Normalized to: Feng, M.
[1]
oai:arXiv.org:1912.03466 [pdf] - 2104657
The Possible Electromagnetic Counterparts of the First High-Probability
NSBH Merger LIGO/Virgo S190814bv
Submitted: 2019-12-07, last modified: 2020-05-30
LIGO/Virgo S190814bv is the first high-probability neutron star - black hole
(NSBH) merger candidate, whose gravitational waves (GWs) triggered LIGO/Virgo
detectors at 21:10:39.012957 UT, 14 August 2019. It has a probability $>99\%$
of being an NSBH merger, with a low false alarm rate (FAR) of 1 per 1.559e+25
years. For an NSBH merger, electromagnetic counterparts (especially short
gamma-ray bursts (GRBs)) are generally expected. However, no electromagnetic
counterpart has been found in the extensive follow-up observing campaign. In
the present work, we propose a novel explanation to this null result. In our
scenario, LIGO/Virgo S190814bv is just a GW mirror image of the real NSBH
merger which should be detected before 14 September 2015, but at that time we
had no ability to detect its GW signals. The electromagnetic counterparts
associated with the real NSBH merger should be found in the archive data before
14 September 2015. In this work, we indeed find 9 short GRBs as the possible
electromagnetic counterparts.
[2]
oai:arXiv.org:1805.07605 [pdf] - 1690419
In-Orbit Instrument Performance Study and Calibration for POLAR
Polarization Measurements
Li, Zhengheng;
Kole, Merlin;
Sun, Jianchao;
Song, Liming;
Produit, Nicolas;
Wu, Bobing;
Bao, Tianwei;
Bernasconi, Tancredi;
Cadoux, Franck;
Dong, Yongwei;
Feng, Minzi;
Gauvin, Neal;
Hajdas, Wojtek;
Li, Hancheng;
Li, Lu;
Liu, Xin;
Marcinkowski, Radoslaw;
Pohl, Martin;
Rybka, Dominik K.;
Shi, Haoli;
Szabelski, Jacek;
Tymieniecka, Teresa;
Wang, Ruijie;
Wang, Yuanhao;
Wen, Xing;
Wu, Xin;
Xiong, Shaolin;
Zwolinska, Anna;
Zhang, Li;
Zhang, Laiyu;
Zhang, Shuangnan;
Zhang, Yongjie;
Zhao, Yi
Submitted: 2018-05-19, last modified: 2018-05-28
POLAR is a compact space-borne detector designed to perform reliable
measurements of the polarization for transient sources like Gamma-Ray Bursts in
the energy range 50-500keV. The instrument works based on the Compton
Scattering principle with the plastic scintillators as the main detection
material along with the multi-anode photomultiplier tube. POLAR has been
launched successfully onboard the Chinese space laboratory TG-2 on 15th
September, 2016. In order to reliably reconstruct the polarization information
a highly detailed understanding of the instrument is required for both data
analysis and Monte Carlo studies. For this purpose a full study of the in-orbit
performance was performed in order to obtain the instrument calibration
parameters such as noise, pedestal, gain nonlinearity of the electronics,
threshold, crosstalk and gain, as well as the effect of temperature on the
above parameters. Furthermore the relationship between gain and high voltage of
the multi-anode photomultiplier tube has been studied and the errors on all
measurement values are presented. Finally the typical systematic error on
polarization measurements of Gamma-Ray Bursts due to the measurement error of
the calibration parameters are estimated using Monte Carlo simulations.
[3]
oai:arXiv.org:1802.09271 [pdf] - 1686763
A Low-latency Pipeline for GRB Light Curve and Spectrum using Fermi/GBM
Near Real-time Data
Zhao, Yi;
Zhang, Binbin;
Xiong, Shaolin;
Long, Xi;
Zhang, Qiang;
Song, Liming;
Sun, Jianchao;
Wang, Yuanhao;
Li, Hancheng;
Bu, Qingcui;
Feng, Minzi;
Li, Zhengheng;
Wen, Xing;
Wu, Bobing;
Zhang, Laiyu;
Zhang, Yongjie;
Zhang, Shuangnan;
Shao, Jianxiong
Submitted: 2018-02-26
Rapid response and short time latency are very important for Time Domain
Astronomy, such as the observations of Gamma-ray Bursts (GRBs) and
electromagnetic (EM) counterparts of gravitational waves (GWs). Based on the
near real-time Fermi/GBM data, we developed a low-latency pipeline to
automatically calculate the temporal and spectral properties of GRBs. With this
pipeline, some important parameters can be obtained, such as T90 and fluence,
within ~20 minutes after the GRB trigger. For ~90% GRBs, T90 and fluence are
consistent with the GBM catalog results within 2 sigma errors. This pipeline
has been used by the Gamma-ray Bursts Polarimeter (POLAR) and the Insight Hard
X-ray Modulation Telescope (Insight-HXMT) to follow up the bursts of interest.
For GRB 170817A, the first EM counterpart of GW events detected by Fermi/GBM
and INTEGRAL/SPI-ACS, the pipeline gave T90 and spectral information in 21
minutes after the GBM trigger, providing important information for POLAR and
Insight-HXMT observations.
[4]
oai:arXiv.org:1708.00664 [pdf] - 1586674
Instrument Performance and Simulation Verification of the POLAR Detector
Kole, M.;
Li, Z. H.;
Produit, N.;
Tymieniecka, T.;
Zhang, J.;
Zwolinska, A.;
Bao, T. W.;
Bernasconi, T.;
Cadoux, F.;
Feng, M. Z.;
Gauvin, N.;
Hajdas, W.;
Kong, S. W.;
Li, H. C.;
Li, L.;
Liu, X.;
Marcinkowski, R.;
Orsi, S.;
Pohl, M.;
Rybka, D.;
Sun, J. C.;
Song, L. M.;
Szabelski, J.;
Wang, R. J.;
Wang, Y. H.;
Wen, X.;
Wu, B. B.;
Wu, X.;
Xiao, H. L.;
Zhang, L.;
Zhang, L. Y.;
Zhang, S. N.;
Zhang, X. F.;
Zhang, Y. J.;
Zhao, Y.
Submitted: 2017-08-02
POLAR is a new satellite-born detector aiming to measure the polarization of
an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The
instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of
September 2016, is designed to measure the polarization of the hard X-ray flux
by measuring the distribution of the azimuthal scattering angles of the
incoming photons. A detailed understanding of the polarimeter and specifically
of the systematic effects induced by the instrument's non-uniformity are
required for this purpose. In order to study the instrument's response to
polarization, POLAR underwent a beam test at the European Synchrotron Radiation
Facility in France. In this paper both the beam test and the instrument
performance will be described. This is followed by an overview of the Monte
Carlo simulation tools developed for the instrument. Finally a comparison of
the measured and simulated instrument performance will be provided and the
instrument response to polarization will be presented.