Normalized to: Fabris, L.
[1]
oai:arXiv.org:2002.04163 [pdf] - 2046557
Cosmic-ray Antinuclei as Messengers of New Physics: Status and Outlook
for the New Decade
von Doetinchem, P.;
Perez, K.;
Aramaki, T.;
Baker, S.;
Barwick, S.;
Bird, R.;
Boezio, M.;
Boggs, S. E.;
Cui, M.;
Datta, A.;
Donato, F.;
Evoli, C.;
Fabris, L.;
Fabbietti, L.;
Bueno, E. Ferronato;
Fornengo, N.;
Fuke, H.;
Gerrity, C.;
Coral, D. Gomez;
Hailey, C.;
Hooper, D.;
Kachelriess, M.;
Korsmeier, M.;
Kozai, M.;
Lea, R.;
Li, N.;
Lowell, A.;
Manghisoni, M.;
Moskalenko, I. V.;
Munini, R.;
Naskret, M.;
Nelson, T.;
Ng, K. C. Y.;
Nozzoli, F.;
Oliva, A.;
Ong, R. A.;
Osteria, G.;
Pierog, T.;
Poulin, V.;
Profumo, S.;
Poeschl, T.;
Quinn, S.;
Re, V.;
Rogers, F.;
Ryan, J.;
Saffold, N.;
Sakai, K.;
Salati, P.;
Schael, S.;
Serksnyte, L.;
Shukla, A.;
Stoessl, A.;
Tjemsland, J.;
Vannuccini, E.;
Vecchi, M.;
Winkler, M. W.;
Wright, D.;
Xiao, M.;
Xu, W.;
Yoshida, T.;
Zampa, G.;
Zuccon, P.
Submitted: 2020-02-10
The precise measurement of cosmic-ray antinuclei serves as an important means
for identifying the nature of dark matter and other new astrophysical
phenomena, and could be used with other cosmic-ray species to understand
cosmic-ray production and propagation in the Galaxy. For instance, low-energy
antideuterons would provide a "smoking gun" signature of dark matter
annihilation or decay, essentially free of astrophysical background. Studies in
recent years have emphasized that models for cosmic-ray antideuterons must be
considered together with the abundant cosmic antiprotons and any potential
observation of antihelium. Therefore, a second dedicated Antideuteron Workshop
was organized at UCLA in March 2019, bringing together a community of theorists
and experimentalists to review the status of current observations of cosmic-ray
antinuclei, the theoretical work towards understanding these signatures, and
the potential of upcoming measurements to illuminate ongoing controversies.
This review aims to synthesize this recent work and present implications for
the upcoming decade of antinuclei observations and searches. This includes
discussion of a possible dark matter signature in the AMS-02 antiproton
spectrum, the most recent limits from BESS Polar-II on the cosmic antideuteron
flux, and reports of candidate antihelium events by AMS-02; recent collider and
cosmic-ray measurements relevant for antinuclei production models; the state of
cosmic-ray transport models in light of AMS-02 and Voyager data; and the
prospects for upcoming experiments, such as GAPS. This provides a roadmap for
progress on cosmic antinuclei signatures of dark matter in the coming years.
[2]
oai:arXiv.org:1912.06571 [pdf] - 2014538
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking
for the GAPS Experiment
Rogers, Field;
Xiao, Mengjiao;
Perez, Kerstin;
Boggs, Steven;
Erjavec, Tyler;
Fabris, Lorenzo;
Fuke, Hideyuki;
Hailey, Charles J.;
Kozai, Masayoshi;
Lowell, Alex;
Madden, Norman;
Manghisoni, Massimo;
McBride, Steve;
Re, Valerio;
Riceputi, Elisa;
Saffold, Nathan;
Shimizu, Yuki;
Zampa, Gianluigi
Submitted: 2019-12-13
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150{\deg}C
above liquid nitrogen temperature, have been developed for the General
Antiparticle Spectrometer (GAPS) balloon mission and will form the first such
system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip
detectors have been verified in the lab to provide <4 keV FWHM energy
resolution for X-rays as well as tracking capability for charged particles,
while operating in conditions (~-40{\deg}C and ~1 Pa) achievable on a
long-duration balloon mission with a large detector payload. These
characteristics enable the GAPS silicon tracker system to identify cosmic
antinuclei via a novel technique based on exotic atom formation, de-excitation,
and annihilation. Production and large-scale calibration of ~1000 detectors has
begun for the first GAPS flight, scheduled for late 2021. The detectors
developed for GAPS may also have other applications, for example in heavy
nuclei identification.
