Normalized to: Ferlet, M.
[1]
oai:arXiv.org:1306.1778 [pdf] - 862347
Flux Calibration of Broadband Far Infrared and Submillimetre Photometric
Instruments: Theory and Application to Herschel-SPIRE
Griffin, M. J.;
North, C. E.;
Schulz, B.;
Amaral-Rogers, A.;
Bendo, G.;
Bock, J.;
Conversi, L.;
Conley, A.;
Dowell, C. D.;
Ferlet, M.;
Glenn, J.;
Lim, T.;
Pearson, C.;
Pohlen, M.;
Sibthorpe, B.;
Spencer, L.;
Swinyard, B.;
Valtchanov, I.
Submitted: 2013-06-07, last modified: 2014-08-11
Photometric instruments operating at far infrared to millimetre wavelengths
often have broad spectral passbands (central wavelength/bandwidth ~ 3 or less),
especially those operating in space. A broad passband can result in significant
variation of the beam profile and aperture efficiency across the passband,
effects which thus far have not generally been taken into account in the flux
calibration of such instruments. With absolute calibration uncertainties
associated with the brightness of primary calibration standards now in the
region of 5% or less, variation of the beam properties across the passband can
be a significant contributor to the overall calibration accuracy for extended
emission. We present a calibration framework which takes such variations into
account for both antenna-coupled and absorber-coupled focal plane
architectures. The scheme covers point source and extended source cases, and
also the intermediate case of a semi-extended source profile. We apply the new
method to the Herschel-SPIRE space-borne photometer.
[2]
oai:arXiv.org:1403.1107 [pdf] - 1208191
Calibration of the Herschel SPIRE Fourier Transform Spectrometer
Swinyard, B. M.;
Polehampton, E. T.;
Hopwood, R.;
Valtchanov, I.;
Lu, N.;
Fulton, T.;
Benielli, D.;
Imhof, P.;
Marchili, N.;
Baluteau, J. -P.;
Bendo, G. J.;
Ferlet, M.;
Griffin, M. J.;
Lim, T. L.;
Makiwa, G.;
Naylor, D. A.;
Orton, G. S.;
Papageorgiou, A.;
Pearson, C. P.;
Schulz, B.;
Sidher, S. D.;
Spencer, L. D.;
van der Wiel, M. H. D.;
Wu, R.
Submitted: 2014-03-05
The Herschel SPIRE instrument consists of an imaging photometric camera and
an imaging Fourier Transform Spectrometer (FTS), both operating over a
frequency range of 450-1550 GHz. In this paper, we briefly review the FTS
design, operation, and data reduction, and describe in detail the approach
taken to relative calibration (removal of instrument signatures) and absolute
calibration against standard astronomical sources. The calibration scheme
assumes a spatially extended source and uses the Herschel telescope as primary
calibrator. Conversion from extended to point-source calibration is carried out
using observations of the planet Uranus. The model of the telescope emission is
shown to be accurate to within 6% and repeatable to better than 0.06% and, by
comparison with models of Mars and Neptune, the Uranus model is shown to be
accurate to within 3%. Multiple observations of a number of point-like sources
show that the repeatability of the calibration is better than 1%, if the
effects of the satellite absolute pointing error (APE) are corrected. The
satellite APE leads to a decrement in the derived flux, which can be up to ~10%
(1 sigma) at the high-frequency end of the SPIRE range in the first part of the
mission, and ~4% after Herschel operational day 1011. The lower frequency range
of the SPIRE band is unaffected by this pointing error due to the larger beam
size. Overall, for well-pointed, point-like sources, the absolute flux
calibration is better than 6%, and for extended sources where mapping is
required it is better than 7%.
[3]
oai:arXiv.org:1306.5780 [pdf] - 1172267
Observing Extended Sources with the \Herschel SPIRE Fourier Transform
Spectrometer
Wu, Ronin;
Polehampton, Edward T.;
Etxaluze, Mireya;
Makiwa, Gibion;
Naylor, David A.;
Salji, Carl;
Swinyard, Bruce M.;
Ferlet, Marc;
van der Wiel, Matthijs H. D.;
Smith, Anthony J.;
Fulton, Trevor;
Griffin, Matt J.;
Baluteau, Jean-Paul;
Benielli, Dominique;
Glenn, Jason;
Hopwood, Rosalind;
Imhof, Peter;
Lim, Tanya;
Lu, Nanyao;
Panuzzo, Pasquale;
Pearson, Chris;
Sidher, Sunil;
Valtchanov, Ivan
Submitted: 2013-06-24
The Spectral and Photometric Imaging Receiver (SPIRE) on the European Space
Agency's Herschel Space Observatory utilizes a pioneering design for its
imaging spectrometer in the form of a Fourier Transform Spectrometer (FTS). The
standard FTS data reduction and calibration schemes are aimed at objects with
either a spatial extent much larger than the beam size or a source that can be
approximated as a point source within the beam. However, when sources are of
intermediate spatial extent, neither of these calibrations schemes is
appropriate and both the spatial response of the instrument and the source's
light profile must be taken into account and the coupling between them
explicitly derived. To that end, we derive the necessary corrections using an
observed spectrum of a fully extended source with the beam profile and the
source's light profile taken into account. We apply the derived correction to
several observations of planets and compare the corrected spectra with their
spectral models to study the beam coupling efficiency of the instrument in the
case of partially extended sources. We find that we can apply these correction
factors for sources with angular sizes up to \theta_{D} ~ 17". We demonstrate
how the angular size of an extended source can be estimated using the
difference between the sub-spectra observed at the overlap bandwidth of the two
frequency channels in the spectrometer, at 959<\nu<989 GHz. Using this
technique on an observation of Saturn, we estimate a size of 17.2", which is 3%
larger than its true size on the day of observation. Finally, we show the
results of the correction applied on observations of a nearby galaxy, M82, and
the compact core of a Galactic molecular cloud, Sgr B2.
