sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Fechner, T.

Normalized to: Fechner, T.

5 article(s) in total. 375 co-authors, from 1 to 5 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1903.02464  [pdf] - 1859121
4MOST: Project overview and information for the First Call for Proposals
de Jong, R. S.; Agertz, O.; Berbel, A. Agudo; Aird, J.; Alexander, D. A.; Amarsi, A.; Anders, F.; Andrae, R.; Ansarinejad, B.; Ansorge, W.; Antilogus, P.; Anwand-Heerwart, H.; Arentsen, A.; Arnadottir, A.; Asplund, M.; Auger, M.; Azais, N.; Baade, D.; Baker, G.; Baker, S.; Balbinot, E.; Baldry, I. K.; Banerji, M.; Barden, S.; Barklem, P.; Barthélémy-Mazot, E.; Battistini, C.; Bauer, S.; Bell, C. P. M.; Bellido-Tirado, O.; Bellstedt, S.; Belokurov, V.; Bensby, T.; Bergemann, M.; Bestenlehner, J. M.; Bielby, R.; Bilicki, M.; Blake, C.; Bland-Hawthorn, J.; Boeche, C.; Boland, W.; Boller, T.; Bongard, S.; Bongiorno, A.; Bonifacio, P.; Boudon, D.; Brooks, D.; Brown, M. J. I.; Brown, R.; Brüggen, M.; Brynnel, J.; Brzeski, J.; Buchert, T.; Buschkamp, P.; Caffau, E.; Caillier, P.; Carrick, J.; Casagrande, L.; Case, S.; Casey, A.; Cesarini, I.; Cescutti, G.; Chapuis, D.; Chiappini, C.; Childress, M.; Christlieb, N.; Church, R.; Cioni, M. -R. L.; Cluver, M.; Colless, M.; Collett, T.; Comparat, J.; Cooper, A.; Couch, W.; Courbin, F.; Croom, S.; Croton, D.; Daguisé, E.; Dalton, G.; Davies, L. J. M.; Davis, T.; de Laverny, P.; Deason, A.; Dionies, F.; Disseau, K.; Doel, P.; Döscher, D.; Driver, S. P.; Dwelly, T.; Eckert, D.; Edge, A.; Edvardsson, B.; Youssoufi, D. El; Elhaddad, A.; Enke, H.; Erfanianfar, G.; Farrell, T.; Fechner, T.; Feiz, C.; Feltzing, S.; Ferreras, I.; Feuerstein, D.; Feuillet, D.; Finoguenov, A.; Ford, D.; Fotopoulou, S.; Fouesneau, M.; Frenk, C.; Frey, S.; Gaessler, W.; Geier, S.; Fusillo, N. Gentile; Gerhard, O.; Giannantonio, T.; Giannone, D.; Gibson, B.; Gillingham, P.; González-Fernández, C.; Gonzalez-Solares, E.; Gottloeber, S.; Gould, A.; Grebel, E. K.; Gueguen, A.; Guiglion, G.; Haehnelt, M.; Hahn, T.; Hansen, C. J.; Hartman, H.; Hauptner, K.; Hawkins, K.; Haynes, D.; Haynes, R.; Heiter, U.; Helmi, A.; Aguayo, C. Hernandez; Hewett, P.; Hinton, S.; Hobbs, D.; Hoenig, S.; Hofman, D.; Hook, I.; Hopgood, J.; Hopkins, A.; Hourihane, A.; Howes, L.; Howlett, C.; Huet, T.; Irwin, M.; Iwert, O.; Jablonka, P.; Jahn, T.; Jahnke, K.; Jarno, A.; Jin, S.; Jofre, P.; Johl, D.; Jones, D.; Jönsson, H.; Jordan, C.; Karovicova, I.; Khalatyan, A.; Kelz, A.; Kennicutt, R.; King, D.; Kitaura, F.; Klar, J.; Klauser, U.; Kneib, J.; Koch, A.; Koposov, S.; Kordopatis, G.; Korn, A.; Kosmalski, J.; Kotak, R.; Kovalev, M.; Kreckel, K.; Kripak, Y.; Krumpe, M.; Kuijken, K.; Kunder, A.; Kushniruk, I.; Lam, M. I; Lamer, G.; Laurent, F.; Lawrence, J.; Lehmitz, M.; Lemasle, B.; Lewis, J.; Li, B.; Lidman, C.; Lind, K.; Liske, J.; Lizon, J. -L.; Loveday, J.; Ludwig, H. -G.; McDermid, R. M.; Maguire, K.; Mainieri, V.; Mali, S.; Mandel, H.; Mandel, K.; Mannering, L.; Martell, S.; Delgado, D. Martinez; Matijevic, G.; McGregor, H.; McMahon, R.; McMillan, P.; Mena, O.; Merloni, A.; Meyer, M. J.; Michel, C.; Micheva, G.; Migniau, J. -E.; Minchev, I.; Monari, G.; Muller, R.; Murphy, D.; Muthukrishna, D.; Nandra, K.; Navarro, R.; Ness, M.; Nichani, V.; Nichol, R.; Nicklas, H.; Niederhofer, F.; Norberg, P.; Obreschkow, D.; Oliver, S.; Owers, M.; Pai, N.; Pankratow, S.; Parkinson, D.; Parry, I.; Paschke, J.; Paterson, R.; Pecontal, A.; Phillips, D.; Pillepich, A.; Pinard, L.; Pirard, J.; Piskunov, N.; Plank, V.; Plüschke, D.; Pons, E.; Popesso, P.; Power, C.; Pragt, J.; Pramskiy, A.; Pryer, D.; Quattri, M.; Queiroz, A. B. de