Normalized to: Fatigoni, S.
[1]
oai:arXiv.org:2002.05254 [pdf] - 2048106
Optical Design and Characterization of 40-GHz Detector and Module for
the BICEP Array
Soliman, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
OBrient, R.;
Palladino, S.;
Prouve, T.;
Precup, N.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Schillaci, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Families of cosmic inflation models predict a primordial gravitational-wave
background that imprints B-mode polarization pattern in the Cosmic Microwave
Background (CMB). High sensitivity instruments with wide frequency coverage and
well-controlled systematic errors are needed to constrain the faint B-mode
amplitude. We have developed antenna-coupled Transition Edge Sensor (TES)
arrays for high-sensitivity polarized CMB observations over a wide range of
millimeter-wave bands. BICEP Array, the latest phase of the BICEP/Keck
experiment series, is a multi-receiver experiment designed to search for
inflationary B-mode polarization to a precision $\sigma$(r) between 0.002 and
0.004 after 3 full years of observations, depending on foreground complexity
and the degree of lensing removal. We describe the electromagnetic design and
measured performance of BICEP Array low-frequency 40-GHz detector, their
packaging in focal plane modules, and optical characterization including
efficiency and beam matching between polarization pairs. We summarize the
design and simulated optical performance, including an approach to improve the
optical efficiency due to mismatch losses. We report the measured beam maps for
a new broad-band corrugation design to minimize beam differential ellipticity
between polarization pairs caused by interactions with the module housing
frame, which helps minimize polarized beam mismatch that converts CMB
temperature to polarization ($T \rightarrow P$) anisotropy in CMB maps.
[2]
oai:arXiv.org:2002.05219 [pdf] - 2065429
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Zhang, C.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.
Submitted: 2020-02-12
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial
gravitational waves in the Cosmic Microwave Background polarization, which
would be direct evidence of the inflation theory. While the tensor-to-scalar
ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further
improvements on this upper limit are hindered by polarized Galactic foreground
emissions and removal of gravitational lensing polarization. The 30/40 GHz
receiver of the BICEP Array (BA) will deploy at the end of 2019 and will
constrain the synchrotron foreground with unprecedented accuracy within the BK
sky patch. We will show the design of the 30/40 GHz detectors and test results
summarizing its performance. The low optical and atmospheric loading at these
frequencies requires our TES detectors to have low saturation power in order to
be photon-noise dominated. To realize the low thermal conductivity required
from a 250 mK base temperature, we developed new bolometer leg designs. We will
present the relevant measured detector parameters: G, Tc, Rn, Psat , and
spectral bands, and noise spectra. We achieved a per bolometer NEP including
all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon
noise level 1.54E-17 W/sqrt(Hz).
[3]
oai:arXiv.org:2002.05197 [pdf] - 2093193
Optical characterization of the Keck Array and BICEP3 CMB Polarimeters
from 2016 to 2019
Collaboration, The BICEP/Keck;
:;
Germaine, T. St;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Fliescher, S.;
Grayson, J. A.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Leitch, E. M.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tolan, J. E.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wong, C. L.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
The BICEP/Keck experiment (BK) is a series of small-aperture refracting
telescopes observing degree-scale Cosmic Microwave Background (CMB)
polarization from the South Pole in search of a primordial $B$-mode signature.
This $B$-mode signal arises from primordial gravitational waves interacting
with the CMB, and has amplitude parametrized by the tensor-to-scalar ratio $r$.
