Binospec: A Wide-field Imaging Spectrograph for the MMT
Comments: PASP in press; 45 pages, 59 figures
Submitted: 2019-05-08
Binospec is a high throughput, 370 to 1000 nm, imaging spectrograph that addresses two adjacent 8' by 15' fields of view. Binospec was commissioned in late 2017 at the f/5 focus of the 6.5m MMT and is now available to all MMT observers. Aperture masks cut from stainless steel with a laser cutter are used to define the entrance apertures that range from 15' long slits to hundreds of 2" slitlets. System throughputs, including the MMT's mirrors and the f/5 wide-field corrector peak at ~30%. Three reflection gratings, duplicated for the two beams, provide resolutions ($\lambda$/$\Delta \lambda$) between 1300 and $>$5000 with a 1" wide slit. Two through-the-mask guiders are used for target acquisition, mask alignment, guiding, and precision offsets. A full-time Shack-Hartmann wave front sensor allows continuous adjustment of primary mirror support forces, telescope collimation and focus. Active flexure control maintains spectrograph alignment and focus under varying gravity and thermal conditions.
[2]  oai:arXiv.org:astro-ph/0508554  [pdf] - 371776
Hectospec, the MMT's 300 Optical Fiber-Fed Spectrograph
Comments: 68 pages, 28 figures, to appear in December 2005 PASP
Submitted: 2005-08-25
The Hectospec is a 300 optical fiber fed spectrograph commissioned at the MMT in the spring of 2004. A pair of high-speed six-axis robots move the 300 fiber buttons between observing configurations within ~300 s and to an accuracy ~25 microns. The optical fibers run for 26 m between the MMT's focal surface and the bench spectrograph operating at R~1000-2000. Another high dispersion bench spectrograph offering R~5,000, Hectochelle, is also available. The system throughput, including all losses in the telescope optics, fibers, and spectrograph peaks at ~10% at the grating blaze in 1" FWHM seeing. Correcting for aperture losses at the 1.5" diameter fiber entrance aperture, the system throughput peaks at $\sim$17%. Hectospec has proven to be a workhorse instrument at the MMT. Hectospec and Hectochelle together were scheduled for 1/3 of the available nights since its commissioning. Hectospec has returned \~60,000 reduced spectra for 16 scientific programs during its first year of operation.