Normalized to: Dohlen, K.
[1]
oai:arXiv.org:2004.12878 [pdf] - 2084385
K-Stacker, an algorithm to hack the orbital parameters of planets hidden
in high-contrast imaging. First applications to VLT SPHERE multi-epoch
observations
Coroller, H. Le;
Nowak, M.;
Delorme, P.;
Chauvin, G.;
Gratton, R.;
Devinat, M.;
Bec-Canet, J.;
Schneeberger, A.;
Estevez, D.;
Arnold, L.;
Beust, H.;
Bonnefoy, M.;
Boccaletti, A.;
Desgrange, C.;
Desidera, S.;
Galicher, R.;
Lagrange, A. M.;
Langlois, M.;
Maire, A. L.;
Menard, F.;
Vernazza, P.;
Vigan, A.;
Zurlo, A.;
Fenouillet, T.;
Lambert, J. C.;
Bonavita, M.;
Cheetham, A.;
Dorazi, V.;
Feldt, M.;
Janson, M.;
Ligi, R.;
Mesa, D.;
Meyer, M.;
Samland, M.;
Sissa, E.;
Beuzit, J. L.;
Dohlen, K.;
Fusco, T.;
Mignant, D. Le;
Mouillet, D.;
Ramos, J.;
Rochat, S.;
Sauvage, J. F.
Submitted: 2020-04-27
Recent high-contrast imaging surveys, looking for planets in young, nearby
systems showed evidence of a small number of giant planets at relatively large
separation beyond typically 20 au where those surveys are the most sensitive.
Access to smaller physical separations between 5 and 20 au is the next step for
future planet imagers on 10 m telescopes and ELTs in order to bridge the gap
with indirect techniques (radial velocity, transit, astrometry with Gaia). In
that context, we recently proposed a new algorithm, Keplerian-Stacker,
combining multiple observations acquired at different epochs and taking into
account the orbital motion of a potential planet present in the images to boost
the ultimate detection limit. We showed that this algorithm is able to find
planets in time series of simulated images of SPHERE even when a planet remains
undetected at one epoch. Here, we validate the K-Stacker algorithm performances
on real SPHERE datasets, to demonstrate its resilience to instrumental speckles
and the gain offered in terms of true detection. This will motivate future
dedicated multi-epoch observation campaigns in high-contrast imaging to search
for planets in emitted and reflected light. Results. We show that K-Stacker
achieves high success rate when the SNR of the planet in the stacked image
reaches 7. The improvement of the SNR ratio goes as the square root of the
total exposure time. During the blind test and the redetection of HD 95086 b,
and betaPic b, we highlight the ability of K-Stacker to find orbital solutions
consistent with the ones derived by the state of the art MCMC orbital fitting
techniques, confirming that in addition to the detection gain, K-Stacker offers
the opportunity to characterize the most probable orbital solutions of the
exoplanets recovered at low signal to noise.
[2]
oai:arXiv.org:2003.07228 [pdf] - 2064627
Design of the HARMONI Pyramid WFS module
Schwartz, Noah;
Sauvage, Jean-François;
Renault, Edgard;
Correia, Carlos;
Neichel, Benoit;
Fusco, Thierry;
Dohlen, Kjetil;
Hadi, Kacem El;
Petit, Cyril;
Choquet, Elodie;
Chambouleyron, Vincent;
Paufique, Jerome;
Clarke, Fraser;
Thatte, Niranjan;
Bryson, Ian
Submitted: 2020-03-13
Current designs for all three extremely large telescopes show the
overwhelming adoption of the pyramid wavefront sensor (P-WFS) as the WFS of
choice for adaptive optics (AO) systems sensing on natural guide stars (NGS) or
extended objects. The key advantages of the P-WFS over the Shack-Hartmann are
known and are mainly provided by the improved sensitivity (fainter NGS) and
reduced sensitivity to spatial aliasing. However, robustness and tolerances of
the P-WFS for the ELTs are not currently well understood. In this paper, we
present simulation results for the single-conjugate AO mode of HARMONI, a
visible and near-infrared integral field spectrograph for the European
Extremely Large Telescope. We first explore the wavefront sensing issues
related to the telescope itself; namely the island effect (i.e. differential
piston) and M1 segments phasing errors. We present mitigation strategies to the
island effect and their performance. We then focus on some performance
optimisation aspects of the AO design to explore the impact of the RTC latency
and the optical gain issues, which will in particular affect the high-contrast
mode of HARMONI. Finally, we investigate the influence of the quality of glass
pyramid prism itself, and of optical aberrations on the final AO performance.
By relaxing the tolerances on the fabrication of the prism, we are able to
reduce hardware costs and simplify integration. We show the importance of
calibration (i.e. updating the control matrix) to capture any displacement of
the telescope pupil and rotation of the support structure for M4. We also show
the importance of the number of pixels used for wavefront sensing to relax
tolerances of the pyramid prism. Finally, we present a detailed optical design
of the pyramid prism, central element of the P-WFS.
[3]
oai:arXiv.org:2003.05714 [pdf] - 2063822
SPHERE+: Imaging young Jupiters down to the snowline
Boccaletti, A.;
Chauvin, G.;
Mouillet, D.;
Absil, O.;
Allard, F.;
Antoniucci, S.;
Augereau, J. -C.;
Barge, P.;
Baruffolo, A.;
Baudino, J. -L.;
Baudoz, P.;
Beaulieu, M.;
Benisty, M.;
Beuzit, J. -L.;
Bianco, A.;
Biller, B.;
Bonavita, B.;
Bonnefoy, M.;
Bos, S.;
Bouret, J. -C.;
Brandner, W.;
Buchschache, N.;
Carry, B.;
Cantalloube, F.;
Cascone, E.;
Carlotti, A.;
Charnay, B.;
Chiavassa, A.;
Choquet, E.;
Clenet, Y.;
Crida, A.;
De Boer, J.;
De Caprio, V.;
Desidera, S.;
Desert, J. -M.;
Delisle, J. -B.;
Delorme, P.;
Dohlen, K.;
Doelman, D.;
Dominik, C.;
Orazi, V. D;
Dougados, C.;
Doute, S.;
Fedele, D.;
Feldt, M.;
Ferreira, F.;
Fontanive, C.;
Fusco, T.;
Galicher, R.;
Garufi, A.;
Gendron, E.;
Ghedina, A.;
Ginski, C.;
Gonzalez, J. -F.;
Gratadour, D.;
Gratton, R.;
Guillot, T.;
Haffert, S.;
Hagelberg, J.;
Henning, T.;
Huby, E.;
Janson, M.;
Kamp, I.;
Keller, C.;
Kenworthy, M.;
Kervella, P.;
Kral, Q.;
Kuhn, J.;
Lagadec, E.;
Laibe, G.;
Langlois, M.;
Lagrange, A. -M.;
Launhardt, R.;
Leboulleux, L.;
Coroller, H. Le;
Causi, G. Li;
Loupias, M.;
Maire, A. L.;
Marleau, G.;
Martinache, F.;
Martinez, P.;
Mary, D.;
Mattioli, M.;
Mazoyer, J.;
Meheut, H.;
Menard, F.;
Mesa, D.;
Meunier, N.;
Miguel, Y.;
Milli, J.;
Min, M.;
Molliere, P.;
Mordasini, C.;
Moretto, G.;
Mugnier, L.;
Arena, G. Muro;
Nardetto, N.;
Diaye, M. N;
Nesvadba, N.;
Pedichini, F.;
Pinilla, P.;
Por, E.;
Potier, A.;
Quanz, S.;
Rameau, J.;
Roelfsema, R.;
Rouan, D.;
Rigliaco, E.;
Salasnich, B.;
Samland, M.;
Sauvage, J. -F.;
Schmid, H. -M.;
Segransan, D.;
Snellen, I.;
Snik, F.;
Soulez, F.;
Stadler, E.;
Stam, D.;
Tallon, M.;
Thebault, P.;
Thiebaut, E.;
Tschudi, C.;
Udry, S.;
van Holstein, R.;
Vernazza, P.;
Vidal, F.;
Vigan, A.;
Waters, R.;
Wildi, F.;
Willson, M.;
Zanutta, A.;
Zavagno, A.;
Zurlo, A.
Submitted: 2020-03-12, last modified: 2020-03-13
SPHERE (Beuzit et al,. 2019) has now been in operation at the VLT for more
than 5 years, demonstrating a high level of performance. SPHERE has produced
outstanding results using a variety of operating modes, primarily in the field
of direct imaging of exoplanetary systems, focusing on exoplanets as point
sources and circumstellar disks as extended objects. The achievements obtained
thus far with SPHERE (~200 refereed publications) in different areas
(exoplanets, disks, solar system, stellar physics...) have motivated a large
consortium to propose an even more ambitious set of science cases, and its
corresponding technical implementation in the form of an upgrade. The SPHERE+
project capitalizes on the expertise and lessons learned from SPHERE to push
high contrast imaging performance to its limits on the VLT 8m-telescope. The
scientific program of SPHERE+ described in this document will open a new and
compelling scientific window for the upcoming decade in strong synergy with
ground-based facilities (VLT/I, ELT, ALMA, and SKA) and space missions (Gaia,
JWST, PLATO and WFIRST). While SPHERE has sampled the outer parts of planetary
systems beyond a few tens of AU, SPHERE+ will dig into the inner regions around
stars to reveal and characterize by mean of spectroscopy the giant planet
population down to the snow line. Building on SPHERE's scientific heritage and
resounding success, SPHERE+ will be a dedicated survey instrument which will
strengthen the leadership of ESO and the European community in the very
competitive field of direct imaging of exoplanetary systems. With enhanced
capabilities, it will enable an even broader diversity of science cases
including the study of the solar system, the birth and death of stars and the
exploration of the inner regions of active galactic nuclei.
[4]
oai:arXiv.org:2003.05794 [pdf] - 2124664
The wind-driven halo in high-contrast images I: analysis from the focal
plane images of SPHERE
Cantalloube, Faustine;
Farley, Ollie;
Milli, Julien;
Bharmal, Nazim Ali;
Brandner, Wolfgang;
Correia, Carlos;
Dohlen, Kjetil;
Henning, Th;
Osborn, James;
Por, Emiel;
Valles, M Suárez;
Vigan, Arthur
Submitted: 2020-03-12
Context. The wind driven halo is a feature observed within the images
delivered by the latest generation of ground-based instruments equipped with an
extreme adaptive optics system and a coronagraphic device, such as SPHERE at
the VLT. This signature appears when the atmospheric turbulence conditions are
varying faster than the adaptive optics loop can correct. The wind driven halo
shows as a radial extension of the point spread function along a distinct
direction (sometimes referred to as the butterfly pattern). When present, it
significantly limits the contrast capabilities of the instrument and prevents
the extraction of signals at close separation or extended signals such as
circumstellar disks. This limitation is consequential because it contaminates
the data a substantial fraction of the time: about 30% of the data produced by
the VLT/SPHERE instrument are affected by the wind driven halo.Aims. This paper
reviews the causes of the wind driven halo and presents a method to analyze its
contribution directly from the scientific images. Its effect on the raw
contrast and on the final contrast after post-processing is
demonstrated.Methods. We used simulations and on-sky SPHERE data to verify that
the parameters extracted with our method are capable of describing the wind
driven halo present in the images. We studied the temporal, spatial and
spectral variation of these parameters to point out its deleterious effect on
the final contrast.Results. The data driven analysis we propose does provide
information to accurately describe the wind driven halo contribution in the
images. This analysis justifies why this is a fundamental limitation to the
final contrast performance reached.Conclusions. With the established procedure,
we will analyze a large sample of data delivered by SPHERE in order to propose,
in the future, post-processing techniques tailored to remove the wind driven
halo.
[5]
oai:arXiv.org:1911.12759 [pdf] - 2046349
RefPlanets: Search for reflected light from extra-solar planets with
SPHERE/ZIMPOL
Hunziker, S.;
Schmid, H. M.;
Mouillet, D.;
Milli, J.;
Zurlo, A.;
Delorme, P.;
Abe, L.;
Avenhaus, H.;
Baruffolo, A.;
Bazzon, A.;
Boccaletti, A.;
Baudoz, P.;
Beuzit, J. L.;
Carbillet, M.;
Chauvin, G.;
Claudi, R.;
Costille, A.;
Daban, J. B.;
Desidera, S.;
Dohlen, K.;
Dominik, C.;
Downing, M.;
Engler, N.;
Feldt, M.;
Fusco, T.;
Ginski, C.;
Gisler, D.;
Girard, J. H.;
Gratton, R.;
Henning, Th.;
Hubin, N.;
Kasper, M.;
Keller, C. U.;
Langlois, M.;
Lagadec, E.;
Martinez, P.;
Maire, A. L.;
Menard, F.;
Meyer, M. R.;
Pavlov, A.;
Pragt, J.;
Puget, P.;
Quanz, S. P.;
Rickman, E.;
Roelfsema, R.;
Salasnich, B.;
Sauvage, J. F.;
Siebenmorgen, R.;
Sissa, E.;
Snik, F.;
Suarez, M.;
Szulagyi, J.;
Thalmann, Ch.;
Turatto, M.;
Udry, S.;
van Holstein, R. G.;
Vigan, A.;
Wildi, F.
Submitted: 2019-11-28
RefPlanets is a guaranteed time observation (GTO) programme that uses the
Zurich IMaging POLarimeter (ZIMPOL) of SPHERE/VLT for a blind search for
exoplanets in wavelengths from 600-900 nm. The goals of this study are the
characterization of the unprecedented high polarimetic contrast and
polarimetric precision capabilities of ZIMPOL for bright targets, the search
for polarized reflected light around some of the closest bright stars to the
Sun and potentially the direct detection of an evolved cold exoplanet for the
first time. For our observations of Alpha Cen A and B, Sirius A, Altair, Eps
Eri and Tau Ceti we used the polarimetric differential imaging (PDI) mode of
ZIMPOL which removes the speckle noise down to the photon noise limit for
angular separations >0.6". We describe some of the instrumental effects that
dominate the noise for smaller separations and explain how to remove these
additional noise effects in post-processing. We then combine PDI with angular
differential imaging (ADI) as a final layer of post-processing to further
improve the contrast limits of our data at these separations. For good
observing conditions we achieve polarimetric contrast limits of 15.0-16.3 mag
at the effective inner working angle of about 0.13", 16.3-18.3 mag at 0.5" and
18.8-20.4 mag at 1.5". The contrast limits closer in (<0.6") depend
significantly on the observing conditions, while in the photon noise dominated
regime (>0.6"), the limits mainly depend on the brightness of the star and the
total integration time. We compare our results with contrast limits from other
surveys and review the exoplanet detection limits obtained with different
detection methods. For all our targets we achieve unprecedented contrast
limits. Despite the high polarimetric contrasts we are not able to find any
additional companions or extended polarized light sources in the data that has
been taken so far.