Andrade; Quirrenbach, A.; Rahurkar, S.; Raichoor, A.; Ramstedt, S.; Rau, A.; Recio-Blanco, A.; Reiss, R.; Renaud, F.; Revaz, Y.; Rhode, P.; Richard, J.; Richter, A. D.; Rix, H. -W.; Robotham, A. S. G.; Roelfsema, R.; Romaniello, M.; Rosario, D.; Rothmaier, F.; Roukema, B.; Ruchti, G.; Rupprecht, G.; Rybizki, J.; Ryde, N.; Saar, A.; Sadler, E.; Sahlén, M.; Salvato, M.; Sassolas, B.; Saunders, W.; Saviauk, A.; Sbordone, L.; Schmidt, T.; Schnurr, O.; Scholz, R. -D.; Schwope, A.; Seifert, W.; Shanks, T.; Sheinis, A.; Sivov, T.; Skúladóttir, Á.; Smartt, S.; Smedley, S.; Smith, G.; Smith, R.; Sorce, J.; Spitler, L.; Starkenburg, E.; Steinmetz, M.; Stilz, I.; Storm, J.; Sullivan, M.; Sutherland, W.; Swann, E.; Tamone, A.; Taylor, E. N.; Teillon, J.; Tempel, E.; ter Horst, R.; Thi, W. -F.; Tolstoy, E.; Trager, S.; Traven, G.; Tremblay, P. -E.; Tresse, L.; Valentini, M.; van de Weygaert, R.; Ancker, M. van den; Veljanoski, J.; Venkatesan, S.; Wagner, L.; Wagner, K.; Walcher, C. J.; Waller, L.; Walton, N.; Wang, L.; Winkler, R.; Wisotzki, L.; Worley, C. C.; Worseck, G.; Xiang, M.; Xu, W.; Yong, D.; Zhao, C.; Zheng, J.; Zscheyge, F.; Zucker, D.
Comments: Part of the 4MOST issue of The Messenger, published in preparation of 4MOST Community Workshop, see http://www.eso.org/sci/meetings/2019/4MOST.html
Submitted: 2019-03-06, last modified: 2019-04-01
We introduce the 4-metre Multi-Object Spectroscopic Telescope (4MOST), a new high-multiplex, wide-field spectroscopic survey facility under development for the four-metre-class Visible and Infrared Survey Telescope for Astronomy (VISTA) at Paranal. Its key specifications are: a large field of view (FoV) of 4.2 square degrees and a high multiplex capability, with 1624 fibres feeding two low-resolution spectrographs ($R = \lambda/\Delta\lambda \sim 6500$), and 812 fibres transferring light to the high-resolution spectrograph ($R \sim 20\,000$). After a description of the instrument and its expected performance, a short overview is given of its operational scheme and planned 4MOST Consortium science; these aspects are covered in more detail in other articles in this edition of The Messenger. Finally, the processes, schedules, and policies concerning the selection of ESO Community Surveys are presented, commencing with a singular opportunity to submit Letters of Intent for Public Surveys during the first five years of 4MOST operations.
[2]  oai:arXiv.org:1607.01269  [pdf] - 1528097
The Potsdam MRS Spectrograph - heritage of MUSE and the impact of cross-innovation in the process of technology transfer
Comments: 13 pages, 13 figures. Submitted in SPIE Astronomical Telescopes + Instrumentation, Paper No. 9912-72
Submitted: 2016-07-05, last modified: 2016-07-06
After having demonstrated that an IFU, attached to a microscope rather than to a telescope, is capable of differentiating complex organic tissue with spatially resolved Raman spectroscopy, we have launched a clinical validation program that utilizes a novel optimized fiber-coupled multi-channel spectrograph whose layout is based on the modular MUSE spectrograph concept. The new design features a telecentric input and has an extended blue performance, but otherwise maintains the properties of high throughput and excellent image quality over an octave of wavelength coverage with modest spectral resolution. We present the opto-mechanical layout and details of its optical performance.
