sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Dyachkov, A.

Normalized to: Dyachkov, A.

8 article(s) in total. 33 co-authors, from 1 to 8 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:astro-ph/0111424  [pdf] - 46190
SIGMA Observations of the Bursting Pulsar GRO J1744-28
Comments: Accepted for publication in the Astrophysical Journal, 4 pages, 4 figures
Submitted: 2001-11-21
We present the results of the GRANAT/SIGMA hard X-/soft gamma-ray long-term monitoring of the Galactic Center (GC) region concerning the source GRO J1744-28, discovered on 1995 Dec. 2 by CGRO/BATSE. SIGMA observed the region containing the source in 14 opportunities between 1990 and 1997. In two of these observing sessions, corresponding to March 1996 and March 1997, GRO J1744-28 was detected with a confidence level greater than 5(sigma) in the 35-75 keV energy band without detection in the 75-150 keV energy band. For the other sessions, upper limits of the flux are indicated. The particular imaging capabilities of the SIGMA telescope allow us to identify, specifically, the source position in the very crowded GC region, giving us a mean flux of (73.1 +/- 5.5)E-11 and (44.7 +/- 6.4)E-11 ergs cm^-2 s^-1 in the 35-75 keV energy band, for the March 1996 and March 1997 observing sessions, respectively. Combining the March 1997 SIGMA and BATSE observations, we found evidence pointing to the type-II nature of the source bursts for this period. For the same observing campaigns, spectra were obtained in the 35 to 150 keV energy band. The best fit corresponds to an optically thin thermal Bremsstrahlung with F(50 keV)=(3.6 +/- 0.6)E-4 phot cm^-2 s^-1 keV^-1 and kT(Bremss)=28 +/- 7 keV, for the first campaign, and F(50 keV)=(2.3 +/- 0.7)E-4 phot cm^-2 s^-1 keV^-1 and kT(Bremss)=18 (+12/-7) keV, for the second. This kind of soft spectrum is typical of binary sources containing a neutron star as the compact object, in contrast to the harder spectra typical of systems containing a black hole candidate
[2]  oai:arXiv.org:astro-ph/9903212  [pdf] - 105616
Long-Term Variability of the Hard X-ray Source GRS 1758-258: GRANAT/SIGMA Observations
Comments: 18 pages with 5 figures. Astronomy Letters, 1999, 25 (in press)
Submitted: 1999-03-13, last modified: 1999-03-16
The results of GRANAT/SIGMA hard X-ray observations of GRS 1758-258 in 1990-1998 are presented. The source lies at ~5\arcdeg from the Galactic Center and was within the SIGMA field of view during the GRANAT surveys of this region. The total exposure time of the Galactic Center was 11x10^6 s. The regular SIGMA observations revealed strong variability of the source: the 40-150 keV flux varied at least by a factor of 8 on a time scale of a year, between less than 13 mCrab and ~100-110 mCrab. The average flux was ~60 mCrab in 1990-1998. The source's spectrum is well fitted by a power law with a photon index \alpha ~1.86 in the energy range 40 to 150 keV and becomes steeper at energies above ~100 keV. The radio and hard X-ray properties of GRS 1758-258 are similar to those of another Galactic Center source, 1E1740.7-2942. GRS 1758-258 and 1E1740.7-2942 are the two brightest hard X-ray sources in the Galactic Center region. Both sources have radio jets, similar X-ray luminosities (~10^37 erg/s), and spectra, and exhibit variations in the hard X-ray flux on long times scales by a factor of ~10 or more . In contrast to most of the known black hole candidates, which are X-ray transients, GRS 1758-258 and 1E1740.7-2942 were detected by SIGMA during most of the observations in 1990-1998. Assuming that this behavior of the sources implies the suppression of accretion-disk instability in the region of partial hydrogen ionization through X-ray heating, we impose constraints on the mass of the optical companion and on the orbital period of the binary system.
