Normalized to: Emes, J.
[1]
oai:arXiv.org:1504.02900 [pdf] - 1300165
The Dark Energy Camera
Flaugher, B.;
Diehl, H. T.;
Honscheid, K.;
Abbott, T. M. C.;
Alvarez, O.;
Angstadt, R.;
Annis, J. T.;
Antonik, M.;
Ballester, O.;
Beaufore, L.;
Bernstein, G. M.;
Bernstein, R. A.;
Bigelow, B.;
Bonati, M.;
Boprie, D.;
Brooks, D.;
Buckley-Geer, E. J.;
Campa, J.;
Cardiel-Sas, L.;
Castander, F. J.;
Castilla, J.;
Cease, H.;
Cela-Ruiz, J. M.;
Chappa, S.;
Chi, E.;
Cooper, C.;
da Costa, L. N.;
Dede, E.;
Derylo, G.;
DePoy, D. L.;
de Vicente, J.;
Doel, P.;
Drlica-Wagner, A.;
Eiting, J.;
Elliott, A. E.;
Emes, J.;
Estrada, J.;
Neto, A. Fausti;
Finley, D. A.;
Flores, R.;
Frieman, J.;
Gerdes, D.;
Gladders, M. D.;
Gregory, B.;
Gutierrez, G. R.;
Hao, J.;
Holland, S. E.;
Holm, S.;
Huffman, D.;
Jackson, C.;
James, D. J.;
Jonas, M.;
Karcher, A.;
Karliner, I.;
Kent, S.;
Kessler, R.;
Kozlovsky, M.;
Kron, R. G.;
Kubik, D.;
Kuehn, K.;
Kuhlmann, S.;
Kuk, K.;
Lahav, O.;
Lathrop, A.;
Lee, J.;
Levi, M. E.;
Lewis, P.;
Li, T. S.;
Mandrichenko, I.;
Marshall, J. L.;
Martinez, G.;
Merritt, K. W.;
Miquel, R.;
Munoz, F.;
Neilsen, E. H.;
Nichol, R. C.;
Nord, B.;
Ogando, R.;
Olsen, J.;
Palio, N.;
Patton, K.;
Peoples, J.;
Plazas, A. A.;
Rauch, J.;
Reil, K.;
Rheault, J. -P.;
Roe, N. A.;
Rogers, H.;
Roodman, A.;
Sanchez, E.;
Scarpine, V.;
Schindler, R. H.;
Schmidt, R.;
Schmitt, R.;
Schubnell, M.;
Schultz, K.;
Schurter, P.;
Scott, L.;
Serrano, S.;
Shaw, T. M.;
Smith, R. C.;
Soares-Santos, M.;
Stefanik, A.;
Stuermer, W.;
Suchyta, E.;
Sypniewski, A.;
Tarle, G.;
Thaler, J.;
Tighe, R.;
Tran, C.;
Tucker, D.;
Walker, A. R.;
Wang, G.;
Watson, M.;
Weaverdyck, C.;
Wester, W.;
Woods, R.;
Yanny, B.
Submitted: 2015-04-11
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of
view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on
Cerro Tololo near La Serena, Chile. The camera was designed and constructed by
the Dark Energy Survey Collaboration, and meets or exceeds the stringent
requirements designed for the wide-field and supernova surveys for which the
collaboration uses it. The camera consists of a five element optical corrector,
seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250
micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel
focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding
and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of
0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and
alignment capability. The camera is read out in 20 seconds with 6-9 electrons
readout noise. This paper provides a technical description of the camera's
engineering, construction, installation, and current status.
[2]
oai:arXiv.org:0711.2105 [pdf] - 900223
Radiation Tolerance of Fully-Depleted P-Channel CCDs Designed for the
SNAP Satellite
Dawson, Kyle;
Bebek, Chris;
Emes, John;
Holland, Steve;
Jelinsky, Sharon;
Karcher, Armin;
Kolbe, William;
Palaio, Nick;
Roe, Natalie;
Saha, Juhi;
Takasaki, Koki;
Wang, Guobin
Submitted: 2007-11-13
Thick, fully depleted p-channel charge-coupled devices (CCDs) have been
developed at the Lawrence Berkeley National Laboratory (LBNL). These CCDs have
several advantages over conventional thin, n-channel CCDs, including enhanced
quantum efficiency and reduced fringing at near-infrared wavelengths and
improved radiation tolerance. Here we report results from the irradiation of
CCDs with 12.5 and 55 MeV protons at the LBNL 88-Inch Cyclotron and with 0.1-1
MeV electrons at the LBNL Co60 source. These studies indicate that the LBNL
CCDs perform well after irradiation, even in the parameters in which
significant degradation is observed in other CCDs: charge transfer efficiency,
dark current, and isolated hot pixels. Modeling the radiation exposure over a
six-year mission lifetime with no annealing, we expect an increase in dark
current of 20 e/pixel/hr, and a degradation of charge transfer efficiency in
the parallel direction of 3e-6 and 1e-6 in the serial direction. The dark
current is observed to improve with an annealing cycle, while the parallel CTE
is relatively unaffected and the serial CTE is somewhat degraded. As expected,
the radiation tolerance of the p-channel LBNL CCDs is significantly improved
over the conventional n-channel CCDs that are currently employed in space-based
telescopes such as the Hubble Space Telescope.