[4]
oai:arXiv.org:1005.5073 [pdf] - 1032794
In-flight calibration of the Herschel-SPIRE instrument
Swinyard, B. M.;
Ade, P.;
Baluteau, J-P.;
Aussel, H.;
Barlow, M. J.;
Bendo, G. J.;
Benielli, D.;
Bock, J.;
Brisbin, D.;
Conley, A.;
Conversi, L.;
Dowell, A.;
Dowell, D.;
Ferlet, M.;
Fulton, T.;
Glenn, J.;
Glauser, A.;
Griffin, D.;
Griffin, M.;
Guest, S.;
Imhof, P.;
Isaak, K.;
Jones, S.;
King, K.;
Leeks, S.;
Levenson, L.;
Lim, T. L.;
Lu, N.;
Makiwa, G.;
Naylor, D.;
Nguyen, H.;
Oliver, S.;
Panuzzo, P.;
Papageorgiou, A.;
Pearson, C.;
Pohlen, M.;
Polehampton, E.;
Pouliquen, D.;
Rigopoulou, D.;
Ronayette, S.;
Roussel, H.;
Rykala, A.;
Savini, G.;
Schulz, B.;
Schwartz, A.;
Shupe, D.;
Sibthorpe, B.;
Sidher, S.;
Smith, A. J.;
Spencer, L.;
Trichas, M.;
Triou, H.;
Valtchanov, I.;
Wesson, R.;
Woodcraft, A.;
Xu, C. K.;
Zemcov, M.;
Zhang, L.
Submitted: 2010-05-27
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space
Observatory's submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 {\mu}m, and an imaging Fourier
transform spectrometer (FTS) covering 194-671 {\mu}m (447-1550 GHz). In this
paper we describe the initial approach taken to the absolute calibration of the
SPIRE instrument using a combination of the emission from the Herschel
telescope itself and the modelled continuum emission from solar system objects
and other astronomical targets. We present the photometric, spectroscopic and
spatial accuracy that is obtainable in data processed through the "standard"
pipelines. The overall photometric accuracy at this stage of the mission is
estimated as 15% for the photometer and between 15 and 50% for the
spectrometer. However, there remain issues with the photometric accuracy of the
spectra of low flux sources in the longest wavelength part of the SPIRE
spectrometer band. The spectrometer wavelength accuracy is determined to be
better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is
found to be 2 arcsec when the latest calibration data are used. The photometric
calibration of the SPIRE instrument is currently determined by a combination of
uncertainties in the model spectra of the astronomical standards and the data
processing methods employed for map and spectrum calibration. Improvements in
processing techniques and a better understanding of the instrument performance
will lead to the final calibration accuracy of SPIRE being determined only by
uncertainties in the models of astronomical standards.
[5]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.
[6]
oai:arXiv.org:0809.0242 [pdf] - 15846
Using SPICA Space Telescope to characterize Exoplanets
Goicoechea, J. R.;
Swinyard, B.;
Tinetti, G.;
Nakagawa, T.;
Enya, K.;
Tamura, M.;
Ferlet, M.;
Isaak, K. G.;
Wyatt, M.;
Aylward, A. D.;
Barlow, M.;
Beaulieu, J. P.;
Boccaletti, A.;
Cernicharo, J.;
Cho, J.;
Claudi, R.;
Jones, H.;
Lammer, H.;
Leger, A.;
Martín-Pintado, J.;
Miller, S.;
Najarro, F.;
Pinfield, D.;
Schneider, J.;
Selsis, F.;
Stam, D. M.;
Tennyson, J.;
Viti, S.;
White, G.
Submitted: 2008-09-01, last modified: 2008-09-15
We present the 3.5m SPICA space telescope, a proposed Japanese-led JAXA-ESA
mission scheduled for launch around 2017. The actively cooled (<5 K), single
aperture telescope and monolithic mirror will operate from ~3.5 to ~210 um and
will provide superb sensitivity in the mid- and far-IR spectral domain (better
than JWST at lambda > 18 um). SPICA is one of the few space missions selected
to go to the next stage of ESA's Cosmic Vision 2015-2025 selection process. In
this White Paper we present the main specifications of the three instruments
currently baselined for SPICA: a mid-infrared (MIR) coronagraph (~3.5 to ~27
um) with photometric and spectral capabilities (R~200), a MIR wide-field camera
and high resolution spectrometer (R~30,000), and a far-infrared (FIR ~30 to
~210 um) imaging spectrometer - SAFARI - led by a European consortium. We
discuss their capabilities in the context of MIR direct observations of
exo-planets (EPs) and multiband photometry/high resolution spectroscopy
observations of transiting exo-planets. We conclude that SPICA will be able to
characterize the atmospheres of transiting exo-planets down to the super-Earth
size previously detected by ground- or space-based observatories. It will also
directly detect and characterize Jupiter/Neptune-size planets orbiting at
larger separation from their parent star (>5-10 AU), by performing quantitative
atmospheric spectroscopy and studying proto-planetary and debris disks. In
addition, SPICA will be a scientific and technological precursor for future,
more ambitious, IR space missions for exo-planet direct detection as it will,
for example, quantify the prevalence exo-zodiacal clouds in planetary systems
and test coronographic techniques, cryogenic systems and lightweight, high
quality telescopes. (abridged)