sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Feldman, William C.

Normalized to: Feldman, W.

10 article(s) in total. 27 co-authors, from 1 to 5 common article(s). Median position in authors list is 4,5.

[1]  oai:arXiv.org:1904.09036  [pdf] - 1943270
New and Extended Data Processing of Mars Odyssey Neutron Spectrometer Data
Comments:
Submitted: 2019-04-18, last modified: 2019-08-14
The Los Alamos National Laboratory designed and built Mars Odyssey Neutron Spectrometer (MONS) has been in excellent health operating from February 2002 to the present. MONS measures the neutron leakage albedo from galactic cosmic ray bombardment of Mars. These signals can indicate the presence of near-surface water deposits on Mars, and can also be used to study properties of the seasonal polar CO$_2$ ice caps. This work outlines a new analysis of the MONS data that results in new and extended time-series maps of MONS thermal and epithermal neutron data. The new data are compared to previous publications on the MONS instrument. We then present preliminary results studying the inter-annual variability in the polar regions of Mars based on 8 Mars-Years of MONS data from the new dataset.
[2]  oai:arXiv.org:1901.02967  [pdf] - 1812991
Elpasolite Planetary Ice and Composition Spectrometer (EPICS): A Low-Resource Combined Gamma-Ray and Neutron Spectrometer for Planetary Science
Comments: Submitted to 2019 IEEE Nuclear Science Symposium Conference Proceedings
Submitted: 2019-01-09
Neutron and gamma-ray spectroscopy (NGRS) is a well established technique for studying the geochemical composition and volatile abundance relevant to planetary structure and evolution of planetary bodies. Previous NGRS instruments have used separate gamma-ray and neutron spectrometers. The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) instrument is an innovative and fully integrated NGRS with low resource requirements. EPICS utilizes elpasolite scintillator read out by silicon photomultipliers to combine the gamma-ray and neutron spectrometer into a single instrument, leading to a significant reduction in instrument size, weight, and power. An overview and motivation for the EPICS instrument, current status of the EPICS development, and a discussion of the expected sensitivity and performance are presented.
[3]  oai:arXiv.org:1810.06483  [pdf] - 1812905
Benchmarking Geant4 for Simulating Galactic Cosmic Ray Interactions Within Planetary Bodies
Comments:
Submitted: 2018-10-15
Galactic cosmic rays undergo complex nuclear interactions with nuclei within planetary bodies that have little to no atmosphere. Radiation transport simulations are a key tool used in understanding the neutron and gamma-ray albedo coming from these interactions and tracing these signals back to geochemical composition of the target. We study the validity of the code Geant4 for simulating such interactions by comparing simulation results to data from the Apollo 17 Lunar Neutron Probe Experiment. Different assumptions regarding the physics are explored to demonstrate how these impact the Geant4 simulation results. In general, all of the Geant4 results over-predict the data, however, certain physics lists perform better than others. In addition, we show that results from the radiation transport code MCNP6 are similar to those obtained using Geant4.
[4]  oai:arXiv.org:1705.05556  [pdf] - 1597036
Driven by Excess? Climatic Implications of New Global Mapping of Near-Surface Water-Equivalent Hydrogen on Mars
Comments: 89 pages, 33 figures, revision submitted to Icarus
Submitted: 2017-05-16, last modified: 2017-08-25
We present improved Mars Odyssey Neutron Spectrometer (MONS) maps of near-surface Water-Equivalent Hydrogen (WEH) on Mars that have intriguing implications for the global distribution of "excess" ice, which occurs when the mass fraction of water ice exceeds the threshold amount needed to saturate the pore volume in normal soils. We have refined the crossover technique of Feldman et al. (2011) by using spatial deconvolution and Gaussian weighting to create the first globally self-consistent map of WEH. At low latitudes, our new maps indicate that WEH exceeds 15% in several near-equatorial regions, such as Arabia Terra, which has important implications for the types of hydrated minerals present at low latitudes. At high latitudes, we demonstrate that the disparate MONS and Phoenix Robotic Arm (RA) observations of near surface WEH can be reconciled by a three-layer model incorporating dry soil over fully saturated pore ice over pure excess ice: such a three-layer model can also potentially explain the strong anticorrelation of subsurface ice content and ice table depth observed at high latitudes. At moderate latitudes, we show that the distribution of recently formed impact craters is also consistent with our latest MONS results, as both the shallowest ice-exposing crater and deepest non-ice-exposing crater at each impact site are in good agreement with our predictions of near-surface WEH. Overall, we find that our new mapping is consistent with the widespread presence at mid-to-high Martian latitudes of recently deposited shallow excess ice reservoirs that are not yet in equilibrium with the atmosphere.
[5]  oai:arXiv.org:1708.00518  [pdf] - 1586653
Equatorial locations of water on Mars: Improved resolution maps based on Mars Odyssey Neutron Spectrometer data
Comments: Accepted for publication in Icarus, 16 pages, 12 figures
Submitted: 2017-08-01
We present a map of the near subsurface hydrogen distribution on Mars, based on epithermal neutron data from the Mars Odyssey Neutron Spectrometer. The map's spatial resolution is approximately improved two-fold via a new form of the pixon image reconstruction technique. We discover hydrogen-rich mineralogy far from the poles, including ~10 wt. % water equivalent hydrogen (WEH) on the flanks of the Tharsis Montes and greater than 40 wt. % WEH at the Medusae Fossae Formation (MFF). The high WEH abundance at the MFF implies the presence of bulk water ice. This supports the hypothesis of recent periods of high orbital obliquity during which water ice was stable on the surface. We find the young undivided channel system material in southern Elysium Planitia to be distinct from its surroundings and exceptionally dry; there is no evidence of hydration at the location in Elysium Planitia suggested to contain a buried water ice sea. Finally, we find that the sites of recurring slope lineae (RSL) do not correlate with subsurface hydration. This implies that RSL are not fed by large, near-subsurface aquifers, but are instead the result of either small (less than 120 km diameter) aquifers, deliquescence of perchlorate and chlorate salts or dry, granular flows.
