Normalized to: Fernandes, L.
[1]
oai:arXiv.org:1512.01763 [pdf] - 1351616
Comparison of 30 THz impulsive burst time development to microwaves,
H-alpha, EUV, and GOES soft X-rays
Miteva, R.;
Kaufmann, P.;
Cabezas, D. P.;
Cassiano, M. M.;
Fernandes, L. O. T.;
Freeland, S. L.;
Karlicky, M.;
Kerdraon, A.;
Kudaka, A. S.;
Luoni, M. L.;
Marcon, R.;
Raulin, J. -P.;
Trottet, G.;
White, S. M.
Submitted: 2015-12-06
The recent discovery of impulsive solar burst emission in the 30 THz band is
raising new interpretation challenges. One event associated with a GOES M2
class flare has been observed simultaneously in microwaves, H-alpha, EUV, and
soft X-ray bands. Although these new observations confirm some features found
in the two prior known events, they exhibit time profile structure
discrepancies between 30 THz, microwaves, and hard X-rays (as inferred from the
Neupert effect). These results suggest a more complex relationship between 30
THz emission and radiation produced at other wavelength ranges. The multiple
frequency emissions in the impulsive phase are likely to be produced at a
common flaring site lower in the chromosphere. The 30 THz burst emission may be
either part of a nonthermal radiation mechanism or due to the rapid thermal
response to a beam of high-energy particles bombarding the dense solar
atmosphere.
[2]
oai:arXiv.org:1505.06177 [pdf] - 1258925
Bright 30 THz Impulsive Solar Bursts
Kaufmann, P.;
White, S. M.;
Marcon, R.;
Kudaka, A. S.;
Cabezas, D. P.;
Cassiano, M. M.;
Francile, C.;
Fernandes, L. O. T.;
Ramirez, R. F. Hidalgo;
Luoni, M.;
Marun, A.;
Pereyra, P.;
de Souza, R. V.
Submitted: 2015-05-22
Impulsive 30 THz continuum bursts have been recently observed in solar
flares, utilizing small telescopes with a unique and relatively simple optical
setup concept. The most intense burst was observed together with a GOES X2
class event on October 27, 2014, also detected at two sub-THz frequencies,
RHESSI X-rays and SDO/HMI and EUV. It exhibits strikingly good correlation in
time and in space with white light flare emission. It is likely that this
association may prove to be very common. All three 30 THz events recently
observed exhibited intense fluxes in the range of 104 solar flux units,
considerably larger than those measured for the same events at microwave and
sub-mm wavelengths. The 30 THz burst emission might be part of the same
spectral burst component found at sub-THz frequencies. The 30 THz solar bursts
open a promising new window for the study of flares at their origin
[3]
oai:arXiv.org:1211.4508 [pdf] - 1157898
Ionization and scintillation response of high-pressure xenon gas to
alpha particles
NEXT Collaboration;
Álvarez, V.;
Borges, F. I. G. M.;
Cárcel, S.;
Cebrián, S.;
Cervera, A.;
Conde, C. A. N.;
Dafni, T.;
Díaz, J.;
Egorov, M.;
Esteve, R.;
Evtoukhovitch, P.;
Fernandes, L. M. P.;
Ferrario, P.;
Ferreira, A. L.;
Freitas, E. D. C.;
Gehman, V. M.;
Gil, A.;
Goldschmidt, A.;
Gómez, H.;
Gómez-Cadenas, J. J.;
González-Díaz, D.;
Gutiérrez, R. M.;
Hauptman, J.;
Morata, J. A. Hernando;
Herrera, D. C.;
Irastorza, I. G.;
Jinete, M. A.;
Labarga, L.;
Laing, A.;
Liubarsky, I.;
Lopes, J. A. M.;
Lorca, D.;
Losada, M.;
Luzón, G.;
Marí, A.;
Martín-Albo, J.;
Miller, T.;
Moiseenko, A.;
Monrabal, F.;
Monteiro, C. M. B.;
Mora, F. J.;
Moutinho, L. M.;
Vidal, J. Muñoz;
da Luz, H. Natal;
Navarro, G.;
Nebot-Guinot, M.;
Nygren, D.;
Oliveira, C. A. B.;
Palma, R.;
Pérez, J.;
Aparicio, J. L. Pérez;
Renner, J.;
Ripoll, L.;
Rodríguez, A.;
Rodríguez, J.;
Santos, F. P.;
Santos, J. M. F. dos;
Segui, L.;
Serra, L.;
Shuman, D.;
Simón, A.;
Sofka, C.;
Sorel, M.;
Toledo, J. F.;
Tomás, A.;
Torrent, J.;
Tsamalaidze, Z.;
Vázquez, D.;
Veloso, J. F. C. A.;
Webb, R.;
White, J. T;
Yahlali, N.
