Normalized to: Favazza, P.
[1]
oai:arXiv.org:1810.01096 [pdf] - 1759427
A 3.9 km baseline intensity interferometry photon counting experiment
Submitted: 2018-10-02
In the last years we have operated two very similar ultrafast photon counting
photometers (Iqueye and Aqueye+) on different telescopes. The absolute time
accuracy in time tagging the detected photon with these instruments is of the
order of 500 ps for hours of observation, allowing us to obtain, for example,
the most accurate ever light curve in visible light of the optical pulsars.
Recently we adapted the two photometers for working together on two telescopes
at Asiago (Italy), for realizing an Hanbury-Brown and Twiss Intensity
Interferometry like experiment with two 3.9 km distant telescopes. In this
paper we report about the status of the activity and on the very preliminary
results of our first attempt to measure the photon intensity correlation.
[2]
oai:arXiv.org:1808.00792 [pdf] - 1726847
Recovering pyramid WS gain in non-common path aberration correction mode
via deformable lens
Submitted: 2018-08-02
It is by now well known that pyramid based wavefront sensors, once in closed
loop, have the capability to improve more and more the gain as the reference
natural star image size is getting smaller on the pyramid pin. Especially in
extreme adaptive optics applications, in order to correct the non-common path
aberrations between the scientific and sensing channel, it is common use to
inject a certain amount of offset wavefront deformation into the DM(s),
departing at the same time the pyramid from the optimal working condition. In
this paper we elaborate on the possibility to correct the low order non-common
path aberrations at the pyramid wavefront sensor level by means of an adaptive
refractive lens placed on the optical path before the pyramid itself, allowing
the mitigation of the gain loss.
[3]
oai:arXiv.org:1609.01134 [pdf] - 1474446
Intensity Interferometry with Aqueye+ and Iqueye in Asiago
Submitted: 2016-09-05
Since a number of years our group is engaged in the design, construction and
operation of instruments with very high time resolution in the optical band for
applications to Quantum Astronomy and more conventional Astrophysics. Two
instruments were built to perform photon counting with sub-nanosecond temporal
accuracy. The first of the two, Aqueye+, is regularly mounted at the 1.8 m
Copernicus telescope in Asiago, while the second one, Iqueye, was mounted at
the ESO New Technology Telescope in Chile, and at the William Herschel
Telescope and Telescopio Nazionale Galileo on the Roque (La Palma, Canary
Islands). Both instruments deliver extraordinarily accurate results in optical
pulsar timing. Recently, Iqueye was moved to Asiago to be mounted at the 1.2 m
Galileo telescope to attempt, for the first time ever, experiments of optical
intensity interferometry (a` la Hanbury Brown and Twiss) on a baseline of a few
kilometers, together with the Copernicus telescope. This application was one of
the original goals for the development of our instrumentation. To carry out
these measurements, we are experimenting a new way of coupling the instruments
to the telescopes, by means of moderate-aperture, low-optical-attenuation
multi-mode optical fibers with a double-clad design. Fibers are housed in
dedicated optical interfaces attached to the focus of another instrument of the
1.8 m telescope (Aqueye+) or to the Nasmyth focus of the 1.2 m telescope
(Iqueye). This soft-mount solution has the advantage to facilitate the mounting
of the photon counters, to keep them under controlled temperature and humidity
conditions (reducing potential systematics related to varying ambient
conditions), and to mitigate scheduling requirements. Here we will describe the
first successful implementation of the Asiago intensity interferometer and
future plans for improving it.