Normalized to: Englhauser, J.
[1]
oai:arXiv.org:1302.6283 [pdf] - 928601
CAST constraints on the axion-electron coupling
Barth, K.;
Belov, A.;
Beltran, B.;
Brauninger, H.;
Carmona, J. M.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Di Lella, L.;
Eleftheriadis, C.;
Englhauser, J.;
Fanourakis, G.;
Ribas, E. Ferrer;
Fischer, H.;
Franz, J.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Hassinoff, M. D.;
Heinsius, F. H.;
Hoffmann, D. H. H.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Kang, D.;
Konigsmann, K.;
Kotthaus, R.;
Kousouris, K.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Liolios, A.;
Ljubicic, A.;
Lutz, G.;
Luzon, G.;
Miller, D. W.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Redondo, J.;
Riege, H.;
Rodriguez, A.;
Ruz, J.;
Savvidis, I.;
Semertzidis, Y.;
Stewart, L.;
Van Bibber, K.;
Vieira, J. D.;
Villar, J. A.;
Vogel, J. K.;
Walckiers, L.;
Zioutas, K.
Submitted: 2013-02-25, last modified: 2013-04-19
In non-hadronic axion models, which have a tree-level axion-electron
interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton
scattering, and axio-recombination, the "BCA processes." Based on a new
calculation of this flux, including for the first time axio-recombination, we
derive limits on the axion-electron Yukawa coupling g_ae and axion-photon
interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a <
10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a
next-generation axion helioscope such as the proposed IAXO could push this
sensitivity into a range beyond stellar energy-loss limits and test the
hypothesis that white-dwarf cooling is dominated by axion emission.
[2]
oai:arXiv.org:physics/0702188 [pdf] - 901197
The X-ray Telescope of CAST
Kuster, M.;
Bräuninger, H.;
Cébrian, S.;
Davenport, M.;
Elefteriadis, C.;
Englhauser, J.;
Fischer, H.;
Franz, J.;
Friedrich, P.;
Hartmann, R.;
Heinsius, F. H.;
Hoffmann, D. H. H.;
Hoffmeister, G.;
Joux, J. N.;
Kang, D.;
Königsmann, K.;
Kotthaus, R.;
Papaevangelou, T.;
Lasseur, C.;
Lippitsch, A.;
Lutz, G.;
Morales, J.;
Rodríguez, A.;
Strüder, L.;
Vogel, J.;
Zioutas, K.
Submitted: 2007-02-22, last modified: 2007-05-10
The Cern Axion Solar Telescope (CAST) is in operation and taking data since
2003. The main objective of the CAST experiment is to search for a hypothetical
pseudoscalar boson, the axion, which might be produced in the core of the sun.
The basic physics process CAST is based on is the time inverted Primakoff
effect, by which an axion can be converted into a detectable photon in an
external electromagnetic field. The resulting X-ray photons are expected to be
thermally distributed between 1 and 7 keV. The most sensitive detector system
of CAST is a pn-CCD detector combined with a Wolter I type X-ray mirror system.
With the X-ray telescope of CAST a background reduction of more than 2 orders
off magnitude is achieved, such that for the first time the axion photon
coupling constant g_agg can be probed beyond the best astrophysical constraints
g_agg < 1 x 10^-10 GeV^-1.
[3]
oai:arXiv.org:astro-ph/0407637 [pdf] - 66479
Improving XMM-Newton EPIC pn data at low energies: method and
application to the Vela SNR
Dennerl, Konrad;
Aschenbach, Bernd;
Briel, Ulrich G.;
Brunner, Hermann;
Burwitz, Vadim;
Englhauser, Jakob;
Freyberg, Michael J.;
Haberl, Frank;
Hartner, Gisela;
Iyudin, Anatoli F.;
Kendziorra, Eckhard;
Meidinger, Norbert;
Pfeffermann, Elmar;
Pietsch, Wolfgang;
Strueder, Lothar;
Zavlin, Vyacheslav E.