[3]  oai:arXiv.org:1505.06492  [pdf] - 1056016
PEPSI: The high-resolution echelle spectrograph and polarimeter for the Large Binocular Telescope
Comments:
Submitted: 2015-05-24
PEPSI is the bench-mounted, two-arm, fibre-fed and stabilized Potsdam Echelle Polarimetric and Spectroscopic Instrument for the 2x8.4 m Large Binocular Telescope (LBT). Three spectral resolutions of either 43 000, 120 000 or 270 000 can cover the entire optical/red wavelength range from 383 to 907 nm in three exposures. Two 10.3kx10.3k CCDs with 9-{\mu}m pixels and peak quantum efficiencies of 96 % record a total of 92 echelle orders. We introduce a new variant of a wave-guide image slicer with 3, 5, and 7 slices and peak efficiencies between 96 %. A total of six cross dispersers cover the six wavelength settings of the spectrograph, two of them always simultaneously. These are made of a VPH-grating sandwiched by two prisms. The peak efficiency of the system, including the telescope, is 15% at 650 nm, and still 11% and 10% at 390 nm and 900 nm, respectively. In combination with the 110 m2 light-collecting capability of the LBT, we expect a limiting magnitude of 20th mag in V in the low-resolution mode. The R=120 000 mode can also be used with two, dual-beam Stokes IQUV polarimeters. The 270 000-mode is made possible with the 7-slice image slicer and a 100- {\mu}m fibre through a projected sky aperture of 0.74", comparable to the median seeing of the LBT site. The 43000-mode with 12-pixel sampling per resolution element is our bad seeing or faint-object mode. Any of the three resolution modes can either be used with sky fibers for simultaneous sky exposures or with light from a stabilized Fabry-Perot etalon for ultra-precise radial velocities. CCD-image processing is performed with the dedicated data-reduction and analysis package PEPSI-S4S. A solar feed makes use of PEPSI during day time and a 500-m feed from the 1.8 m VATT can be used when the LBT is busy otherwise. In this paper, we present the basic instrument design, its realization, and its characteristics.
[4]  oai:arXiv.org:1207.3981  [pdf] - 1553813
The ERA2 facility: towards application of a fiber-based astronomical spectrograph for imaging spectroscopy in life sciences
Comments: 10 pages, 9 figures, SPIE Conference "Astronomical Telescopes and Instrumentation" 2012, Amsterdam
Submitted: 2012-07-17
Astronomical instrumentation is most of the time faced with challenging requirements in terms of sensitivity, stability, complexity, etc., and therefore leads to high performance developments that at first sight appear to be suitable only for the specific design application at the telescope. However, their usefulness in other disciplines and for other applications is not excluded. The ERA2 facility is a lab demonstrator, based on a high-performance astronomical spectrograph, which is intended to explore the innovation potential of fiber-coupled multi-channel spectroscopy for spatially resolved spectroscopy in life science, material sciences, and other areas of research.
[5]  oai:arXiv.org:astro-ph/0502581  [pdf] - 71372
PMAS, the Potsdam Multi-Aperture Spectrophotometer. I. Design, Manufacture, and Performance
Comments: accepted for publication in PASP, 18 pages, 21 figures
Submitted: 2005-02-28
We describe the design, manufacture, commissioning, and performance of PMAS, the Potsdam Multi-Aperture Spectrophotometer. PMAS is a dedicated integral field spectrophotometer, optimized to cover the optical wavelength regime of 0.35--1um. It is based on the lens array -- fiber bundle principle of operation. The instrument employs an all-refractive fiber spectrograph, built with CaF2 optics, to provide good transmission and high image quality over the entire nominal wavelength range. A set of user-selectable reflective gratings provides low to medium spectral resolution in first order of approx. 1.5, 3.2, and 7 A, depending on the groove density (1200, 600, 300 gr/mm). While the standard integral field unit (IFU) uses a 16x16 element lens array, which provides seeing-limited sampling in a relatively small field-of-view (FOV) in one of three magnifications (8x8, 12x12, or 16x16 arcsec^2, respectively), a recently retrofitted bare fiber bundle IFU (PPak) expands the FOV to a hexagonal area with a footprint of 65x74 arcsec^2. Other special features include a cryogenic CCD camera for field acquisition and guiding, a nod-shuffle mode for beam switching and improved sky background subtraction, and a scanning Fabry-Perot etalon in combination with the standard IFU (PYTHEAS mode). PMAS was initially designed and built as an experimental traveling instrument with optical interfaces to various telescopes (Calar Alto 3.5m, ESO-VLT, LBT). It is offered as a common user instrument at Calar Alto under contract with MPIA Heidelberg since 2002.