sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Drukier, Andrzej

Normalized to: Drukier, A.

7 article(s) in total. 18 co-authors, from 1 to 7 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1906.05800  [pdf] - 2094552
Paleo-Detectors for Galactic Supernova Neutrinos
Comments: 15 pages, 5 figures. code available at https://github.com/tedwards2412/SN-paleology (archived at https://doi.org/10.5281/zenodo.3066206 ) v2: matches the published version
Submitted: 2019-06-13, last modified: 2020-05-13
Paleo-detectors are a proposed experimental technique in which one would search for traces of recoiling nuclei in ancient minerals. Natural minerals on Earth are as old as $\mathcal{O}(1)\,$Gyr and, in many minerals, the damage tracks left by recoiling nuclei are also preserved for timescales long compared to 1 Gyr once created. Thus, even reading out relatively small target samples of order 100 g, paleo-detectors would allow one to search for very rare events thanks to the large exposure, $\varepsilon \sim 100\,{\rm g}\,{\rm Gyr} = 10^5\,{\rm t}\,{\rm yr}$. Here, we explore the potential of paleo-detectors to measure nuclear recoils induced by neutrinos from galactic core collapse supernovae. We find that they would not only allow for a direct measurement of the average core collapse supernova rate in the Milky Way, but would also contain information about the time-dependence of the local supernova rate over the past $\sim$1 Gyr. Since the supernova rate is thought to be directly proportional to the star formation rate, such a measurement would provide a determination of the local star formation history. We investigate the sensitivity of paleo-detectors to both a smooth time evolution and an enhancement of the core collapse supernova rate on relatively short timescales, as would be expected for a starburst period in the local group.
[2]  oai:arXiv.org:1806.05991  [pdf] - 2055753
Searching for Dark Matter with Paleo-Detectors
Comments: 6 pages, 2 figures. v2: significant revisions. v3: matches the published version
Submitted: 2018-06-15, last modified: 2020-02-26
A large experimental program is underway to extend the sensitivity of direct detection experiments, searching for interaction of Dark Matter with nuclei, down to the neutrino floor. However, such experiments are becoming increasingly difficult and costly due to the large target masses and exquisite background rejection needed for the necessary improvements in sensitivity. We investigate an alternative approach to the detection of Dark Matter-nucleon interactions: Searching for the persistent traces left by Dark Matter scattering in ancient minerals obtained from much deeper than current underground laboratories. We estimate the sensitivity of paleo-detectors, which extends far beyond current upper limits for a wide range of Dark Matter masses. The sensitivity of our proposal also far exceeds the upper limits set by Snowden-Ifft et al. more than three decades ago using ancient Mica in an approach similar to paleo-detectors.
[3]  oai:arXiv.org:1811.10549  [pdf] - 1855664
Digging for Dark Matter: Spectral Analysis and Discovery Potential of Paleo-Detectors
Comments: 14 pages, 5 figures, code available at https://github.com/tedwards2412/paleo_detectors/ . v2: Added additional analysis theory details, matches version published in PRD
Submitted: 2018-11-26, last modified: 2019-03-26
Paleo-detectors are a recently proposed method for the direct detection of Dark Matter (DM). In such detectors, one would search for the persistent damage features left by DM--nucleus interactions in ancient minerals. Initial sensitivity projections have shown that paleo-detectors could probe much of the remaining Weakly Interacting Massive Particle (WIMP) parameter space. In this paper, we improve upon the cut-and-count approach previously used to estimate the sensitivity by performing a full spectral analysis of the background- and DM-induced signal spectra. We consider two scenarios for the systematic errors on the background spectra: i) systematic errors on the normalization only, and ii) systematic errors on the shape of the backgrounds. We find that the projected sensitivity is rather robust to imperfect knowledge of the backgrounds. Finally, we study how well the parameters of the true WIMP model could be reconstructed in the hypothetical case of a WIMP discovery.
[4]  oai:arXiv.org:1811.06844  [pdf] - 1839654
Paleo-detectors: Searching for Dark Matter with Ancient Minerals
Comments: 22 pages, 7 figures, 1 table. v2: matches the published version
Submitted: 2018-11-16, last modified: 2019-02-27
We explore paleo-detectors as an approach to the direct detection of Weakly Interacting Massive Particle (WIMP) dark matter radically different from conventional detectors. Instead of instrumenting a (large) target mass in a laboratory in order to observe WIMP-induced nuclear recoils in real time, the approach is to examine ancient minerals for traces of WIMP-nucleus interactions recorded over timescales as large as 1 Gyr. Here, we discuss the paleo-detector proposal in detail, including background sources and possible target materials. In order to suppress backgrounds induced by radioactive contaminants such as uranium, we propose to use minerals found in marine evaporites or in ultra-basic rocks. We estimate the sensitivity of paleo-detectors to spin-independent and spin-dependent WIMP-nucleus interactions. The sensitivity to low-mass WIMPs with masses $m_\chi \lesssim 10$ GeV extends to WIMP-nucleon cross sections many orders of magnitude smaller than current upper limits. For heavier WIMPs with masses $m_\chi \gtrsim 30$ GeV cross sections a factor of a few to $\sim 100$ smaller than current upper limits can be probed by paleo-detectors.