[6]
oai:arXiv.org:1902.04080 [pdf] - 1996682
SPHERE: the exoplanet imager for the Very Large Telescope
Beuzit, J. -L.;
Vigan, A.;
Mouillet, D.;
Dohlen, K.;
Gratton, R.;
Boccaletti, A.;
Sauvage, J. -F.;
Schmid, H. M.;
Langlois, M.;
Petit, C.;
Baruffolo, A.;
Feldt, M.;
Milli, J.;
Wahhaj, Z.;
Abe, L.;
Anselmi, U.;
Antichi, J.;
Barette, R.;
Baudrand, J.;
Baudoz, P.;
Bazzon, A.;
Bernardi, P.;
Blanchard, P.;
Brast, R.;
Bruno, P.;
Buey, T.;
Carbillet, M.;
Carle, M.;
Cascone, E.;
Chapron, F.;
Chauvin, G.;
Charton, J.;
Claudi, R.;
Costille, A.;
De Caprio, V.;
Delboulbé, A.;
Desidera, S.;
Dominik, C.;
Downing, M.;
Dupuis, O.;
Fabron, C.;
Fantinel, D.;
Farisato, G.;
Feautrier, P.;
Fedrigo, E.;
Fusco, T.;
Gigan, P.;
Ginski, C.;
Girard, J.;
Giro, E.;
Gisler, D.;
Gluck, L.;
Gry, C.;
Henning, T.;
Hubin, N.;
Hugot, E.;
Incorvaia, S.;
Jaquet, M.;
Kasper, M.;
Lagadec, E.;
Lagrange, A. -M.;
Coroller, H. Le;
Mignant, D. Le;
Ruyet, B. Le;
Lessio, G.;
Lizon, J. -L.;
Llored, M.;
Lundin, L.;
Madec, F.;
Magnard, Y.;
Marteaud, M.;
Martinez, P.;
Maurel, D.;
Ménard, F.;
Mesa, D.;
Möller-Nilsson, O.;
Moulin, T.;
Moutou, C.;
Origné, A.;
Parisot, J.;
Pavlov, A.;
Perret, D.;
Pragt, J.;
Puget, P.;
Rabou, P.;
Ramos, J.;
Reess, J. -M.;
Rigal, F.;
Rochat, S.;
Roelfsema, R.;
Rousset, G.;
Roux, A.;
Saisse, M.;
Salasnich, B.;
Santambrogio, E.;
Scuderi, S.;
Segransan, D.;
Sevin, A.;
Siebenmorgen, R.;
Soenke, C.;
Stadler, E.;
Suarez, M.;
Tiphène, D.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Waters, L. B. F. M.;
Weber, L.;
Wildi, F.;
Zins, G.;
Zurlo, A.
Submitted: 2019-02-11, last modified: 2019-10-03
Observations of circumstellar environments to look for the direct signal of
exoplanets and the scattered light from disks has significant instrumental
implications. In the past 15 years, major developments in adaptive optics,
coronagraphy, optical manufacturing, wavefront sensing and data processing,
together with a consistent global system analysis have enabled a new generation
of high-contrast imagers and spectrographs on large ground-based telescopes
with much better performance. One of the most productive is the
Spectro-Polarimetic High contrast imager for Exoplanets REsearch (SPHERE)
designed and built for the ESO Very Large Telescope (VLT) in Chile. SPHERE
includes an extreme adaptive optics system, a highly stable common path
interface, several types of coronagraphs and three science instruments. Two of
them, the Integral Field Spectrograph (IFS) and the Infra-Red Dual-band Imager
and Spectrograph (IRDIS), are designed to efficiently cover the near-infrared
(NIR) range in a single observation for efficient young planet search. The
third one, ZIMPOL, is designed for visible (VIR) polarimetric observation to
look for the reflected light of exoplanets and the light scattered by debris
disks. This suite of three science instruments enables to study circumstellar
environments at unprecedented angular resolution both in the visible and the
near-infrared. In this work, we present the complete instrument and its on-sky
performance after 4 years of operations at the VLT.
[7]
oai:arXiv.org:1909.13107 [pdf] - 2030544
The polarimetric imaging mode of VLT/SPHERE/IRDIS I: Description, data
reduction and observing strategy
de Boer, J.;
Langlois, M.;
van Holstein, R. G.;
Girard, J. H.;
Mouillet, D.;
Vigan, A.;
Dohlen, K.;
Snik, F.;
Keller, C. U.;
Ginski, C.;
Stam, D. M.;
Milli, J.;
Wahhaj, Z.;
Kasper, M.;
Schmid, H. M.;
Rabou, P.;
Gluck, L.;
Hugot, E.;
Perret, D.;
Martinez, P.;
Weber, L.;
Pragt, J.;
Sauvage, J. -F.;
Boccaletti, A.;
Coroller, H. Le;
Dominik, C.;
Henning, T.;
Lagadec, E.;
Ménard, F.;
Turatto, M.;
Udry, S.;
Chauvin, G.;
Feldt, M.;
Beuzit, J. -L.
Submitted: 2019-09-28
Context. Polarimetric imaging is one of the most effective techniques for
high-contrast imaging and characterization of protoplanetary disks, and has the
potential to be instrumental in characterizing exoplanets. VLT/SPHERE contains
the InfraRed Dual-band Imager and Spectrograph (IRDIS) with a dual-beam
polarimetric imaging (DPI) mode, which offers the capability to obtain linear
polarization images at high contrast and resolution. Aims. We aim to provide an
overview of IRDIS/DPI and study its optical design to improve observing
strategies and data reduction. Methods. For H-band observations of TW Hya, we
compare two data reduction methods that correct for instrumental polarization
effects in different ways: a minimization of the noise image, and a
polarimetric-model-based correction method that we present in Paper II of this
study. Results. We use observations of TW Hya to illustrate the data reduction.
In the images of the protoplanetary disk around this star we detect variability
in the polarized intensity and angle of linear polarization with
pointing-dependent instrument configuration. We explain these variations as
instrumental polarization effects and correct for these effects using our
model-based correction method. Conclusions. IRDIS/DPI has proven to be a very
successful and productive high-contrast polarimetric imaging system. However,
the instrument performance depends on the specific instrument configuration. We
suggest adjustments to future observing strategies to optimize polarimetric
efficiency in field tracking mode by avoiding unfavourable derotator angles. We
recommend reducing on-sky data with the pipeline called IRDAP that includes the
model-based correction method (described in Paper II) to optimally account for
the remaining telescope and instrumental polarization effects and to retrieve
the true polarization state of the incident light.
[8]
oai:arXiv.org:1909.13108 [pdf] - 2030545
The polarimetric imaging mode of VLT/SPHERE/IRDIS II: Characterization
and correction of instrumental polarization effects
van Holstein, R. G.;
Girard, J. H.;
de Boer, J.;
Snik, F.;
Milli, J.;
Stam, D. M.;
Ginski, C.;
Mouillet, D.;
Wahhaj, Z.;
Schmid, H. M.;
Keller, C. U.;
Langlois, M.;
Dohlen, K.;
Vigan, A.;
Pohl, A.;
Carbillet, M.;
Fantinel, D.;
Maurel, D.;
Origné, A.;
Petit, C.;
Ramos, J.;
Rigal, F.;
Sevin, A.;
Boccaletti, A.;
Coroller, H. Le;
Dominik, C.;
Henning, T.;
Lagadec, E.;
Ménard, F.;
Turatto, M.;
Udry, S.;
Chauvin, G.;
Feldt, M.;
Beuzit, J. -L.
Submitted: 2019-09-28
Context. Circumstellar disks and self-luminous giant exoplanets or companion
brown dwarfs can be characterized through direct-imaging polarimetry at
near-infrared wavelengths. SPHERE/IRDIS at the Very Large Telescope has the
capabilities to perform such measurements, but uncalibrated instrumental
polarization effects limit the attainable polarimetric accuracy. Aims. We aim
to characterize and correct the instrumental polarization effects of the
complete optical system, i.e. the telescope and SPHERE/IRDIS. Methods. We
create a detailed Mueller matrix model in the broadband filters Y-, J-, H- and
Ks, and calibrate it using measurements with SPHERE's internal light source and
observations of two unpolarized stars. We develop a data-reduction method that
uses the model to correct for the instrumental polarization effects, and apply
it to observations of the circumstellar disk of T Cha. Results. The
instrumental polarization is almost exclusively produced by the telescope and
SPHERE's first mirror and varies with telescope altitude angle. The crosstalk
primarily originates from the image derotator (K-mirror). At some orientations,
the derotator causes severe loss of signal (>90% loss in H- and Ks-band) and
strongly offsets the angle of linear polarization. With our correction method
we reach in all filters a total polarimetric accuracy of <0.1% in the degree of
linear polarization and an accuracy of a few degrees in angle of linear
polarization. Conclusions. The correction method enables us to accurately
measure the polarized intensity and angle of linear polarization of
circumstellar disks, and is a vital tool for detecting unresolved (inner) disks
and measuring the polarization of substellar companions. We have incorporated
the correction method in a highly-automatic end-to-end data-reduction pipeline
called IRDAP which is publicly available at https://irdap.readthedocs.io.
[9]
oai:arXiv.org:1907.11241 [pdf] - 1949408
Calibration of quasi-static aberrations in exoplanet direct-imaging
instruments with a Zernike phase-mask sensor. III. On-sky validation in
VLT/SPHERE
Vigan, A.;
N'Diaye, M.;
Dohlen, K.;
Sauvage, J. -F.;
Milli, J.;
Zins, G.;
Petit, C.;
Wahhaj, Z.;
Cantalloube, F.;
Caillat, A.;
Costille, A.;
Merrer, J. Le;
Carlotti, A.;
Beuzit, J. -L.;
Mouillet, D.
Submitted: 2019-07-25
Second-generation exoplanet imagers using extreme adaptive optics and
coronagraphy have demonstrated their great potential for studying close
circumstellar environments and for detecting new companions and helping to
understand their physical properties. However, at very small angular
separation, their performance in contrast is limited by several factors:
diffraction by the complex telescope pupil not perfectly canceled by the
coronagraph, residual dynamic wavefront errors, chromatic wavefront errors, and
wavefront errors resulting from noncommon path aberrations (NCPAs). In a
previous work, we demonstrated the use of a Zernike wavefront sensor called
ZELDA for sensing NCPAs in VLT/SPHERE and their compensation. In the present
work, we move to the next step with the on-sky validation of NCPA compensation
with ZELDA. We start by reproducing previous results on the internal source and
show that the amount of aberration integrated between 1 and 15 cycles/pupil is
decreased by a factor of five, which translates into a gain in raw contrast of
between 2 and 3 below 300 mas. On sky, we demonstrate that NCPA compensation
works in closed loop, leading to an attenuation of the amount of aberration by
a factor of approximately two. However, we identify a loss of sensitivity for
the sensor that is only partly explained by the difference in Strehl ratio
between the internal and on-sky measurements. Coronagraphic imaging on sky is
improved in raw contrast by a factor of 2.5 at most in the ExAO-corrected
region. We use coronagraphic image reconstruction based on a detailed model of
the instrument to demonstrate that both internal and on-sky raw contrasts can
be precisely explained, and we establish that the observed performance after
NCPA compensation is no longer limited by an improper compensation for
aberration but by the current apodized-pupil Lyot coronagraph design.
[abridged]
[10]
oai:arXiv.org:1907.07038 [pdf] - 1925148
Coronagraphic phase diversity through residual turbulence: performance
study and experimental validation
Submitted: 2019-07-16
Quasi-static aberrations in coronagraphic systems are the ultimate limitation
to the capabilities of exoplanet imagers both ground-based and space-based.
These aberrations - which can be due to various causes such as optics alignment
or moving optical parts during the observing sequence - create light residuals
called speckles in the focal plane that might be mistaken for a planets. For
ground-based instruments, the presence of residual turbulent wavefront errors
due to partial adaptive optics correction causes an additional difficulty to
the challenge of measuring aberrations in the presence of a coronagraph. In
this paper, we present an extension of COFFEE, the coronagraphic phase
diversity, to the estimation of quasi-static aberrations in the presence of
adaptive optics-corrected residual turbulence. We perform realistic numerical
simulations to assess the performance that can be expected on an instrument of
the current generation. We perform the first experimental validation in the
laboratory which demonstrates that quasistatic aberrations can be corrected
during the observations by means of coronagraphic phase diversity.
[11]
oai:arXiv.org:1907.03624 [pdf] - 1912094
Peering through SPHERE Images: A Glance at Contrast Limitations
Submitted: 2019-07-08
Various structures are visible within Spectro-Polarimetric High-contrast
Exoplanet REsearch instrument (SPHERE) images that are not always
straightforward to interpret. In this article we present a review of these
features and demonstrate their origin using simulations. We also identify which
expected or unexpected features are limiting the contrast reached by the
instrument and how they may be tackled. This vision paves the way to designing
a future upgrade of the SPHERE instrument and the next generation of
high-contrast instruments such as those planned for the Extremely Large
Telescope (ELT).
[12]
oai:arXiv.org:1903.07620 [pdf] - 1871543
Hint of curvature in the orbital motion of the exoplanet 51 Eridani b
using 3 years of VLT/SPHERE monitoring
Maire, A. -L.;
Rodet, L.;
Cantalloube, F.;
Galicher, R.;
Brandner, W.;
Messina, S.;
Lazzoni, C.;
Mesa, D.;
Melnick, D.;
Carson, J.;
Samland, M.;
Biller, B. A.;
Boccaletti, A.;
Wahhaj, Z.;
Beust, H.;
Bonnefoy, M.;
Chauvin, G.;
Desidera, S.;
Langlois, M.;
Henning, T.;
Janson, M.;
Olofsson, J.;
Rouan, D.;
Ménard, F.;
Lagrange, A. -M.;
Gratton, R.;
Vigan, A.;
Meyer, M. R.;
Cheetham, A.;
Beuzit, J. -L.;
Dohlen, K.;
Avenhaus, H.;
Bonavita, M.;
Claudi, R.;
Cudel, M.;
Daemgen, S.;
D'Orazi, V.;
Fontanive, C.;
Hagelberg, J.;
Coroller, H. Le;
Perrot, C.;
Rickman, E.;
Schmidt, T.;
Sissa, E.;
Udry, S.;
Zurlo, A.;
Abe, L.;
Origné, A.;
Rigal, F.;
Rousset, G.;
Roux, A.;
Weber, L.
Submitted: 2019-03-18, last modified: 2019-03-31
Context. The 51 Eridani system harbors a complex architecture with its
primary star forming a hierarchical system with the binary GJ 3305AB at a
projected separation of 2000 au, a giant planet orbiting the primary star at 13
au, and a low-mass debris disk around the primary star with possibly a cold
component and a warm component inferred from the spectral energy distribution.
