oai:arXiv.org:1908.00604 [pdf] - 2057711
Characterisation of the Particle-Induced Background of XMM-Newton
EPIC-pn: Short and Long Term Variability
Bulbul, Esra;
Kraft, Ralph;
Nulsen, Paul;
Freyberg, Michael;
Miller, Eric D.;
Grant, Catherine;
Bautz, Mark W.;
Burrows, David N.;
Allen, Steven;
Eraerds, Tanja;
Fioretti, Valentina;
Gasteldello, Fabio;
Ghirardini, Vittorio;
Hall, David;
Meidinger, Norbert;
Molendi, Silvano;
Rau, Arne;
Wilkins, Dan;
Wilms, Joern
Submitted: 2019-08-01, last modified: 2020-01-08
The particle-induced background of X-ray observatories is produced by
Galactic Cosmic Ray (GCR) primary protons, electrons, and He ions. Events due
to direct interaction with the detector are usually removed by on board
processing. The interactions of these primary particles with the detector
environment produce secondary particles that mimic X-ray events from celestial
sources and are much more difficult to identify. The filter wheel closed data
from the XMM-Newton EPIC-pn camera in small window mode (SWM) contains both the
X-ray-like background events and the events due to direct interactions with the
primary particles. From this data we demonstrate that X-ray-like background
events are spatially correlated with the primary particle interaction. This
result can be used to further characterise and reduce the non-X-ray background
in silicon-based X-ray detectors in current and future missions. We also show
that spectrum and pattern fractions of secondary particle events are different
from those produced by cosmic X-rays.
[2]
oai:arXiv.org:1702.01079 [pdf] - 1535391
The Wide Field Imager Instrument for Athena
Submitted: 2017-02-03
The WFI (Wide Field Imager) instrument is planned to be one of two
complementary focal plane cameras on ESA's next X-ray observatory Athena. It
combines unprecedented survey power through its large field of view of 40 amin
x 40 amin together with excellent count rate capability (larger than 1 Crab).
The energy resolution of the silicon sensor is state-of-the-art in the energy
band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of
a line at 7 keV will be better than 170 eV until the end of the nominal mission
phase. This performance is accomplished by using DEPFET active pixel sensors
with a pixel size of 130 x 130 microns is well suited to the on-axis angular
resolution of 5 arcsec half energy width (HEW) of the mirror system. Each
DEPFET pixel is a combined sensor-amplifier structure with a MOSFET integrated
onto a fully depleted 450 micron thick silicon bulk. Two detectors are planned
for the WFI instrument: A large-area detector comprising four sensors with a
total of 1024 x 1024 pixels and a fast detector optimized for high count rate
observations. This high count rate capable detector permits for bright point
sources with an intensity of 1 Crab a throughput of more than 80% and a pile-up
of less than 1 %. The fast readout of the DEPFET pixel matrices is facilitated
by an ASIC development, called VERITAS-2. Together with the Switcher-A, a
control ASIC that allows for operation of the DEPFET in rolling shutter mode,
these elements form the key components of the WFI detectors. The detectors are
surrounded by a graded-Z shield, which has in particular the purpose to avoid
fluorescence lines that would contribute to the instrument
background...[Abridged]