Normalized to: Fernandez, A.
[1]
oai:arXiv.org:1404.1455 [pdf] - 1693885
First Axion Results from the XENON100 Experiment
The XENON100 Collaboration;
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2014-04-05, last modified: 2016-12-22
We present the first results of searches for axions and axion-like-particles
with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$,
has been probed by exploiting the axio-electric effect in liquid xenon. A
profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has
shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times
10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on
this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions
heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For
axion-like-particles, under the assumption that they constitute the whole
abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than
$1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set
the best limit to date as well.
[2]
oai:arXiv.org:1605.06262 [pdf] - 1530726
A low-mass dark matter search using ionization signals in XENON100
XENON100 Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Bruenner, E. Brown S.;
Bruno, G.;
Budnik, R.;
Buss, A.;
Bütikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Duchovni, E.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Gross, E.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Calloch, M. Le;
Levy, C.;
Linde, F.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C. D.;
von Sivers, M.;
Wall, R.;
Wang, H.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Zhang, Y.
Submitted: 2016-05-20, last modified: 2016-12-19
We perform a low-mass dark matter search using an exposure of
30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a
scintillation signal and using only the ionization signal to determine the
interaction energy, we lowered the energy threshold for detection to 0.7\,keV
for nuclear recoils. No dark matter detection can be claimed because a complete
background model cannot be constructed without a primary scintillation signal.
Instead, we compute an upper limit on the WIMP-nucleon scattering cross section
under the assumption that every event passing our selection criteria could be a
signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a
limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs
with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\%
confidence level.
[3]
oai:arXiv.org:1512.07501 [pdf] - 1395004
Physics reach of the XENON1T dark matter experiment
The XENON collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arazi, L.;
Arneodo, F.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Berger, T.;
Breur, P.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Hasterok, C.;
Itay, R.;
Kaether, F.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Calloch, M. Le;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
von Sivers, M.;
Wall, R.;
Wang, H.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Zhang, Y.
Submitted: 2015-12-23, last modified: 2016-04-15
The XENON1T experiment is currently in the commissioning phase at the
Laboratori Nazionali del Gran Sasso, Italy. In this article we study the
experiment's expected sensitivity to the spin-independent WIMP-nucleon
interaction cross section, based on Monte Carlo predictions of the electronic
and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$,
$12$) keV electronic recoil equivalent energy region, before applying any
selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm
0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the
decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil
background in the corresponding nuclear recoil equivalent energy region ($4$,
$50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from
radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from
coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$
from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio
method, after converting the deposited energy of electronic and nuclear recoils
into the scintillation and ionization signals seen in the detector. We take
into account the systematic uncertainties on the photon and electron emission
model, and on the estimation of the backgrounds, treated as nuisance
parameters. The main contribution comes from the relative scintillation
efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs
and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial
volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$
cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
[4]
oai:arXiv.org:1512.06694 [pdf] - 1363913
Testing sky brightness models against radial dependency: a dense two
dimensional survey around the city of Madrid, Spain
Zamorano, Jaime;
de Miguel, Alejandro Sánchez;
Ocaña, Francisco;
Pila-Diez, Berenice;
Castaño, José Gómez;
Pascual, Sergio;
Tapia, Carlos;
Gallego, Jesús;
Fernandez, Alberto;
Nievas, Miguel
Submitted: 2015-12-21
We present a study of the night sky brightness around the extended
metropolitan area of Madrid using Sky Quality Meter (SQM) photometers. The map
is the first to cover the spatial distribution of the sky brightness in the
center of the Iberian peninsula. These surveys are neccessary to test the light
pollution models that predict night sky brightness as a function of the
location and brightness of the sources of light pollution and the scattering of
light in the atmosphere. We describe the data-retrieval methodology, which
includes an automated procedure to measure from a moving vehicle in order to
speed up the data collection, providing a denser and wider survey than previous
works with similar time frames. We compare the night sky brightness map to the
nocturnal radiance measured from space by the DMSP satellite. We find that i) a
single source model is not enough to explain the radial evolution of the night
sky brightness, despite the predominance of Madrid in size and population, and
ii) that the orography of the region should be taken into account when deriving
geo-specific models from general first-principles models. We show the tight
relationship between these two luminance measures. This finding sets up an
alternative roadmap to extended studies over the globe that will not require
the local deployment of photometers or trained personnel.
[5]
oai:arXiv.org:1510.04360 [pdf] - 1294131
SOFIA/FORCAST Observations of Warm Dust in S106: A Fragmented
Environment
Adams, J. D.;
Herter, T. L.;
Hora, J. L.;
Schneider, N.;
Lau, R. M.;
Staughn, J. G.;
Simon, R.;
Smith, N.;
Gehrz, R. D.;
Allen, L. E.;
Bontemps, S.;
Carey, S. J.;
Fazio, G. G.;
Gutermuth, R. A.;
Fernandez, A. Guzman;
Hankins, M.;
Hill, T.;
Keto, E.;
Koenig, X. P.;
Kraemer, K. E.;
Megeath, S. T.;
Mizuno, D. R.;
Motte, F.;
Myers, P. C.;
Smith, H. A.
