Normalized to: Doke, T.
[1]
oai:arXiv.org:physics/0702078 [pdf] - 119207
A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during
the 2000 Balloon Flight Campaign
Submitted: 2007-02-09
LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype
of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time
projection chamber. One of the most relevant figures of merit for a Compton
telescope is the detection efficiency for \g-rays, which depends on diverse
contributions such as detector geometry and passive materials, trigger
efficiency, dead time, etc. A detailed study of the efficiency of the LXeGRIT
instrument, based both on laboratory measurements and Monte Carlo simulations,
is presented in this paper.
[2]
oai:arXiv.org:astro-ph/0211584 [pdf] - 53319
On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon
Flight
Curioni, A.;
Aprile, E.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-26, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray
astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC),
sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position
sensitive detector, gamma rays with at least two interactions in the sensitive
volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope.
Gamma-rays with a single interaction cannot be imaged and constitute a
background which can be easily identified and rejected. Charged particles and
localized beta-particles background is also easily suppressed based on the TPC
localization capability with millimeter resolution. A measurement of the total
gamma-ray background rate in near space conditions and the background rejection
power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program.
We present here a preliminary analysis addressing this question, based on
balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight
from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the
LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield.
Single site events and charged particles were mostly rejected on-line at the
first and second trigger level. The remaining count rate of single-site \g-ray
events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with
that expected from atmospheric and diffuse gamma-ray background, taking into
account the instrument mass model and response.
[3]
oai:arXiv.org:astro-ph/0212005 [pdf] - 53395
The LXeGRIT Compton Telescope Prototype: Current Status and Future
Prospects
Aprile, E.;
Curioni, A.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-30, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel concept of Compton telescope, based
on the complete 3-dimensional reconstruction of the sequence of interactions of
individual gamma rays in one position sensitive detector. This balloon-borne
telescope consists of an unshielded time projection chamber with an active
volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV
PMTs detect the fast xenon scintillation light signal, providing the event
trigger. 124 wires and 4 anodes detect the ionization signals, providing the
event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT
has been extensively tested both in the laboratory and at balloon altitude, and
its response in the MeV region has been thoroughly characterized. Here we
summarize some of the results on pre-flight calibration, event reconstruction
techniques, and performance during a 27 hour balloon flight on October 4 -- 5.
We further present briefly the on-going efforts directed to improve the
performance of this prototype towards the requirements for a base module of a
next-generation Compton telescope.