Normalized to: Ferenc, M.
[1]
oai:arXiv.org:1901.02139 [pdf] - 1815178
Helium Migration through Photomultiplier Tubes -- The Probable Cause of
the DAMA Seasonal Variation Effect
Submitted: 2019-01-07, last modified: 2019-01-14
The interpretation of the DAMA seasonal variation pattern as a Dark Matter
(DM) effect rests on the assumption that all sources of variable background
have been excluded from the measurement. We have identified an overlooked
background that mimics the DM signature -- a large, patently existing effect
that has nothing to do with detection within the scintillators. This process
takes place exclusively within the individual photomultiplier tubes (PMTs),
with two familiar actors (thermionic electrons and helium atoms), two familiar
processes (helium penetration of glass and ion afterpulsing), and a simple
storyline: (a) After defeating the insulation of the DAMA detector, helium
atoms from the variable local environment penetrate the PMT vacua; (b)
Thermionic electrons from the PMT photocathode ionize helium atoms; (c)
Secondary electrons from each helium ion impact in the photocathode form an
afterpulse, and thus effectively boost and extend the waveform. We demonstrate
that the accidental coincidences of such inflated dark noise waveforms,
originating from any pair of PMTs, mimic scintillation events at a rate of
$\approx$ 1 cpd/kg/keV, which is consistent with DAMA result. The reported
seasonal variation of $\sim$ 1% thus implicates an equivalent variation of
helium concentration in the local environment. We predict that the DAMA
detector with a modified readout logic -- blinded for the DM scintillation
events \textendash will measure the same, helium -- driven seasonal variation
pattern as the original detector.
[2]
oai:arXiv.org:1810.00280 [pdf] - 1758783
ABALONE Photosensors for the IceCube Experiment
Submitted: 2018-09-29
The ABALONE Photosensor Technology (U.S. Pat. 9064678) is a modern, scalable
technology specifically invented for cost effective mass production,
robustness, and high performance. We present the performance of advanced fused
silica ABALONE Photosensors, developed specifically for the potential extension
of the Ice Cube neutrino experiment, and stress tested for 120 days. The
resulting performance makes a significant difference: intrinsic gain in the
high 100 million range, total afterpulsing rate of only 0.005 ions per
photoelectron, subnanosecond timing resolution, single photon sensitivity, and
unique radiopurity and UV sensitivity, thanks to the fused silica components,
at no additional cost to the assembly process.
[3]
oai:arXiv.org:1703.04546 [pdf] - 1581917
The Novel ABALONE Photosensor Technology: 4-Year Long Tests of Vacuum
Integrity, Internal Pumping and Afterpulsing
Submitted: 2017-03-13, last modified: 2017-05-26
The ABALONE Photosensor Technology (U.S. Patent 9064678 2015) has the
capability of supplanting the expensive 80 year old Photomultiplier Tube (PMT)
manufacture by providing a modern and cost effective alternative product. An
ABALONE Photosensor comprises only three monolithic glass components, sealed
together by our new thin film adhesive. In 2013, we left one of the early
ABALONE Photosensor prototypes intact for continuous stress testing, and here
we report its long term vacuum integrity. The exceptionally low ion
afterpulsing rate (approximately two orders of magnitude lower than in PMTs)
has been constantly improving. We explain the physical and technological
reasons for this achievement. Due to the cost-effectiveness and the specific
combination of features, including low level of radioactivity, integration into
large-area panels, and robustness, this technology can open new horizons in the
fields of fundamental physics, functional medical imaging, and nuclear
security.