oai:arXiv.org:astro-ph/0211584 [pdf] - 53319
On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon
Flight
Curioni, A.;
Aprile, E.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-26, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray
astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC),
sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position
sensitive detector, gamma rays with at least two interactions in the sensitive
volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope.
Gamma-rays with a single interaction cannot be imaged and constitute a
background which can be easily identified and rejected. Charged particles and
localized beta-particles background is also easily suppressed based on the TPC
localization capability with millimeter resolution. A measurement of the total
gamma-ray background rate in near space conditions and the background rejection
power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program.
We present here a preliminary analysis addressing this question, based on
balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight
from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the
LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield.
Single site events and charged particles were mostly rejected on-line at the
first and second trigger level. The remaining count rate of single-site \g-ray
events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with
that expected from atmospheric and diffuse gamma-ray background, taking into
account the instrument mass model and response.
[2]
oai:arXiv.org:astro-ph/0212005 [pdf] - 53395
The LXeGRIT Compton Telescope Prototype: Current Status and Future
Prospects
Aprile, E.;
Curioni, A.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-30, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel concept of Compton telescope, based
on the complete 3-dimensional reconstruction of the sequence of interactions of
individual gamma rays in one position sensitive detector. This balloon-borne
telescope consists of an unshielded time projection chamber with an active
volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV
PMTs detect the fast xenon scintillation light signal, providing the event
trigger. 124 wires and 4 anodes detect the ionization signals, providing the
event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT
has been extensively tested both in the laboratory and at balloon altitude, and
its response in the MeV region has been thoroughly characterized. Here we
summarize some of the results on pre-flight calibration, event reconstruction
techniques, and performance during a 27 hour balloon flight on October 4 -- 5.
We further present briefly the on-going efforts directed to improve the
performance of this prototype towards the requirements for a base module of a
next-generation Compton telescope.
[3]
oai:arXiv.org:astro-ph/0012398 [pdf] - 1232610
Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon
Gamma-Ray Imaging Telescope (LXeGRIT)
Aprile, E.;
Oberlack, U. G.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid
xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is
designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an
angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a
field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional
spatial resolution as measured during pre-flight calibration experiments, are
$\Delta E_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively.
The detection efficiency for Compton events varies between 1.5% and 4%
depending on energy and event selection. We describe the instrument as flown on
May 7, 1999 and review its overall performance at balloon altitude. The launch
occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was
terminated about 9 hours later. The Crab was in the instrument FOV for a few
hours. Analysis of these data is in progress.
[4]
oai:arXiv.org:astro-ph/0012297 [pdf] - 1232606
Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray
Imaging Telescope (LXeGRIT)
Aprile, E.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Oberlack, U. G.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-13
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time
projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of
0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled
with high purity LXe. Both ionization and scintillation light signals are
detected to measure the energy deposits and the three spatial coordinates of
individual \g -ray interactions within the sensitive volume. The TPC has been
characterized with repeated measurements of its spectral and Compton imaging
response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be.
The detector shows a linear response to \g -rays in the energy range 511 keV
-4.4 MeV, with an energy resolution (FWHM) of $ \Delta E/E=8.8% \: \sqrt{1\MeV
/E}$. Compton imaging of \yt \g -ray events with two detected interactions is
consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.