Submitted: 2015-10-14
We present mid-IR (19 - 37 microns) imaging observations of S106 from
SOFIA/FORCAST, complemented with IR observations from Spitzer/IRAC (3.6 - 8.0
microns), IRTF/MIRLIN (11.3 and 12.5 microns), and Herschel/PACS (70 and 160
microns). We use these observations, observations in the literature, and
radiation transfer modeling to study the heating and composition of the warm (~
100 K) dust in the region. The dust is heated radiatively by the source S106
IR, with little contributions from grain-electron collisions and Ly-alpha
radiation. The dust luminosity is >~ (9.02 +/- 1.01) x 10^4 L_sun, consistent
with heating by a mid- to late-type O star. We find a temperature gradient (~
75 - 107 K) in the lobes, which is consistent with a dusty equatorial geometry
around S106 IR. Furthermore, the SOFIA observations resolve several cool (~ 65
- 70 K) lanes and pockets of warmer (~ 75 - 90 K) dust in the ionization
shadow, indicating that the environment is fragmented. We model the dust mass
as a composition of amorphous silicates, amorphous carbon, big grains, very
small grains, and PAHs. We present the relative abundances of each grain
component for several locations in S106.
[7]
oai:arXiv.org:1507.07747 [pdf] - 1264865
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic
Recoil Data
The XENON Collaboration;
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arazi, L.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Coderre, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vitells, O.;
Wall, R.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2015-07-28
Laboratory experiments searching for galactic dark matter particles
scattering off nuclei have so far not been able to establish a discovery. We
use data from the XENON100 experiment to search for dark matter interacting
with electrons. With no evidence for a signal above the low background of our
experiment, we exclude a variety of representative dark matter models that
would induce electronic recoils. For axial-vector couplings to electrons, we
exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2
GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as
explanation for the long-standing DAMA/LIBRA signal, such as couplings to
electrons through axial-vector interactions at a 4.4 sigma confidence level,
mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
[8]
oai:arXiv.org:1503.07698 [pdf] - 1342737
Lowering the radioactivity of the photomultiplier tubes for the XENON1T
dark matter experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arazi, L.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Cardoso, J. M. R.;
Coderre, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowksi, M. P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vitells, O.;
Wall, R.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Laubenstein, M.
Submitted: 2015-03-26
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.
[9]
oai:arXiv.org:1406.2374 [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the
XENON1T experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Lyashenko, A.;
MacMullin, S.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer., C.
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.
[10]
oai:arXiv.org:1408.3477 [pdf] - 1216315
VAMOS: a Pathfinder for the HAWC Gamma-Ray Observatory
Abeysekara, A. U.;
Alfaro, R.;
Alvarez, C.;
Álvarez, J. D.;
Ángeles, F.;
Arceo, R.;
Arteaga-Velázquez, J. C.;
Avila-Aroche, A.;
Solares, H. A. Ayala;
Badillo, C.;
Barber, A. S.;
Baughman, B. M.;
Bautista-Elivar, N.;
Gonzalez, J. Becerra;
Belmont, E.;
Benítez, E.;
BenZvi, S. Y.;
Berley, D.;
Bernal, A.;
Rosales, M. Bonilla;
Braun, J.;
Caballero-Lopez, R. A.;
Caballero-Mora, K. S.;
Cabrera, I.;
Carramiñana, A.;
Castañeda-Martínez, L.;
Castillo, M.;
Cotti, U.;
Cotzomi, J.;
de la Fuente, E.;
De León, C.;
DeYoung, T.;
Diaz-Azuara, A.;
Diaz-Cruz, L.;
Hernandez, R. Diaz;
Díaz-Vélez, J. C.;
Dingus, B. L.;
Dultzin, D.;
DuVernois, M. A.;
Ellsworth, R. W.;
Fernandez, A.;
Fiorino, D. W.;
Fraija, N.;
Galindo, A.;
García-Torales, G.;
Garfias, F.;
González, A.;
González, L. X.;
González, M. M.;
Goodman, J. A.;
Grabski, V.;
Gussert, M.;
Guzmán-Cerón, C.;
Hampel-Arias, Z.;
Harding, J. P.;
Hernández-Cervantes, L.;
Hui, C. M.;
Hüntemeyer, P.;
Imran, A.;
Iriarte, A.;
Karn, P.;
Kieda, D.;
Kunde, G. J.;
Langarica, R.;
Lara, A.;
Lara, G.;
Lauer, R. J.;
Lee, W. H.;
Lennarz, D.;
Vargas, H. León;
Linares, E. C.;
Linnemann, J. T.;
Longo, M.;
Luna-Garcia, R.;
Marinelli, A.;
Martínez, L. A.;
Martínez, H.;
Martínez, O.;
Martínez-Castro, J.;
Martos, M.;
Matthews, J. A. J.;
McEnery, J.;
Torres, E. Mendoza;
Miranda-Romagnoli, P.;
Moreno, E.;
Mostafá, M.;
Nava, J.;
Nellen, L.;
Newbold, M.;
Noriega-Papaqui, R.;
Oceguera-Becerra, T.;
Page, D. P.;
Patricelli, B.;
Pelayo, R.;
Pérez-Pérez, E. G.;
Pretz, J.;
Ramírez, I.;
Renter, A.;
Rivière, C.;
Rosa-González, D.;
Ruiz-Sala, F.;
Ruiz-Velasco, E. L.;
Ryan, J.;
Sacahui, J. R.;
Salazar, H.;
Salesa, F.;
Sandoval, A.;
Santos, E.;
Schneider, M.;
Silich, S.;
Sinnis, G.;
Smith, A. J.;
Woodle, K. Sparks;
Springer, R. W.;
Suarez, F.;
Taboada, I.;
Tepe, A.;
Toale, P. A.;
Tollefson, K.;
Torres, I.;
Tinoco, S.;
Ukwatta, T. N.;
Galicia, J. F. Valdés;
Vanegas, P.;
Vázquez, A.;
Villaseñor, L.;
Wall, W.;
Weisgarber, T.;
Westerhoff, S.;
Wisher, I. G.;
Wood, J.;
Yodh, G. B.;
Younk, P. W.;
Zaborov, D.;
Zepeda, A.;
Zhou, H.