Submitted: 2004-07-30
High quantum efficiency over a broad spectral range is one of the main
properties of the EPIC pn camera on-board XMM-Newton. The quantum efficiency
rises from ~75% at 0.2 keV to ~100% at 1 keV, stays close to 100% until 8 keV,
and is still ~90% at 10 keV. The EPIC pn camera is attached to an X-ray
telescope which has the highest collecting area currently available, in
particular at low energies (more than 1400 cm2 between 0.1 and 2.0 keV). Thus,
this instrument is very sensitive to the low-energy X-ray emission. However,
X-ray data at energies below ~0.2 keV are considerably affected by detector
effects, which become more and more important towards the lowest transmitted
energies. In addition to that, pixels which have received incorrect offsets
during the calculation of the offset map at the beginning of each observation,
show up as bright patches in low-energy images. Here we describe a method which
is not only capable of suppressing the contaminations found at low energies,
but which also improves the data quality throughout the whole EPIC pn spectral
range. This method is then applied to data from the Vela supernova remnant.
[4]
oai:arXiv.org:astro-ph/0204263 [pdf] - 48808
The discovery of X-rays from Venus with Chandra
Submitted: 2002-04-16
On January 10 and 13, 2001, Venus was observed for the first time with an
X-ray astronomy satellite. The observation, performed with the ACIS-I and
LETG/ACIS-S instruments on Chandra, yielded data of high spatial, spectral, and
temporal resolution. Venus is clearly detected as a half-lit crescent, with
considerable brightening on the sunward limb. The morphology agrees well with
that expected from fluorescent scattering of solar X-rays in the planetary
atmosphere. The radiation is observed at discrete energies, mainly at the
O-K_alpha energy of 0.53 keV. Fluorescence radiation is also detected from
C-K_alpha at 0.28 keV and, marginally, from N-K_alpha at 0.40 keV. An
additional emission line is indicated at 0.29 keV, which might be the signature
of the C 1s --> pi* transition in CO2 and CO. Evidence for temporal variability
of the X-ray flux was found at the 2.6 sigma level, with fluctuations by
factors of a few times indicated on time scales of minutes. All these findings
are fully consistent with fluorescent scattering of solar X-rays. No other
source of X-ray emission was detected, in particular none from charge exchange
interactions between highly charged heavy solar wind ions and atmospheric
neutrals, the dominant process for the X-ray emission of comets. This is in
agreement with the sensitivity of the observation.
[5]
oai:arXiv.org:astro-ph/0204237 [pdf] - 48782
Discovery of X-rays from Venus with Chandra
Submitted: 2002-04-15
On January 10 and 13, 2001, Venus was observed for the first time with an
X-ray astronomy satellite. The observation, performed with the ACIS-I and
LETG/ACIS-S instruments on Chandra, yielded data of high spatial, spectral, and
temporal resolution. Venus is clearly detected as a half-lit crescent, with
considerable brightening on the sunward limb. The morphology agrees well with
that expected from fluorescent scattering of solar X-rays in the planetary
atmosphere. The radiation is observed at discrete energies, mainly at the
O-K_alpha energy of 0.53 keV. Fluorescent radiation is also detected from
C-K_alpha at 0.28 keV and, marginally, from N-K_alpha at 0.40 keV. An
additional emission line is indicated at 0.29 keV, which might be the signature
of the C 1s --> pi* transition in CO_2 and CO. Evidence for temporal
variability of the X-ray flux was found at the 2.6 sigma level, with
fluctuations by factors of a few times indicated on time scales of minutes. All
these findings are fully consistent with fluorescent scattering of solar
X-rays. No other source of X-ray emission was detected, in particular none from
charge exchange interactions between highly charged heavy solar wind ions and
atmospheric neutrals, the dominant process for the X-ray emission of comets.
This is in agreement with the sensitivity of the observation.