Aims. We aim to better constrain the orbital parameters of the known giant
planet. Methods. We monitored the system over three years from 2015 to 2018
with the VLT/SPHERE exoplanet imaging instrument. Results. We measure an
orbital motion for the planet of ~130 mas with a slightly decreasing separation
(~10 mas) and find a hint of curvature. This potential curvature is further
supported at 3$\sigma$ significance when including literature GPI astrometry
corrected for calibration systematics. Fits of the SPHERE and GPI data using
three complementary approaches provide broadly similar results. The data
suggest an orbital period of 32$^{+17}_{-9}$ yr (i.e. 12$^{+4}_{-2}$ au in
semi-major axis), an inclination of 133$^{+14}_{-7}$ deg, an eccentricity of
0.45$^{+0.10}_{-0.15}$, and an argument of periastron passage of
87$^{+34}_{-30}$ deg [mod 180 deg]. The time at periastron passage and the
longitude of node exhibit bimodal distributions because we do not detect yet if
the planet is accelerating or decelerating along its orbit. Given the
inclinations of the planet's orbit and of the stellar rotation axis (134-144
deg), we infer alignment or misalignment within 18 deg for the star-planet
spin-orbit. Further astrometric monitoring in the next 3-4 years is required to
confirm at a higher significance the curvature in the planet's motion,
determine if the planet is accelerating or decelerating on its orbit, and
further constrain its orbital parameters and the star-planet spin-orbit.
[13]
oai:arXiv.org:1903.07516 [pdf] - 1850923
Apodized Pupil Lyot Coronagraphs with arbitrary aperture telescopes:
novel designs using hybrid focal plane masks
Submitted: 2019-03-18
Exoplanet imaging and spectroscopy are now routinely achieved by dedicated
instruments on large ground-based observatories (e.g. Gemini/GPI, VLT/SPHERE,
or Subaru/SCExAO). In addition to extreme adaptive optics (ExAO) and
post-processing methods, these facilities make use of the most advanced
coronagraphs to suppress light of an observed star and enable the observation
of circumstellar environments. The Apodized Pupil Lyot Coronagraph (APLC) is
one of the leading coronagraphic baseline in the current generation of
instruments. This concept combines a pupil apodization, an opaque focal plane
mask (FPM), and a Lyot stop. APLC can be optimized for a range of applications
and designs exist for on-axis segmented aperture telescopes at $10^{10}$
contrast in broadband light. In this communication, we propose novel designs to
push the limits of this concept further by modifying the nature of the FPM from
its standard opaque mask to a smaller size occulting spot surrounded by
circular phase shifting zones. We present the formalism of this new concept
which solutions find two possible applications: 1) upgrades for the current
generation of ExAO coronagraphs since these solutions remain compatible with
the existing designs and will provide better inner working angle, contrast and
throughput, and 2) coronagraphy at $10^{10}$ contrast for future flagship
missions such as LUVOIR, with the goal to increase the throughput of the
existing designs for the observation of Earth-like planets around nearby stars.
[14]
oai:arXiv.org:1903.06599 [pdf] - 1850033
Adaptive optics with programmable Fourier-based wavefront sensors: a
spatial light modulator approach to the LOOPS testbed
Janin-Potiron, Pierre;
Chambouleyron, Vincent;
Schatz, Lauren;
Fauvarque, Olivier;
Bond, Charlotte Z.;
Abautret, Yannick;
Muslimov, Eduard;
El-Hadi, Kacem;
Sauvage, Jean-François;
Dohlen, Kjetil;
Neichel, Benoît;
Correia, Carlos M.;
Fusco, Thierry
Submitted: 2019-03-15
Wavefront sensors encode phase information of an incoming wavefront into an
intensity pattern that can be measured on a camera. Several kinds of wavefront
sensors (WFS) are used in astronomical adaptive optics. Amongst them,
Fourier-based wavefront sensors perform a filtering operation on the wavefront
in the focal plane. The most well known example of a WFS of this kind is the
Zernike wavefront sensor, and the pyramid wavefront sensor (PWFS) also belongs
to this class. Based on this same principle, new WFSs can be proposed such as
the n-faced pyramid (which ultimately becomes an axicone) or the flattened
pyramid, depending on whether the image formation is incoherent or coherent. In
order to test such novel concepts, the LOOPS adaptive optics testbed hosted at
the Laboratoire d'Astrophysique de Marseille has been upgraded by adding a
Spatial Light Modulator (SLM). This device, placed in a focal plane produces
high-definition phase masks that mimic otherwise bulk optic devices. In this
paper, we first present the optical design and upgrades made to the
experimental setup of the LOOPS bench. Then, we focus on the generation of the
phase masks with the SLM and the implications of having such a device in a
focal plane. Finally, we present the first closed-loop results in either static
or dynamic mode with different WFS applied on the SLM.
[15]
oai:arXiv.org:1901.04050 [pdf] - 1814326
Key Technologies for the Wide Field Infrared Survey Telescope
Coronagraph Instrument
Bailey, Vanessa P.;
Armus, Lee;
Balasubramanian, Bala;
Baudoz, Pierre;
Bellini, Andrea;
Benford, Dominic;
Berriman, Bruce;
Bhattacharya, Aparna;
Boccaletti, Anthony;
Cady, Eric;
Novati, Sebastiano Calchi;
Carpenter, Kenneth;
Ciardi, David;
Crill, Brendan;
Danchi, William;
Debes, John;
Demers, Richard;
Dohlen, Kjetil;
Effinger, Robert;
Ferrari, Marc;
Frerking, Margaret;
Gelino, Dawn;
Girard, Julien;
Grady, Kevin;
Groff, Tyler;
Harding, Leon;
Helou, George;
Henning, Avenhaus;
Janson, Markus;
Kalirai, Jason;
Kane, Stephen;
Kasdin, N. Jeremy;
Kenworthy, Matthew;
Kern, Brian;
Krist, John;
Kruk, Jeffrey;
Lagrange, Anne Marie;
Laine, Seppo;
Langlois, Maud;
Coroller, Herve Le;
Lindensmith, Chris;
Lowrance, Patrick;
Maire, Anne-Lise;
Malhotra, Sangeeta;
Mandell, Avi;
McElwain, Michael;
Prada, Camilo Mejia;
Mennesson, Bertrand;
Meshkat, Tiffany;
Moody, Dwight;
Morrissey, Patrick;
Moustakas, Leonidas;
N'Diaye, Mamadou;
Nemati, Bijan;
Noecker, Charley;
Paladini, Roberta;
Perrin, Marshall;
Poberezhskiy, Ilya;
Postman, Marc;
Pueyo, Laurent;
Ramirez, Solange;
Ranc, Clement;
Rhodes, Jason;
Riggs, A. J. E.;
Rizzo, Maxime;
Roberge, Aki;
Rouan, Daniel;
Schlieder, Joshua;
Seo, Byoung-Joon;
Shaklan, Stuart;
Shi, Fang;
Soummer, Remi;
Spergel, David;
Stapelfeldt, Karl;
Stark, Christopher;
Tamura, Motohide;
Tang, Hong;
Trauger, John;
Turnbull, Margaret;
van der Marel, Roeland;
Vigan, Arthur;
Williams, Benjamin;
Wollack, Edward J.;
Ygouf, Marie;
Zhao, Feng;
Zhoud, Hanying;
Zimmerman, Neil
Submitted: 2019-01-13
The Wide Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument
(CGI) is a high-contrast imager and integral field spectrograph that will
enable the study of exoplanets and circumstellar disks at visible wavelengths.
Ground-based high-contrast instrumentation has fundamentally limited
performance at small working angles, even under optimistic assumptions for
30m-class telescopes. There is a strong scientific driver for better
performance, particularly at visible wavelengths. Future flagship mission
concepts aim to image Earth analogues with visible light flux ratios of more
than 10^10. CGI is a critical intermediate step toward that goal, with a
predicted 10^8-9 flux ratio capability in the visible. CGI achieves this
through improvements over current ground and space systems in several areas:
(i) Hardware: space-qualified (TRL9) deformable mirrors, detectors, and
coronagraphs, (ii) Algorithms: wavefront sensing and control; post-processing
of integral field spectrograph, polarimetric, and extended object data, and
(iii) Validation of telescope and instrument models at high accuracy and
precision. This white paper, submitted to the 2018 NAS Exoplanet Science
Strategy call, describes the status of key CGI technologies and presents ways
in which performance is likely to evolve as the CGI design matures.
[16]
oai:arXiv.org:1809.08354 [pdf] - 1818680
Post conjunction detection of $\beta$ Pictoris b with VLT/SPHERE
Lagrange, A. -M.;
Boccaletti, A.;
Langlois, M.;
Chauvin, G.;
Gratton, R.;
Beust, H.;
Desidera, S.;
Milli, J.;
Bonnefoy, M.;
Cheetham, A.;
Feldt, M.;
Meyer, M.;
Vigan, A.;
Biller, B.;
Bonavita, M.;
Baudino, J. -L.;
Cantalloube, F.;
Cudel, M.;
Daemgen, S.;
Delorme, P.;
D'Orazi, V.;
Girard, J.;
Fontanive, C.;
Hagelberg, J.;
Janson, M.;
Keppler, M.;
Koypitova, T.;
Galicher, R.;
Lannier, J.;
Coroller, H. Le;
Ligi, R.;
Maire, A. -L.;
Mesa, D.;
Messina, S.;
Mueller, A.;
Peretti, S.;
Perrot, C.;
Rouan, D.;
Salter, G.;
Samland, M.;
Schmidt, T.;
Sissa, E.;
Zurlo, A.;
Beuzit, J. -L.;
Mouillet, D.;
Dominik, C.;
Henning, T.;
Lagadec, E.;
Menard, F.;
Schmid, H. -M.;
Turatto, M.;
Udry, S.;
Bohn, A. J.;
Charnay, B.;
Gonzales, C. A. Gomez;
Gry, C.;
Kenworthy, M.;
Kral, Q.;
Mordasini, C.;
Moutou, C.;
van der Plas, G.;
Schlieder, J. E.;
Abe, L.;
Antichi, J.;
Baruffolo, A.;
Baudoz, P.;
Baudrand, J.;
Blanchard, P.;
Bazzon, A.;
Buey, T.;
Carbillet, M.;
Carle, M.;
Charton, J.;
Cascone, E.;
Claudi, R.;
Costille, A.;
Deboulbe, A.;
de Caprio, V.;
Dohlen, K.;
Fantinel, D.;
Feautrier, P.;
Fusco, T.;
Gigan, P.;
Giro, E.;
Gisler, D.;
Gluck, L.;
Hubin, N.;
Hugot, E.;
Jaquet, M.;
Kasper, M.;
Madec, F.;
Magnard, Y.;
Martinez, P.;
Maurel, D.;
Mignant, D. Le;
Moller-Nilsson, O.;
Llored, M.;
Moulin, T.;
Origne, A.;
Pavlov, A.;
Perret, D.;
Petit, C.;
Pragt, J.;
Szulagyi, J.;
Wildi, F.
Submitted: 2018-09-21, last modified: 2018-12-10
With an orbital distance comparable to that of Saturn in the solar system,
\bpic b is the closest (semi-major axis $\simeq$\,9\,au) exoplanet that has
been imaged to orbit a star. Thus it offers unique opportunities for detailed
studies of its orbital, physical, and atmospheric properties, and of
disk-planet interactions. With the exception of the discovery observations in
2003 with NaCo at the Very Large Telescope (VLT), all following astrometric
measurements relative to \bpic have been obtained in the southwestern part of
the orbit, which severely limits the determination of the planet's orbital
parameters. We aimed at further constraining \bpic b orbital properties using
more data, and, in particular, data taken in the northeastern part of the
orbit.
We used SPHERE at the VLT to precisely monitor the orbital motion of beta
\bpic b since first light of the instrument in 2014. We were able to monitor
the planet until November 2016, when its angular separation became too small
(125 mas, i.e., 1.6\,au) and prevented further detection. We redetected \bpic b
on the northeast side of the disk at a separation of 139\,mas and a PA of
30$^{\circ}$ in September 2018. The planetary orbit is now well constrained.
With a semi-major axis (sma) of $a = 9.0 \pm 0.5$ au (1 $\sigma $), it
definitely excludes previously reported possible long orbital periods, and
excludes \bpic b as the origin of photometric variations that took place in
1981. We also refine the eccentricity and inclination of the planet. From an
instrumental point of view, these data demonstrate that it is possible to
detect, if they exist, young massive Jupiters that orbit at less than 2 au from
a star that is 20 pc away.
[17]
oai:arXiv.org:1810.13171 [pdf] - 1795863
Origin of the asymmetry of the wind driven halo observed in high
contrast images
Cantalloube, F.;
Por, E;
Dohlen, K.;
Sauvage, J. -F;
Vigan, A;
Kasper, M;
Bharmal, N.;
Henning, Th;
Brandner, W;
Milli, J;
Correia, C;
Fusco, T
Submitted: 2018-10-31
The latest generation of high contrast instruments dedicated to exoplanets
and circumstellar disks imaging are equipped with extreme adaptive optics and
coronagraphs to reach contrasts of up to 10^--4 at a few tenths of arc-seconds
in the near infrared. The resulting image shows faint features, only revealed
with this combination, such as the wind driven halo. The wind driven halo is
due to the lag between the adaptive optics correction and the turbulence speed
over the telescope pupil. However we observe an asymmetry of this wind driven
halo that was not expected when the instrument was designed. In this letter, we
describe and demonstrate the physical origin of this asymmetry and support our
explanation by simulating the asymmetry with an end-to-end approach. From this
work, we found out that the observed asymmetry is explained by the interference
between the AO-lag error and scintillation effects, mainly originating from the
fast jet stream layer located at about 12 km in altitude. Now identified and
interpreted, this effect can be taken into account for further design of high
contrast imaging simulators, next generation or upgrade of high contrast
instruments, predictive control algorithms for adaptive optics or image
post-processing techniques.
