sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Farnik, Frantislav

Normalized to: Farnik, F.

4 article(s) in total. 41 co-authors, from 1 to 2 common article(s). Median position in authors list is 8,0.

[1]  oai:arXiv.org:1505.04333  [pdf] - 1245787
Imaging and Spectroscopic Observations of a Transient Coronal Loop: Evidence for the Non-Maxwellian $\kappa$-Distributions
Comments: The Astrophysical Journal, accepted
Submitted: 2015-05-16
We report on the SDO/AIA and Hinode/EIS observations of a transient coronal loop. The loop brightens up in the same location after the disappearance of an arcade formed during a B8.9-class microflare three hours earlier. EIS captures this loop during its brightening phase as observed in most of the AIA filters. We use the AIA data to study the evolution of the loop, as well as to perform the DEM diagnostics as a function of $\kappa$. Fe XI--XIII lines observed by EIS are used to perform the diagnostics of electron density and subsequently the diagnostics of $\kappa$. Using ratios involving the Fe XI 257.772\AA selfblend, we diagnose $\kappa$ $\lesssim$ 2, i.e., an extremely non-Maxwellian distribution. Using the predicted Fe line intensities derived from the DEMs as a function of $\kappa$, we show that, with decreasing $\kappa$, all combinations of ratios of line intensities converge to the observed values, confirming the diagnosed $\kappa$ $\lesssim$ 2. These results represent the first positive diagnostics of $\kappa$-distributions in the solar corona despite the limitations imposed by calibration uncertainties.
[2]  oai:arXiv.org:1411.0850  [pdf] - 1222982
X-ray Flare Spectra from the DIOGENESS Spectrometer and its concept applied to ChemiX on the Interhelioprobe spacecraft
Comments: Accepted for publication, Solar Physics
Submitted: 2014-11-04
The {\em DIOGENESS} X-ray crystal spectrometer on the {\em CORONAS-F} spacecraft operated for a single month (25~August to 17~September) in 2001 but in its short lifetime obtained one hundred and forty high-resolution spectra from some eight solar flares with {\em GOES} importance ranging from C9 to X5. The instrument included four scanning flat crystals with wavelength ranges covering the regions of \sixiii\ (6.65~\AA), \sxv\ (5.04~\AA), and \caxix\ (3.18~\AA) X-ray lines and associated dielectronic satellites. Two crystals covering the \caxix\ lines were oriented in a ``Dopplerometer'' manner, i.e. such that spatial and spectral displacements both of which commonly occur in flares can be separated. We describe the {\em DIOGENESS} spectrometer and the spectra obtained during flares which include lines not hitherto seen from spacecraft instruments. An instrument with very similar concept is presently being built for the two Russian {\em Interhelioprobe} spacecraft due for launch in 2020 and 2022 that will make a near-encounter (perihelion $\sim 0.3$ a.u.) to the Sun in its orbit. We outline the results that are likely to be obtained.
[3]  oai:arXiv.org:1203.6809  [pdf] - 1117664
Sphinx measurements of the 2009 solar minimum x-ray emission
Comments: Astrophysical Journal, in press. 14 pp, 3 figures
Submitted: 2012-03-30
The SphinX X-ray spectrophotometer on the CORONAS-PHOTON spacecraft measured soft X-ray emission in the 1-15 keV energy range during the deep solar minimum of 2009 with a sensitivity much greater than GOES. Several intervals are identified when the X-ray flux was exceptionally low, and the flux and solar X-ray luminosity are estimated. Spectral fits to the emission at these times give temperatures of 1.7-1.9 MK and emission measures between 4 x 10^47 cm^-3 and 1.1 x 10^48 cm^-3. Comparing SphinX emission with that from the Hinode X-ray Telescope, we deduce that most of the emission is from general coronal structures rather than confined features like bright points. For one of 27 intervals of exceptionally low activity identified in the SphinX data, the Sun's X-ray luminosity in an energy range roughly extrapolated to that of ROSAT (0.1-2.4 keV) was less than most nearby K and M dwarfs.
[4]  oai:arXiv.org:1109.6629  [pdf] - 967081
The Relationship Between Solar Radio and Hard X-ray Emission
Comments: This is an article prepared for a monograph on the physics of solar flares, inspired by RHESSI observations. The chapters appear as individual articles in Space Science Reviews (2011)
Submitted: 2011-09-29, last modified: 2011-10-01
This review discusses the complementary relationship between radio and hard X-ray observations of the Sun using primarily results from the era of the Reuven Ramaty High Energy Solar Spectroscopic Imager satellite. A primary focus of joint radio and hard X-ray studies of solar flares uses observations of nonthermal gyrosynchrotron emission at radio wavelengths and bremsstrahlung hard X-rays to study the properties of electrons accelerated in the main flare site, since it is well established that these two emissions show very similar temporal behavior. A quantitative prescription is given for comparing the electron energy distributions derived separately from the two wavelength ranges: this is an important application with the potential for measuring the magnetic field strength in the flaring region, and reveals significant differences between the electrons in different energy ranges. Examples of the use of simultaneous data from the two wavelength ranges to derive physical conditions are then discussed, including the case of microflares, and the comparison of images at radio and hard X-ray wavelengths is presented. There have been puzzling results obtained from observations of solar flares at millimeter and submillimeter wavelengths, and the comparison of these results with corresponding hard X-ray data is presented. Finally, the review discusses the association of hard X-ray releases with radio emission at decimeter and meter wavelengths, which is dominated by plasma emission (at lower frequencies) and electron cyclotron maser emission (at higher frequencies), both coherent emission mechanisms that require small numbers of energetic electrons. These comparisons show broad general associations but detailed correspondence remains more elusive.