Submitted: 2012-11-19, last modified: 2013-05-21
High-pressure xenon gas is an attractive detection medium for a variety of
applications in fundamental and applied physics. In this paper we study the
ionization and scintillation detection properties of xenon gas at 10 bar
pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO
time projection chamber, the large scale prototype of the NEXT-100 neutrinoless
double beta decay experiment, in three different drift electric field
configurations. We measure the ionization electron drift velocity and
longitudinal diffusion, and compare our results to expectations based on
available electron scattering cross sections on pure xenon. In addition, two
types of measurements addressing the connection between the ionization and
scintillation yields are performed. On the one hand we observe, for the first
time in xenon gas, large event-by-event correlated fluctuations between the
ionization and scintillation signals, similar to that already observed in
liquid xenon. On the other hand, we study the field dependence of the average
scintillation and ionization yields. Both types of measurements may shed light
on the mechanism of electron-ion recombination in xenon gas for highly-ionizing
particles. Finally, by comparing the response of alpha particles and electrons
in NEXT-DEMO, we find no evidence for quenching of the primary scintillation
light produced by alpha particles in the xenon gas.
[4]
oai:arXiv.org:1104.3088 [pdf] - 661239
A search for light dark matter in XENON10 data
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.
[5]
oai:arXiv.org:1303.5894 [pdf] - 1165495
A bright impulsive solar burst detected at 30 THz
Kaufmann, P.;
White, S. M.;
Freeland, S. L.;
Marcon, R.;
Fernandes, L. O. T.;
Kudaka, A. S.;
de Souza, R. V.;
Aballay, J. L.;
Fernandez, G.;
Godoy, R.;
Marun, A.;
Valio, A.;
Raulin, J. -P.;
de Castro, C. G. Giménez
Submitted: 2013-03-23
Ground- and space-based observations of solar flares from radio wavelengths
to gamma-rays have produced considerable insights but raised several unsolved
controversies. The last unexplored wavelength frontier for solar flares is in
the range of submillimeter and infrared wavelengths. Here we report the
detection of an intense impulsive burst at 30 THz using a new imaging system.
The 30 THz emission exhibited remarkable time coincidence with peaks observed
at microwave, mm/submm, visible, EUV and hard X-ray wavelengths. The emission
location coincides with a very weak white-light feature, and is consistent with
heating below the temperature minimum in the atmosphere. However, there are
problems in attributing the heating to accelerated electrons. The peak 30 THz
flux is several times larger than the usual microwave peak near 9 GHz,
attributed to non-thermal electrons in the corona. The 30 THz emission could be
consistent with an optically thick spectrum increasing from low to high
frequencies. It might be part of the same spectral component found at sub-THz
frequencies whose nature remains mysterious. Further observations at these
wavelengths will provide a new window for flare studies.
[6]
oai:arXiv.org:1112.2908 [pdf] - 511766
Terahertz photometer to observe solar flares in continuum
Submitted: 2011-12-13
Solar observations at sub-THz frequencies detected a new flare spectral
component peaking in the THz range, simultaneously with the well known
microwaves component, bringing challenging constraints for interpretation.
Higher THz frequencies observations are needed to understand the nature of the
mechanisms occurring in flares. A THz photometer system was developed to
observe outside the terrestrial atmosphere on stratospheric balloons or
satellites, or at exceptionally transparent ground stations. The telescope was
designed to observe the whole solar disk detecting small relative changes in
input temperature caused by flares at localized positions. A Golay cell
detector is preceded by low-pass filters to suppress visible and near IR
radiation, a band-pass filter, and a chopper. A prototype was assembled to
demonstrate the new concept and the system performance. It can detect
temperature variations smaller than 1 K for data sampled at a rate of
10/second, smoothed for intervals larger than 4 seconds. For a 76 mm aperture,
this corresponds to small solar burst intensities at THz frequencies. A system
with 3 and 7 THz photometers is being built for solar flare observations on
board of stratospheric balloon missions.
[7]
oai:arXiv.org:1110.3013 [pdf] - 1084859
Sub-THz and H{\alpha} activity during the preflare and main phases of a
GOES class M2 event
Kaufmann, Pierre;
Marcon, Rogério;
de Castro, C. Guillermo Giménez;
White, Stephen M.;
Raulin, Jean-Pierre;
Correia, Emilia;
Fernandes, Luis Olavo;
de Souza, Rodney V.;
Godoy, Rodolfo;
Marun, Adolfo;
Pereyra, Pablo
Submitted: 2011-10-13
Radio and optical observations of the evolution of flare-associated phenomena
have shown an initial and rapid burst at 0.4 THz only followed subsequently by
a localized chromospheric heating producing an H{\alpha} brightening with later
heating of the whole active region. A major instability occurred several
minutes later producing one impulsive burst at microwaves only, associated with
an M2.0 GOES X-ray flare that exhibited the main H{\alpha} brightening at the
same site as the first flash. The possible association between long-enduring
time profiles at soft X-rays, microwaves, H{\alpha} and sub-THz wavelengths is
discussed. In the decay phase the H{\alpha} movie shows a disrupting magnetic
arch structure ejecting dark, presumably chromospheric, material upwards. The
time sequence of events suggests genuine interdependent and possibly
non-thermal instabilities triggering phenomena, with concurrent active region
plasma heating and material ejection.