[3]
oai:arXiv.org:1906.00054 [pdf] - 1995412
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking
in the GAPS experiment
Rogers, Field;
Xiao, Mengjiao;
Perez, Kerstin M.;
Boggs, Steven;
Erjavec, Tyler;
Fabris, Lorenzo;
Fuke, Hideyuki;
Hailey, Charles J.;
Kozai, Masayoshi;
Lowell, Alex;
Madden, Norman;
Manghisoni, Massimo;
McBride, Steve;
Re, Valerio;
Riceputi, Elisa;
Saffold, Nathan;
Shimizu, Yuki
Submitted: 2019-05-31, last modified: 2019-11-08
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique
geometric, performance, and cost requirements of the General Antiparticle
Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The
GAPS Si(Li) detectors will form the first large-area, relatively
high-temperature Si(Li) detector system with sensitivity to X-rays to operate
at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors
provide the active area, X-ray absorption efficiency, energy resolution, and
particle tracking capability necessary for the GAPS exotic-atom particle
identification technique. In this paper, the detector performance is validated
on the bases of X-ray energy resolution and reconstruction of cosmic minimum
ionizing particle (MIP) signals. We use the established noise model for
semiconductor detectors to distinguish sources of noise due to the detector
from those due to signal processing electronics. We demonstrate that detectors
with either 4 strips or 8 strips can provide the required $\lesssim$4 keV
(FWHM) X-ray energy resolution at flight temperatures of $-35$ to
$-45^{\circ}$C, given the proper choice of signal processing electronics.
Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic
balloon flight, scheduled for late 2021.
[4]
oai:arXiv.org:1909.01682 [pdf] - 1955438
Front-end electronics for the GAPS tracker
Submitted: 2019-09-04
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon-borne
mission to indirectly search for dark matter through sensitive observation of
cosmic antiparticles. The first flight is planned for late 2021. GAPS is the
first experiment optimized specifically for detection of low-energy (< 0.25
GeV/n) antideuterons, which are recognized as distinctive signals from dark
matter annihilation or decay in the Galactic halo. To achieve high sensitivity
to cosmic antinuclei in this low-energy range, GAPS uses a novel particle
identification method based on exotic atom capture and decay. The GAPS
instrument consists of ten planes of 1440 10 cm-diameter, 2.5 mm-thick, 8-strip
lithium drifted silicon (Si(Li)) detectors, which constitutes the tracker,
surrounded by a plastic scintillator time-of-flight system. A new fabrication
technique has been developed to satisfy the stringent requirements of the
mission. In this contribution, we describe the front-end electronics of the
tracker of GAPS. The system is composed of front-end ASICs and power supplies.