[5]  oai:arXiv.org:1403.8154  [pdf] - 1240857
New class of biological detectors for WIMPs
Comments: 29 pages
Submitted: 2014-03-31, last modified: 2015-07-02
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP masses of approximately 10 GeV/c2. However, for MDM > 10 GeV/c2 null results of the CDMS-Ge, XENON, and LUX detectors may be in tension with the potential detections for certain dark matter scenarios and assuming a certain light response. We propose the use of a new class of biological dark matter (DM) detectors to further examine this light dark matter hypothesis, taking advantage of new signatures with low atomic number targets, Two types of biological DM detectors are discussed here: DNA-based detectors and enzymatic reactions (ER) based detectors. In the case of DNA-based detectors, we discuss a new implementation. In the case of ER detectors, there are four crucial phases of the detection process: a) change of state due to energy deposited by a particle; b) amplification due to the release of energy derived from the action of an enzyme on its substrate; c) sustainable but non-explosive enzymatic reaction; d) self-termination due to the denaturation of the enzyme, when the temperature is raised. This paper provides information of how to design as well as optimize these four processes.
[6]  oai:arXiv.org:1206.6809  [pdf] - 919817
New Dark Matter Detectors using DNA or RNA for Nanometer Tracking
Comments: 18 pages, 2 figures
Submitted: 2012-06-28, last modified: 2015-01-11
Weakly Interacting Massive Particles (WIMPs) may constitute most of the matter in the Universe. The ability to detect the directionality of recoil nuclei will considerably facilitate detection of WIMPs. In this paper we propose a novel type of dark matter detector: detectors made of DNA or RNA could provide nanometer resolution for tracking, an energy threshold of 0.5 keV, and can operate at room temperature. When a WIMP from the Galactic Halo elastically scatters off of a nucleus in the detector, the recoiling nucleus then traverses hundreds of strings of single stranded nucleic acids (ssNA) with known base sequences and severs ssNA strands along its trajectory. The location of the break can be identified by amplifying and identifying the segments of cut ssNA using techniques well known to biologists. Thus the path of the recoiling nucleus can be tracked to nanometer accuracy. In one such detector concept, the transducers are nanometer-thick Au-foils of 1m x 1m, and the direction of recoiling nuclei is measured by "NA Tracking Chamber" consisting of ordered array of ssNA strands. Polymerase Chain Reaction (PCR) and ssNA sequencing are used to read-out the detector. The proposed detector is smaller and cheaper than other alternatives: 1 kg of gold and 0.1 to 4 kg of ssNA (depending on length and strand density), packed into 0.01m$^3$, can be used to study 10 GeV WIMPs. A variety of other detector target elements could be used in this detector to optimize for different WIMP masses and to identify WIMP properties. By leveraging advances in molecular biology, we aim to achieve about 1,000-fold better spatial resolution than in conventional WIMP detectors at reasonable cost.
[7]  oai:arXiv.org:1403.8115  [pdf] - 809834
New Dark Matter Detector using Nanoscale Explosives
Comments: 26 pager, 3 figures
Submitted: 2014-03-31, last modified: 2014-04-14
We present nanoscale explosives as a novel type of dark matter detector and study the ignition properties. When a Weakly Interacting Massive Particle WIMP from the Galactic Halo elastically scatters off of a nucleus in the detector, the small amount of energy deposited can trigger an explosion. For specificity, this paper focuses on a type of two-component explosive known as a nanothermite, consisting of a metal and an oxide in close proximity. When the two components interact they undergo a rapid exothermic reaction --- an explosion. As a specific example, we consider metal nanoparticles of 5 nm radius embedded in an oxide. One cell contains more than a few million nanoparticles, and a large number of cells adds up to a total of 1 kg detector mass. A WIMP interacts with a metal nucleus of the nanoparticles, depositing enough energy to initiate a reaction at the interface between the two layers. When one nanoparticle explodes it initiates a chain reaction throughout the cell. A number of possible thermite materials are studied. Excellent background rejection can be achieved because of the nanoscale granularity of the detector: whereas a WIMP will cause a single cell to explode, backgrounds will instead set off multiple cells. If the detector operates at room temperature, we find that WIMPs with masses above 100 GeV (or for some materials above 1 TeV) could be detected; they deposit enough energy ($>$10 keV) to cause an explosion. When operating cryogenically at liquid nitrogen or liquid helium temperatures, the nano explosive WIMP detector can detect energy deposits as low as 0.5 keV, making the nano explosive detector more sensitive to very light $<$10 GeV WIMPs, better than other dark matter detectors.