Submitted: 2014-08-15
VAMOS was a prototype detector built in 2011 at an altitude of 4100m a.s.l.
in the state of Puebla, Mexico. The aim of VAMOS was to finalize the design,
construction techniques and data acquisition system of the HAWC observatory.
HAWC is an air-shower array currently under construction at the same site of
VAMOS with the purpose to study the TeV sky. The VAMOS setup included six water
Cherenkov detectors and two different data acquisition systems. It was in
operation between October 2011 and May 2012 with an average live time of 30%.
Besides the scientific verification purposes, the eight months of data were
used to obtain the results presented in this paper: the detector response to
the Forbush decrease of March 2012, and the analysis of possible emission, at
energies above 30 GeV, for long gamma-ray bursts GRB111016B and GRB120328B.
[11]
oai:arXiv.org:1311.1088 [pdf] - 783783
Observation and applications of single-electron charge signals in the
XENON100 experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection
chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of
dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we
report the observation of single-electron charge signals which are not related
to WIMP interactions. These signals, which show the excellent sensitivity of
the detector to small charge signals, are explained as being due to the
photoionization of impurities in the liquid xenon and of the metal components
inside the TPC. They are used as a unique calibration source to characterize
the detector. We explain how we can infer crucial parameters for the XENON100
experiment: the secondary-scintillation gain, the extraction yield from the
liquid to the gas phase and the electron drift velocity.
[12]
oai:arXiv.org:1207.3458 [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D. B.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso,
aims at the direct detection of dark matter in the form of weakly interacting
massive particles (WIMPs), based on their interactions with xenon nuclei in an
ultra low background dual-phase time projection chamber. This paper describes
the general methods developed for the analysis of the XENON100 data. These
methods have been used in the 100.9 and 224.6 live days science runs from which
results on spin-independent elastic, spin-dependent elastic and inelastic
WIMP-nucleon cross-sections have already been reported.
[13]
oai:arXiv.org:1310.0074 [pdf] - 726324
The HAWC Gamma-Ray Observatory: Design, Calibration, and Operation
HAWC Collaboration;
Abeysekara, A. U.;
Alfaro, R.;
Alvarez, C.;
Álvarez, J. D.;
Arceo, R.;
Arteaga-Velázquez, J. C.;
Solares, H. A. Ayala;
Barber, A. S.;
Baughman, B. M.;
Bautista-Elivar, N.;
Belmont, E.;
BenZvi, S. Y.;
Berley, D.;
Rosales, M. Bonilla;
Braun, J.;
Caballero-Lopez, R. A.;
Caballero-Mora, K. S.;
Carramiñana, A.;
Castillo, M.;
Cotti, U.;
Cotzomi, J.;
de la Fuente, E.;
De León, C.;
DeYoung, T.;
Hernandez, R. Diaz;
Díaz-Vélez, J. C.;
Dingus, B. L.;
DuVernois, M. A.;
Ellsworth, R. W.;
Fernandez, A.;
Fiorino, D. W.;
Fraija, N.;
Galindo, A.;
Garfias, F.;
González, L. X.;
González, M. M.;
Goodman, J. A.;
Grabski, V.;
Gussert, M.;
Hampel-Arias, Z.;
Hui, C. M.;
Hüntemeyer, P.;
Imran, A.;
Iriarte, A.;
Karn, P.;
Kieda, D.;
Kunde, G. J.;
Lara, A.;
Lauer, R. J.;
Lee, W. H.;
Lennarz, D.;
Vargas, H. León;
Linares, E. C.;
Linnemann, J. T.;
Longo, M.;
Luna-GarcIa, R.;
Marinelli, A.;
Martinez, H.;
Martinez, O.;
Martínez-Castro, J.;
Matthews, J. A. J.;
Miranda-Romagnoli, P.;
Moreno, E.;
Mostafá, M.;
Nava, J.;
Nellen, L.;
Newbold, M.;
Noriega-Papaqui, R.;
Oceguera-Becerra, T.;
Patricelli, B.;
Pelayo, R.;
Pérez-Pérez, E. G.;
Pretz, J.;
Rivière, C.;
Rosa-González, D.;
Salazar, H.;
Salesa, F.;
Sanchez, F. E.;
Sandoval, A.;
Santos, E.;
Schneider, M.;
Silich, S.;
Sinnis, G.;
Smith, A. J.;
Sparks, K.;
Springer, R. W.;
Taboada, I.;
Toale, P. A.;
Tollefson, K.;
Torres, I.;
Ukwatta, T. N.;
Villaseñor, L.;
Weisgarber, T.;
Westerhoff, S.;
Wisher, I. G.;
Wood, J.;
Yodh, G. B.;
Younk, P. W.;
Zaborov, D.;
Zepeda, A.;
Zhou, H.
Submitted: 2013-09-30
The High-Altitude Water Cherenkov Gamma Ray Observatory (HAWC) is under
construction 4100 meters above sea level at Sierra Negra, Mexico. We describe
the design and cabling of the detector, the characterization of the
photomultipliers, and the timing calibration system. We also outline a
next-generation detector based on the water Cherenkov technique.