[6]
oai:arXiv.org:astro-ph/0005061 [pdf] - 35833
A bright X-ray transient towards NGC 5128 (Centaurus A)
Submitted: 2000-05-03
During five ROSAT HRI observations in July 1995, a bright X-ray source
(designated 1RXH J132519.8-430312) was detected 2.5' south-west of the nucleus
of NGC 5128 (Centaurus A) at the outer regions of the elliptical galaxy. At
that time it was the brightest point source in the ROSAT HRI field-of-view. All
other ROSAT observations made before and after these observations show no trace
of the source suggesting that this is a highly variable object. Chandra
observations of Cen A made in September 1999 show a source at the ROSAT
position which may be the quiescent counterpart of the transient. It is very
probable that the transient is located in NGC 5128. Given the existence of a
transient source that close to the direction of NGC 5128, all observations (at
least in soft X-rays) of Cen A, with instruments of low spatial resolution,
must take the presence and variability of this object into account.
[7]
oai:arXiv.org:astro-ph/9909315 [pdf] - 108351
The ROSAT All-Sky Survey Bright Source Catalogue
Voges, Wolfgang;
Aschenbach, Bernd;
Boller, Thomas;
Braeuninger, Heinrich;
Briel, Ulrich;
Burkert, Wolfgang;
Dennerl, Konrad;
Englhauser, Jakob;
Gruber, Rainer;
Haberl, Frank;
Hartner, Gisela;
Hasinger, Guenther;
Pfeffermann, Elmar;
Pietsch, Wolfgang;
Predehl, Peter;
Rosso, Cristina;
Schmitt, Juergen H. M. M.;
Truemper, Joachim;
Zimmermann, Hans-Ulrich
Submitted: 1999-09-17, last modified: 1999-09-20
We present the ROSAT All-Sky Survey Bright Source Catalogue (RASS-BSC,
revision 1RXS) derived from the all-sky survey performed during the first half
year (1990/91) of the ROSAT mission. 18,811 sources are catalogued (i) down to
a limiting ROSAT PSPC count-rate of 0.05 cts/s in the 0.1-2.4 keV energy band,
(ii) with a detection likelihood of at least 15 and (iii) at least 15 source
counts. The 18,811 sources underwent both an automatic validation and an
interactive visual verification process in which for 94% of the sources the
results of the standard processing were confirmed. The remaining 6% have been
analyzed using interactive methods and these sources have been flagged. Flags
are given for (i) nearby sources; (ii) sources with positional errors; (iii)
extended sources; (iv) sources showing complex emission structures; and (v)
sources which are missed by the standard analysis software. Broad band (0.1-2.4
keV) images are available for sources flagged by (ii), (iii) and (iv). For each
source the ROSAT name, position in equatorial coordinates, positional error,
source count-rate and error, background count-rate, exposure time, two
hardness-ratios and errors, extent and likelihood of extent, likelihood of
detection, and the source extraction radius are provided. At a brightness limit
of 0.1 cts/s (8,547 sources) the catalogue represents a sky coverage of 92%.
The RASS-BSC, the table of possible identification candidates, and the broad
band images are available in electronic form (Voges et al. 1996a) via
http://wave.xray.mpe.mpg.de/rosat/catalogues/rass-bsc .
[8]
oai:arXiv.org:astro-ph/9712127 [pdf] - 99616
Properties of the X-ray pulsar GX 301-2 in hard X-rays
Submitted: 1997-12-09
In 1993-1994 a series of observations of the X-ray pulsar GX 301-2 by HEXE
onboard Mir-Kvant was made. A period of pulsations was measured (it varied
between 675 and 678 s) and pulse profiles in different energy bands were
produced. The measured luminosity in the 20-100 keV energy range changed
substantially between 8x10^34 and 7x10^35 d^2 erg/s (d is the distance to the
source in kpc). The obtained spectrum is quite satisfactory described by the
canonical model for X-ray pulsars with gamma=1.3, E_c~23 keV, E_f~9 keV. It
changed weakly between the observations, but was softest at brightness maximum.
Significant variations of the spectral hardness over the pulse phase were
detected, but the accumulated data are insufficient to quantify variations in
spectral parameters. No significant traces of cyclotron lines were found. An
interpretation of the pulse profiles as superposition of emissions from two
flat polar caps (with inclusion of gravitational lensing) leads to an estimate
of the angle between the magnetic axis and axis of rotation of 40-70 deg and an
angle between the direction to the observer and the rotation axis of 75-85 deg.