities in the NIR and MIR, should also play the role of a pre-survey for JWST and ALMA.
[27]  oai:arXiv.org:astro-ph/9608154  [pdf] - 1234749
Liquid Mirror Telescopes: A progress report
Comments: To appear in the SPIE conference proceedings 'Optical Telescopes of Today and Tomorrow', May 29 - June1, Landskrona/Hven, Sweden, Additional info on LMs at: http://astrosun.phy.ulaval.ca/lmt/lmt-home.html
Submitted: 1996-08-23
We review the present status of liquid mirror telescopes. Interferometric tests of liquid mirrors (the largest one having a diameter of 2.5 meters ) show excellent optical qualities. The basic technology is now sufficiently reliable that it can be put to work. Indeed, a handful of liquid mirrors have now been built that are used for scientific work. A 3.7-m diameter LMT is presently being built in the new Laval upgraded testing facilities. Construction of the mirror can be followed on the Web site: http://astrosun.phy.ulaval.ca/lmt/lmt- home.html. Finally we address the issue of the field accessible to LMTs equipped with novel optical correctors. Optical design work, and some exploratory laboratory work, indicate that a single LMT should be able to access, with excellent images, small regions anywhere inside fields as large as 45 degrees.
[28]  oai:arXiv.org:astro-ph/9504009  [pdf] - 1942411
Active vase mirrors warped by Zernike polynomials for Correcting off-axis aberrations of fixed primary mirrors. Part 2 - Optical testing and performance evaluation
Comments: 8 pages of uuencoded compressed postscript, including 9 figures, 7 figure sent upon request. To appear in Astronomy & Astrophysics Suppl
Submitted: 1995-04-04
We investigate the aspherization of an active mirror for correcting third and fifth-order aberrations. We use a stainless steel AISI 420 mirror with a controlled pressure load, two series of 12-punctual radial positions of force application distributed symmetrically in two concentric rings around the mirror. We obtain the wavefronts for Cv1, Sph3, Coma3, Astm3, Comatri, Astm5 aswell as those of the added wavefronts. Although this active prototype mirror has general uses, our goal is to compensate the aberrations of a liquid mirror observing at large angles from the zenith.