[14]
oai:arXiv.org:1310.0073 [pdf] - 726323
The HAWC Gamma-Ray Observatory: Dark Matter, Cosmology, and Fundamental
Physics
HAWC Collaboration;
Abeysekara, A. U.;
Alfaro, R.;
Alvarez, C.;
Álvarez, J. D.;
Arceo, R.;
Arteaga-Velázquez, J. C.;
Solares, H. A. Ayala;
Barber, A. S.;
Baughman, B. M.;
Bautista-Elivar, N.;
Belmont, E.;
BenZvi, S. Y.;
Berley, D.;
Rosales, M. Bonilla;
Braun, J.;
Caballero-Lopez, R. A.;
Caballero-Mora, K. S.;
Carramiñana, A.;
Castillo, M.;
Cotti, U.;
Cotzomi, J.;
de la Fuente, E.;
De León, C.;
DeYoung, T.;
Hernandez, R. Diaz;
Díaz-Vélez, J. C.;
Dingus, B. L.;
DuVernois, M. A.;
Ellsworth, R. W.;
Fernandez, A.;
Fiorino, D. W.;
Fraija, N.;
Galindo, A.;
Garfias, F.;
González, L. X.;
González, M. M.;
Goodman, J. A.;
Grabski, V.;
Gussert, M.;
Hampel-Arias, Z.;
Hui, C. M.;
Hüntemeyer, P.;
Imran, A.;
Iriarte, A.;
Karn, P.;
Kieda, D.;
Kunde, G. J.;
Lara, A.;
Lauer, R. J.;
Lee, W. H.;
Lennarz, D.;
Vargas, H. León;
Linares, E. C.;
Linnemann, J. T.;
Longo, M.;
Luna-GarcIa, R.;
Marinelli, A.;
Martinez, H.;
Martinez, O.;
Martínez-Castro, J.;
Matthews, J. A. J.;
Miranda-Romagnoli, P.;
Moreno, E.;
Mostafá, M.;
Nava, J.;
Nellen, L.;
Newbold, M.;
Noriega-Papaqui, R.;
Oceguera-Becerra, T.;
Patricelli, B.;
Pelayo, R.;
Pérez-Pérez, E. G.;
Pretz, J.;
Rivière, C.;
Rosa-González, D.;
Salazar, H.;
Salesa, F.;
Sanchez, F. E.;
Sandoval, A.;
Santos, E.;
Schneider, M.;
Silich, S.;
Sinnis, G.;
Smith, A. J.;
Sparks, K.;
Springer, R. W.;
Taboada, I.;
Toale, P. A.;
Tollefson, K.;
Torres, I.;
Ukwatta, T. N.;
Villaseñor, L.;
Weisgarber, T.;
Westerhoff, S.;
Wisher, I. G.;
Wood, J.;
Yodh, G. B.;
Younk, P. W.;
Zaborov, D.;
Zepeda, A.;
Zhou, H.
Submitted: 2013-09-30
The High-Altitude Water Cherenkov Gamma Ray Observatory (HAWC) is designed to
perform a synoptic survey of the TeV sky. The high energy coverage of the
experiment will enable studies of fundamental physics beyond the Standard
Model, and the large field of view of the detector will enable detailed studies
of cosmologically significant backgrounds and magnetic fields. We describe the
sensitivity of the full HAWC array to these phenomena in five contributions
shown at the 33rd International Cosmic Ray Conference in Rio de Janeiro, Brazil
(July 2013).
[15]
oai:arXiv.org:1310.0072 [pdf] - 726322
The HAWC Gamma-Ray Observatory: Observations of Cosmic Rays
HAWC Collaboration;
Abeysekara, A. U.;
Alfaro, R.;
Alvarez, C.;
Álvarez, J. D.;
Arceo, R.;
Arteaga-Velázquez, J. C.;
Solares, H. A. Ayala;
Barber, A. S.;
Baughman, B. M.;
Bautista-Elivar, N.;
Belmont, E.;
BenZvi, S. Y.;
Berley, D.;
Rosales, M. Bonilla;
Braun, J.;
Caballero-Lopez, R. A.;
Caballero-Mora, K. S.;
Carramiñana, A.;
Castillo, M.;
Cotti, U.;
Cotzomi, J.;
de la Fuente, E.;
De León, C.;
DeYoung, T.;
Hernandez, R. Diaz;
Díaz-Vélez, J. C.;
Dingus, B. L.;
DuVernois, M. A.;
Ellsworth, R. W.;
Fernandez, A.;
Fiorino, D. W.;
Fraija, N.;
Galindo, A.;
Garfias, F.;
González, L. X.;
González, M. M.;
Goodman, J. A.;
Grabski, V.;
Gussert, M.;
Hampel-Arias, Z.;
Hui, C. M.;
Hüntemeyer, P.;
Imran, A.;
Iriarte, A.;
Karn, P.;
Kieda, D.;
Kunde, G. J.;
Lara, A.;
Lauer, R. J.;
Lee, W. H.;
Lennarz, D.;
Vargas, H. León;
Linares, E. C.;
Linnemann, J. T.;
Longo, M.;
Luna-GarcIa, R.;
Marinelli, A.;
Martinez, H.;
Martinez, O.;
Martínez-Castro, J.;
Matthews, J. A. J.;
Miranda-Romagnoli, P.;
Moreno, E.;
Mostafá, M.;
Nava, J.;
Nellen, L.;
Newbold, M.;
Noriega-Papaqui, R.;
Oceguera-Becerra, T.;
Patricelli, B.;
Pelayo, R.;
Pérez-Pérez, E. G.;
Pretz, J.;
Rivière, C.;
Rosa-González, D.;
Salazar, H.;
Salesa, F.;
Sanchez, F. E.;
Sandoval, A.;
Santos, E.;
Schneider, M.;
Silich, S.;
Sinnis, G.;
Smith, A. J.;
Sparks, K.;
Springer, R. W.;
Taboada, I.;
Toale, P. A.;
Tollefson, K.;
Torres, I.;
Ukwatta, T. N.;
Villaseñor, L.;
Weisgarber, T.;
Westerhoff, S.;
Wisher, I. G.;
Wood, J.;
Yodh, G. B.;
Younk, P. W.;
Zaborov, D.;
Zepeda, A.;
Zhou, H.