[6]  oai:arXiv.org:1505.05403  [pdf] - 1263029
The effect of craters on the lunar neutron flux
Comments: 14 pages, 13 figures, minor changes to match published version
Submitted: 2015-05-20, last modified: 2015-08-17
The variation of remotely sensed neutron count rates is measured as a function of cratercentric distance using data from the Lunar Prospector Neutron Spectrometer. The count rate, stacked over many craters, peaks over the crater centre, has a minimum near the crater rim, and at larger distances, it increases to a mean value that is up to 1% lower than the mean count rate observed over the crater. A simple model is presented, based upon an analytical topographical profile for the stacked craters fitted to data from the Lunar Orbiter Laser Altimeter (LOLA). The effect of topography coupled with neutron beaming from the surface largely reproduces the observed count rate profiles. However, a model that better fits the observations can be found by including the additional freedom to increase the neutron emissivity of the crater area by ~0.35% relative to the unperturbed surface. It is unclear what might give rise to this effect, but it may relate to additional surface roughness in the vicinities of craters. The amplitude of the crater-related signal in the neutron count rate is small, but not too small to demand consideration when inferring water-equivalent hydrogen (WEH) weight percentages in polar permanently shaded regions (PSRs). If the crater-wide count rate excess is concentrated into a much smaller PSR, then it can lead to a significantly biased inferred WEH weight percentage. For instance, it may increase the inferred WEH for Cabeus crater at the Moon's South Pole from ~1% to ~4%.
[7]  oai:arXiv.org:1501.05712  [pdf] - 925671
The Local-time variations of Lunar Prospector epithermal-neutron data
Comments: 8 pages, 7 figures and 3 tables
Submitted: 2015-01-22
We assess local-time variations of epithermal-neutron count rates measured by the Lunar Prospector Neutron Spectrometer. We investigate the nature of these variations and find no evidence to support the idea that such variations are caused by diurnal variations of hydrogen concentration across the lunar surface. Rather we find an anticorrelation between instrumental temperature and epithermal-neutron count rate. We have also found that the measured counts are dependent on the temperatures of the top decimeters of the lunar subsurface as constrained by the Lunar Reconnaissance Orbiter Diviner Lunar Radiometer Experiment temperature measurements. Finally, we have made the first measurement of the effective leakage depth for epithermal-neutrons of ~20 cm.
[8]  oai:arXiv.org:1304.8123  [pdf] - 1166327
How well do we know the polar hydrogen distribution on the Moon?
Comments: 12 pages, 13 figures
Submitted: 2013-04-30
A detailed comparison is made of results from the Lunar Prospector Neutron Spectrometer (LPNS) and the Lunar Exploration Neutron Detector Collimated Sensors for EpiThermal Neutrons (LEND CSETN). Using the autocorrelation function and power spectrum of the polar count rate maps produced by these experiments, it is shown that the LEND CSETN has a footprint that is at least as big as would be expected for an omni-directional detector at an orbital altitude of 50 km. The collimated flux into the field of view of the collimator is negligible. Arguments put forward asserting otherwise are considered and found wanting for various reasons. The maps of lunar polar hydrogen with the highest contrast, i.e. spatial resolution, are those resulting from pixon image reconstructions of the LPNS data. These typically provide weight percentages of water equivalent hydrogen that are accurate to 30% within the polar craters.
[9]  oai:arXiv.org:1108.2048  [pdf] - 474715
A quantitative comparison of lunar orbital neutron data
Comments: 19 pages, 14 figures, updated version accepted by ApJ
Submitted: 2011-08-09, last modified: 2012-02-09
Data from the Lunar Exploration Neutron Detector (LEND) Collimated Sensors for Epithermal Neutrons (CSETN) are used in conjunction with a model based on results from the Lunar Prospector mission to quantify the extent of the background in the LEND CSETN. A simple likelihood analysis implies that at least 90% of the lunar component of the LEND CSETN flux results from high energy epithermal neutrons passing through the walls of the collimator. Thus, the effective full-width at half-maximum of the LEND CSETN is comparable with that of the omni-directional Lunar Prospector Neutron Spectrometer. The resulting map of high energy epithermal neutrons offers the opportunity to probe the hydrogen abundance at low latitudes, and provide constraints on the distribution of lunar water.
[10]  oai:arXiv.org:hep-ph/0605218  [pdf] - 115286
Testing the Unitarity of the CKM Matrix with a Space-Based Neutron Decay Experiment
Comments: 10 pages, 4 figures. Revised and updated for publication
Submitted: 2006-05-19, last modified: 2008-05-15
If the Standard Model is correct, and fundamental fermions exist only in the three generations, then the CKM matrix should be unitary. However, there remains a question over a deviation from unitarity from the value of the neutron lifetime. We discuss a simple space-based experiment that, at an orbit height of 500 km above Earth, would measure the kinetic-energy, solid-angle, flux spectrum of gravitationally bound neutrons (kinetic energy K<0.606 eV at this altitude). The difference between the energy spectrum of neutrons that come up from the Earth's atmosphere and that of the undecayed neutrons that return back down to the Earth would yield a measurement of the neutron lifetime. This measurement would be free of the systematics of laboratory experiments. A package of mass $<25$ kg could provide a 10^{-3} precision in two years.