Normalized to: Drain, D.
[1]
oai:arXiv.org:astro-ph/0503265 [pdf] - 71647
Final results of the EDELWEISS-I dark matter search with cryogenic
heat-and-ionization Ge detectors
Sanglard, V.;
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chabert, L.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Collin, S.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Drain, D.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Herve, S.;
Horn, M.;
Juillard, A.;
Karolak, M.;
Kikuchi, C.;
de Lesquen, A.;
Luca, M.;
Mallet, J.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Schoeffel, L.;
Stern, M.;
Vagneron, L.;
Villar, V.
Submitted: 2005-03-11, last modified: 2005-05-26
The final results of the EDELWEISS-I dark matter search using cryogenic
heat-and-ionization Ge detectors are presented. The final data sample
corresponds to an increase by a factor five in exposure relative to the
previously published results. A recoil energy threshold of 13 keV or better was
achieved with three 320g detectors working simultaneously over four months of
stable operation. Limits on the spin-independent cross-section for the
scattering of a WIMP on a nucleon are derived from an accumulated fiducial
exposure of 62 kg.d.
[2]
oai:arXiv.org:astro-ph/0412061 [pdf] - 69465
Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions
Benoit, A.;
Berge, L.;
Bluemer, J.;
Broniatowski, A.;
Censier, B.;
Chabert, L.;
Chapellier, M.;
Chardin, G.;
Collin, S.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Drain, D.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Gros, M.;
Gumbsheimer, R.;
Horn, M.;
Juillard, A.;
De Lesquen, A.;
Luca, M.;
Mallet, J.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Razeti, M.;
Sanglard, V.;
Schoeffel, L.;
Stern, M.;
Villar, V.
Submitted: 2004-12-02, last modified: 2005-04-19
The EDELWEISS collaboration is searching for WIMP dark matter using natural
Ge cryogenic detectors. The whole data set of the first phase of the experiment
contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present
(7.8%), high-spin Ge isotope. The sensitivity of the experiment to the
spin-dependent WIMP-nucleon interactions is evaluated using the
model-independent framework proposed by Tovey et al.
[3]
oai:arXiv.org:astro-ph/0310657 [pdf] - 60320
Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium
Detectors for Dark Matter Search
The EDELWEISS Collaboration;
Martineau, O.;
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chabert, L.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Riccio, C.;
Sanglard, V.;
Schoeffel, L.;
Stern, M.;
Vagneron, L.
Submitted: 2003-10-22
Several aspects of the analysis of the data obtained with the cryogenic
heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search
experiment are presented. Their calibration, the determination of their energy
threshold, fiducial volume and nuclear recoil acceptance are detailed.
[4]
oai:arXiv.org:astro-ph/0212491 [pdf] - 53881
SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching
Factors using Monoenergetic Neutron Beam
Simon, E.;
Berge, L.;
Broniatowski, A.;
Bouvier, R.;
Chambon, B.;
De Jesus, M.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Hadjout, J. P.;
Juillard, A.;
Martineau, O.;
Pastor, C.;
Stern, M.;
Vagneron, L.
Submitted: 2002-12-20
SICANE is a neutron scattering multidetector facility for the determination
of the quenching factor (ratio of the response to nuclear recoils and to
electrons) of cryogenic detectors used in direct WIMP searches. Well collimated
monoenergetic neutron beams are obtained with inverse (p,n) reactions. The
facility is described, and results obtained for the quenching factors of
scintillation in NaI(Tl) and of heat and ionization in Ge are presented.
[5]
oai:arXiv.org:astro-ph/0206271 [pdf] - 49902
Improved Exclusion Limits from the EDELWEISS WIMP Search
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chabert, L.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Riccio, C.;
Sanglard, V.;
Stern, M.;
Vagneron, L.
Submitted: 2002-06-17
The EDELWEISS experiment has improved its sensitivity for the direct search
for WIMP dark matter. In the recoil energy range relevant for WIMP masses below
10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a
heat-and-ionization cryogenic Ge detector operated in the low-background
environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel,
during an effective exposure of 7.4 kg.days. This result is combined with the
previous EDELWEISS data to derive a limit on the cross-section for
spin-independent interaction of WIMPs and nucleons as a function of WIMP mass,
using standard nuclear physics and astrophysical assumptions. This limit
excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a
cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first
sample of supersymmetric models are also excluded at 90%CL.
[6]
oai:arXiv.org:astro-ph/0106094 [pdf] - 173739
First Results of the EDELWEISS WIMP Search using a 320 g
Heat-and-Ionization Ge Detector
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Mosca, L.;
Miramonti, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Stern, M.;
Vagneron, L.
Submitted: 2001-06-06
The EDELWEISS collaboration has performed a direct search for WIMP dark
matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a
low-background environment in the Laboratoire Souterrain de Modane. No nuclear
recoils are observed in the fiducial volume in the 30-200 keV energy range
during an effective exposure of 4.53 kg.days. Limits for the cross-section for
the spin-independent interaction of WIMPs and nucleons are set in the framework
of the Minimal Supersymmetric Standard Model (MSSM). The central value of the
signal reported by the experiment DAMA is excluded at 90% CL.
[7]
oai:arXiv.org:astro-ph/0104192 [pdf] - 1943551
Dark Matter Search in the EDELWEISS experiment
Juillard, A.;
Benoit, A.;
Berge, L.;
Bonnevaux, A.;
Bouvier, R.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Cluzel, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
De Lesquen, A.;
Loidl, M.;
Loiseau, D.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X-F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.
