sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Dupuis, O.

Normalized to: Dupuis, O.

7 article(s) in total. 213 co-authors, from 1 to 7 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:2001.06114  [pdf] - 2061667
A Family of Phase Masks For Broadband Coronagraphy Example of the Wrapped Vortex Phase Mask Theory and Laboratory demonstration
Comments: 11 pages, 17 figures, accepted in Astronomy & Astrophysics
Submitted: 2020-01-16
Future instruments need efficient coronagraphs over large spectral ranges to enable broadband imaging or spectral characterization of exoplanets 1e8 fainter than their star. Several solutions were proposed. Pupil apodizers can attenuate the star intensity by a 1e10 factor but they transmit a few percents of the planet light only. Cascades of phase/amplitude masks can both attenuate the starlight and transmit most of the planet light but the number of optics to align is not a practical solution for an instrument. Finally, vector phase masks can be used to detect faint sources close to bright stars but they require the use of high quality circular polarizers and as for the previous solution, this leads to a complex instrument with numerous optics to align and stabilize. We propose simple coronagraphs that need one scalar phase mask and one binary Lyot stop only providing high transmission for the planet light (>50%) and high attenuation of the starlight over a large spectral bandpass (~30%) and a 360 degree field-of-view. From mathematical considerations, we find a family of 2D-phase masks optimized for an unobscured pupil. One mask is an azimuthal wrapped vortex phase ramp. We probe its coronagraphic performance using numerical simulations and laboratory tests. From numerical simulations, we predict the wrapped vortex can attenuate the peak of the star image by a factor of 1e4 over a 29% bandpass and 1e5 over a 18% bandpass with transmission of more than 50% of the planet flux at ~4 lambda/D. We confirm these predictions in laboratory in visible light between 550nm and 870nm. We also obtain laboratory dark hole images in which exoplanets with fluxes that are 3e-8 times the host star flux could be detected at 3sigma. Taking advantage of a new technology for etching continuous 2D-functions, new type of masks can be easily manufactured opening new possibilities for broadband coronagraphy.
[2]  oai:arXiv.org:1902.04080  [pdf] - 1996682
SPHERE: the exoplanet imager for the Very Large Telescope
Comments: Final version accepted for publication in A&A
Submitted: 2019-02-11, last modified: 2019-10-03
Observations of circumstellar environments to look for the direct signal of exoplanets and the scattered light from disks has significant instrumental implications. In the past 15 years, major developments in adaptive optics, coronagraphy, optical manufacturing, wavefront sensing and data processing, together with a consistent global system analysis have enabled a new generation of high-contrast imagers and spectrographs on large ground-based telescopes with much better performance. One of the most productive is the Spectro-Polarimetic High contrast imager for Exoplanets REsearch (SPHERE) designed and built for the ESO Very Large Telescope (VLT) in Chile. SPHERE includes an extreme adaptive optics system, a highly stable common path interface, several types of coronagraphs and three science instruments. Two of them, the Integral Field Spectrograph (IFS) and the Infra-Red Dual-band Imager and Spectrograph (IRDIS), are designed to efficiently cover the near-infrared (NIR) range in a single observation for efficient young planet search. The third one, ZIMPOL, is designed for visible (VIR) polarimetric observation to look for the reflected light of exoplanets and the light scattered by debris disks. This suite of three science instruments enables to study circumstellar environments at unprecedented angular resolution both in the visible and the near-infrared. In this work, we present the complete instrument and its on-sky performance after 4 years of operations at the VLT.
[3]  oai:arXiv.org:1910.00573  [pdf] - 1994276
Active minimization of non-common path aberrations in long-exposure imaging of exoplanetary systems
Comments: 10 pages, 11 figures, accepted for publication to A&A
Submitted: 2019-10-01
Context. Spectroscopy of exoplanets is very challenging because of the high star-planet contrast. A technical difficulty in the design of imaging instruments is the noncommon path aberrations (NCPAs) between the adaptive optics (AO) sensing and the science camera, which induce planet-resembling stellar speckles in the coronagraphic science images. In an observing sequence of several long exposures, quickly evolving NCPAs average out and leave behind an AO halo that adds photon noise to the planet detection. Static NCPA can be calibrated a posteriori using differential imaging techniques. However, NCPAs that evolve during the observing sequence do not average out and cannot be calibrated a posteriori. These quasi-static NCPAs are one of the main limitations of the current direct imaging instruments such as SPHERE, GPI, and SCExAO. Aims. Our aim is to actively minimize the quasi-static speckles induced in long-exposure images. To do so, we need to measure the quasi-static speckle field above the AO halo. Methods. The self-coherent camera (SCC) is a proven technique which measures the speckle complex field in the coronagraphic science images. It is routinely used on the THD2 bench to reach contrast levels of <10^{-8} in the range 5-12 {\lambda}/D in space-related conditions. To test the SCC in ground conditions on THD2, we optically simulated the residual aberrations measured behind the SPHERE/VLT AO system under good observing conditions. Results. We demonstrate in the laboratory that the SCC can minimize the quasi-static speckle intensity in the science images down to a limitation set by the AO halo residuals. The SCC reaches 1{\sigma} raw contrast levels below 10^{-6} in the region 5-12 {\lambda}/D at 783.25 nm in our experiments.