Since 2016, BICEP3 and the Keck Array have been observing with 4800 total
antenna-coupled transition-edge sensor detectors, with frequency bands spanning
95, 150, 220, and 270 GHz. Here we present the optical performance of these
receivers from 2016 to 2019, including far-field beams measured in situ with an
improved chopped thermal source and instrument spectral response measured with
a field-deployable Fourier Transform Spectrometer. As a pair differencing
experiment, an important systematic that must be controlled is the differential
beam response between the co-located, orthogonally polarized detectors. We
generate per-detector far-field beam maps and the corresponding differential
beam mismatch that is used to estimate the temperature-to-polarization leakage
in our CMB maps and to give feedback on detector and optics fabrication. The
differential beam parameters presented here were estimated using improved
low-level beam map analysis techniques, including efficient removal of
non-Gaussian noise as well as improved spatial masking. These techniques help
minimize systematic uncertainty in the beam analysis, with the goal of
constraining the bias on $r$ induced by temperature-to-polarization leakage to
be subdominant to the statistical uncertainty. This is essential as we progress
to higher detector counts in the next generation of CMB experiments.
[4]
oai:arXiv.org:2002.05228 [pdf] - 2048104
Design and performance of the first BICEP Array receiver
Schillaci, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Branches of cosmic inflationary models, such as slow-roll inflation, predict
a background of primordial gravitational waves that imprints a unique
odd-parity B-mode pattern in the Cosmic Microwave Background (CMB) at
amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment
targets this primordial signature, the amplitude of which is parameterized by
the tensor-to-scalar ratio r, by observing the polarized microwave sky through
the exceptionally clean and stable atmosphere at the South Pole. B-mode
measurements require an instrument with exquisite sensitivity, tight control of
systematics, and wide frequency coverage to disentangle the primordial signal
from the Galactic foregrounds. BICEP Array represents the most recent stage of
the BK program, and comprises four BICEP3-class receivers observing at 30/40,
95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South
Pole during the 2019/2020 austral summer. After 3 full years of observations
with 30,000+ detectors, BICEP Array will measure primordial gravitational waves
to a precision $\sigma(r)$ between 0.002 and 0.004, depending on foreground
complexity and the degree of lensing removal. In this paper we give an overview
of the instrument, highlighting the design features in terms of cryogenics,
magnetic shielding, detectors and readout architecture as well as reporting on
the integration and tests that are ongoing with the first receiver at 30/40
GHz.
[5]
oai:arXiv.org:1909.01305 [pdf] - 2034407
Microwave multiplexing on the Keck Array
Cukierman, Ari;
Ahmed, Zeeshan;
Henderson, Shawn;
Young, Edward;
Yu, Cyndia;
Barkats, Denis;
Brown, David;
Chaudhuri, Saptarshi;
Cornelison, James;
D'Ewart, John M.;
Dierickx, Marion;
Dober, Bradley J.;
Dusatko, John;
Fatigoni, Sofia;
Filippini, Jeff P.;
Frisch, Josef C.;
Haller, Gunther;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karkare, Kirit S.;
Karpel, Ethan;
Kernasovskiy, Sarah A.;
Kovac, John M.;
Kovacs, Attila;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Smith, Stephen;
Germaine, Tyler St.;
Ullom, Joel N.;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vasquez, Jesus;
Willmert, Justin;
Zeng, Lingzhen;
Ade, P. A. R.;
Amiri, M.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Crumrine, M.;
Duband, L.;
Hall, G.;
Harrison, S.;
Hildebrandt, S. R.;
Hui, H.;
Kang, J.;
Kefeli, S.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Wu, W. L. K.;
Yang, H.;
Yoon, K. W.;
Zhang, C.
Submitted: 2019-09-03, last modified: 2020-01-17
We describe an on-sky demonstration of a microwave-multiplexing readout
system in one of the receivers of the Keck Array, a polarimetry experiment
observing the cosmic microwave background at the South Pole. During the austral
summer of 2018-2019, we replaced the time-division multiplexing readout system
with microwave-multiplexing components including superconducting microwave
resonators coupled to radio-frequency superconducting quantum interference
devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification
between room temperature and the cold stages, and a SLAC Microresonator Radio
Frequency system for the warm electronics. In the range 5-6 GHz, a single
coaxial cable reads out 528 channels. The readout system is coupled to
transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole
phased-array antennas. Observations began in April 2019, and we report here on
an initial characterization of the system performance.