The ASICs provide readout and digitization of the signal (with an 11-bit ADC)
in a wide dynamic range (10 keV - 100 MeV). Every ASIC has 32 channels and
performs the readout for 4 detectors, for a total amount of 11520 channels. The
ASIC analog front-end is based on a dynamic compression technique to handle a
large range of signal amplitudes and features a low noise performance,
achieving the required 4 keV resolution at low energies. The power system
supplies both bias voltages for the Si(Li) detectors and low voltages for the
electronics. 36th
[5]
oai:arXiv.org:1908.03154 [pdf] - 1931578
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Bird, R.;
Aramaki, T.;
Boezio, M.;
Boggs, S. E.;
Bonvicini, V.;
Campana, D.;
Craig, W. W.;
Everson, E.;
Fabris, L.;
Fuke, H.;
Gahbauer, F.;
Garcia, I.;
Gerrity, C.;
Hailey, C. J.;
Hayashi, T.;
Kato, C.;
Kawachi, A.;
Kondo, M.;
Kozai, M.;
Lowell, A.;
Manghisoni, M.;
Marcelli, N.;
Martucci, M.;
Mognet, S. I.;
Munakata, K.;
Munini, R.;
Okazaki, S.;
Olson, J.;
Ong, R. A.;
Osteria, G.;
Perez, K.;
Quinn, S.;
Re, V.;
Riceputi, E.;
Rogers, F.;
Ryan, J. L.;
Saffold, N.;
Scotti, V.;
Shimizu, Y.;
Sparvoli, R.;
Stoessl, A.;
Takeuchi, S.;
Vannuccini, E.;
von Doetinchem, P.;
Wada, T.;
Xiao, M.;
Yoshida, A.;
Yoshida, T.;
Zampa, G.;
Zweerink, J.
Submitted: 2019-08-08
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark
matter search by measuring low-energy ($\mathrm{E} < 0.25
\mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are
low-energy antideuterons produced in the annihilation or decay of dark matter.
At these energies antideuterons from secondary/tertiary interactions are
expected to have very low fluxes, significantly below those predicted by
well-motivated, beyond the standard model theories. GAPS will also conduct
low-energy antiproton and antihelium searches. Combined, these observations
will provide a powerful search for dark matter and provide the best
observations to date on primordial black hole evaporation on Galactic length
scales.
The GAPS instrument detects antinuclei using the novel exotic atom technique.
It consists of a central tracker with a surrounding time-of-flight (TOF)
system. The tracker is a one cubic meter volume containing 10 cm-diameter
lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator
system that will both trigger the Si(Li) tracker and enable better
reconstruction of particle tracks. After coming to rest in the tracker,
antinuclei will form an excited exotic atom. This will then de-excite via
characteristic X-ray transitions before producing a pion/proton star when the
antiparticle annihilates with the nucleus. This unique event topology will give
GAPS the nearly background-free detection capability required for a rare-event
search.
Here we present the scientific motivation for the GAPS experiment, its design
and its current status as it prepares for flight in the austral summer of
2021-22.
[6]
oai:arXiv.org:1903.03663 [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.;
Giampa, P.;
Retiere, F.;
Kroeger, J.;
Zhang, G.;
Ward, M.;
Margetak, P.;
Lic, G.;
Tsang, T.;
Doria, L.;
Kharusi, S. Al;
Alfaris, M.;
Anton, G.;
Arnquist, I. J.;
Badhrees, I.;
Barbeau, P. S.;
Beck, D.;
Belov, V.;
Bhatta, T.;
Blatchford, J.;
Brodsky, J. P.;
Brown, E.;
Brunner, T.;
Cao, G. F.;
Cao, L.;
Cen, W. R.;
Chambers, C.;
Charlebois, S. A.;
Chiu, M.;
Cleveland, B.;
Coon, M.;
Craycraft, A.;
Dalmasson, J.;
Daniels, T.;
Darroch, L.;
Daugherty, S. J.;
Croix, A. De St.;
Der Mesrobian-Kabakian, A.;
DeVoe, R.;
Dilling, J.;
Ding, Y. Y.;
Dolinski, M. J.;
Dragone, A.;
Echevers, J.;
Elbeltagi, M.;
Fabris, L.;
Fairbank, D.;
Fairbank, W.;
Farine, J.;
Feyzbakhsh, S.;
Fontaine, R.;
Gautam, P.;
Giacomini, G.;
Gornea, R.;
Gratta, G.;
Hansen, E. V.;
Heffner, M.;
Hoppe, E. W.;
Hoßl, J.;