[3]  oai:arXiv.org:astro-ph/9901392  [pdf] - 104986
Deep SIGMA observations of the central square degree of the Galaxy
Comments: 4 pages LateX, 1 Postscript Figure, To appear in the Proceedings of the 3rd INTEGRAL workshop, Taormina, Italy, 1998
Submitted: 1999-01-28
The Center of the Milky Way emits radiation through all the electromagnetic spectrum due to the presence of several astrophysical phenomena. Various scientifical questions remain unsolved in the picture that emerge from observations, the main one being the presence and activity of a supermassive black hole at the Galactic Center. Also in the X-ray band a strong diffuse emission is detected up to 22 keV, it has been suggested that its origin is linked to past high energy activity of the Galactic Center. The French SIGMA soft gamma ray telescope on board the Russian Granat satellite observed the Galacti Center (GC) for abour 9 X 10^6 seconds from 1990 to the end of 1997. Its unique imaging capabilities coupled with the unprecedented exposure already allowed us to set preliminary constraints on the persistent high energy emission from Sgr A*. Here we present a new analysis of the complete set of observations of this region taking into account the possible presence of diffuse emission in the low energy channels. This allows us both to test current advection models of high energy emission from Sgr A* and to investigate on past high energy activity.
[4]  oai:arXiv.org:astro-ph/9808211  [pdf] - 102555
SIGMA and XTE observations of the soft X-ray transient XTEJ1755-324
Comments: 19 pages LaTeX, 6 Postscript figures included, Accepted by Astrophysical Journal
Submitted: 1998-08-20
We present observations of the X-ray transient XTEJ1755-324 performed during summer 1997 with the XTE satellite and with the SIGMA hard X-ray telescope onboard the GRANAT observatory. The source was first detected in soft X-rays with XTE on July 25 1997 with a rather soft X-ray spectrum and its outburst was monitored in soft X-rays up to November 1997. On September 16 it was first detected in hard X-rays by the French soft gamma ray telescope SIGMA during a Galactic Center observation. The flux was stronger on September 16 and 17 reaching a level of about 110 mCrab in the 40-80 keV energy band. On the same days the photon index of the spectrum was determined to be alpha =-2.3 +/- 0.9 (1 sigma error) while the 40-150 keV luminosity was about 8 x 10^{36} erg/s for a distance of 8.5 kpc. SIGMA and XTE results on this source indicate that this source had an ultrasoft-like state during its main outburst and a harder secondary outburst in September. These characteristics make the source similar to X-Nova Muscae 1991, a well known black hole candidate.
[5]  oai:arXiv.org:astro-ph/9709089  [pdf] - 98542
SIGMA observations of X-ray Nova Velorum 1993 (GRS 1009-45)
Comments: 4 pages LaTeX, 2 postscript figures, Accepted by Astronomy and AstroPhysics
Submitted: 1997-09-10
We report on hard X-ray observations of X-ray Nova Velorum 1993 (GRS 1009-45) performed with the SIGMA coded mask X-ray telescope in January 1994. The source was clearly detected with a flux of about 60 mCrab in the 40-150 keV energy band during the two observations with a hard spectrum (alpha ~ - 1.9) extending up to ~ 150 keV. These observations confirm the duration of the activity of the source in hard X-rays over 100 days after the first maximum and suggest a spectral hardening which has already been observed in Nova Muscae. These and other characteristics found in these observations strengthen the case for this Nova to be a black hole candidate similar to Nova Muscae.
[6]  oai:arXiv.org:astro-ph/9708270  [pdf] - 1235087
Properties Of The Hard X-ray Radiation From The Black Hole Candidates: Cygnus X-1 And 1E1740.7-2942
Comments: 6 pages, 7 figures, uses mn.sty, epsf.sty, psfig.tex; Accepted for publication in MNRAS; Also available at http://hea.iki.rssi.ru/~sik/PAPERS/mnras97.ps.gz (gzipped PostScript)
Submitted: 1997-08-29
The entire dataset of the GRANAT/SIGMA observations of Cyg X-1 and 1E1740.7-2942 in 1990-1994 was analyzed in order to search for correlations between primary observational characteristics of the hard X-ray (40-200 keV) emission - hard X-ray luminosity, hardness of the spectrum (quantified in terms of the best-fit thermal bremsstrahlung temperature kT) and the RMS of short-term flux variations. Although no strict point-to-point correlations were detected certain general tendencies are evident. It was found that for Cyg X-1 the spectral hardness is in general positively correlated with relative amplitude of short-term variability. The correlation of similar kind was found for X-ray transient GRO J0422+32 (X-ray Nova Persei 1992). For both sources an approximate correlation between kT and L_X was found. At low hard X-ray luminosity - below 10E37 erg/sec - kT increases with L_X. At higher luminosity the spectral hardness depends weaker or does not depend at all on the hard X-ray luminosity. The low luminosity end of these approximate correlations (low kT and low RMS) corresponds to extended episodes of very low hard X-ray flux occurred during SIGMA observations.