[4]  oai:arXiv.org:1807.10003  [pdf] - 1723038
The MICADO first light imager for the ELT: overview, operation, simulation
Davies, Richard; Alves, João; Clénet, Yann; Lang-Bardl, Florian; Nicklas, Harald; Pott, Jörg-Uwe; Ragazzoni, Roberto; Tolstoy, Eline; Amico, Paola; Anwand-Heerwart, Heiko; Barboza, Santiago; Barl, Lothar; Baudoz, Pierre; Bender, Ralf; Bezawada, Naidu; Bizenberger, Peter; Boland, Wilfried; Bonifacio, Piercarlo; Borgo, Bruno; Buey, Tristan; Chapron, Frédéric; Chemla, Fanny; Cohen, Mathieu; Czoske, Oliver; Deo, Vincent; Disseau, Karen; Dreizler, Stefan; Dupuis, Olivier; Fabricius, Maximilian; Falomo, Renato; Fedou, Pierre; Schreiber, Natascha Foerster; Garrel, Vincent; Geis, Norbert; Gemperlein, Hans; Gendron, Eric; Genzel, Reinhard; Gillessen, Stefan; Glück, Martin; Grupp, Frank; Hartl, Michael; Häuser, Marco; Hess, Hans-Joachim; Hofferbert, Ralf; Hopp, Ulrich; Hörmann, Veronika; Hubert, Zoltan; Huby, Elsa; Huet, Jean-Michel; Hutterer, Victoria; Ives, Derek; Janssen, Annemieke; Jellema, Willem; Kausch, Wolfgang; Kerber, Florian; Kravcar, Helmut; Ruyet, Bertrand Le; Leschinski, Kieran; Mandla, Christopher; Manhart, Markus; Massari, Davide; Mei, Simona; Merlin, Frédéric; Mohr, Lars; Monna, Anna; Muench, Norbert; Mueller, Friedrich; Musters, Gert; Navarro, Ramon; Neumann, Udo; Neumayer, Nadine; Niebsch, Jenny; Plattner, Markus; Przybilla, Norbert; Rabien, Sebastian; Ramlau, Ronny; Ramos, José; Ramsay, Suzanne; Rhode, Petra; Richter, Amon; Richter, Josef; Rix, Hans-Walter; Rodeghiero, Gabriele; Rohloff, Ralf-Rainer; Rosensteiner, Matthias; Rousset, Gérard; Schlichter, Jörg; Schubert, Josef; Sevin, Arnaud; Stuik, Remko; Sturm, Eckhard; Thomas, Jens; Tromp, Niels; Kleijn, Gijs Verdoes; Vidal, Fabrice; Wagner, Roland; Wegner, Michael; Zeilinger, Werner; Ziegleder, Julian; Ziegler, Bodo; Zins, Gérard
Comments: Proc SPIE 10702. SPIE's copyright notice: "Copyright 2018 Society of PhotoOptical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited."
Submitted: 2018-07-26
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and making use of the data simulation tool, an outline is presented of what we can expect the instrument to achieve.