Submitted: 2013-09-30
We describe measurements of GeV and TeV cosmic rays with the High-Altitude
Water Cherenkov Gamma-Ray Observatory, or HAWC. The measurements include the
observation of the shadow of the moon; the observation of small-scale and
large-scale angular clustering of the TeV cosmic rays; the prospects for
measurement of transient solar events with HAWC; and the observation of Forbush
decreases with the HAWC engineering array and HAWC-30.
[16]
oai:arXiv.org:1310.0071 [pdf] - 726321
The HAWC Gamma-Ray Observatory: Sensitivity to Steady and Transient
Sources of Gamma Rays
HAWC Collaboration;
Abeysekara, A. U.;
Alfaro, R.;
Alvarez, C.;
Álvarez, J. D.;
Arceo, R.;
Arteaga-Velázquez, J. C.;
Solares, H. A. Ayala;
Barber, A. S.;
Baughman, B. M.;
Bautista-Elivar, N.;
Belmont, E.;
BenZvi, S. Y.;
Berley, D.;
Rosales, M. Bonilla;
Braun, J.;
Caballero-Lopez, R. A.;
Caballero-Mora, K. S.;
Carramiñana, A.;
Castillo, M.;
Cotti, U.;
Cotzomi, J.;
de la Fuente, E.;
De León, C.;
DeYoung, T.;
Hernandez, R. Diaz;
Díaz-Vélez, J. C.;
Dingus, B. L.;
DuVernois, M. A.;
Ellsworth, R. W.;
Fernandez, A.;
Fiorino, D. W.;
Fraija, N.;
Galindo, A.;
Garfias, F.;
González, L. X.;
González, M. M.;
Goodman, J. A.;
Grabski, V.;
Gussert, M.;
Hampel-Arias, Z.;
Hui, C. M.;
Hüntemeyer, P.;
Imran, A.;
Iriarte, A.;
Karn, P.;
Kieda, D.;
Kunde, G. J.;
Lara, A.;
Lauer, R. J.;
Lee, W. H.;
Lennarz, D.;
Vargas, H. León;
Linares, E. C.;
Linnemann, J. T.;
Longo, M.;
Luna-GarcIa, R.;
Marinelli, A.;
Martinez, H.;
Martinez, O.;
Martínez-Castro, J.;
Matthews, J. A. J.;
Miranda-Romagnoli, P.;
Moreno, E.;
Mostafá, M.;
Nava, J.;
Nellen, L.;
Newbold, M.;
Noriega-Papaqui, R.;
Oceguera-Becerra, T.;
Patricelli, B.;
Pelayo, R.;
Pérez-Pérez, E. G.;
Pretz, J.;
Rivière, C.;
Rosa-González, D.;
Salazar, H.;
Salesa, F.;
Sanchez, F. E.;
Sandoval, A.;
Santos, E.;
Schneider, M.;
Silich, S.;
Sinnis, G.;
Smith, A. J.;
Sparks, K.;
Springer, R. W.;
Taboada, I.;
Toale, P. A.;
Tollefson, K.;
Torres, I.;
Ukwatta, T. N.;
Villaseñor, L.;
Weisgarber, T.;
Westerhoff, S.;
Wisher, I. G.;
Wood, J.;
Yodh, G. B.;
Younk, P. W.;
Zaborov, D.;
Zepeda, A.;
Zhou, H.
Submitted: 2013-09-30
The High-Altitude Water Cherenkov (HAWC) Gamma-Ray Observatory is designed to
record air showers produced by cosmic rays and gamma rays between 100 GeV and
100 TeV. Because of its large field of view and high livetime, HAWC is
well-suited to measure gamma rays from extended sources, diffuse emission, and
transient sources. We describe the sensitivity of HAWC to emission from the
extended Cygnus region as well as other types of galactic diffuse emission;
searches for flares from gamma-ray bursts and active galactic nuclei; and the
first measurement of the Crab Nebula with HAWC-30.
[17]
oai:arXiv.org:1306.2303 [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
ScottoLavina, L.;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali
del Gran Sasso (LNGS), aims to directly detect dark matter in the form of
Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off
xenon nuclei. This paper presents a study on the nuclear recoil background of
the experiment, taking into account neutron backgrounds from ($\alpha$,n) and
spontaneous fission reactions due to natural radioactivity in the detector and
shield materials, as well as muon-induced neutrons. Based on Monte Carlo
simulations and using measured radioactive contaminations of all detector
components, we predict the nuclear recoil backgrounds for the WIMP search
results published by the XENON100 experiment in 2011 and 2012,
0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively,
and conclude that they do not limit the sensitivity of the experiment.
[18]
oai:arXiv.org:1304.1427 [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Schuhmacher, H.;
Wiegel, B.
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter
detector installed underground at the Laboratori Nazionali del Gran Sasso
(LNGS), Italy are presented. Data from measurements with an external 241AmBe
neutron source are compared with a detailed Monte Carlo simulation which is
used to extract the energy dependent charge-yield Qy and relative scintillation
efficiency Leff. A very good level of absolute spectral matching is achieved in
both observable signal channels - scintillation S1 and ionization S2 - along
with agreement in the 2-dimensional particle discrimination space. The results
confirm the validity of the derived signal acceptance in earlier reported dark
matter searches of the XENON100 experiment.