[18]
oai:arXiv.org:1809.08839 [pdf] - 1755233
Sensing and control of segmented mirrors with a pyramid wavefront sensor
in the presence of spiders
Schwartz, Noah;
Sauvage, Jean-François;
Correia, Carlos;
Petit, Cyril;
Quiros-Pacheco, Fernando;
Fusco, Thierry;
Dohlen, Kjetil;
Hadi, Kacem El;
Thatte, Niranjan;
Clarke, Fraser;
Paufique, Jérome;
Vernet, Joel
Submitted: 2018-09-24
The segmentation of the telescope pupil (by spiders & the segmented M4)
create areas of phase isolated by the width of the spiders on the wavefront
sensor (WFS), breaking the spatial continuity of the wavefront. The poor
sensitivity of the Pyramid WFS (PWFS) to differential piston leads to badly
seen and therefore uncontrollable differential pistons. In close loop
operation, differential pistons between segments will settle around integer
values of the average sensing wavelength. The differential pistons typically
range from one to ten times the sensing wavelength and vary rapidly over time,
leading to extremely poor performance. In addition, aberrations created by
atmospheric turbulence will contain large amounts of differential piston
between the segments. Removing piston contribution over each of the DM segments
leads to poor performance. In an attempt to reduce the impact of unwanted
differential pistons that are injected by the AO correction, we compare three
different approaches. We first limit ourselves to only use the information
measured by the PWFS, in particular by reducing the modulation. We show that
using this information sensibly is important but will not be sufficient. We
discuss possible ways of improvement by using prior information. A second
approach is based on phase closure of the DM commands and assumes the
continuity of the correction wavefront over the entire unsegmented pupil. The
last approach is based on the pair-wise slaving of edge actuators and shows the
best results. We compare the performance of these methods using realistic
end-to-end simulations. We find that pair-wise slaving leads to a small
increase of the total wavefront error, only adding between 20-45 nm RMS in
quadrature for seeing conditions between 0.45-0.85 arcsec. Finally, we discuss
the possibility of combining the different proposed solutions to increase
robustness.
[19]
oai:arXiv.org:1808.05008 [pdf] - 1779605
SPHERE / ZIMPOL high resolution polarimetric imager. I. System overview,
PSF parameters, coronagraphy, and polarimetry
Schmid, H. M.;
Bazzon, A.;
Roelfsema, R.;
Mouillet, D.;
Milli, J.;
Menard, F.;
Gisler, D.;
Hunziker, S.;
Pragt, J.;
Dominik, C.;
Boccaletti, A.;
Ginski, C.;
Abe, L.;
Antoniucci, S.;
Avenhaus, H.;
Baruffolo, A.;
Baudoz, P.;
Beuzit, J. L.;
Carbillet, M.;
Chauvin, G.;
Claudi, R.;
Costille, A.;
Daban, J. B.;
de Haan, M.;
Desidera, S.;
Dohlen, K.;
Downing, M.;
Elswijk, E.;
Engler, N.;
Feldt, M.;
Fusco, T.;
Girard, J. H.;
Gratton, R.;
Hanenburg, H.;
Henning, Th.;
Hubin, N.;
Joos, F.;
Kasper, M.;
Keller, C. U.;
Langlois, M.;
Lagadec, E.;
Martinez, P.;
Mulder, E.;
Pavlov, A.;
Podio, L.;
Puget, P.;
Quanz, S.;
Rigal, F.;
Salasnich, B.;
Sauvage, J. F.;
Schuil, M.;
Siebenmorgen, R.;
Sissa, E.;
Snik, F.;
Suarez, M.;
Thalmann, Ch.;
Turatto, M.;
Udry, S.;
van Duin, A.;
van Holstein, R.;
Vigan, A.;
Wildi, F.
Submitted: 2018-08-15
We describe the Zurich Imaging Polarimeter (ZIMPOL), the visual focal plane
subsystem of the SPHERE "VLT planet finder", which pushes the limits of current
AO systems to shorter wavelengths, higher spatial resolution, and much improved
polarimetric performance. We provide new benchmarks for the performance of high
contrast instruments, in particular for polarimetric differential imaging. We
have analyzed SPHERE/ZIMPOL point spread functions and measure the peak surface
brightness, the encircled energy, and the full width half maximum (FWHM) for
different wavelengths, atmospheric conditions, star brightness, and instrument
modes. Coronagraphic images are described and analized and the performance for
different coronagraphs is compared with tests for the binary alpha Hyi with a
separation of 92 mas and a contrast of 6 mag. For the polarimetric mode we made
the instrument calibrations using zero polarization and high polarization
standard stars and here we give a recipe for the absolute calibration of
polarimetric data. The data show a small <1 mas but disturbing differential
polarimetric beam shifts, which can be explained as Goos-H\"ahnchen shifts from
the inclined mirrors, and we discuss how to correct this effect. The
polarimetric sensitivity is investigated with non-coronagraphic and deep,
coronagraphic observations of the dust scattering around the symbiotic Mira
variable R Aqr. SPHERE/ZIMPOL achieves imaging performances in the visual range
with unprecedented characteristics, in particular very high spatial resolution
and very high polarimetric contrast. This instrument opens up many new research
opportunities for the detailed investigation of circumstellar dust, in
scattered and therefore polarized light, for the investigation of faint
companions, and for the mapping of circumstellar Halpha emission.
[20]
oai:arXiv.org:1807.09852 [pdf] - 1723026
Phase masks in astronomy: From the Mach-Zehnder interferometer to
Coronographs
Submitted: 2018-07-25
Phase masks have numerous applications in astronomical optics, in particular
related to two themes: coronography for detection and analysis of extrasolar
planets or circumstellar disks, and wavefront analysis for extremely precise
adaptive optics systems or cophasing of segmented mirrors. I review some of the
literature concerning phase masks and attempt to bridge the gap between two
instrumental systems in which they are often found: the Mach-Zehnder
interferometer and the coronograph.
[21]
oai:arXiv.org:1806.11568 [pdf] - 1747971
Discovery of a planetary-mass companion within the gap of the transition
disk around PDS 70
Keppler, M.;
Benisty, M.;
Müller, A.;
Henning, Th.;
van Boekel, R.;
Cantalloube, F.;
Ginski, C.;
van Holstein, R. G.;
Maire, A. -L.;
Pohl, A.;
Samland, M.;
Avenhaus, H.;
Baudino, J. -L.;
Boccaletti, A.;
de Boer, J.;
Bonnefoy, M.;
Chauvin, G.;
Desidera, S.;
Langlois, M.;
Lazzoni, C.;
Marleau, G.;
Mordasini, C.;
Pawellek, N.;
Stolker, T.;
Vigan, A.;
Zurlo, A.;
Birnstiel, T.;
Brandner, W.;
Feldt, M.;
Flock, M.;
Girard, J.;
Gratton, R.;
Hagelberg, J.;
Isella, A.;
Janson, M.;
Juhasz, A.;
Kemmer, J.;
Kral, Q.;
Lagrange, A. -M.;
Launhardt, R.;
Matter, A.;
Ménard, F.;
Milli, J.;
Mollière, P.;
Olofsson, J.;
Perez, L.;
Pinilla, P.;
Pinte, C.;
Quanz, S. P.;
Schmidt, T.;
Udry, S.;
Wahhaj, Z.;
Williams, J. P.;
Buenzli, E.;
Cudel, M.;
Dominik, C.;
Galicher, R.;
Kasper, M.;
Lannier, J.;
Mesa, D.;
Mouillet, D.;
Peretti, S.;
Perrot, C.;
Salter, G.;
Sissa, E.;
Wildi, F.;
Abe, L.;
Antichi, J.;
Augereau, J. -C.;
Baruffolo, A.;
Baudoz, P.;
Bazzon, A.;
Beuzit, J. -L.;
Blanchard, P.;
Brems, S. S.;
Buey, T.;
De Caprio, V.;
Carbillet, M.;
Carle, M.;
Cascone, E.;
Cheetham, A.;
Claudi, R.;
Costille, A.;
Delboulbé, A.;
Dohlen, K.;
Fantinel, D.;
Feautrier, P.;
Fusco, T.;
Giro, E.;
Gisler, D.;
Gluck, L.;
Gry, C.;
Hubin, N.;
Hugot, E.;
Jaquet, M.;
Mignant, D. Le;
Llored, M.;
Madec, F.;
Magnard, Y.;
Martinez, P.;
Maurel, D.;
Meyer, M.;
Moeller-Nilsson, O.;
Moulin, T.;
Mugnier, L.;
Origne, A.;
Pavlov, A.;
Perret, D.;
Petit, C.;
Pragt, J.;
Puget, P.;
Rabou, P.;
Ramos, J.;
Rigal, F.;
Rochat, S.;
Roelfsema, R.;
Rousset, G.;
Roux, A.;
Salasnich, B.;
Sauvage, J. -F.;
Sevin, A.;
Soenke, C.;
Stadler, E.;
Suarez, M.;
Turatto, M.;
Weber, L.
Submitted: 2018-06-29, last modified: 2018-07-12
Young circumstellar disks are of prime interest to understand the physical
and chemical conditions under which planet formation takes place. Only very few
detections of planet candidates within these disks exist, and most of them are
currently suspected to be disk features. In this context, the transition disk
around the young star PDS 70 is of particular interest, due to its large gap
identified in previous observations, indicative of ongoing planet formation. We
aim to search for the presence of planets and search for disk structures
indicative for disk-planet interactions and other evolutionary processes. We
analyse new and archival near-infrared (NIR) images of the transition disk PDS
70 obtained with the VLT/SPHERE, VLT/NaCo and Gemini/NICI instruments in
polarimetric differential imaging (PDI) and angular differential imaging (ADI)
modes. We detect a point source within the gap of the disk at about 195 mas
(about 22 au) projected separation. The detection is confirmed at five
different epochs, in three filter bands and using different instruments. The
astrometry results in an object of bound nature, with high significance. The
comparison of the measured magnitudes and colours to evolutionary tracks
suggests that the detection is a companion of planetary mass. We confirm the
detection of a large gap of about 54 au in size within the disk in our
scattered light images, and detect a signal from an inner disk component. We
find that its spatial extent is very likely smaller than about 17 au in radius.
The images of the outer disk show evidence of a complex azimuthal brightness
distribution which may in part be explained by Rayleigh scattering from very
small grains. Future observations of this system at different wavelengths and
continuing astrometry will allow us to test theoretical predictions regarding
planet-disk interactions, planetary atmospheres and evolutionary models.
[22]
oai:arXiv.org:1807.04018 [pdf] - 1717253
SPHERE on-sky performance compared with budget predictions
Dohlen, Kjetil;
Vigan, Arthur;
Mouillet, David;
Wildi, Francois;
Sauvage, Jean-Francois;
Fusco, Thierry;
Beuzit, Jean-Luc;
Puget, Pascal;
Mignant, David Le;
Roelfsema, Ronald;
Pragt, Johan;
Schmid, Hands Martin;
Gratton, Raffaele;
Mesa, Dino;
Claudi, Riccardo;
Langlois, Maud;
Costille, Anne;
Hugot, Emmanuel;
O'Neil, Jared;
Guerra, Juan Carlos;
N'Diaye, Mamadou;
Girard, Julien;
Mawet, Dimitri;
Zins, Gerard
Submitted: 2018-07-11
The SPHERE (spectro-photometric exoplanet research) extreme-AO planet hunter
saw first light at the VLT observatory on Mount Paranal in May 2014 after ten
years of development. Great efforts were put into modelling its performance,
particularly in terms of achievable contrast, and to budgeting instrumental
features such as wave front errors and optical transmission to each of the
instrument's three focal planes, the near infrared dual imaging camera IRDIS,
the near infrared integral field spectrograph IFS and the visible polarimetric
camera ZIMPOL. In this paper we aim at comparing predicted performance with
measured performance. In addition to comparing on-sky contrast curves and
calibrated transmission measurements, we also compare the PSD-based wave front
error budget with in-situ wave front maps obtained thanks to a Zernike phase
mask, ZELDA, implemented in the infrared coronagraph wheel. One of the most
critical elements of the SPHERE system is its high-order deformable mirror, a
prototype 40x40 actuator piezo stack design developed in parallel with the
instrument itself. The development was a success, as witnessed by the
instrument performance, in spite of some bad surprises discovered on the way.
The devastating effects of operating without taking properly into account the
loss of several actuators and the thermally and temporally induced variations
in the DM shape will be analysed, and the actions taken to mitigate these
defects through the introduction of specially designed Lyot stops and
activation of one of the mirrors in the optical train will be described.
[23]
oai:arXiv.org:1807.00720 [pdf] - 1712254
The ELT-MOS (MOSAIC): towards the construction phase
Morris, Simon;
Hammer, François;
Jagourel, Pascal;
Evans, Christopher J.;
Puech, Mathieu;
Dalton, Gavin B.;
Rodrigues, Myriam;
Sanchez-Janssen, Ruben;
Fitzsimons, Ewan;
Barbuy, Beatriz;
Cuby, Jean-Gabriel;
Kaper, Lex;
Roth, Martin;
Rousset, Gérard;
Myers, Richard;
Fèvre, Olivier Le;
Finogenov, Alexis;
Kotilainen, Jari;
Castilho, Bruno;
Ostlin, Goran;
Feltzing, Sofia;
Korn, Andreas;
Gallego, Jesus;
Morales, África Castillo;
Iglesias-Páramo, Jorge;
Pentericci, Laura;
Ziegler, Bodo;
Afonso, Jose;
Dubbledam, Marc;
Close, Madeline;
Parr-Burman, Phil;
Morris, Timothy J.;
Chemla, Fanny;
De Frondat, Fatima;
Kelz, Andreas;
Guinouard, Isabelle;
Lewis, Ian J.;
Middleton, Kevin;
Navarro, Ramon;
Pragt, Marie LarrieuJohan;
Janssen, Annemieke;
Dohlen, Kjetil;
Hadi, Kacem El;
Gendron, Éric;
Yang, Yanbin;
Wells, Martyn;
Conan, Jean-Marc;
Fusco, Thierry;
Schaerer, Daniel;
Bergin, Ted;
Taburet, Sylvestre;
Frotin, Mickaël;
Berkourn, Nadia
Submitted: 2018-07-02, last modified: 2018-07-09
When combined with the huge collecting area of the ELT, MOSAIC will be the
most effective and flexible Multi-Object Spectrograph (MOS) facility in the
world, having both a high multiplex and a multi-Integral Field Unit (Multi-IFU)
capability. It will be the fastest way to spectroscopically follow-up the
faintest sources, probing the reionisation epoch, as well as evaluating the
evolution of the dwarf mass function over most of the age of the Universe.
MOSAIC will be world-leading in generating an inventory of both the dark matter
(from realistic rotation curves with MOAO fed NIR IFUs) and the cool to
warm-hot gas phases in z=3.5 galactic haloes (with visible wavelenth IFUs).
Galactic archaeology and the first massive black holes are additional targets
for which MOSAIC will also be revolutionary. MOAO and accurate sky subtraction
with fibres have now been demonstrated on sky, removing all low Technical
Readiness Level (TRL) items from the instrument. A prompt implementation of
MOSAIC is feasible, and indeed could increase the robustness and reduce risk on
the ELT, since it does not require diffraction limited adaptive optics
performance. Science programmes and survey strategies are currently being
investigated by the Consortium, which is also hoping to welcome a few new
partners in the next two years.
[24]
oai:arXiv.org:1710.05417 [pdf] - 1708277
Performance of the extreme-AO instrument VLT/SPHERE and dependence on
the atmospheric conditions
Milli, J.;
Mouillet, D.;
Fusco, T.;
Girard, J. H.;
Masciadri, E.;
Pena, E.;
Sauvage, J. -F.;
Reyes, C.;
Dohlen, K.;
Beuzit, J. -L.;
Kasper, M.;
Sarazin, M.;
Cantalloube, F.
