Normalized to: Dolbeau, J.
[1]
oai:arXiv.org:0704.1532 [pdf] - 340
Absolute measurement of the nitrogen fluorescence yield in air between
300 and 430 nm
Submitted: 2007-04-12
The nitrogen fluorescence induced in air is used to detect ultra-high energy
cosmic rays and to measure their energy. The precise knowledge of the absolute
fluorescence yield is the key quantity to improve the accuracy on the cosmic
ray energy. The total yield has been measured in dry air using a 90Sr source
and a [300-430 nm] filter. The fluorescence yield in air is 4.23 $\pm$ 0.20
photons per meter when normalized to 760 mmHg, 15 degrees C and with an
electron energy of 0.85 MeV. This result is consistent with previous
experiments made at various energies, but with an accuracy improved by a factor
of about 3. For the first time, the absolute continuous spectrum of nitrogen
excited by 90Sr electrons has also been measured with a spectrometer. Details
of this experiment are given in one of the author's PhD thesis [32].
[2]
oai:arXiv.org:physics/0507138 [pdf] - 119101
UV Light Shower Simulator for Fluorescence and Cerenkov Radiation
Studies
Submitted: 2005-07-18
All experiments observing showers light use telescopes equipped with
pixellised photodetectors. Monte-Carlo (MC) simulations of the apparatus
operation in various situations (background light, shower energy, proximity of
tracks...) are mandatory, but never enter into detector details like pulse
shape, dead-time, or charge space effects which are finally responsible for the
data quality. An apparatus where each pixel receives light from individual 370
nm UV LEDs through silica fibers is being built. The LEDs receive voltage
through DACs, which get their input (which pixel, at what time, which
amplitude) from a shower plus noise generator code. The typical time constant
of a shower being one $/mu$s (300 m for light), the pulses are one $/mu$s wide.
This is rather long compared to the intrinsic time constant (around 10 ns) of
the light detectors, hence, these see "constant light" changing every $/mu$s.
This is where important loading effects which are not included in MC code can
be observed. The fibers illuminate the pixels through a diffuser, and each
fiber illuminates only one pixel. The number of equipped pixels is such that it
englobes a full shower (much less than the full focal surface). Finally, this
equipment can be used also to calibrate the pixels.