Submitted: 2001-04-11
The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat
and ionisation read-out to identify nuclear recoils induced by elastic
collisions with WIMPs from the galactic halo. Preliminary results obtained with
320g bolometers are described. After a few weeks of data taking, data
accumulated with one of these detectors already allow to reach the upper part
of the DAMA region. Prospects for the present run and the second stage of the
experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data
taking with 100 detectors, are briefly described.
[8]
oai:arXiv.org:astro-ph/0101204 [pdf] - 1507854
Dark Matter Search in the Edelweiss Experiment
Chapellier, M.;
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.
Submitted: 2001-01-12, last modified: 2001-02-23
Preliminary results obtained with 320g bolometers with simultaneous
ionization and heat measurements are described. After a few weeks of data
taking, data accumulated with one of these detectors are beginning to exclude
the upper part of the DAMA region. Prospects for the present run and the second
stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat
allowing data taking with 100 detectors, are briefly described.
[9]
oai:arXiv.org:astro-ph/0101454 [pdf] - 40592
The EDELWEISS Experiment : Status and Outlook
Gascon, J.;
Benoit, A.;
Bonnevaux, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Cluzel, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Herve, J. P. Hadjout S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.;
Gascon, Jules
Submitted: 2001-01-25, last modified: 2001-02-06
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat
and ionisation read- out to identify nuclear recoils induced by elastic
collisions with WIMPs from the galactic halo. Results from the operation of 70
g and 320 g Ge detectors in the low-background environment of the Modane
Underground Laboratory (LSM) are presented.
[10]
oai:arXiv.org:astro-ph/0004308 [pdf] - 35667
Background discrimination capabilities of a heat and ionization
germanium cryogenic detector
Di Stefano, P.;
Berge, L.;
Chambon, B.;
Chapellier, M.;
Chaumont, J.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Drain, D.;
Dumoulin, L.;
Forget, P.;
Garoche, P.;
Gascon, J.;
Goldbach, C.;
L'Hote, D.;
Mallet, J.;
Mangin, J.;
Marnieros, S.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pecourt, S.;
Simon, E.;
Stab, L.;
Torre, J. -P.;
Tourbot, R.;
Yvon, D.
Submitted: 2000-04-21
The discrimination capabilities of a 70 g heat and ionization Ge bolometer
are studied. This first prototype has been used by the EDELWEISS Dark Matter
experiment, installed in the Laboratoire Souterrain de Modane, for direct
detection of WIMPs. Gamma and neutron calibrations demonstrate that this type
of detector is able to reject more than 99.6% of the background while retaining
95% of the signal, provided that the background events distribution is not
biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data
taken in a relatively important radioactive environment show an extra
population slightly overlapping the signal. This background is likely due to
interactions of low energy photons or electrons near the surface of the
crystal, and is somewhat reduced by applying a higher charge-collecting inverse
bias voltage (-6 V instead of -2 V) to the Ge diode. Despite this
contamination, more than 98% of the background can be rejected while retaining
50% of the signal. This yields a conservative upper limit of 0.7
event.day^{-1}.kg^{-1}.keV^{-1}_{recoil} at 90% confidence level in the 15-45
keV recoil energy interval; the present sensitivity appears to be limited by
the fast ambient neutrons. Upgrades in progress on the installation are
summarized.
[11]
oai:arXiv.org:astro-ph/0002462 [pdf] - 34805
Event categories in the EDELWEISS WIMP search experiment
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Garoche, P.;
Gascon, J.;
Goldbach, C.;
Gros, M.;
Juillard, A.;
de Lesquen, A.;
L'Hote, D.;
Mallet, L.;
Mangin, J.;
Marnieros, S.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X-F.;
Nollez, G.;
Pari, P.;
Pecourt, S.;
Simon, E.;
Stern, M.;
Torre, J-P.
Submitted: 2000-02-24
Four categories of events have been identified in the EDELWEISS-I dark matter
experiment using germanium cryogenic detectors measuring simultaneously charge
and heat signals. These categories of events are interpreted as electron and
nuclear interactions occurring in the volume of the detector, and electron and
nuclear interactions occurring close to the surface of the detectors(10-20 mu-m
of the surface). We discuss the hypothesis that low energy surface nuclear
recoils,which seem to have been unnoticed by previous WIMP searches, may
provide an interpretation of the anomalous events recorded by the UKDMC and
Saclay NaI experiments. The present analysis points to the necessity of taking
into account surface nuclear and electron recoil interactions for a reliable
estimate of background rejection factors.
[12]
oai:arXiv.org:astro-ph/9801199 [pdf] - 100048
Status of the EDELWEISS Experiment
Berge, L.;
Berkes, I.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Goldbach, C.;
Juillard, A.;
L'Hote, D.;
Marnieros, S.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Pecourt, S.;
Tourbot, R.;
Yvon, D.
Submitted: 1998-01-21
The status of the EDELWEISS experiment (underground dark matter search with
heat-ionisation bolometers) is reviewed. Auspicious results achieved with a
prototype 70 g Ge heat-ionisation detector under a 2 V reverse bias tension are
discussed. Based on gamma and neutron calibrations, a best-case rejection
factor, over the 15-45 keV range, of 99.7 % for gammas, with an acceptance of
94 % for neutrons, is presented first. Some operational results of physical
interest obtained under poor low radioactivity conditions follow. They include
a raw event rate of around 30 events/day/kg/keV over the same energy range,
and, after rejection of part of the background, lead to a conservative upper
limit on the signal of approximately 1.6 events/day/kg/keV at a 90 % confidence
level. Performance degrading surface effects of the detector are speculated
upon; and planned upgrades are summarized.