Submitted: 2017-10-15, last modified: 2018-07-02
SPHERE is the high-contrast exoplanet imager and spectrograph installed at
the Unit Telescope 3 of the Very Large Telescope. After more than two years of
regular operations, we analyse statistically the performance of the adaptive
optics system and its dependence on the atmospheric conditions above the
Paranal observatory, as measured by the suite of dedicated instruments which
are part of the Astronomical Site Monitor and as estimated by the SPHERE
real-time calculator. We also explain how this information can be used to
schedule the observations in order to yield the best data quality and to guide
the astronomer when processing his/her data.
[25]
oai:arXiv.org:1807.00073 [pdf] - 1708624
Opto-mechanical designs for the HARMONI Adaptive Optics systems
Dohlen, Kjetil;
Morris, Timothy;
Lopez, Javier Piqueras;
Calcines-Rosario, Ariadna;
Costille, Anne;
Dubbeldam, Marc;
Hadi, Kacem El;
Fusco, Thierry;
Llored, Marc;
Neichel, Benoit;
Pascal, Sandrine;
Sauvage, Jean-Francois;
Vola, Pascal;
Clarke, Fraser;
Schnetler, Hermine;
Bryson, Ian;
Thatte, Niranjan
Submitted: 2018-06-29
HARMONI is a visible and near-infrared integral field spectrograph equipped
with two complementary adaptive optics systems, fully integrated within the
instrument. A Single Conjugate AO (SCAO) system offers high performance for a
limited sky coverage and a Laser Tomographic AO (LTAO) system provides AO
correction with a very high sky-coverage. While the deformable mirror
performing real-time correction of the atmospheric disturbances is located
within the telescope itself, the instrument contains a suite of
state-of-the-art and innovative wavefront sensor systems. Laser guide star
sensors (LGSS) are located at the entrance of the instrument and fed by a
dichroic beam splitter, while the various natural guide star sensors for LTAO
and SCAO are located close to the science focal plane. We present
opto-mechanical architecture and design at PDR level for these wavefront sensor
systems.
[26]
oai:arXiv.org:1806.06158 [pdf] - 1706590
On-sky compensation of non-common path aberrations with the ZELDA
wavefront sensor in VLT/SPHERE
Vigan, A.;
N'Diaye, M.;
Dohlen, K.;
Milli, J.;
Wahhaj, Z.;
Sauvage, J. -F.;
Beuzit, J. -L.;
Pourcelot, R.;
Mouillet, D.;
Zins, G.
Submitted: 2018-06-15, last modified: 2018-06-27
Circumstellar environments are now routinely observed by dedicated
high-contrast imagers on large, ground-based observatories. These facilities
combine extreme adaptive optics and coronagraphy to achieve unprecedented
sensitivities for exoplanet detection and spectral characterization. However,
non-common path aberrations (NCPA) in these coronagraphic systems represent a
critical limitation for the detection of giant planets with a contrast lower
than a few $10^{-6}$ at very small separations ($<$0.3$^{\prime\prime}$) from
their host star. In 2013 we proposed ZELDA, a Zernike wavefront sensor to
measure these residual quasi-static phase aberrations and a prototype was
installed in SPHERE, the exoplanet imager for the VLT. In 2016, we demonstrated
the ability of our sensor to provide a nanometric calibration and compensation
for these aberrations on an internal source in the instrument, resulting in a
contrast gain of 10 at 0.2$^{\prime\prime}$ in coronagraphic images. However,
initial on-sky tests in 2017 did not show a tangible gain in contrast when
calibrating the NCPA internally and then applying the correction on sky. In
this communication, we present recent on-sky measurements to demonstrate the
potential of our sensor for the NCPA compensation during observations and
quantify the contrast gain in coronagraphic data.
[27]
oai:arXiv.org:1806.10618 [pdf] - 1707150
Bringing high-spectral resolution to VLT/SPHERE with a fibre coupling to
VLT/CRIRES+
Vigan, A.;
Otten, G. P. P. L.;
Muslimov, E.;
Dohlen, K.;
Phillips, M. W.;
Seemann, U.;
Beuzit, J. -L.;
Dorn, R.;
Kasper, M.;
Mouillet, D.;
Baraffe, I.;
Reiners, A.
Submitted: 2018-06-27
Atmospheric composition provides essential markers of the most fundamental
properties of giant exoplanets, such as their formation mechanism or internal
structure. New-generation exoplanet imagers, like VLT/SPHERE or Gemini/GPI,
have been designed to achieve very high contrast (>15 mag) at small angular
separations ($<$0.5\as) for the detection of young giant planets in the
near-infrared, but they only provide very low spectral resolutions ($R<100$)
for their characterization. High-dispersion spectroscopy at resolutions up to
$10^5$ is one of the most promising pathways for the detailed characterization
of exoplanets, but it is currently out of reach for most directly imaged
exoplanets because current high-dispersion spectrographs in the near-infrared
lack coronagraphs to attenuate the stellar signal and the spatial resolution
necessary to resolve the planet. Project HiRISE (High-Resolution Imaging and
Spectroscopy of Exoplanets) ambitions to develop a demonstrator that will
combine the capabilities of two flagship instruments installed on the ESO Very
Large Telescope, the high-contrast exoplanet imager SPHERE and the
high-resolution spectrograph CRIRES+, with the goal of answering fundamental
questions on the formation, composition and evolution of young planets. In this
work, we will present the project, the first set of realistic simulations and
the preliminary design of the fiber injection unit that will be implemented in
SPHERE.
[28]
oai:arXiv.org:1805.11931 [pdf] - 1691645
The adaptive optics modes for HARMONI: from Classical to Laser Assisted
Tomographic AO
Neichel, B.;
Fusco, T.;
Sauvage, J. -F.;
Correia, C.;
Dohlen, K.;
El-Hadi, K.;
Blanco, L.;
Schwartz, N.;
Clarke, F.;
Thatte, N.;
Tecza, M.;
Paufique, J.;
Vernet, J.;
Louarn, M. Le;
Hammersley, P.;
Gach, J. -L.;
Pascal, S.;
Vola, P.;
Petit, C.;
Conan, J. -M.;
Carlotti, A.;
Verinaud, C.;
Schnetler, H.;
Bryson, I.;
Morris, T.;
Myers, R.;
Hugot, E.;
Gallie, A.
Submitted: 2018-05-30
HARMONI is a visible and NIR integral field spectrograph, providing the
E-ELT's core spectroscopic capability at first light. HARMONI will work at the
diffraction limit of the E-ELT, thanks to a Classical and a Laser Tomographic
AO system. In this paper, we present the system choices that have been made for
these SCAO and LTAO modules. In particular, we describe the strategy developed
for the different Wave-Front Sensors: pyramid for SCAO, the LGSWFS concept, the
NGSWFS path, and the truth sensor capabilities. We present first potential
implementations. And we asses the first system performance.
[29]
oai:arXiv.org:1804.02192 [pdf] - 1724929
K-Stacker: Keplerian image recombination for the direct detection of
exoplanets
Submitted: 2018-04-06
We present a proof of concept for a new algorithm which can be used to detect
exoplanets in high contrast images. The algorithm properly combines mutliple
observations acquired during different nights, taking into account the orbital
motion of the planet. Methods. We simulate SPHERE/IRDIS time series of
observations in which we blindly inject planets on random orbits, at random
level of S/N, below the detection limit (down to S/N 1.5). We then use an
optimization algorithm to guess the orbital parameters, and take into account
the orbital motion to properly recombine the different images, and eventually
detect the planets. We show that an optimization algorithm can indeed be used
to find undetected planets in temporal sequences of images, even if they are
spread over orbital time scales. As expected, the typical gain in S/N ratio is
sqrt(n), n being the number of observations combined. We find that the
K-Stacker algorithm is able de-orbit and combine the images to reach a level of
performance similar to what could be expected if the planet was not moving. We
find recovery rates of 50% at S/N=5. We also find that the algorithm is able to
determine the position of the planet in individual frames at one pixel
precision, even despite the fact that the planet itself is below the detection
limit in each frame. Our simulations show that K-Stacker can be used to
increase the contrast limit of current exoplanet imaging instruments and to
discover fainter bodies. We also suggest that the ability of K-Stacker to
determine the position of the planet in every image of the time serie could be
used as part of a new observing strategy in which long exposures would be
broken into shorter ones spread over months. This could make possible to
determine the orbital parameters of a planet without requiring multiple high
S/N > 5 detections.
[30]
oai:arXiv.org:1803.03258 [pdf] - 1717035
Laboratory verification of 'Fast & Furious' phase diversity: Towards
controlling the low wind effect in the SPHERE instrument
Submitted: 2018-03-08
The low wind effect (LWE) refers to a characteristic set of quasi-static
wavefront aberrations seen consistently by the SPHERE instrument when
dome-level wind speeds drop below 3 m/s. This effect produces bright low-order
speckles in the stellar PSF, which severely limit the contrast performance of
SPHERE under otherwise optimal observing conditions. In this paper we propose
the Fast & Furious (F&F) phase diversity algorithm as a viable software-only
solution for real-time LWE compensation, which would utilise image sequences
from the SPHERE differential tip-tilt sensor (DTTS). We evaluated the
closed-loop performance of F&F on the MITHIC high-contrast test-bench under a
variety of conditions emulating LWE-affected DTTS images, in order to assess
the expected performance of an on-sky implementation of F&F in SPHERE. The
algorithm was found to be capable of returning such LWE-affected images to
Strehl ratios of greater than 90% within five iterations, for all appropriate
laboratory test cases. These results are highly representative of predictive
simulations, and demonstrate the stability of the algorithm against a wide
range of factors including low image signal-to-noise ratio (S/N), small image
field of view, and amplitude errors. It was also found in simulation that
closed-loop stability can be preserved down to image S/N as low as five while
still improving overall wavefront quality, allowing for reliable operation even
on faint targets. The Fast & Furious algorithm is an extremely promising
solution for real-time compensation of the LWE, which can operate
simultaneously with science observations and may be implemented in SPHERE
without requiring additional hardware. The robustness and relatively large
effective dynamic range of F&F also make it suitable for general wavefront
optimisation applications, including the co-phasing of segmented ELT-class
telescopes.
[31]
oai:arXiv.org:1803.02725 [pdf] - 1724900
Discovery of a brown dwarf companion to the star HIP 64892
Cheetham, A.;
Bonnefoy, M.;
Desidera, S.;
Langlois, M.;
Vigan, A.;
Schmidt, T.;
Olofsson, J.;
Chauvin, G.;
Klahr, H.;
Gratton, R.;
D'Orazi, V.;
Henning, T.;
Janson, M.;
Biller, B.;
Peretti, S.;
Hagelberg, J.;
Ségransan, D.;
Udry, S.;
Mesa, D.;
Sissa, E.;
Kral, Q.;
Schlieder, J.;
Maire, A. -L.;
Mordasini, C.;
Menard, F.;
Zurlo, A.;
Beuzit, J. -L.;
Feldt, M.;
Mouillet, D.;
Meyer, M.;
Lagrange, A. -M.;
Boccaletti, A.;
Keppler, M.;
Kopytova, T.;
Ligi, R.;
Rouan, D.;
Coroller, H. Le;
Dominik, C.;
Lagadec, E.;
Turatto, M.;
Abe, L.;
Antichi, J.;
Baruffolo, A.;
Baudoz, P.;
Blanchard, P.;
Buey, T.;
Carbillet, M.;
Carle, M.;
Cascone, E.;
Claudi, R.;
Costille, A.;
Delboulbé, A.;
De Caprio, V.;
Dohlen, K.;
Fantinel, D.;
Feautrier, P.;
Fusco, T.;
Giro, E.;
Gluck, L.;
Hubin, N.;
Hugot, E.;
Jaquet, M.;
Kasper, M.;
Llored, M.;
Madec, F.;
Magnard, Y.;
Martinez, P.;
Maurel, D.;
Mignant, D. Le;
Möller-Nilsson, O.;
Moulin, T.;
Origné, A.;
Pavlov, A.;
Perret, D.;
Petit, C.;
Pragt, J.;
Puget, P.;
Rabou, P.;
Ramos, J.;
Rigal, F.;
Rochat, S.;
Roelfsema, R.;
Rousset, G.;
Roux, A.;
Salasnich, B.;
Sauvage, J. -F.;
Sevin, A.;
Soenke, C.;
Stadler, E.;
Suarez, M.;
Weber, L.;
Wildi, F.
Submitted: 2018-03-07
We report the discovery of a bright, brown dwarf companion to the star HIP
64892, imaged with VLT/SPHERE during the SHINE exoplanet survey. The host is a
B9.5V member of the Lower-Centaurus-Crux subgroup of the Scorpius Centaurus OB
association. The measured angular separation of the companion
($1.2705\pm0.0023$") corresponds to a projected distance of $159\pm12$ AU. We
observed the target with the dual-band imaging and long-slit spectroscopy modes
of the IRDIS imager to obtain its SED and astrometry. In addition, we
reprocessed archival NACO L-band data, from which we also recover the
companion. Its SED is consistent with a young (<30 Myr), low surface gravity
object with a spectral type of M9$_{\gamma}\pm1$. From comparison with the
BT-Settl atmospheric models we estimate an effective temperature of
$T_{\textrm{eff}}=2600 \pm 100$ K, and comparison of the companion photometry
to the COND evolutionary models yields a mass of $\sim29-37$ M$_{\text{J}}$ at
the estimated age of $16^{+15}_{-7}$ Myr for the system. HIP 64892 is a rare
example of an extreme-mass ratio system ($q\sim0.01$) and will be useful for
testing models relating to the formation and evolution of such low-mass
objects.