[6]
oai:arXiv.org:1905.12276 [pdf] - 1909327
Strong evidence of Anomalous Microwave Emission from the flux density
spectrum of M31
Battistelli, E. S.;
Fatigoni, S.;
Murgia, M.;
Buzzelli, A.;
Carretti, E.;
Castangia, P.;
Concu, R.;
Cruciani, A.;
de Bernardis, P.;
Genova-Santos, R.;
Govoni, F.;
Guidi, F.;
Lamagna, L.;
Luzzi, G.;
Masi, S.;
Melis, A.;
Paladini, R.;
Piacentini, F.;
Poppi, S.;
Radiconi, F.;
Rebolo, R.;
Rubino-Martin, J. A.;
Tarchi, A.;
Vacca, V.
Submitted: 2019-05-29, last modified: 2019-07-02
We have observed the Andromeda galaxy, Messier 31 (M31), at 6.7GHz with the
Sardinia Radio Telescope. We mapped the radio emission in the C-band,
re-analyzed WMAP and Planck maps, as well as other ancillary data, and we have
derived an overall integrated flux density spectrum from the radio to the
infrared. This allowed us to estimate the emission budget from M31. Integrating
over the whole galaxy, we found strong and highly significant evidence for
anomalous microwave emission (AME), at the level of (1.45+0.17-0.19)Jy at the
peaking frequency of ~25GHz. Decomposing the spectrum into known emission
mechanisms such as free-free, synchrotron, thermal dust, and AME arising from
electric dipole emission from rapidly rotating dust grains, we found that the
overall emission from M31 is dominated, at frequencies below 10GHz, by
synchrotron emission with a spectral index of -1.10+0.10-0.08, with subdominant
free-free emission. At frequencies >10GHz, AME has a similar intensity to that
of synchrotron and free-free emission, overtaking them between 20GHz and 50GHz,
whereas thermal dust emission dominates the emission budget at frequencies
above 60GHz, as expected.
[7]
oai:arXiv.org:1809.03689 [pdf] - 1748092
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator
Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Henderson, Shawn W.;
Ahmed, Zeeshan;
Austermann, Jason;
Becker, Daniel;
Bennett, Douglas A.;
Brown, David;
Chaudhuri, Saptarshi;
Cho, Hsiao-Mei Sherry;
D'Ewart, John M.;
Dober, Bradley;
Duff, Shannon M.;
Dusatko, John E.;
Fatigoni, Sofia;
Frisch, Josef C.;
Gard, Jonathon D.;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karpel, Ethan D.;
Kernasovskiy, Sarah S.;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Reintsema, Carl D.;
Smith, Stephen R.;
Ullom, Joel;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vissers, Michael;
Yu, Cyndia
Submitted: 2018-09-11
The next generation of cryogenic CMB and submillimeter cameras under
development require densely instrumented sensor arrays to meet their science
goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of
sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will
require substantial improvements in cold and warm readout techniques. To reduce
the readout cost per sensor and integration complexity, efforts are presently
focused on achieving higher multiplexing density while maintaining readout
noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout
technologies in active development include Microwave Kinetic Inductance Sensors
(MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of
superconducting microwave resonators to densely channelize sub-Kelvin sensors
into the bandwidth of a microwave transmission line. We present advancements in
the development of a new warm readout system for microwave SQUID multiplexing,
the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF
system is unique in its ability to track each tone, minimizing the total RF
power required to read out each resonator, thereby significantly reducing the
linearity requirements on the cold and warm readout. Here, we present
measurements of the readout noise and linearity of the first full SMuRF system,
including a demonstration of closed-loop tone tracking on a 528 channel
cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential
readout solution for several future CMB projects including Simons Observatory,
BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the
platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES
calorimeter arrays.