Normalized to: Douet, R.
[1]
oai:arXiv.org:0901.2429 [pdf] - 20405
Apodized Lyot Coronagraph for VLT-SPHERE: Laboratory tests and
performances of a first prototype in the visible
Guerri, Géraldine;
Robbe-Dubois, Sylvie;
Daban, Jean-Baptiste;
Abe, Lyu;
Douet, Richard;
Bendjoya, Philippe;
Vakili, Farrokh;
Carbillet, Marcel;
Beuzit, Jean-Luc;
Puget, Pascal;
Dohlen, Kjetil;
Mouillet, David
Submitted: 2009-01-16
We present some of the High Dynamic Range Imaging activities developed around
the coronagraphic test-bench of the Laboratoire A. H. Fizeau (Nice). They
concern research and development of an Apodized Lyot Coronagraph (ALC) for the
VLT-SPHERE instrument and experimental results from our testbed working in the
visible domain. We determined by numerical simulations the specifications of
the apodizing filter and searched the best technological process to manufacture
it. We present the results of the experimental tests on the first apodizer
prototype in the visible and the resulting ALC nulling performances. The tests
concern particularly the apodizer characterization (average transmission radial
profile, global reflectivity and transmittivity in the visible), ALC nulling
performances compared with expectations, sensitivity of the ALC performances to
misalignments of its components.
[2]
oai:arXiv.org:0807.0694 [pdf] - 14204
Prototyping coronagraphs for exoplanet characterization with SPHERE
Boccaletti, Anthony;
Abe, Lyu;
Baudrand, Jacques;
Daban, Jean-Baptiste;
Douet, Richard;
Guerri, Geraldine;
Robbe-Dubois, Sylvie;
Bendjoya, Philippe;
Dohlen, Kjetil;
Mawet, Dimitri
Submitted: 2008-07-04
The detection and characterization of extrasolar planets with SPHERE (Spectro
Polarimetric High contrast Exoplanet REsearch) is challenging and in particular
relies on the ability of a coronagraph to attenuate the diffracted starlight.
SPHERE includes 3 instruments, 2 of which can be operated simultaneously in the
near IR from 0.95 to 1.8 microns. This requirements is extremely critical for
coronagraphy. This paper briefly introduces the concepts of 2 coronagraphs, the
Half-Wave Plate Four Quadrant Phase Masks and the Apodized Pupil Lyot
Coronagraph, prototyped within the SPHERE consortium by LESIA (Observatory of
Paris) and FIZEAU (University of Nice) respectively. Then, we present the
measurements of contrast and sensitivity analysis. The comparison with
technical specifications allows to validate the technology for manufacturing
these coronagraphs.