Normalized to: Fantei-Caujolle, Y.
[1]
oai:arXiv.org:1904.07093 [pdf] - 1867330
A generalized differential image motion monitor
Submitted: 2019-04-15
We present the Generalised Differential Image Motion Monitor. It is a compact
instrument dedicated to measure 4 parameters of the optical turbulence: seeing,
isoplanatic angle, coherence time and wavefront coherence outer scale. GDIMM is
based on a small telescope (28cm diameter) equipped with a 3-holes mask at its
entrance pupil. The instrument is fully automatic, and performs continuous
monitoring of turbulence parameters at the Calern Observatory (France). This
paper gives a description of the instrument, data processing and error budget.
We present also statistics of 3.5 years of monitoring of turbulence parameters
above the Calern Observatory.
[2]
oai:arXiv.org:1811.07561 [pdf] - 1787105
A new generalized differential image motion monitor
Submitted: 2018-11-19
We present first results of a new instrument, the Generalized Differential
Image Motion Monitor (GDIMM), aiming at monitoring parameters of the optical
turbulence (seeing, isoplanatic angle, coherence time and outer scale). GDIMM
is based on a small telescope equipped with a 3-holes mask at its entrance
pupil. The seeing is measured by the classical DIMM technique using two
sub-pupils of the mask (6 cm diameter separated by a distance of 20 cm), the
isoplanatic angle is estimated from scintillation through the third sub-pupil
(its diameter is 10 cm, with a central obstruction of 4 cm). The coherence time
is deduced from the temporal structure function of the angle of arrival (AA)
fluctuations, thanks to the high-speed sampling rate of the camera. And the
difference of the motion variances from sub-apertures of different diameters
makes it possible to estimate the outer scale. GDIMM is a compact and portable
instrument, and can be remotely controlled by an operator. We show in this
paper the first results of test campaigns obtained in 2013 and 2014 at Nice
observatory and the Plateau de Calern (France). Comparison with simultaneous
data obtained with the Generalized Seeing Monitor (GSM) are also presented.
[3]
oai:arXiv.org:1811.07310 [pdf] - 1787091
Turbulence monitoring at the Plateau de Calern with the GDIMM instrument
Submitted: 2018-11-18
We present some statistics of turbulence monitoring at the Plateau de Calern
(France), with the Generalised Differential Image Motion Monitor (GDIMM). This
instrument allows to measure integrated parameters of the atmospheric
turbulence, i.e. seeing, isoplanatic angle, coherence time and outer scale,
with 2 minutes time resolution. It is running routinely since November 2015 and
is now fully automatic. A large dataset has been collected, leading to the
first statistics of turbulence above the Plateau de Calern.
[4]
oai:arXiv.org:1711.05604 [pdf] - 1605108
The ${\delta}$ Scuti pulsations of ${\beta}$ Pictoris as observed by
ASTEP from Antarctica
Mékarnia, D.;
Chapellier, E.;
Guillot, T.;
Abe, L.;
Agabi, A.;
De Pra, Y.;
Schmider, F. -X.;
Zwintz, K.;
Stevenson, K. B.;
Wang, J. J.;
Lagrange, A. -M.;
Bigot, L.;
Crouzet, N.;
Fantei-Caujolle, Y.;
Christille, J. M.;
Kalas, P.
Submitted: 2017-11-15
The Antartica Search for Transiting Extrasolar Planets (ASTEP), an
automatized 400 mm telescope located at Concordia station in Antarctica,
monitored beta Pictoris continuously to detect any variability linked to the
transit of the Hill sphere of its planet beta Pictoris b. The long observation
sequence, from March to September 2017, combined with the quality and high
level duty cycle of our data, enables us to detect and analyse the delta Scuti
pulsations of the star. Time series photometric data were obtained using
aperture photometry by telescope defocussing. The 66 418 data points were
analysed using the software package Period04. We only selected frequencies with
amplitudes that exceed four times the local noise level in the amplitude
spectrum. We detect 31 delta Scuti pulsation frequencies, 28 of which are new
detections. All the frequencies detected are in the interval 34.76-75.68 d-1 .
We also find that beta Pictoris exhibits at least one pulsation mode that
varies in amplitude over our monitoring duration of seven months.
[5]
oai:arXiv.org:1701.08235 [pdf] - 1535136
High-Resolution Altitude Profiles of the Atmospheric Turbulence with PML
at the Sutherland Observatory
Submitted: 2017-01-27
With the prospect of the next generation of ground-based telescopes, the
extremely large telescopes (ELTs), increasingly complex and demanding adaptive
optics (AO) systems are needed. This is to compensate for image distortion
caused by atmospheric turbulence and fully take advantage of mirrors with
diameters of 30 to 40 m. This requires a more precise characterization of the
turbulence. The PML (Profiler of Moon Limb) was developed within this context.
The PML aims to provide high-resolution altitude profiles of the turbulence
using differential measurements of the Moon limb position to calculate the
transverse spatio-angular covariance of the Angle of Arrival fluctuations. The
covariance of differential image motion for different separation angles is
sensitive to the altitude distribution of the seeing. The use of the continuous
Moon limb provides a large number of separation angles allowing for the
high-resolution altitude of the profiles. The method is presented and tested
with simulated data. Moreover a PML instrument was deployed at the Sutherland
Observatory in South Africa in August 2011. We present here the results of this
measurement campaign.