[32]
oai:arXiv.org:1707.01413 [pdf] - 1602556
Discovery of a warm, dusty giant planet around HIP65426
Chauvin, G.;
Desidera, S.;
Lagrange, A. -M.;
Vigan, A.;
Gratton, R.;
Langlois, M.;
Bonnefoy, M.;
Beuzit, J. -L.;
Feldt, M.;
Mouillet, D.;
Meyer, M.;
Cheetham, A.;
Biller, B.;
Boccaletti, A.;
D'Orazi, V.;
Galicher, R.;
Hagelberg, J.;
Maire, A. -L.;
Mesa, D.;
Olofsson, J.;
Samland, M.;
Schmidt, T. O. B.;
Sissa, E.;
Bonavita, M.;
Charnay, B.;
Cudel, M.;
Daemgen, S.;
Delorme, P.;
Janin-Potiron, P.;
Janson, M.;
Keppler, M.;
Coroller, H. Le;
Ligi, R.;
Marleau, G. D.;
Messina, S.;
Molliere, P.;
Mordasini, C.;
Muller, A.;
Peretti, S.;
Perrot, C.;
Rodet, L.;
Rouan, D.;
Zurlo, A.;
Dominik, C.;
Henning, T.;
Menard, F.;
Schmid, H. -M.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Abe, L.;
Antichi, J.;
Baruffolo, A.;
Baudoz, P.;
Baudrand, J.;
Blanchard, P.;
Bazzon, A.;
Buey, T.;
Carbillet, M.;
Carle, M.;
Charton, J.;
Cascone, E.;
Claudi, R.;
Costille, A.;
Deboulbe, A.;
De Caprio, V.;
Dohlen, K.;
Fantinel, D.;
Feautrier, P.;
Fusco, T.;
Gigan, P.;
Giro, E.;
Gisler, D.;
Gluck, L.;
Hubin, N.;
Hugot, E.;
Jaquet, M.;
Kasper, M.;
Madec, F.;
Magnard, Y.;
Martinez, P.;
Maurel, D.;
Mignant, D. Le;
Moller-Nilsson, O.;
Llored, M.;
Moulin, T.;
Origné, A.;
Pavlov, A.;
Perret, D.;
Petit, C.;
Pragt, J.;
Puget, P.;
Rabou, P.;
Ramos, J.;
Rigal, R.;
Rochat, S.;
Roelfsema, R.;
Rousset, G.;
Roux, A.;
Salasnich, B.;
Sauvage, J. -F.;
Sevin, A.;
Soenke, C.;
Stadler, E.;
Suarez, M.;
Weber, L.;
Wildi, F.;
Antoniucci, S.;
Augereau, J. -C.;
Baudino, J. -L.;
Brandner, W.;
Engler, N.;
Girard, J.;
Gry, C.;
Kral, Q.;
Kopytova, T.;
Lagadec, E.;
Milli, J.;
Moutou, C.;
Schlieder, J.;
Szulágyi, J.;
Thalmann, C.;
Wahhaj, Z.
Submitted: 2017-07-05, last modified: 2017-12-11
The SHINE program is a large high-contrast near-infrared survey of 600 young,
nearby stars. It is aimed at searching for and characterizing new planetary
systems using VLT/SPHERE's unprecedented high-contrast and high-angular
resolution imaging capabilities. It also intends at placing statistical
constraints on the occurrence and orbital properties of the giant planet
population at large orbits as a function of the stellar host mass and age to
test planet formation theories. We use the IRDIS dual-band imager and the IFS
integral field spectrograph of SPHERE to acquire high-constrast coronagraphic
differential near-infrared images and spectra of the young A2 star HIP65426. It
is a member of the ~17 Myr old Lower Centaurus-Crux association. At a
separation of 830 mas (92 au projected) from the star, we detect a faint red
companion. Multi-epoch observations confirm that it shares common proper motion
with HIP65426. Spectro-photometric measurements extracted with IFS and IRDIS
between 0.95 and 2.2um indicate a warm, dusty atmosphere characteristic of
young low surface-gravity L5-L7 dwarfs. Hot-start evolutionary models predict a
luminosity consistent with a 6-12 MJup, Teff=1300-1600 K and R=1.5 RJup giant
planet. Finally, the comparison with Exo-REM and PHOENIX BT-Settl synthetic
atmosphere models gives consistent effective temperatures but with slightly
higher surface gravity solutions of log(g)=4.0-5.0 with smaller radii (1.0-1.3
RJup). Given its physical and spectral properties, HIP65426b occupies a rather
unique placement in terms of age, mass and spectral-type among the currently
known imaged planets. It represents a particularly interesting case to study
the presence of clouds as a function of particle size, composition, and
location in the atmosphere, to search for signatures of non-equilibrium
chemistry, and finally to test the theory of planet formation and evolution.
[33]
oai:arXiv.org:1711.06329 [pdf] - 1591369
Design of pre-optics for laser guide star wavefront sensor for the ELT
Submitted: 2017-11-16
In the present paper, we consider the optical design of a zoom system for the
active refocusing in laser guide star wavefront sensors. The system is designed
according to the specifications coming from the Extremely Large Telescope
(ELT)-HARMONI instrument, the first-light, integral field spectrograph for the
European (E)-ELT. The system must provide a refocusing of the laser guide as a
function of telescope pointing and large decentring of the incoming beam. The
system considers four moving lens groups, each of them being a doublet with one
aspherical surface. The advantages and shortcomings of such a solution in terms
of the component displacements and complexity of the surfaces are described in
detail. It is shown that the system can provide the median value of the
residual wavefront error of 13.8-94.3 nm and the maximum value <206 nm, while
the exit pupil distortion is 0.26-0.36% for each of the telescope pointing
directions.
[34]
oai:arXiv.org:1709.00417 [pdf] - 1587822
The HIP 79977 debris disk in polarized light
Engler, N.;
Schmid, H. M.;
Thalmann, Ch.;
Boccaletti, A.;
Bazzon, A.;
Baruffolo, A.;
Beuzit, J. L.;
Claudi, R.;
Costille, A.;
Desidera, S.;
Dohlen, K.;
Dominik, C.;
Feldt, M.;
Fusco, T.;
Ginski, C.;
Gisler, D.;
Girard, J. H.;
Gratton, R.;
Henning, T.;
Hubin, N.;
Janson, M.;
Kasper, M.;
Kral, Q.;
Langlois, M.;
Lagadec, E.;
Ménard, F.;
Meyer, M. R.;
Milli, J.;
Mouillet, D.;
Olofsson, J.;
Pavlov, A.;
Pragt, J.;
Puget, P.;
Quanz, S. P.;
Roelfsema, R.;
Salasnich, B.;
Siebenmorgen, R.;
Sissa, E.;
Suarez, M.;
Szulagyi, J.;
Turatto, M.;
Udry, S.;
Wildi, F.
Submitted: 2017-09-01, last modified: 2017-09-07
We present observations of the known edge-on debris disk around HIP 79977 (HD
146897, F star in Upper Sco, 123 pc), taken with the ZIMPOL differential
polarimeter of the SPHERE instrument in the Very Broad Band filter
($\lambda_c=735$ nm, $\Delta\lambda=290$ nm) with a spatial resolution of about
25 mas. We measure the polarization flux along and perpendicular to the disk
spine of the highly inclined disk for projected separations between 0.2" (25
AU) and 1.6" (200 AU) and investigate the diagnostic potential of such data
with model simulations. The polarized flux contrast ratio for the disk is
$F_{pol}/F_\ast= (5.5 \pm 0.9) 10^{-4}$. The surface brightness reaches a
maximum of 16.2 mag arcsec$^{-2}$ at a separation of $0.2"-0.5"$ along the disk
spine with a maximum surface brightness contrast of 7.64 mag arcsec$^{-2}$. The
polarized flux has a minimum near the star $<0.2"$ because no or only little
polarization is produced by forward or backward scattering in the disk section
lying in front of or behind the star. The data are modeled as a circular dust
belt with an inclination $i=85(\pm 1.5)^\circ$ and a radius between $r_0$ = 60
AU and 90 AU. The radial density dependence is described by $(r/r_0)^{\alpha}$
with a steep power law index $\alpha=5$ inside $r_0$ and a more shallow index
$\alpha=-2.5$ outside $r_0$. The scattering asymmetry factor lies between $g$ =
0.2 and 0.6 adopting a scattering angle-dependence for the fractional
polarization as for Rayleigh scattering. Our data are qualitatively very
similar to the case of AU Mic and they confirm that edge-on debris disks have a
polarization minimum at a position near the star and a maximum near the
projected separation of the main debris belt. The comparison of the polarized
flux contrast ratio $F_{pol}/F_{\ast}$ with the fractional infrared excess
provides strong constraints on the scattering albedo of the dust.
[35]
oai:arXiv.org:1705.09680 [pdf] - 1583944
Exploring dust around HD142527 down to 0.025" / 4au using SPHERE/ZIMPOL
Avenhaus, H.;
Quanz, S. P.;
Schmid, H. M.;
Dominik, C.;
Stolker, T.;
Ginski, C.;
de Boer, J.;
Szulágyi, J.;
Garufi, A.;
Zurlo, A.;
Hagelberg, J.;
Benisty, M.;
Henning, T.;
Ménard, F.;
Meyer, M. R.;
Baruffolo, A.;
Bazzon, A.;
Beuzit, J. L.;
Costille, A.;
Dohlen, K.;
Girard, J. H.;
Gisler, D.;
Kasper, M.;
Mouillet, D.;
Pragt, J.;
Roelfsema, R.;
Salasnich, B.;
Sauvage, J. -F.
Submitted: 2017-05-26, last modified: 2017-06-23
We have observed the protoplanetary disk of the well-known young Herbig star
HD 142527 using ZIMPOL Polarimetric Differential Imaging with the VBB (Very
Broad Band, ~600-900nm) filter. We obtained two datasets in May 2015 and March
2016. Our data allow us to explore dust scattering around the star down to a
radius of ~0.025" (~4au). The well-known outer disk is clearly detected, at
higher resolution than before, and shows previously unknown sub-structures,
including spirals going inwards into the cavity. Close to the star, dust
scattering is detected at high signal-to-noise ratio, but it is unclear whether
the signal represents the inner disk, which has been linked to the two
prominent local minima in the scattering of the outer disk, interpreted as
shadows. An interpretation of an inclined inner disk combined with a dust halo
is compatible with both our and previous observations, but other arrangements
of the dust cannot be ruled out. Dust scattering is also present within the
large gap between ~30 and ~140au. The comparison of the two datasets suggests
rapid evolution of the inner regions of the disk, potentially driven by the
interaction with the close-in M-dwarf companion, around which no polarimetric
signal is detected.
[36]
oai:arXiv.org:1704.05501 [pdf] - 1565374
Fine cophasing of segmented aperture telescopes with ZELDA, a Zernike
wavefront sensor in the diffraction-limited regime
Submitted: 2017-04-18
Segmented aperture telescopes require an alignment procedure with successive
steps from coarse alignment to monitoring process in order to provide very high
optical quality images for stringent science operations such as exoplanet
imaging. The final step, referred to as fine phasing, calls for a high
sensitivity wavefront sensing and control system in a diffraction-limited
regime to achieve segment alignment with nanometric accuracy. In this context,
Zernike wavefront sensors represent promising options for such a calibration. A
concept called the Zernike unit for segment phasing (ZEUS) was previously
developed for ground-based applications to operate under seeing-limited images.
Such a concept is, however, not suitable for fine cophasing with
diffraction-limited images. We revisit ZELDA, a Zernike sensor that was
developed for the measurement of residual aberrations in exoplanet direct
imagers, to measure segment piston, tip, and tilt in the diffraction-limited
regime. We introduce a novel analysis scheme of the sensor signal that relies
on piston, tip, and tilt estimators for each segment, and provide probabilistic
insights to predict the success of a closed-loop correction as a function of
the initial wavefront error. The sensor unambiguously and simultaneously
retrieves segment piston and tip-tilt misalignment. Our scheme allows for
correction of these errors in closed-loop operation down to nearly zero
residuals in a few iterations. This sensor also shows low sensitivity to
misalignment of its parts and high ability for operation with a relatively
bright natural guide star. Our cophasing sensor relies on existing mask
technologies that make the concept already available for segmented apertures in
future space missions.
[37]
oai:arXiv.org:1703.05624 [pdf] - 1581967
SPHERE / ZIMPOL observations of the symbiotic system R Aqr. I. Imaging
of the stellar binary and the innermost jet clouds
Schmid, H. M.;
Bazzon, A.;
Milli, J.;
Roelfsema, R.;
Engler, N.;
Mouillet, D.;
Lagadec, E.;
Sissa, E.;
Sauvage, J. -F.;
Ginski, C.;
Baruffolo, A.;
Beuzit, J. L.;
Boccaletti, A.;
Bohn, A. J.;
Claudi, R.;
Costille, A.;
Desidera, S.;
Dohlen, K.;
Dominik, C.;
Feldt, M.;
Fusco, T.;
Gisler, D.;
Girard, J. H.;
Gratton, R.;
Henning, T.;
Hubin, N.;
Joos, F.;
Kasper, M.;
Langlois, M.;
Pavlov, A.;
Pragt, J.;
Puget, P.;
Quanz, S. P.;
Salasnich, B.;
Siebenmorgen, R.;
Stute, M.;
Suarez, M.;
Szulagyi, J.;
Thalmann, C.;
Turatto, M.;
Udry, S.;
Vigan, A.;
Wildi, F.
Submitted: 2017-03-16
R Aqr is a symbiotic binary system consisting of a mira variable, a hot
companion with a spectacular jet outflow, and an extended emission line nebula.
We have used R Aqr as test target for the visual camera subsystem ZIMPOL, which
is part of the new extreme adaptive optics (AO) instrument SPHERE at the Very
Large Telescope (VLT).
We compare our observations with data from the Hubble Space Telescope (HST)
and illustrate the complementarity of the two instruments. We determine from
the Halpha emission the position, size, geometric structure, and line fluxes of
the jet source and the clouds in the innermost region (<2") of R Aqr and
determine Halpha emissivities mean density, mass, recombination time scale, and
other cloud parameters.
Our data resolve for the first time the R Aqr binary and we measure for the
jet source a relative position 46+/-1 mas West of the mira. The central jet
source is the strongest Halpha component. North east and south west from the
central source there are many clouds with very diverse structures. We see in
the SW a string of bright clouds arranged in a zig-zag pattern and, further
out, more extended bubbles. In the N and NE we see a bright, very elongated
filamentary structure and faint perpendicular "wisps" further out. Some jet
clouds are also detected in the ZIMPOL [OI] and He I filters, as well as in the
HST line filters for Halpha, [OIII], [NII], and [OI]. We determine jet cloud
parameters and find a very well defined anti-correlation between cloud density
and distance to the central binary. Future Halpha observations will provide the
orientation of the orbital plane of the binary and allow detailed
hydrodynamical investigations of this jet outflow and its interaction with the
wind of the red giant companion.
[38]
oai:arXiv.org:1603.00481 [pdf] - 1516258
Shadows cast on the transition disk of HD 135344B. Multiwavelength
VLT/SPHERE polarimetric differential imaging
Stolker, T.;
Dominik, C.;
Avenhaus, H.;
Min, M.;
de Boer, J.;
Ginski, C.;
Schmid, H. M.;
Juhasz, A.;
Bazzon, A.;
Waters, L. B. F. M.;
Garufi, A.;
Augereau, J. -C.;
Benisty, M.;
Boccaletti, A.;
Henning, Th.;
Langlois, M.;
Maire, A. -L.;
Ménard, F.;
Meyer, M. R.;
Pinte, C.;
Quanz, S. P.;
Thalmann, C.;
Beuzit, J. -L.;
Carbillet, M.;
Costille, A.;
Dohlen, K.;
Feldt, M.;
Gisler, D.;
Mouillet, D.;
Pavlov, A.;
Perret, D.;
Petit, C.;
Pragt, J.;
Rochat, S.;
Roelfsema, R.;
Salasnich, B.;
Soenke, C.;
Wildi, F.