[8]
oai:arXiv.org:0910.3698 [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
$m_{\chi}\gtrsim150$ GeV are disfavored.
[9]
oai:arXiv.org:1011.6439 [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Sorensen, P.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark
matter search data can be lowered to ~1 keV, by using only the ionization
signal. In other words, we make no requirement that a valid event contain a
primary scintillation signal. We therefore relinquish incident particle type
discrimination, which is based on the ratio of ionization to scintillation in
liquid xenon. This method compromises the detector's ability to precisely
determine the z coordinate of a particle interaction. However, we show for the
first time that it is possible to discriminate bulk events from surface events
based solely on the ionization signal.
[10]
oai:arXiv.org:1009.2719 [pdf] - 1034959
Primary and secondary scintillation measurements in a xenon Gas
Proportional Scintillation Counter
Submitted: 2010-09-14, last modified: 2010-09-15
NEXT is a new experiment to search for neutrinoless double beta decay using a
100 kg radio-pure high-pressure gaseous xenon TPC. The detector requires
excellent energy resolution, which can be achieved in a Xe TPC with
electroluminescence readout. Hamamatsu R8520-06SEL photomultipliers are good
candidates for the scintillation readout. The performance of this
photomultiplier, used as VUV photosensor in a gas proportional scintillation
counter, was investigated. Initial results for the detection of primary and
secondary scintillation produced as a result of the interaction of 5.9 keV
X-rays in gaseous xenon, at room temperature and at pressures up to 3 bar, are
presented. An energy resolution of 8.0% was obtained for secondary
scintillation produced by 5.9 keV X-rays. No significant variation of the
primary scintillation was observed for different pressures (1, 2 and 3 bar) and
for electric fields up to 0.8 V cm-1 torr-1 in the drift region, demonstrating
negligible recombination luminescence. A primary scintillation yield of 81 \pm
7 photons was obtained for 5.9 keV X-rays, corresponding to a mean energy of 72
\pm 6 eV to produce a primary scintillation photon in xenon.
[11]
oai:arXiv.org:1001.2834 [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Aprile, E.;
Angle, J.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Orlandi, D.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Tatananni, E.;
Winant, C.;
Yamashita, M.
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously.
[12]
oai:arXiv.org:0807.0459 [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear
recoils
Sorensen, P.;
Manzur, A.;
Dahl, C. E.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It
is a dual phase (liquid/gas) xenon time-projection chamber with 3D position
imaging. Particle interactions generate a primary scintillation signal (S1) and
ionization signal (S2), which are both functions of the deposited recoil energy
and the incident particle type. We present a new precision measurement of the
relative scintillation yield \leff and the absolute ionization yield Q_y, for
nuclear recoils in xenon. A dark matter particle is expected to deposit energy
by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for
establishing the energy threshold of the experiment; this in turn determines
the sensitivity to particle dark matter. Our \leff measurement is in agreement
with recent theoretical predictions above 15 keV nuclear recoil energy, and the
energy threshold of the measurement is 4 keV. A knowledge of the ionization
yield \Qy is necessary to establish the trigger threshold of the experiment.
The ionization yield \Qy is measured in two ways, both in agreement with
previous measurements and with a factor of 10 lower energy threshold.
[13]
oai:arXiv.org:0805.2939 [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10
experiment
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive
particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter
in our Universe. We report new results for spin-dependent WIMP-nucleon
interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the
Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a
WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously
unexplored regions in the theoretically allowed parameter space for
neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range
of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its
density and distribution in the galactic halo.
[14]
oai:arXiv.org:0706.0039 [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso
National Laboratory
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.
[15]
oai:arXiv.org:astro-ph/0609714 [pdf] - 85306
3D Position Sensitive XeTPC for Dark Matter Search
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Coelho, L.;
Dahl, E.;
DeViveiros, L.;
Ferella, A.;
Fernandes, L.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. -L.;
Gomez, R.;
Hasty, R.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santos, J.;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Winant, C.;
Yamashita, M.
Submitted: 2006-09-26
The technique to realize 3D position sensitivity in a two-phase xenon time
projection chamber (XeTPC) for dark matter search is described. Results from a
prototype detector (XENON3) are presented.