Normalized to: Dushkin, A.
[2]
oai:arXiv.org:1109.3270 [pdf] - 1084108
Dark Matter Time Projection Chamber: Recent R&D Results
Battat, J. B. R.;
Ahlen, S.;
Chernicoff, M.;
Deaconu, C.;
Dujmic, D.;
Dushkin, A.;
Fisher, P.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kirsch, L.;
Lopez, J. P.;
Monroe, J.;
Ouyang, H.;
Sciolla, G.;
Tomita, H.;
Wellenstein, H.
Submitted: 2011-09-15, last modified: 2011-09-18
The Dark Matter Time Projection Chamber collaboration recently reported a
dark matter limit obtained with a 10 liter time projection chamber filled with
CF4 gas. The 10 liter detector was capable of 2D tracking (perpendicular to the
drift direction) and 2D fiducialization, and only used information from two CCD
cameras when identifying tracks and rejecting backgrounds. Since that time, the
collaboration has explored the potential benefits of photomultiplier tube and
electronic charge readout to achieve 3D tracking, and particle identification
for background rejection. The latest results of this effort is described here.
[3]
oai:arXiv.org:1109.3501 [pdf] - 1084146
Background Rejection in the DMTPC Dark Matter Search Using Charge
Signals
Lopez, J. P.;
Ahlen, S.;
Battat, J.;
Caldwell, T.;
Chernicoff, M.;
Deaconu, C.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Fisher, P.;
Golub, F.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kohse, G.;
Kirsch, L.;
Lanza, R.;
Lee, A.;
Monroe, J.;
Ouyang, H.;
Sahin, T.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R.;
Yegoryan, H.
Submitted: 2011-09-15
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing
low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical
readout with CCD cameras allows for the detection for the daily modulation in
the direction of the dark matter wind, while several charge readout channels
allow for the measurement of additional recoil properties. In this article, we
show that the addition of the charge readout analysis to the CCD allows us too
obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor
of $5.6\times10^{-6}$ for recoils with energies between 40 and 200
keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals
and light in the CCD reduces CCD-specific backgrounds by more than two orders
of magnitude.
[4]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[5]
oai:arXiv.org:0907.0675 [pdf] - 151008
DMTPC: A dark matter detector with directional sensitivity
Battat, J. B. R.;
Ahlen, S.;
Caldwell, T.;
Dujmic, D.;
Dushkin, A.;
Fisher, P.;
Golub, F.;
Goyal, S.;
Henderson, S.;
Inglis, A.;
Lanza, R.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sciolla, G.;
Skvorodnev, B. N.;
Tomita, H.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2009-07-03
By correlating nuclear recoil directions with the Earth's direction of motion
through the Galaxy, a directional dark matter detector can unambiguously detect
Weakly Interacting Massive Particles (WIMPs), even in the presence of
backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC)
detector, a TPC filled with CF4 gas at low pressure (0.1 atm). Using this
detector, we have measured the vector direction (head-tail) of nuclear recoils
down to energies of 100 keV with an angular resolution of <15 degrees. To study
our detector backgrounds, we have operated in a basement laboratory on the MIT
campus for several months. We are currently building a new, high-radiopurity
detector for deployment underground at the Waste Isolation Pilot Plant facility
in New Mexico.
[6]
oai:arXiv.org:0903.3895 [pdf] - 22632
The DMTPC project
Sciolla, G.;
Battat, J.;
Caldwell, T.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Sciolla, G.;
Yamamoto, R.;
Yegoryan, H.;
Ahlen, S.;
Otis, K.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2009-03-23
The DMTPC detector is a low-pressure CF4 TPC with optical readout for
directional detection of Dark Matter. The combination of the energy and
directional tracking information allows for an efficient suppression of all
backgrounds. The choice of gas (CF4) makes this detector particularly sensitive
to spin-dependent interactions.
[7]
oai:arXiv.org:0811.2922 [pdf] - 121221
The DMTPC detector
Sciolla, G.;
Battat, J.;
Caldwell, T.;
Cornell, B.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Vanderspek, R.;
Yamamoto, R.;
Yegoryan, H.;
Ahlen, S.;
Avery, D.;
Otis, K.;
Roccaro, A.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2008-11-18
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.
[8]
oai:arXiv.org:0810.0291 [pdf] - 16990
DMTPC: a new apparatus for directional detection of Dark Matter
Sciolla, G.;
Lee, A.;
Battat, J.;
Caldwell, T.;
Cornell, B.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Vanderspek, R .;
Yamamoto, R.;
Yegoryan, H.;
Alhen, S.;
Avery, D.;
Otis, K.;
Roccaro, A.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2008-10-01
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.