[7]  oai:arXiv.org:astro-ph/9704266  [pdf] - 97228
Properties Of The Hard X-ray Emission From The Black Hole Candidates: Cygnus X-1 And 1E1740.7-2942
Comments: 4 pages, 6 figures, uses esa_sp_latex.sty esa_sp_latex.tex, Proceedings 2nd INTEGRAL Workshop "The Transparent Universe", St. Malo, France, 16-20 September 1996. Also available at http://hea.iki.rssi.ru/~sik/PAPERS/proc96.ps.gz (gzipped PostScript)
Submitted: 1997-04-28
The entire dataset of the GRANAT/SIGMA observations of Cyg X-1 and 1E1740.7-2942 in 1990-1994 was analyzed in order to search for correlations between primary observational characteristics of the hard X-ray (40-200 keV) emission - hard X-ray luminosity, hardness of the spectrum (quantified in terms of the best-fit thermal bremsstrahlung temperature kT) and the RMS of short-term flux variations. Although no strict point-to-point correlations were detected certain general tendencies are evident. It was found that for Cyg X-1 the spectral hardness is in general positively correlated with relative amplitude of short-term variability. The correlation of similar kind was found for X-ray transient GRO J0422+32 (X-ray Nova Persei 1992) and recently for GX339-4. For both sources approximate correlation between kT and L_X was found. At low hard X-ray luminosity - below 10E37 erg/sec - the kT increases with increase of L_X. At higher luminosity the spectral hardness depends weaker or does not depend at all on the hard X-ray luminosity. The low luminosity end of these approximate correlations (low kT and low RMS) corresponds to extended episodes of very low hard X-ray flux occurred for both sources during SIGMA observations.
[8]  oai:arXiv.org:astro-ph/9603118  [pdf] - 1943583
Two Distinct Modes In The Low (Hard) State Of Cyg X-1 And 1E1740-294
Comments: 2 pages, 2 figures, uses proceeding.sty psfig.sty, to appear in Proc. Conf. "Roentgenstrahlung from the Universe", Wuerzburg, Germany, September 25-29, 1995. Also available at http://hea.iki.rssi.ru/~sik/PAPERS/proceed.ps.gz (gzipped PostScript)
Submitted: 1996-03-21
The entire dataset of the GRANAT/SIGMA observations of Cyg X-1 and 1E1740.7-294 in 1990-1994 was analyzed in order to search for correlations between primary observational characteristics of the hard X-ray emission - hard X-ray luminosity L_X, hardness of the spectrum (quantified in terms of the best fit thermal bremsstrahlung temperature kT) and the RMS of short term flux variations. Two distinct modes of the kT vs. L_X dependence were found for both sources. At low luminosity - below the level corresponding approximately to the gamma_1 state of Cyg X-1 - the kT increases as the L_X increases. Above the luminosity level of ~1.2L_gamma_1 the spectrum hardness is nearly constant (kT ~150 keV) and does not depend on the luminosity. In the case of Cyg X-1 the correlation of similar kind was found between the spectrum hardness and RMS of the short term flux variations. The increase of the kT, corresponding to the increasing branch on the kT vs. L_X diagram, is accompanied with increase of the RMS from few percent level to ~10-15%. Further increase of the RMS is not accompanied with change of the kT and does not correlate with changes in the luminosity.