[19]
oai:arXiv.org:1306.5800 [pdf] - 1453145
Sensitivity of the High Altitude Water Cherenkov Detector to Sources of
Multi-TeV Gamma Rays
Abeysekara, A. U.;
Alfaro, R.;
Alvarez, C.;
Álvarez, J. D.;
Arceo, R.;
Arteaga-Velázquez, J. C.;
Solares, H. A. Ayala;
Barber, A. S.;
Baughman, B. M.;
Bautista-Elivar, N.;
Belmont, E.;
BenZvi, S. Y.;
Berley, D.;
Rosales, M. Bonilla;
Braun, J.;
Caballero-Lopez, R. A.;
Carramiñana, A.;
Castillo, M.;
Cotti, U.;
Cotzomi, J.;
de la Fuente, E.;
De León, C.;
DeYoung, T.;
Hernandez, R. Diaz;
Diaz-Velez, J. C.;
Dingus, B. L.;
DuVernois, M. A.;
Ellsworth, R. W.;
Fernandez, A.;
Fiorino, D. W.;
Fraija, N.;
Galindo, A.;
Garcia-Luna, J. L.;
Garcia-Torales, G.;
Garfias, F.;
González, L. X.;
González, M. M.;
Goodman, J. A.;
Grabski, V.;
Gussert, M.;
Hampel-Arias, Z.;
Hui, C. M.;
Hüntemeyer, P.;
Imran, A.;
Iriarte, A.;
Karn, P.;
Kieda, D.;
Kunde, G. J.;
Lara, A.;
Lauer, R. J.;
Lee, W. H.;
Lennarz, D.;
Vargas, H. León;
Linares, E. C.;
Linnemann, J. T.;
Longo, M.;
Luna-García, R.;
Marinelli, A.;
Martinez, O.;
Martínez-Castro, J.;
Matthews, J. A. J.;
Miranda-Romagnoli, P.;
Moreno, E.;
Mostafá, M.;
Nava, J.;
Nellen, L.;
Newbold, M.;
Noriega-Papaqui, R.;
Oceguera-Becerra, T.;
Patricelli, B.;
Pelayo, R.;
Pérez-Pérez, E. G.;
Pretz, J.;
Rivière, C.;
Rosa-González, D.;
Salazar, H.;
Salesa, F.;
Sandoval, A.;
Santos, E.;
Schneider, M.;
Silich, S.;
Sinnis, G.;
Smith, A. J.;
Sparks, K.;
Springer, R. W.;
Taboada, I.;
Toale, P. A.;
Tollefson, K.;
Torres, I.;
Ukwatta, T. N.;
Villaseñor, L.;
Weisgarber, T.;
Westerhoff, S.;
Wisher, I. G.;
Wood, J.;
Yodh, G. B.;
Younk, P. W.;
Zaborov, D.;
Zepeda, A.;
Zhou, H.
Submitted: 2013-06-24
The High Altitude Water Cherenkov (HAWC) observatory is an array of large
water Cherenkov detectors sensitive to gamma rays and hadronic cosmic rays in
the energy band between 100 GeV and 100 TeV. The observatory will be used to
measure high-energy protons and cosmic rays via detection of the energetic
secondary particles reaching the ground when one of these particles interacts
in the atmosphere above the detector. HAWC is under construction at a site 4100
meters above sea level on the northern slope of the volcano Sierra Negra, which
is located in central Mexico at 19 degrees N latitude. It is scheduled for
completion in 2014. In this paper we estimate the sensitivity of the HAWC
instrument to point-like and extended sources of gamma rays. The source fluxes
are modeled using both unbroken power laws and power laws with exponential
cutoffs. HAWC, in one year, is sensitive to point sources with integral
power-law spectra as low as 5x10^-13 cm^-2 sec^-1 above 2 TeV (approximately 50
mCrab) over 5 sr of the sky. This is a conservative estimate based on simple
event parameters and is expected to improve as the data analysis techniques are
refined. We discuss known TeV sources and the scientific contributions that
HAWC can make to our understanding of particle acceleration in these sources.
[20]
oai:arXiv.org:1207.5988 [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kettling, H.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment,
operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during
2011 and 2012. XENON100 features an ultra-low electromagnetic background of
(5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of
interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded
no evidence for dark matter interactions. The two candidate events observed in
the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent
with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood
analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on
the spin-independent elastic WIMP-nucleon scattering cross section for WIMP
masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2
and 90% confidence level.
[21]
oai:arXiv.org:1101.3866 [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso
(LNGS), aims to directly detect dark matter in the form of Weakly Interacting
Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We
present a comprehensive study of the predicted electronic recoil background
coming from radioactive decays inside the detector and shield materials, and
intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a
detailed geometry together with the measured radioactivity of all detector
components, we predict an electronic recoil background in the WIMP-search
energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2
events/(kg-day-keV), consistent with the experiment's design goal. The
predicted background spectrum is in very good agreement with the data taken
during the commissioning of the detector, in Fall 2009.