Submitted: 2016-03-01, last modified: 2016-11-17
The protoplanetary disk around the F-type star HD 135344B (SAO 206462) is in
a transition stage and shows many intriguing structures both in scattered light
and thermal (sub-)millimeter emission which are possibly related to planet
formation processes. We study the morphology and surface brightness of the disk
in scattered light to gain insight into the innermost disk regions, the
formation of protoplanets, planet-disk interactions traced in the surface and
midplane layers, and the dust grain properties of the disk surface. We have
carried out high-contrast polarimetric differential imaging (PDI) observations
with VLT/SPHERE and obtained polarized scattered light images with ZIMPOL in R-
and I-band and with IRDIS in Y- and J-band. The scattered light images reveal
with unprecedented angular resolution and sensitivity the spiral arms as well
as the 25 au cavity of the disk. Multiple shadow features are discovered on the
outer disk with one shadow only being present during the second observation
epoch. A positive surface brightness gradient is observed in the stellar
irradiation corrected images in southwest direction possibly due to an
azimuthally asymmetric perturbation of the temperature and/or surface density
by the passing spiral arms. The disk integrated polarized flux, normalized to
the stellar flux, shows a positive trend towards longer wavelengths which we
attribute to large aggregate dust grains in the disk surface. Part of the the
non-azimuthal polarization signal in the Uphi image of the J-band observation
could be the result of multiple scattering in the disk. The detected shadow
features and their possible variability have the potential to provide insight
into the structure of and processes occurring in the innermost disk regions.
[39]
oai:arXiv.org:1609.06681 [pdf] - 1484802
SPHERE IRDIS and IFS astrometric strategy and calibration
Maire, Anne-Lise;
Langlois, Maud;
Dohlen, Kjetil;
Lagrange, Anne-Marie;
Gratton, Raffaele;
Chauvin, Gael;
Desidera, Silvano;
Girard, Julien H.;
Milli, Julien;
Vigan, Arthur;
Zins, Gerard;
Delorme, Philippe;
Beuzit, Jean-Luc;
Claudi, Riccardo U.;
Feldt, Markus;
Mouillet, David;
Puget, Pascal;
Turatto, Massimo;
Wildi, Francois
Submitted: 2016-09-21
We present the current results of the astrometric characterization of the VLT
planet finder SPHERE over 2 years of on-sky operations. We first describe the
criteria for the selection of the astrometric fields used for calibrating the
science data: binaries, multiple systems, and stellar clusters. The analysis
includes measurements of the pixel scale and the position angle with respect to
the North for both near-infrared subsystems, the camera IRDIS and the integral
field spectrometer IFS, as well as the distortion for the IRDIS camera. The
IRDIS distortion is shown to be dominated by an anamorphism of 0.60+/-0.02%
between the horizontal and vertical directions of the detector, i.e. 6 mas at
1". The anamorphism is produced by the cylindrical mirrors in the common path
structure hence common to all three SPHERE science subsystems (IRDIS, IFS, and
ZIMPOL), except for the relative orientation of their field of view. The
current estimates of the pixel scale and North angle for IRDIS are
12.255+/-0.009 milliarcseconds/pixel for H2 coronagraphic images and
-1.75+/-0.08 deg. Analyses of the IFS data indicate a pixel scale of
7.46+/-0.02 milliarcseconds/pixel and a North angle of -102.18+/-0.13 deg. We
finally discuss plans for providing astrometric calibration to the SPHERE users
outside the instrument consortium.
[40]
oai:arXiv.org:1608.01075 [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview,
recent progress, and future perspectives
Tamura, Naoyuki;
Takato, Naruhisa;
Shimono, Atsushi;
Moritani, Yuki;
Yabe, Kiyoto;
Ishizuka, Yuki;
Ueda, Akitoshi;
Kamata, Yukiko;
Aghazarian, Hrand;
Arnouts, Stephane;
Barban, Gabriel;
Barkhouser, Robert H.;
Borges, Renato C.;
Braun, David F.;
Carr, Michael A.;
Chabaud, Pierre-Yves;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chiba, Masashi;
Chou, Richard C. Y.;
Chu, You-Hua;
Cohen, Judith G.;
de Almeida, Rodrigo P.;
de Oliveira, Antonio C.;
de Oliveira, Ligia S.;
Dekany, Richard G.;
Dohlen, Kjetil;
Santos, Jesulino B. dos;
Santos, Leandro H. dos;
Ellis, Richard S.;
Fabricius, Maximilian;
Ferrand, Didier;
Ferreira, Decio;
Golebiowski, Mirek;
Greene, Jenny E.;
Gross, Johannes;
Gunn, James E.;
Hammond, Randolph;
Harding, Albert;
Hart, Murdock;
Heckman, Timothy M.;
Hirata, Christopher M.;
Ho, Paul;
Hope, Stephen C.;
Hovland, Larry;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Ping-Jie;
Jaquet, Marc;
Jing, Yipeng;
Karr, Jennifer;
Kimura, Masahiko;
King, Matthew E.;
Komatsu, Eiichiro;
Brun, Vincent Le;
Fevre, Olivier Le;
Fur, Arnaud Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig P.;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas S.;
de Oliveira, Claudia Mendes;
Minowa, Yosuke;
Morantz, Chaz N.;
Murayama, Hitoshi;
Murray, Graham J.;
Ohyama, Youichi;
Orndorff, Joseph;
Pascal, Sandrine;
Pereira, Jefferson M.;
Reiley, Daniel J.;
Reinecke, Martin;
Ritter, Andreas;
Roberts, Mitsuko;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Sodre, Laerte;
Spergel, David N.;
Steinkraus, Aaron J.;
Strauss, Michael A.;
Surace, Christian;
Suto, Yasushi;
Suzuki, Nao;
Swinbank, John;
Tait, Philip J.;
Takada, Masahiro;
Tamura, Tomonori;
Tanaka, Yoko;
Tresse, Laurence;
Verducci, Orlando;
Vibert, Didier;
Vidal, Clement;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Yan, Chi-Hung;
Yasuda, Naoki
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the
8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed,
optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394
reconfigurable fibers will be distributed over the 1.3 deg field of view. The
spectrograph has been designed with 3 arms of blue, red, and near-infrared
cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure
at a resolution of ~1.6-2.7A. An international collaboration is developing this
instrument under the initiative of Kavli IPMU. The project is now going into
the construction phase aiming at undertaking system integration in 2017-2018
and subsequently carrying out engineering operations in 2018-2019. This article
gives an overview of the instrument, current project status and future paths
forward.
[41]
oai:arXiv.org:1608.01196 [pdf] - 1531178
Visible camera cryostat design and performance for the SuMIRe Prime
Focus Spectrograph (PFS)
Smee, Stephen A.;
Gunn, James E.;
Golebiowski, Mirek;
Hope, Stephen C.;
Madec, Fabrice;
Gabriel, Jean-Francois;
Loomis, Craig;
Fur, Arnaud Le;
Dohlen, Kjetil;
Mignant, David Le;
Barkhouser, Robert;
Carr, Michael;
Hart, Murdock;
Tamura, Naoyuki;
Shimono, Atsushi;
Takato, Naruhisa
Submitted: 2016-08-03
We describe the design and performance of the SuMIRe Prime Focus Spectrograph
(PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed
ground-based spectrograph consisting of four identical spectrograph modules,
each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the
prime focus. Each spectrograph module has three channels covering wavelength
ranges 380~nm -- 640~nm, 640~nm -- 955~nm, and 955~nm -- 1.26~um, with the
dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera.
The cameras are very large, having a clear aperture of 300~mm at the entrance
window, and a mass of $\sim$280~kg. In this paper we describe the design of the
visible camera cryostats and discuss various aspects of cryostat performance.
[42]
oai:arXiv.org:1608.01287 [pdf] - 1531180
SUBARU prime focus spectrograph: integration, testing and performance
for the first spectrograph
Madec, F.;
Fur, A. Le;
Mignant, D. Le;
Dohlen, K.;
Barrette, R.;
Belhadi, M.;
Pascal, S.;
Smee, S.;
Gunn, J.;
Merrer, J. Le;
Lorred, M.;
Jaquet, M.;
Balard, P.;
Blanchard, P.;
Thao, W.;
Roman, F.;
Lapere, V.;
Gabriel, JF;
Loomis, C.;
Golebiowski, M.;
Hart, M.;
Oliveira, L.;
Oliveira, A.;
Tamura, N.;
Shimono, A.
Submitted: 2016-08-03
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and
Redshifts (SuMIRe) project for Subaru telescope consists in four identical
spectrographs fed by 600 fibers each. Each spectrograph is composed by an
optical entrance unit that creates a collimated beam and distributes the light
to three channels, two visibles and one near infrared. This paper presents the
on-going effort for the tests & integration process for the first spectrograph
channel: we have developed a detailed Assembly Integration and Test (AIT) plan,
as well as the methods, detailed processes and I&T tools. We describe the tools
we designed to assemble the parts and to test the performance of the
spectrograph. We also report on the thermal acceptance tests we performed on
the first visible camera unit. We also report on and discuss the technical
difficulties that did appear during this integration phase. Finally, we detail
the important logistic process that is require to transport the components from
other country to Marseille.
[43]
oai:arXiv.org:1607.06606 [pdf] - 1494767
The FLARE mission: Deep and Wide-field 1-5$\mu$m Imaging and
Spectroscopy for the Early Universe: a proposal for M5 Cosmic Vision call
Submitted: 2016-07-22
FLARE (First Light And Reionization Explorer) is a space mission that will be
submitted to ESA (M5 call). Its primary goal (about 80% of lifetime) is to
identify and study galaxies that dwell in the universe before the end of the
reionization up to about z = 15, a redshift that might not be statistically
reachable for JWST, Euclid and WFIRST. A secondary objective (about 20% of
lifetime) is to survey star formation in the Milky Way.
The strategy selected for FLARE optimizes the science return: imaging and
spectroscopic integral-field observations will be carried out simultaneously on
two parallel focal planes and over very wide instantaneous fields of view.
FLARE will feature an instantaneous field of view of about 0.2 deg$^2$ with
0.2-arcsec pixels and an instantaneous integral-field spectroscopic field of
view of about 1 arcmin$^2$ with R = 500 - 1000 and an angular resolution of
about 0.4 arcsec. To detect first-light galaxies, the imaging and spectroscopic
survey (parallel observations over about 6 years) will reach m$_{AB}$ = 28 and
f$_{\lambda}$ = 10$^{-18}$ erg/cm$^2$/S.
FLARE will help addressing two of ESA's Cosmic Vision themes: a) "How did the
universe originate and what is it made of?" and b) "What are the conditions for
planet formation and the emergence of life?" and more specifically, "From gas
and dust to stars and planets".
FLARE will provide to the ESA community a leading position to statistically
study the early universe after JWST's deep but pin-hole surveys. Moreover, the
instrumental development of wide-field imaging and wide-field integral-field
spectroscopy in space will be a major breakthrough after making them available
on ground-based telescopes.
[44]
oai:arXiv.org:1606.01895 [pdf] - 1447792
Calibration of quasi-static aberrations in exoplanet direct-imaging
instruments with a Zernike phase-mask sensor. II. Concept validation with
ZELDA on VLT/SPHERE
N'Diaye, M.;
Vigan, A.;
Dohlen, K.;
Sauvage, J. -F.;
Caillat, A.;
Costille, A.;
Girard, J. H. V.;
Beuzit, J. -L.;
Fusco, T.;
Blanchard, P.;
Merrer, J. Le;
Mignant, D. Le;
Madec, F.;
Moreaux, G.;
Mouillet, D.;
Puget, P.;
Zins, G.
Submitted: 2016-06-06, last modified: 2016-06-17
Warm or massive gas giant planets, brown dwarfs, and debris disks around
nearby stars are now routinely observed by dedicated high-contrast imaging
instruments on large, ground-based observatories. These facilities include
extreme adaptive optics (ExAO) and state-of-the-art coronagraphy to achieve
unprecedented sensitivities for exoplanet detection and spectral
characterization. However, differential aberrations between the ExAO sensing
path and the science path represent a critical limitation for the detection of
giant planets with a contrast lower than a few $10^{-6}$ at very small
separations (<0.3\as) from their host star. In our previous work, we proposed a
wavefront sensor based on Zernike phase contrast methods to circumvent this
issue and measure these quasi-static aberrations at a nanometric level. We
present the design, manufacturing and testing of ZELDA, a prototype that was
installed on VLT/SPHERE during its reintegration in Chile. Using the internal
light source of the instrument, we performed measurements in the presence of
Zernike or Fourier modes introduced with the deformable mirror. Our
experimental and simulation results are consistent, confirming the ability of
our sensor to measure small aberrations (<50 nm rms) with nanometric accuracy.
We then corrected the long-lived non-common path aberrations in SPHERE based on
ZELDA measurements. We estimated a contrast gain of 10 in the coronagraphic
image at 0.2\as, reaching the raw contrast limit set by the coronagraph in the
instrument. The simplicity of the design and its phase reconstruction algorithm
makes ZELDA an excellent candidate for the on-line measurements of quasi-static
aberrations during the observations. The implementation of a ZELDA-based
sensing path on the current and future facilities (ELTs, future space missions)
could ease the observation of the cold gaseous or massive rocky planets around
nearby stars.
[45]
oai:arXiv.org:1605.08523 [pdf] - 1451912
Laboratory validation of the dual-zone phase mask coronagraph in
broadband light at the high-contrast imaging THD-testbed
Submitted: 2016-05-27
Specific high contrast imaging instruments are mandatory to characterize
circumstellar disks and exoplanets around nearby stars. Coronagraphs are
commonly used in these facilities to reject the diffracted light of an observed
star and enable the direct imaging and spectroscopy of its circumstellar
environment. One important property of the coronagraph is to be able to work in
broadband light.
Among several proposed coronagraphs, the dual-zone phase mask coronagraph is
a promising solution for starlight rejection in broadband light. In this paper,
we perform the first validation of this concept in laboratory.
First, we recall the principle of the dual-zone phase mask coronagraph. Then,
we describe the high-contrast imaging THD testbed, the manufacturing of the
components and the quality-control procedures. Finally, we study the
sensitivity of our coronagraph to low-order aberrations (inner working angle
and defocus) and estimate its contrast performance. Our experimental broadband
light results are compared with numerical simulations to check agreement with
the performance predictions.
With the manufactured prototype and using a dark hole technique based on the
self-coherent camera, we obtain contrast levels down to $2\,10^{-8}$ between 5
and 17$\,\lambda_0/D$ in monochromatic light (640 nm). We also reach contrast
levels of $4\,10^{-8}$ between 7 and 17$\lambda_0/D$ in broadband
($\lambda_0=675$ nm, $\Delta\lambda=250$ nm and $\Delta\lambda / \lambda_0 =
40$ %), which demonstrates the excellent chromatic performance of the dual-zone
phase mask coronagraph.