House, A.;
Hughes, M.;
Ito, Y.;
Iverson, A.;
Jamil, A.;
Jewell, M. J.;
Jiang, X. S.;
Karelin, A.;
Kaufman, L. J.;
Kodroff, D.;
Koffas, T.;
Krucken, R.;
Kuchenkov, A.;
Kumar, K. S.;
Lana, Y.;
Larson, A.;
Lenardo, B. G.;
Leonarda, D. S.;
Lik, S.;
Li, Z.;
Licciardi, C.;
Linw, Y. H.;
Lv, P.;
MacLellan, R.;
McElroy, T.;
Medina-Peregrina, M.;
Michel, T.;
Mong, B.;
Moore, D. C.;
Murray, K.;
Nakarmi, P.;
Newby, R. J.;
Ning, Z.;
Njoya, O.;
Nolet, F.;
Nusair, O.;
Odgers, K.;
Odian, A.;
Oriunno, M.;
Orrell, J. L.;
Ortega, G. S.;
Ostrovskiy, I.;
Overman, C. T.;
Parent, S.;
Piepkez, A.;
Pocar, A.;
Pratte, J. -F.;
Qiu, D.;
Radeka, V.;
Raguzin, E.;
Rescia, S.;
Richman, M.;
Robinson, A.;
Rossignol, T.;
Rowson, P. C.;
Roy, N.;
Saldanha, R.;
Sangiorgio, S.;
VIII, K. Skarpaas;
Soma, A. K.;
St-Hilaire, G.;
Stekhanov, V.;
Stiegler, T.;
Sun, X. L.;
Tarka, M.;
Todd, J.;
Tolba, T.;
Totev, T. I.;
Tsang, R.;
Vachon, F.;
Veeraraghavan, V.;
Visser, G.;
Vuilleumier, J. -L.;
Wagenpfeil, M.;
Walent, M.;
Wang, Q.;
Watkins, J.;
Weber, M.;
Wei, W.;
Wen, L. J.;
Wichoski, U.;
Wu, S. X.;
Wu, W. H.;
Wu, X.;
Xia, Q.;
Yang, H.;
Yang, L.;
Yen, Y. -R.;
Zeldovich, O.;
Zhao, J.;
Zhou, Y.;
Ziegler, T.
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N:
S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers
(SiPMs) as part of the development of a solution for the detection of liquid
xenon scintillation light for the nEXO experiment. Various SiPM features, such
as: dark noise, gain, correlated avalanches, direct crosstalk and Photon
Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs
were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233
\text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163
\text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse
in the $1 \upmu\text{s}$ interval following the trigger pulse of
$0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is
$0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are
within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two
different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of
$189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we
report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a
saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both
values are well below the $24\text{ }\%$ saturation PDE advertised by
Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over
voltage is below the nEXO PDE requirement. The first one instead yields a PDE
that is marginally close to meeting the nEXO specifications. This suggests that
with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an
alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[7]
oai:arXiv.org:1904.05938 [pdf] - 1866492
Astro 2020 Science White Paper: Cosmic-ray Antinuclei as Messengers for
Dark Matter
Perez, Kerstin;
von Doetinchem, Philip;
Aramaki, Tsuguo;
Boezio, Mirko;
Boggs, Steven E.;
Craig, William W.;
Fabris, Lorenzo;
Fuke, Hideyuki;
Gahbauer, Florian;
Hailey, Charles J.;
Ong, Rene
Submitted: 2019-04-11
The origin of dark matter is a driving question of modern physics. Low-energy
antideuterons provide a "smoking gun" signature of dark matter annihilation or
decay, essentially free of astrophysical background. Low-energy antiprotons are
a vital partner for this analysis, and low-energy antihelium could provide
further discovery space for new physics. In the coming decade, AMS-02 will
continue accumulating the large statistics and systematic understanding
necessary for it to probe rare antinuclei signatures, and GAPS, which is the
first experiment optimized specifically for low-energy cosmic antinuclei, will
begin several Antarctic balloon campaigns. The connection of cosmic-ray
antinuclei and dark matter is reviewed and the outlook in light of experimental
progress is presented.