[5]  oai:arXiv.org:1801.06600  [pdf] - 1621551
Status and performance of the THD2 bench in multi-deformable mirror configuration
Comments: 9 pages, 5 figures, 1 Table, AO4ELT 2017 conference proceeding
Submitted: 2018-01-19
The architecture of exoplanetary systems is relatively well known inward to 1 AU thanks to indirect techniques, which have allowed characterization of thousands of exoplanet orbits, masses and sometimes radii. The next step is the characterization of exoplanet atmospheres at long period, which requires direct imaging capability. While the characterization of a handful of young giant planets is feasible with dedicated instruments like SPHERE/VLT, GPI/Gemini, SCExAO/Subaru and soon with the coronagraphic capabilities aboard JWST, the spectroscopic study of mature giant planets and lower mass planets (Neptune-like, Super Earths) requires the achievement of better coronagraphic performance. While space-based coronagraph on WFIRST-AFTA might start this study at low spectroscopic resolution, dedicated projects on large space telescope and on the ELT will be required for a more complete spectroscopic study of these faint planets. To prepare these future instruments, we developed a high contrast imaging bench called THD, then THD2 for the upgraded version using multi-DM configuration. The THD2 bench is designed to test and compare coronagraphs as well as focal plane wavefront sensors and wavefront control techniques. It can simulate the beam provided by a space telescope and soon the first stage of adaptive optics behind a ground-based telescope. In this article, we describe in details the THD2 bench and give the results of a recent comparison study of the chromatic behavior for several coronagraph on the THD2.
[6]  oai:arXiv.org:1605.08523  [pdf] - 1451912
Laboratory validation of the dual-zone phase mask coronagraph in broadband light at the high-contrast imaging THD-testbed
Comments: 9 pages, 16 figures
Submitted: 2016-05-27
Specific high contrast imaging instruments are mandatory to characterize circumstellar disks and exoplanets around nearby stars. Coronagraphs are commonly used in these facilities to reject the diffracted light of an observed star and enable the direct imaging and spectroscopy of its circumstellar environment. One important property of the coronagraph is to be able to work in broadband light. Among several proposed coronagraphs, the dual-zone phase mask coronagraph is a promising solution for starlight rejection in broadband light. In this paper, we perform the first validation of this concept in laboratory. First, we recall the principle of the dual-zone phase mask coronagraph. Then, we describe the high-contrast imaging THD testbed, the manufacturing of the components and the quality-control procedures. Finally, we study the sensitivity of our coronagraph to low-order aberrations (inner working angle and defocus) and estimate its contrast performance. Our experimental broadband light results are compared with numerical simulations to check agreement with the performance predictions. With the manufactured prototype and using a dark hole technique based on the self-coherent camera, we obtain contrast levels down to $2\,10^{-8}$ between 5 and 17$\,\lambda_0/D$ in monochromatic light (640 nm). We also reach contrast levels of $4\,10^{-8}$ between 7 and 17$\lambda_0/D$ in broadband ($\lambda_0=675$ nm, $\Delta\lambda=250$ nm and $\Delta\lambda / \lambda_0 = 40$ %), which demonstrates the excellent chromatic performance of the dual-zone phase mask coronagraph. The performance reached by the dual-zone phase mask coronagraph is promising for future high-contrast imaging instruments that aim at detecting and spectrally characterizing old or light gaseous planets.
[7]  oai:arXiv.org:1601.07748  [pdf] - 1385462
Focal plane wavefront sensor achromatization : The multireference self-coherent camera
Comments: 14 pages, 20 figures
Submitted: 2016-01-28
High contrast imaging and spectroscopy provide unique constraints for exoplanet formation models as well as for planetary atmosphere models. But this can be challenging because of the planet-to-star small angular separation and high flux ratio. Recently, optimized instruments like SPHERE and GPI were installed on 8m-class telescopes. These will probe young gazeous exoplanets at large separations (~1au) but, because of uncalibrated aberrations that induce speckles in the coronagraphic images, they are not able to detect older and fainter planets. There are always aberrations that are slowly evolving in time. They create quasi-static speckles that cannot be calibrated a posteriori with sufficient accuracy. An active correction of these speckles is thus needed to reach very high contrast levels (>1e7). This requires a focal plane wavefront sensor. Our team proposed the SCC, the performance of which was demonstrated in the laboratory. As for all focal plane wavefront sensors, these are sensitive to chromatism and we propose an upgrade that mitigates the chromatism effects. First, we recall the principle of the SCC and we explain its limitations in polychromatic light. Then, we present and numerically study two upgrades to mitigate chromatism effects: the optical path difference method and the multireference self-coherent camera. Finally, we present laboratory tests of the latter solution. We demonstrate in the laboratory that the MRSCC camera can be used as a focal plane wavefront sensor in polychromatic light using an 80 nm bandwidth at 640 nm. We reach a performance that is close to the chromatic limitations of our bench: contrast of 4.5e-8 between 5 and 17 lambda/D. The performance of the MRSCC is promising for future high-contrast imaging instruments that aim to actively minimize the speckle intensity so as to detect and spectrally characterize faint old or light gaseous planets.