Normalized to: Egorov, V.
[1]
oai:arXiv.org:1403.0475 [pdf] - 797476
A search for bremsstrahlung solar axions using the Majorana
low-background BEGe detector at Kimballton (MALBEK)
Abgrall, N.;
Aguayo, E.;
Avignone, F. T.;
Barabash, A. S.;
Bertrand, F. E.;
Boswell, M.;
Brudanin, V.;
Busch, M.;
Caldwell, A. S.;
Chan, Y-D.;
Christofferson, C. D.;
Combs, D. C.;
Cooper, R. J.;
Creswick, R. J.;
Detwiler, J. A.;
Doe, P. J.;
Efremenko, Yu.;
Egorov, V.;
Elliott, S. R.;
Fast, J. E.;
Finnerty, P.;
Fraenkle, F. M.;
Galindo-Uribarri, A.;
Giovanetti, G. K.;
Goett, J.;
Green, M. P.;
Gruszko, J.;
Guiseppe, V. E.;
Gusev, K.;
Hegai, A.;
Henning, R.;
Hoppe, E. W.;
Howard, S.;
Howe, M. A.;
Keeter, K. J.;
Kidd, M. F.;
Knecht, A.;
Kochetov, O.;
Konovalov, S. I.;
Kouzes, R. T.;
LaFerriere, B. D.;
Leon, J.;
Leviner, L. E.;
Loach, J. C.;
MacMullin, J.;
MacMullin, S.;
Marino, M. G.;
Martin, R. D.;
Mertens, S.;
Orrell, J. L.;
O'Shaughnessy, C.;
Overman, N. R.;
Phillips, D. G.;
Poon, A. W. P.;
Pushkin, K.;
Radford, D. C.;
Rielage, K.;
Robertson, R. G. H.;
Ronquest, M. C.;
Schubert, A. G.;
Shanks, B.;
Shirchenko, M.;
Snavely, K. J.;
Snyder, N.;
Steele, D.;
Suriano, A. M.;
Thompson, J.;
Timkin, V.;
Varner, R. L.;
Vasilyev, S.;
Vetter, K.;
Vorren, K.;
White, B. R.;
Wilkerson, J. F.;
Xu, W.;
Yakushev, E.;
Young, A. R.;
Yu, C. H.;
Yumatov, V.
Submitted: 2014-03-03, last modified: 2014-03-17
A low-background, high-purity germanium detector has been used to search for
evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound
of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ
model axions to electrons. The prospects for the sensitivity of the Majorana
Demonstrator array of point-contact germanium detectors to solar axions are
discussed in the context of the model-independent annual modulation due to the
seasonal variation of the earth-sun distance.
[2]
oai:arXiv.org:astro-ph/0012398 [pdf] - 1232610
Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon
Gamma-Ray Imaging Telescope (LXeGRIT)
Aprile, E.;
Oberlack, U. G.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid
xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is
designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an
angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a
field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional
spatial resolution as measured during pre-flight calibration experiments, are
$\Delta E_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively.
The detection efficiency for Compton events varies between 1.5% and 4%
depending on energy and event selection. We describe the instrument as flown on
May 7, 1999 and review its overall performance at balloon altitude. The launch
occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was
terminated about 9 hours later. The Crab was in the instrument FOV for a few
hours. Analysis of these data is in progress.
[3]
oai:arXiv.org:astro-ph/0012296 [pdf] - 1232605
Compton scattering sequence reconstruction algorithm for the liquid
xenon gamma-ray imaging telescope (LXeGRIT)
Submitted: 2000-12-13
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born
experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main
detector is a time projection chamber filled with high purity liquid xenon
(LXeTPC), in which the three-dimensional location and energy deposit of
individual \g -ray interactions are accurately measured in one homogeneous
volume. To determine the \g -ray initial direction (Compton imaging), as well
as to reject background, the correct sequence of interactions has to be
determined. Here we report the development and optimization of an algorithm to
reconstruct the Compton scattering sequence and show its performance on Monte
Carlo events and LXeGRIT data.
[4]
oai:arXiv.org:astro-ph/0012297 [pdf] - 1232606
Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray
Imaging Telescope (LXeGRIT)
Aprile, E.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Oberlack, U. G.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-13
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time
projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of
0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled
with high purity LXe. Both ionization and scintillation light signals are
detected to measure the energy deposits and the three spatial coordinates of
individual \g -ray interactions within the sensitive volume. The TPC has been
characterized with repeated measurements of its spectral and Compton imaging
response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be.
The detector shows a linear response to \g -rays in the energy range 511 keV
-4.4 MeV, with an energy resolution (FWHM) of $ \Delta E/E=8.8% \: \sqrt{1\MeV
/E}$. Compton imaging of \yt \g -ray events with two detected interactions is
consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.