oai:arXiv.org:1911.08057 [pdf] - 2000344
Characterization of a 15 $\mu m$ Cutoff HgCdTe Detector Array for
Astronomy
Submitted: 2019-11-18
The University of Rochester infrared detector group is working together with
Teledyne Imaging Sensors to develop HgCdTe 15 $\mu m$ cutoff wavelength
detector arrays for future space missions. To reach the 15 $\mu m$ cutoff goal,
we took an intermediate step by developing four $\sim$13 $\mu m$ cutoff
wavelength arrays to identify any unforeseen effects related to increasing the
cutoff wavelength from the extensively characterized 10 $\mu m$ cutoff
wavelength detector arrays developed for the NEOCam mission. The
characterization of the $\sim$13 $\mu m$ cutoff wavelength HgCdTe arrays at the
University of Rochester allowed us to determine the key dark current mechanisms
that limit the performance of these HgCdTe detector arrays at different
temperatures and bias when the cutoff wavelength is increased. We present
initial dark current and well depth measurements of a 15 $\mu m$ cutoff array
which shows dark current values two orders of magnitude smaller at large
reverse bias than would be expected from our previous best structures.
[2]
oai:arXiv.org:1909.00947 [pdf] - 1963724
Development of 13 $\mu m$ Cutoff HgCdTe Detector Arrays for Astronomy
Submitted: 2019-09-03
Building on the successful development of the 10 $\mu m$ HgCdTe detector
arrays for the proposed NEOCam mission, the University of Rochester Infrared
Detector team and Teledyne Imaging Systems are working together to extend the
cutoff wavelength of HgCdTe detector arrays initially to 13 $\mu m$, with the
ultimate goal of developing 15 $\mu m$ HgCdTe detector arrays for space and
ground-based astronomy. The advantage of HgCdTe detector arrays is that they
can operate at higher temperatures than the currently used arsenic doped
silicon detector arrays at the longer wavelengths. Our infrared detector team
at the University of Rochester has received and tested four 13 $\mu m$ detector
arrays from Teledyne Imaging Systems with three different pixel designs, two of
which are meant to reduce quantum tunneling dark current. The pixel design of
one of these arrays has mitigated the effects of quantum tunneling dark
currents for which we have been able to achieve, at a temperature of 28 K and
applied bias of 350 mV, a well depth of at least 75 $ke^-$ for 90% of the
pixels with a median dark current of 1.8 $e^-/sec$. These arrays have
demonstrated encouraging results as we move forward to extending the cutoff
wavelength to 15 $\mu m$.
[3]
oai:arXiv.org:1608.04323 [pdf] - 1456182
Proton irradiation results for long-wave HgCdTe infrared detector arrays
for NEOCam
Submitted: 2016-08-15
HgCdTe detector arrays with a cutoff wavelength of ~10 ${\mu}$m intended for
the NEOCam space mission were subjected to proton beam irradiation at the
University of California Davis Crocker Nuclear Laboratory. Three arrays were
tested - one with 800 $\mu$m substrate intact, one with 30 $\mu$m substrate,
and one completely substrate-removed. The CdZnTe substrate, on which the HgCdTe
detector is grown, has been shown to produce luminescence in shorter wave
HgCdTe arrays that causes elevated signal in non-hit pixels when subjected to
proton irradiation. This testing was conducted to ascertain whether or not full
substrate removal is necessary. At the dark level of the dewar, we detect no
luminescence in non-hit pixels during proton testing for both the
substrate-removed detector array and the array with 30 ${\mu}$m substrate. The
detector array with full 800 ${\mu}$m substrate exhibited substantial
photocurrent for a flux of 103 protons/cm$^2$-s at a beam energy of 18.1 MeV (~
750 e$^-$/s) and 34.4 MeV ($\sim$ 65 e$^-$/s). For the integrated space-like
ambient proton flux level measured by the Spitzer Space Telescope, the
luminescence would be well below the NEOCam dark current requirement of <200
e$^-$/s, but the pattern of luminescence could be problematic, possibly
complicating calibration.
[4]
oai:arXiv.org:1306.6897 [pdf] - 686837
Development of sensitive long-wave infrared detector arrays for
passively cooled space missions
McMurtry, Craig;
Lee, Donald;
Beletic, James;
Chen, Chi-Yi A.;
Demers, Richard T.;
Dorn, Meghan;
Edwall, Dennis;
Fazar, Candice Bacon;
Forrest, William J.;
Liu, Fengchuan;
Mainzer, Amanda K.;
Pipher, Judith L.;
Yulius, Aristo
Submitted: 2013-06-28
The near-earth object camera (NEOCam) is a proposed infrared space mission
designed to discover and characterize most of the potentially hazardous
asteroids larger than 140 m in diameter that orbit near the Earth. NASA has
funded technology development for NEOCam, including the development of long
wavelength infrared detector arrays that will have excellent zodiacal
background emission-limited performance at passively cooled focal plane
temperatures. Teledyne Imaging Sensors has developed and delivered for test at
the University of Rochester the first set of approximately 10 micron cutoff,
1024 x 1024 pixel HgCdTe detector arrays. Measurements of these arrays show the
development to be extremely promising: noise, dark current, quantum efficiency,
and well depth goals have been met by this technology at focal plane
temperatures of 35 to 40 K, readily attainable with passive cooling. The next
set of arrays to be developed will address changes suggested by the first set
of deliverables.
[5]
oai:arXiv.org:0912.3545 [pdf] - 902792
Infrared Diagnostics for the Extended 12 micron Sample of Seyferts
Baum, Stefi A.;
Gallimore, Jack F.;
O'Dea, Christopher P.;
Buchanan, Catherine L.;
Noel-Storr, Jacob;
Axon, David J.;
Robinson, Andy;
Elitzur, Moshe;
Dorn, Meghan;
Staudaher, Shawn;
Elvis, Martin
Submitted: 2009-12-17
We present an analysis of Spitzer IRS spectroscopy of 83 active galaxies from
the extended 12 micron sample. We find rank correlations between several
tracers of star formation which suggest that (1) the PAH feature is a reliable
tracer of star formation, (2) there is a significant contribution to the
heating of the cool dust by stars, (3) the H$_2$ emission is also primarily
excited by star formation. The 55-90 vs. 20-30 spectral index plot is also a
diagnostic of the relative contribution of Starburst to AGN. We see there is a
large change in spectral index across the sample. Thus, the contribution to the
IR spectrum from the AGN and starburst components can be comparable in
magnitude but the relative contribution also varies widely across the sample.
We find rank correlations between several AGN tracers. We search for
correlations between AGN and Starburst tracers and we conclude that the AGN and
Starburst tracers are not correlated. This is consistent with our conclusion
that the relative strength of the AGN and Starburst components varies widely
across the sample. Thus, there is no simple link between AGN fueling and Black
Hole Growth and star formation in these galaxies. The distribution of Sil 10
micron and 18 micron strengths is consistent with the clumpy torus models of
Sirocky et al. We find a rank correlation between the [NeV] 14 micron line and
the 6.7 micron continuum which may be due to an extended component of hot dust.
The Sy 2s with a Hidden Broad Line Region (HBLR) have a higher ratio of AGN to
Starburst contribution to the SED than Sy 2s without an HBLR. This may
contribute to the detection of the HBLR in polarized light. The Sy 2s with an