Normalized to: Dorrer, C.
[1]
oai:arXiv.org:1111.6956 [pdf] - 1092005
Band-Limited Coronagraphs using a halftone-dot process: II. Advances and
laboratory results for arbitrary telescope apertures
Submitted: 2011-11-29
The band-limited coronagraph is a nearly ideal concept that theoretically
enables perfect cancellation of all the light of an on-axis source. Over the
past years, several prototypes have been developed and tested in the
laboratory, and more emphasis is now on developing optimal technologies that
can efficiently deliver the expected high-contrast levels of such a concept.
Following the development of an early near-IR demonstrator, we present and
discuss the results of a second-generation prototype using halftone-dot
technology. We report improvement in the accuracy of the control of the local
transmission of the manufactured prototype, which was measured to be less than
1%.
This advanced H-band band-limited device demonstrated excellent contrast
levels in the laboratory, down to 10-6 at farther angular separations than 3
lambda/D over 24% spectral bandwidth. These performances outperform the ones of
our former prototype by more than an order of magnitude and confirm the
maturity of the manufacturing process.
Current and next generation high-contrast instruments can directly benefit
from such capabilities. In this context, we experimentally examine the ability
of the band-limited coronagraph to withstand various complex telescope
apertures.
[2]
oai:arXiv.org:1102.3197 [pdf] - 1052130
Laboratory comparison of coronagraphic concepts under dynamical seeing
and high-order adaptive optics correction
Submitted: 2011-02-15
The exoplanetary science through direct imaging and spectroscopy will largely
expand with the forthcoming development of new instruments at the VLT (SPHERE),
Gemini (GPI), Subaru (HiCIAO), and Palomar (Project 1640) observatories. All
these ground-based adaptive optics instruments combine extremely high
performance adaptive optics (XAO) systems correcting for the atmospheric
turbulence with advanced starlight-cancellation techniques such as coronagraphy
to deliver contrast ratios of about 10-6 to 10-7. While the past fifteen years
have seen intensive research and the development of high-contrast coronagraph
concepts, very few concepts have been tested under dynamical seeing conditions
(either during sky observation or in a realistic laboratory environment). In
this paper, we discuss the results obtained with four different coronagraphs --
phase and amplitude types -- on the High-Order Testbench (HOT), the adaptive
optics facility developed at ESO. This facility emphasizes realistic conditions
encountered at a telescope (e.g., VLT), including a turbulence generator and a
high-order adaptive optics system. It enables to evaluate the performance of
high-contrast coronagraphs in the near-IR operating with an AO-corrected PSF of
90% Strehl ratio under 0.5 arcsec dynamical seeing.
[3]
oai:arXiv.org:0910.1183 [pdf] - 901969
Band-Limited Coronagraphs using a Halftone-dot process: design
guidelines, manufacturing, and laboratory results
Submitted: 2009-10-07
The Exo-Planet Imaging Camera and Spectrograph (EPICS) for the future
42-meter European-Extremely Large Telescope, will enable direct images, and
spectra for both young and old Jupiter-mass planets in the infrared. To achieve
the required contrast, several coronagraphic concepts -- to remove starlight --
are under investigation: conventional pupil apodization (CPA), apodized-pupil
Lyot coronagraph (APLC), dual-zone coronagraph (DZC), four-quadrants phase mask
(FQPM), multi-stages FQPM, annular groove phase mask (AGPM), high order optical
vortex (OVC), and band-limited coronagraph (BLC). Recent experiment
demonstrated the interest of an halftone-dot process -- namely microdots
technique -- to generate the adequate transmission profile of pupil apodizers
for CPA, APLC, and DZC concepts. Here, we examine the use of this technique to
produce band-limited focal plane masks, and present guidelines for the design.
Additionally, we present the first near-IR laboratory results with BLCs that
confirm the microdots approach as a suitable technique for ground-based
observations.
[4]
oai:arXiv.org:0904.2481 [pdf] - 1001937
Design, analysis, and testing of a microdot apodizer for the Apodized
Pupil Lyot Coronagraph. II. The dot size impact. (Research Note)
Submitted: 2009-04-16
The Apodized Pupil Lyot Coronagraph (APLC) is a promising coronagraphic
device for direct exoplanets detection on the European-Extremely Large
Telescope. We present new near-IR laboratory results using binary apodizers --
the so-called microdots apodizer -- which represent a very attractive and
advantageous solution for the APLC.
Microdots apodizers introduce high-frequency noise whose characteristics
depend on the pixel size. The aim of this work is to characterize the impact of
the pixel size on the coronagraphic image. Estimation of both the noise
intensity and its localization in the field of view is the objective of this
study.
Stray-light diffraction introduced by the finite pixel size was measured
during experiment. Intensity decreases, and radial distance increases, when the
pixel size gets smaller.
The physical properties of these microdots apodizers have been demonstrated
in laboratory. The microdots apodizer is a suitable solution for any
coronagraph using pupil amplitude apodization if properly designed.
[5]
oai:arXiv.org:0810.5678 [pdf] - 18059
Design, analysis and test of a microdots apodizer for the Apodized Pupil
Lyot Coronagraph
Submitted: 2008-10-31
Coronagraphic techniques are required to detect exoplanets with future
Extremely Large Telescopes. One concept, the Apodized Pupil Lyot Coronagraph
(APLC), is combining an apodizer in the entrance aperture and a Lyot opaque
mask in the focal plane. This paper presents the manufacturing and tests of a
microdots apodizer optimized for the near IR.
The intent of this work is to demonstrate the feasibility and performance of
binary apodizers for the APLC. This study is also relevant for any coronagraph
using amplitude pupil apodization.
A binary apodizer has been designed using a halftone dot process, where the
binary array of pixels with either 0% or 100% transmission is calculated to fit
the required continuous transmission, i.e. local transmission control is
obtained by varying the relative density of the opaque and transparent pixels.
An error diffusion algorithm was used to optimize the distribution of pixels
that best approximates the required field transmission. The prototype was
tested with a coronagraphic setup in the near IR.
The transmission profile of the prototype agrees with the theoretical shape
within 3% and is achromatic. The observed apodized and coronagraphic images are
consistent with theory. However, binary apodizers introduce high frequency
noise that is a function of the pixel size. Numerical simulations were used to
specify pixel size in order to minimize this effect, and validated by
experiment.
This paper demonstrates that binary apodizers are well suited for being used
in high contrast imaging coronagraphs. The correct choice of pixel size is
important and must be adressed considering the scientific field of view.