[8]
oai:arXiv.org:1809.09714 [pdf] - 1757324
GAPS: A New Cosmic Ray Anti-matter Experiment
Quinn, S.;
Aramaki, T.;
Bird, R.;
Boezio, M.;
Boggs, S. E.;
Bonvicini, V.;
Campana, D.;
Craig, W. W.;
von Doetinchem, P.;
Everson, E.;
Fabris, L.;
Gahbauer, F.;
Gerrity, C.;
Fuke, H.;
Hailey, C. J.;
Hayashi, T.;
Kato, C.;
Kawachi, A.;
Kozai, M.;
Lowell, A.;
Martucci, M.;
Mognet, S. I.;
Munini, R.;
Munakata, K.;
Okazaki, S.;
Ong, R. A.;
Osteria, G.;
Perez, K.;
Ryan, J.;
Re, V.;
Rogers, F.;
Saffold, N.;
Shimizu, Y.;
Sparvoli, R.;
Stoessl, A.;
Vannuccini, E.;
Yoshida, A.;
Yoshida, T.;
Zampa, G.;
Zweerink, J.
Submitted: 2018-09-25
The General AntiParticle Spectrometer (GAPS) is a balloon-borne instrument
designed to detect cosmic-ray antimatter using the novel exotic atom technique,
obviating the strong magnetic fields required by experiments like AMS, PAMELA,
or BESS. It will be sensitive to primary antideuterons with kinetic energies of
$\approx0.05-0.2$ GeV/nucleon, providing some overlap with the previously
mentioned experiments at the highest energies. For $3\times35$ day balloon
flights, and standard classes of primary antideuteron propagation models, GAPS
will be sensitive to $m_{\mathrm{DM}}\approx10-100$ GeV c$^{-2}$ WIMPs with a
dark-matter flux to astrophysical flux ratio approaching 100. This clean
primary channel is a key feature of GAPS and is crucial for a rare event
search. Additionally, the antiproton spectrum will be extended with high
statistics measurements to cover the $0.07 \leq E \leq 0.25 $ GeV domain. For
$E>0.2$ GeV GAPS data will be complementary to existing experiments, while
$E<0.2$ GeV explores a new regime. The first flight is scheduled for late 2020
in Antarctica. These proceedings will describe the astrophysical processes and
backgrounds relevant to the dark matter search, a brief discussion of detector
operation, and construction progress made to date.
[9]
oai:arXiv.org:1710.00452 [pdf] - 1589126
The GAPS Experiment to Search for Dark Matter using Low-energy
Antimatter
Ong, R. A.;
Aramaki, T.;
Bird, R.;
Boezio, M.;
Boggs, S. E.;
Carr, R.;
Craig, W. W.;
von Doetinchem, P.;
Fabris, L.;
Gahbauer, F.;
Gerrity, C.;
Fuke, H.;
Hailey, C. J.;
Kato, C.;
Kawachi, A.;
Kozai, M.;
Mognet, S. I.;
Munakata, K.;
Okazaki, S.;
Osteria, G.;
Perez, K.;
Re, V.;
Rogers, F.;
Saffold, N.;
Shimizu, Y.;
Yoshida, A.;
Yoshida, T.;
Zampa, G.;
Zweerink, J.
Submitted: 2017-10-01
The GAPS experiment is designed to carry out a sensitive dark matter search
by measuring low-energy cosmic ray antideuterons and antiprotons. GAPS will
provide a new avenue to access a wide range of dark matter models and masses
that is complementary to direct detection techniques, collider experiments and
other indirect detection techniques. Well-motivated theories beyond the
Standard Model contain viable dark matter candidates which could lead to a
detectable signal of antideuterons resulting from the annihilation or decay of
dark matter particles. The dark matter contribution to the antideuteron flux is
believed to be especially large at low energies (E < 1 GeV), where the
predicted flux from conventional astrophysical sources (i.e. from secondary
interactions of cosmic rays) is very low. The GAPS low-energy antiproton search
will provide stringent constraints on less than 10 GeV dark matter, will
provide the best limits on primordial black hole evaporation on Galactic length
scales, and will explore new discovery space in cosmic ray physics.