[22]
oai:arXiv.org:1301.6620 [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days
of XENON100 data
XENON100 collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent
WIMP-nucleon cross section using recent data from the XENON100 experiment,
operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of
224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no
excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe
nuclei. This leads to the most stringent upper limits on WIMP-neutron cross
sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x
10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[23]
oai:arXiv.org:1211.0836 [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G. M.;
Budnik, R.;
Calloch, M. Le;
Cardoso, J. M.;
Chen, W. -T.;
Choi, B.;
Contreras, H.;
Cussonneau, J. -P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L.;
Grignon, C.;
Gross, E.;
Hampel, W.;
McKinsey, D. N.;
Kish, A.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Manzur, A.;
Undagoitia, T. Marrodán;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Patricio, J. V.;
Persiani, R.;
Plante, G.;
Priel, N.;
Ribeiro, A. C. C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso (LNGS) in Italy, was designed to search for evidence of dark matter
interactions inside a volume of liquid xenon using a dual-phase time projection
chamber. This paper describes the Slow Control System (SCS) of the experiment
with emphasis on the distributed architecture as well as on its modular and
expandable nature. The system software was designed according to the rules of
Object-Oriented Programming and coded in Java, thus promoting code reusability
and maximum flexibility during commissioning of the experiment. The SCS has
been continuously monitoring the XENON100 detector since mid 2008, remotely
recording hundreds of parameters on a few dozen instruments in real time, and
setting emergency alarms for the most important variables.
[24]
oai:arXiv.org:1209.3658 [pdf] - 673149
Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid
Xenon
Aprile, E.;
Budnik, R.;
Choi, B.;
Contreras, H. A.;
Giboni, K. -L.;
Goetzke, L. W.;
Koglin, J. E.;
Lang, R. F.;
Lim, K. E.;
Fernandez, A. J. Melgarejo;
Persiani, R.;
Plante, G.;
Rizzo, A.
Submitted: 2012-09-17
We have measured the energy dependence of the liquid xenon (LXe)
scintillation yield of electrons with energy between 2.1 and 120.2keV, using
the Compton coincidence technique. A LXe scintillation detector with a very
high light detection efficiency was irradiated with 137Cs {\gamma} rays and the
energy of the Compton-scattered {\gamma} rays was measured with a high-purity
germanium (HPGe) detector placed at different scattering angles. The excellent
energy resolution of the HPGe detector allows the selection of events with
Compton electrons of known energy in the LXe detector. We find that the
scintillation yield initially increases as the electron energy decreases from
120 keV to about 60keV but then decreases by about 30% from 60keV to 2keV. The
measured scintillation yield was also measured with conversion electrons from
the 32.1 keV and 9.4 keV transitions of the 83mKr isomer, used as an internal
calibration source. We find that the scintillation yield of the 32.1 keV
transition is compatible with that obtained from the Compton coincidence
measurement. On the other hand, the yield for the 9.4keV transition is much
higher than that measured for a Compton electron of the same energy. We
interpret the enhancement in the scintillation yield as due to the enhanced
recombination rate in the presence of Xe ions left from the 32.1 keV
transition, which precedes the 9.4 keV one by 220 ns, on average.
[25]
oai:arXiv.org:1208.5762 [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid
xenon detectors"
The XENON Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.
[26]
oai:arXiv.org:1207.5432 [pdf] - 1125033
Measurement of the Quantum Efficiency of Hamamatsu R8520
Photomultipliers at Liquid Xenon Temperature
Aprile, E.;
Beck, M.;
Bokeloh, K.;
Budnik, R.;
Choi, B.;
Contreras, H. A.;
Giboni, K. -L.;
Goetzke, L. W.;
Lang, R. F.;
Lim, K. E.;
Fernandez, A. J. Melgarejo;
Plante, G.;
Rizzo, A.;
Shagin, P.;
Weinheimer, C.
Submitted: 2012-07-23
Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to
liquid xenon are being used to efficiently detect the 178 nm scintillation
light in a variety of liquid xenon based particle detectors. Good knowledge of
the performance of these photomultipliers under cryogenic conditions is needed
to properly characterize these detectors. Here, we report on measurements of
the quantum efficiency of Hamamatsu R8520 photomultipliers, used in the XENON
Dark Matter Experiments. The quantum efficiency measurements at room
temperature agree with the values provided by Hamamatsu. At low temperatures,
between 160K and 170K, the quantum efficiency increases by $\sim5-11$% relative
to the room temperature values.
[27]
oai:arXiv.org:1107.2155 [pdf] - 474250
The XENON100 Dark Matter Experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. L.;
Kish, A.;
Lam, C. W.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Tziaferi, E.;
Wang, H.;
Yamashita, M.
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[28]
oai:arXiv.org:1104.3121 [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100
Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.
[29]
oai:arXiv.org:1103.0303 [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to
distinguish a dominant background from the expected feeble signals, based on
some measured discrimination parameter. We develop a statistical model for such
experiments using the Profile Likelihood ratio as a test statistic in a
frequentist approach. We take data from calibrations as control measurements
for signal and background, and the method allows the inclusion of data from
Monte Carlo simulations. Systematic detector uncertainties, such as
uncertainties in the energy scale, as well as astrophysical uncertainties, are
included in the model. The statistical model can be used to either set an
exclusion limit or to make a discovery claim, and the results are derived with
a proper treatment of statistical and systematic uncertainties. We apply the
model to the first data release of the XENON100 experiment, which allows to
extract additional information from the data, and place stronger limits on the
spin-independent elastic WIMP-nucleon scattering cross-section. In particular,
we derive a single limit, including all relevant systematic uncertainties, with
a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[30]
oai:arXiv.org:1104.2549 [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.
[31]
oai:arXiv.org:1104.2587 [pdf] - 669518
New Measurement of the Scintillation Efficiency of Low-Energy Nuclear
Recoils in Liquid Xenon
Submitted: 2011-04-13
Particle detectors that use liquid xenon (LXe) as detection medium are among
the leading technologies in the search for dark matter weakly interacting
massive particles (WIMPs). A key enabling element has been the low-energy
detection threshold for recoiling nuclei produced by the interaction of WIMPs
in LXe targets. In these detectors, the nuclear recoil energy scale is based on
the LXe scintillation signal and thus requires knowledge of the relative
scintillation efficiency of nuclear recoils, Leff. The uncertainty in Leff at
low energies is the largest systematic uncertainty in the reported results from
LXe WIMP searches at low masses. In the context of the XENON Dark Matter
project, a new LXe scintillation detector has been designed and built
specifically for the measurement of Leff at low energies, with an emphasis on
maximizing the scintillation light detection efficiency to obtain the lowest
possible energy threshold. We report new measurements of Leff at low energies
performed with this detector. Our results suggest a Leff which slowly decreases
with energy, from 0.144 +/- 0.009 at 15 keV down to 0.088 +0.014 -0.015 at 3
keV.