Unlike other antimatter search experiments such as BESS and AMS that use
magnetic spectrometers, GAPS detects antideuterons and antiprotons using an
exotic atom technique. This technique, and its unique event topology, will give
GAPS a nearly background-free detection capability that is critical in a
rare-event search. GAPS is designed to carry out its science program using
long-duration balloon flights in Antarctica. A prototype instrument was
successfully flown from Taiki, Japan in 2012. GAPS has now been approved by
NASA to proceed towards the full science instrument, with the possibility of a
first long-duration balloon flight in late 2020. Here we motivate low-energy
cosmic ray antimatter searches and discuss the current status of the GAPS
experiment and the design of the payload.
[10]
oai:arXiv.org:1303.3871 [pdf] - 711292
A Measurement of Atomic X-ray Yields in Exotic Atoms and Implications
for an Antideuteron-Based Dark Matter Search
Aramaki, T.;
Chan, S. K.;
Craig, W. W.;
Fabris, L.;
Gahbauer, F.;
Hailey, C. J.;
Koglin, J. E.;
Madden, N.;
Mori, K.;
Yu, H. T.;
Ziock, K. P.
Submitted: 2013-03-15, last modified: 2013-08-16
The General AntiParticle Spectrometer (GAPS) is a novel approach for the
indirect dark matter search that exploits cosmic antideuterons. GAPS utilizes a
distinctive detection method using atomic X-rays and charged particles from the
exotic atom as well as the timing, stopping range and dE/dX energy deposit of
the incoming particle, which provides excellent antideuteron identification. In
anticipation of a future balloon experiment, an accelerator test was conducted
in 2004 and 2005 at KEK, Japan, in order to prove the concept and to precisely
measure the X-ray yields of antiprotonic exotic atoms formed with different
target materials [1]. The X-ray yields of the exotic atoms with Al and S
targets were obtained as ~ 75%, which are higher than were previously assumed
in [2]. A simple, but comprehensive cascade model has been developed not only
to evaluate the measurement results but also to predict the X-ray yields of the
exotic atoms formed with any materials in the GAPS instrument. The cascade
model is extendable to any kind of exotic atom (any negatively charged
cascading particles with any target materials), and it was compared and
validated with other experimental data and cascade models for muonic and
antiprotonic exotic atoms. The X-ray yields of the antideuteronic exotic atoms
are predicted with a simple cascade model and the sensitivity for the GAPS
antideuteron search was estimated for the proposed long duration balloon
program [3], which suggests that GAPS has a strong potential to detect
antideuterons as a dark matter signature. A GAPS prototype flight (pGAPS) was
launched successfully from the JAXA/ISAS balloon facility in Hokkaido, Japan in
summer 2012 [4, 5] and a proposed GAPS science flight is to fly from Antarctica
in the austral summer of 2017-2018.
[11]
oai:arXiv.org:astro-ph/0509587 [pdf] - 76168
Accelerator Testing of the General Antiparticle Spectrometer, a Novel
Approach to Indirect Dark Matter Detection
Hailey, C J;
Aramaki, T;
Craig, W W;
Fabris, L;
Gahbauer, F;
Koglin, J E;
Madden, N;
Mori, K;
Yu, H T;
Ziock, K P
Submitted: 2005-09-20
We report on recent accelerator testing of a prototype general antiparticle
spectrometer (GAPS). GAPS is a novel approach for indirect dark matter searches
that exploits the antideuterons produced in neutralino-neutralino
annihilations. GAPS captures these antideuterons into a target with the
subsequent formation of exotic atoms. These exotic atoms decay with the
emission of X-rays of precisely defined energy and a correlated pion signature
from nuclear annihilation. This signature uniquely characterizes the
antideuterons. Preliminary analysis of data from a prototype GAPS in an
antiproton beam at the KEK accelerator in Japan has confirmed the
multi-X-ray/pion star topology and indicated X-ray yields consistent with prior
expectations. Moreover our success in utilizing solid rather than gas targets
represents a significant simplification over our original approach and offers
potential gains in sensitivity through reduced dead mass in the target area.