[32]
oai:arXiv.org:1005.0380 [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
The XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D. B.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Hugenberg, K.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weinheimer, C.
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62
kg of liquid xenon in an ultra-low background dual-phase time projection
chamber. In this letter, we present first dark matter results from the analysis
of 11.17 live days of non-blind data, acquired in October and November 2009. In
the selected fiducial target of 40 kg, and within the pre-defined signal
region, we observe no events and hence exclude spin-independent WIMP-nucleon
elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs
at 90% confidence level. Below 20 GeV/c^2, this result constrains the
interpretation of the CoGeNT and DAMA signals as being due to spin-independent,
elastic, light mass WIMP interactions.
[33]
oai:arXiv.org:0809.4780 [pdf] - 16818
New multisite observations of Delta Scuti stars V624 Tauri and HD 23194
Machado, L. Fox;
Michel, E.;
Chevreton, M.;
Alvarez, M.;
Li, Z. P.;
Belmonte, J. A.;
Fernandez, A.;
Parrao, L.;
Rabus, M.;
Lochard, J;
Hernandez, F. Perez;
Pena, J. H.;
Pau, S.
Submitted: 2008-09-27
The preliminary results of STEPHI 2006 campaign are reported.
[34]
oai:arXiv.org:0706.4083 [pdf] - 2627
Pulsational frequencies of the eclipsing delta-Scuti star HD 172189
Costa, J. E. S.;
Michel, E.;
Pena, J.;
Creevey, O.;
Li, Z. P.;
Chevreton, M.;
Belmonte, J. A.;
Alvarez, M.;
Machado, L. Fox;
Parrao, L.;
Hernendez, F. Perez;
Fernandez, A.;
Fremy, J. R.;
Pau, S.;
Alonso, R.
Submitted: 2007-06-27
The eclipsing delta-Scuti star HD 172189 is a probable member of the open
cluster IC 4756 and a promising candidate target for the CoRoT mission.
The detection of pulsation modes is the first step in the asteroseismological
study of the star. Further, the calculation of the orbital parameters of the
binary system allows us to make a dynamical determination of the mass of the
star, which works as an important constraint to test and calibrate the
asteroseismological models.
From a detailed frequency analysis of 210 hours of photometric data of HD
172189 obtained from the STEPHI XIII campaign we have identified six pulsation
frequencies with a confidence level of 99% and a seventh with a 65% confidence
level in the range between 100-300 uHz. In addiction, three eclipses were
observed during the campaign, allowing us to improve the determination of the
orbital period of the system.
[35]
oai:arXiv.org:0706.0576 [pdf] - 1899
Multi-site observations of Delta Scuti stars 7 Aql and 8 Aql (a new
Delta Scuti variable): The twelfth STEPHI campaign in 2003
Machado, L. Fox;
Michel, E.;
Hernandez, F. Perez;
Pena, J. H.;
Li, Z. P.;
Chevreton, M.;
Belmonte, J. A.;
Alvarez, M.;
Parrao, L.;
Dupret, M. -A.;
Pau, S.;
Fernandez, A.;
Michel, J. P.;
Michel, R.;
Pani, A.
Submitted: 2007-06-05
We present an analysis of the pulsation behaviour of the Delta Scuti stars 7
Aql (HD 174532) and 8 Aql (HD 174589) -- a new variable star -- observed in the
framework of STEPHI XII campaign during 2003 June--July. 183 hours of high
precision photometry were acquired by using four-channel photometers at three
sites on three continents during 21 days. The light curves and amplitude
spectra were obtained following a classical scheme of multi-channel photometry.
Observations in different filters were also obtained and analyzed. Six and
three frequencies have been unambiguously detected above a 99% confidence level
in the range 0.090 mHz--0.300 mHz and 0.100 mHz-- 0.145 mHz in 7 Aql and 8 Aql
respectively. A comparison of observed and theoretical frequencies shows that 7
Aql and 8 Aql may oscillate with p modes of low radial orders, typical among
Delta Scuti stars. In terms of radial oscillations the range of 8 Aql goes from
n=1 to n=3 while for 7 Aql the range spans from n=4 to n=7. Non-radial
oscillations have to be present in both stars as well. The expected range of
excited modes according to a non adiabatic analysis goes from n=1 to n=6 in
both stars.
[36]
oai:arXiv.org:astro-ph/9612204 [pdf] - 96232
The Performance of MEFOS, the ESO Multi-Object Fibre Spectrograph
Submitted: 1996-12-20
We are describing a new multi-fibre positioner, MEFOS, that was in general
use at the La Silla Observatory, and implemented at the prime focus of the ESO
3.6 m telescope. It is an arm positioner using 29 arms in a one degree field.
Each arm is equipped with an individual viewing system for accurate setting and
carries two spectroscopic fibres, one for the astronomical object and the other
one for the sky recording needed for sky subtraction. The spectral fibres
intercept 2.5 arcsec on the sky and run from the prime focus to the Cassegrain,
where the B&C spectrograph is located. After describing the observational
procedure, we present the first scientific results.