The performance reached by the dual-zone phase mask coronagraph is promising
for future high-contrast imaging instruments that aim at detecting and
spectrally characterizing old or light gaseous planets.
[46]
oai:arXiv.org:1603.00457 [pdf] - 1379003
VLT/SPHERE deep insight of NGC 3603's core: Segregation or confusion?
Khorrami, Z.;
Lanz, T.;
Vakili, F.;
Lagadec, E.;
Langlois, M.;
Brandner, W.;
Chesneau, O.;
Meyer, M. R.;
Carbillet, M.;
Abe, L.;
Mouillet, D.;
Beuzit, JL.;
Boccaletti, A.;
Perrot, C.;
Thalmann, C.;
Schmid, H. -M.;
Pavlov, A.;
Costille, A.;
Dohlen, K.;
Mignant, D. Le;
Petit, C.;
Sauvage, J. F.
Submitted: 2016-03-01
We present new near-infrared photometric measurements of the core of the
young massive cluster NGC 3603 obtained with extreme adaptive optics. The data
were obtained with the SPHERE instrument mounted on ESO Very Large Telescope,
and cover three fields in the core of this cluster. We applied a correction for
the effect of extinction to our data obtained in the J and K broadband filters
and estimated the mass of detected sources inside the field of view of
SPHERE/IRDIS, which is 13.5"x13.5". We derived the mass function (MF) slope for
each spectral band and field. The MF slope in the core is unusual compared to
previous results based on Hubble space telescope (HST) and very large telescope
(VLT) observations. The average slope in the core is estimated as
-1.06^{+0.26}_{-0.26} for the main sequence stars with 3.5 Msun < M < 120
Msun.Thanks to the SPHERE extreme adaptive optics, 814 low-mass stars were
detected to estimate the MF slope for the pre-main sequence stars with 0.6
Msun< M < 3.5 Msun , Gamma = -0.54^{+0.11}_{-0.11} in the K-band images in two
fields in the core of the cluster. For the first time, we derive the mass
function of the very core of the NGC 3603 young cluster for masses in the range
0.6 - 120 Msun. Previous studies were either limited by crowding, lack of
dynamic range, or a combination of both.
[47]
oai:arXiv.org:1512.05378 [pdf] - 1354861
Apodization in high-contrast long-slit spectroscopy. II. Concept
validation and first on-sky results with VLT/SPHERE
Vigan, A.;
N'Diaye, M.;
Dohlen, K.;
Beuzit, J. -L.;
Costille, A.;
Caillat, A.;
Baruffolo, A.;
Blanchard, P.;
Carle, M.;
Ferrari, M.;
Fusco, T.;
Gluck, L.;
Hugot, E.;
Jaquet, M.;
Langlois, M.;
Mignant, D. Le;
Llored, M.;
Madec, F.;
Mouillet, D.;
Origné, A.;
Puget, P.;
Salasnich, B.;
Sauvage, J. -F.
Submitted: 2015-12-16
Spectral characterization of young, giant exoplanets detected by direct
imaging is one of the tasks of the new generation of high-contrast imagers. For
this purpose, the VLT/SPHERE instrument includes a unique long-slit
spectroscopy (LSS) mode coupled with Lyot coronagraphy in its infrared
dual-band imager and spectrograph (IRDIS). The performance of this mode is
intrinsically limited by the use of a non-optimal coronagraph, but in a
previous work we demonstrated that it could be significantly improved at small
inner-working angles using the stop-less Lyot coronagraph (SLLC). We now
present the development, testing, and validation of the first SLLC prototype
for VLT/SPHERE. Based on the transmission profile previously proposed, the
prototype was manufactured using microdots technology and was installed inside
the instrument in 2014. The transmission measurements agree well with the
specifications, except in the very low transmissions (<5% in amplitude). The
performance of the SLLC is tested in both imaging and spectroscopy using data
acquired on the internal source. In imaging, we obtain a raw contrast gain of a
factor 10 at 0.3" and 5 at 0.5" with the SLLC. Using data acquired with a
focal-plane mask, we also demonstrate that no Lyot stop is required to reach
the full performance, which validates the SLLC concept. Comparison with a
realistic simulation model shows that we are currently limited by the internal
phase aberrations of SPHERE. In spectroscopy, we obtain a gain of ~1 mag in a
limited range of angular separations. Simulations show that although the main
limitation comes from phase errors, the performance in the non-SLLC case is
very close to the ultimate limit of the LSS mode. Finally, we obtain the very
first on-sky data with the SLLC, which appear extremely promising for the
future scientific exploitation of an apodized LSS mode in SPHERE.
[48]
oai:arXiv.org:1511.04072 [pdf] - 1362622
First light of the VLT planet finder SPHERE. II. The physical properties
and the architecture of the young systems PZ Tel and HD 1160 revisited
Maire, A. -L.;
Bonnefoy, M.;
Ginski, C.;
Vigan, A.;
Messina, S.;
Mesa, D.;
Galicher, R.;
Gratton, R.;
Desidera, S.;
Kopytova, T. G.;
Millward, M.;
Thalmann, C.;
Claudi, R. U.;
Ehrenreich, D.;
Zurlo, A.;
Chauvin, G.;
Antichi, J.;
Baruffolo, A.;
Bazzon, A.;
Beuzit, J. -L.;
Blanchard, P.;
Boccaletti, A.;
de Boer, J.;
Carle, M.;
Cascone, E.;
Costille, A.;
De Caprio, V.;
Delboulbe, A.;
Dohlen, K.;
Dominik, C.;
Feldt, M.;
Fusco, T.;
Girard, J. H.;
Giro, E.;
Gisler, D.;
Gluck, L.;
Gry, C.;
Henning, T.;
Hubin, N.;
Hugot, E.;
Jaquet, M.;
Kasper, M.;
Lagrange, A. -M.;
Langlois, M.;
Mignant, D. Le;
Llored, M.;
Madec, F.;
Martinez, P.;
Mawet, D.;
Milli, J.;
Moeller-Nilsson, O.;
Mouillet, D.;
Moulin, T.;
Moutou, C.;
Origne, A.;
Pavlov, A.;
Petit, C.;
Pragt, J.;
Puget, P.;
Ramos, J.;
Rochat, S.;
Roelfsema, R.;
Salasnich, B.;
Sauvage, J. -F.;
Schmid, H. M.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Wahhaj, Z.;
Weber, L.;
Wildi, F.
Submitted: 2015-11-12, last modified: 2015-11-13
[Abridged] Context. The young systems PZ Tel and HD 1160, hosting known
low-mass companions, were observed during the commissioning of the new planet
finder SPHERE with several imaging and spectroscopic modes. Aims. We aim to
refine the physical properties and architecture of both systems. Methods. We
use SPHERE commissioning data and REM observations, as well as literature and
unpublished data from VLT/SINFONI, VLT/NaCo, Gemini/NICI, and Keck/NIRC2.
Results. We derive new photometry and confirm the nearly daily photometric
variability of PZ Tel A. Using literature data spanning 38 yr, we show that the
star also exhibits a long-term variability trend. The 0.63-3.8 mic SED of PZ
Tel B allows us to revise its properties: spectral type M7+/-1, Teff=2700+/-100
K, log(g)<4.5 dex, log(L/L_Sun)=-2.51+/-0.10 dex, and mass 38-72 MJ. The 1-3.8
mic SED of HD 1160 B suggests a massive brown dwarf or a low-mass star with
spectral type M5.5-7.0, Teff=3000+/-100 K, [M/H]=-0.5-0.0 dex,
log(L/L_Sun)=-2.81+/-0.10 dex, and mass 39-168 MJ. We confirm the deceleration
and high eccentricity (e>0.66) of PZ Tel B. For e<0.9, the inclination,
longitude of the ascending node, and time of periastron passage are well
constrained. The system is seen close to an edge-on geometry. We reject other
brown dwarf candidates outside 0.25" for both systems, and massive giant
planets (>4 MJ) outside 0.5" for the PZ Tel system. We also show that K1-K2
color can be used with YJH low-resolution spectra to identify young L-type
companions, provided high photometric accuracy (<0.05 mag) is achieved.
Conclusions. SPHERE opens new horizons in the study of young brown dwarfs and
giant exoplanets thanks to high-contrast imaging capabilities at optical and
near-infrared wavelengths, as well as high signal-to-noise spectroscopy in the
near-infrared from low (R~30-50) to medium resolutions (R~350).
[49]
oai:arXiv.org:1511.04083 [pdf] - 1362624
First light of the VLT planet finder SPHERE. III. New spectrophotometry
and astrometry of the HR8799 exoplanetary system
Zurlo, A.;
Vigan, A.;
Galicher, R.;
Maire, A. -L.;
Mesa, D.;
Gratton, R.;
Chauvin, G.;
Kasper, M.;
Moutou, C.;
Bonnefoy, M.;
Desidera, S.;
Abe, L.;
Apai, D.;
Baruffolo, A.;
Baudoz, P.;
Baudrand, J.;
Beuzit, J. -L.;
Blancard, P.;
Boccaletti, A.;
Cantalloube, F.;
Carle, M.;
Charton, J.;
Claudi, R. U.;
Costille, A.;
de Caprio, V.;
Dohlen, K.;
Dominik, C.;
Fantinel, D.;
Feautrier, P.;
Feldt, M.;
Fusco, T.;
Gascone, E.;
Gigan, P.;
Girard, J. H.;
Gissler, D.;
Gluck, L.;
Gry, C.;
Henning, T.;
Hugot, E.;
Janson, M.;
Jacquet, M.;
Lagrange, A. -M.;
Langlois, M.;
Llored, M.;
Made, F.;
Magnard, Y.;
Martinez, P.;
Maurel, D.;
Mawet, D.;
Meyer, M. R.;
Milli, J.;
Moeller-Nilsson, O.;
Mouillet, D.;
Origné, A.;
Pavlov, A.;
Petit, C.;
Puget, P.;
Quanz, S. P.;
Rabou, P.;
Ramos, J.;
Roux, A.;
Salasnich, B.;
Salter, G.;
Sauvage, J. -F.;
Schmid, H. M.;
Soenke, C.;
Stadler, E.;
Suarez, M.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Wahhaj, Z.;
Wildi, F.
Submitted: 2015-11-12
The planetary system discovered around the young A-type HR8799 provides a
unique laboratory to: a) test planet formation theories, b) probe the diversity
of system architectures at these separations, and c) perform comparative
(exo)planetology. We present and exploit new near-infrared images and
integral-field spectra of the four gas giants surrounding HR8799 obtained with
SPHERE, the new planet finder instrument at the Very Large Telescope, during
the commissioning and science verification phase of the instrument
(July-December 2014). With these new data, we contribute to completing the
spectral energy distribution of these bodies in the 1.0-2.5 $\mu$m range. We
also provide new astrometric data, in particular for planet e, to further
constrain the orbits. We used the infrared dual-band imager and spectrograph
(IRDIS) subsystem to obtain pupil-stabilized, dual-band $H2H3$ (1.593 $\mu$m,
1.667 $\mu$m), $K1K2$ (2.110 $\mu$m, 2.251 $\mu$m), and broadband $J$ (1.245
$\mu$m) images of the four planets. IRDIS was operated in parallel with the
integral field spectrograph (IFS) of SPHERE to collect low-resolution
($R\sim30$), near-infrared (0.94-1.64 $\mu$m) spectra of the two innermost
planets HR8799d and e. The data were reduced with dedicated algorithms, such as
the Karhunen-Lo\`eve image projection (KLIP), to reveal the planets. We used
the so-called negative planets injection technique to extract their photometry,
spectra, and measure their positions. We illustrate the astrometric performance
of SPHERE through sample orbital fits compatible with SPHERE and literature
data.
[50]
oai:arXiv.org:1511.04076 [pdf] - 1358963
First light of the VLT planet finder SPHERE. I. Detection and
characterization of the sub-stellar companion GJ 758 B
Vigan, A.;
Bonnefoy, M.;
Ginski, C.;
Beust, H.;
Galicher, R.;
Janson, M.;
Baudino, J. -L.;
Buenzli, E.;
Hagelberg, J.;
D'Orazi, V.;
Desidera, S.;
Maire, A. -L.;
Gratton, R.;
Sauvage, J. -F.;
Chauvin, G.;
Thalmann, C.;
Malo, L.;
Salter, G.;
Zurlo, A.;
Antichi, J.;
Baruffolo, A.;
Baudoz, P.;
Blanchard, P.;
Boccaletti, A.;
Beuzit, J. -L.;
Carle, M.;
Claudi, R.;
Costille, A.;
Delboulbé, A.;
Dohlen, K.;
Dominik, C.;
Feldt, M.;
Fusco, T.;
Gluck, L.;
Girard, J.;
Giro, E.;
Gry, C.;
Henning, T.;
Hubin, N.;
Hugot, E.;
Jacquet, M.;
Kasper, M.;
Lagrange, A. -M.;
Langlois, M.;
Mignant, D. Le;
Llored, M.;
Madec, F.;
Martinez, P.;
Mawet, D.;
Mesa, D.;
Milli, J.;
Mouillet, D.;
Moulin, T.;
Moutou, C.;
Origné, A.;
Pavlov, A.;
Perret, D.;
Petit, C.;
Pragt, J.;
Puget, P.;
Rabou, P.;
Rochat, S.;
Roelfsema, R.;
Salasnich, B.;
Schmid, H. -M.;
Sevin, A.;
Smette, A.;
Stadler, E.;
Suarez, M.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Wahhaj, Z.;
Weber, L.;
Wildi, F.
Submitted: 2015-11-12
GJ758 B is a brown dwarf companion to a nearby (15.76 pc) solar-type,
metal-rich (M/H = +0.2 dex) main-sequence star (G9V) that was discovered with
Subaru/HiCIAO in 2009. From previous studies, it has drawn attention as being
the coldest (~600K) companion ever directly imaged around a neighboring star.
We present new high-contrast data obtained during the commissioning of the
SPHERE instrument at the VLT. The data was obtained in Y-, J-, H-, and Ks-bands
with the dual-band imaging (DBI) mode of IRDIS, providing a broad coverage of
the full near-infrared (near-IR) range at higher contrast and better spectral
sampling than previously reported. In this new set of high-quality data, we
report the re-detection of the companion, as well as the first detection of a
new candidate closer-in to the star. We use the new 8 photometric points for an
extended comparison of GJ758 B with empirical objects and 4 families of
atmospheric models. From comparison to empirical object, we estimate a T8
spectral type, but none of the comparison object can accurately represent the
observed near-IR fluxes of GJ758 B. From comparison to atmospheric models, we
attribute a Teff = 600K $\pm$ 100K, but we find that no atmospheric model can
adequately fit all the fluxes of GJ758 B. The photometry of the new candidate
companion is broadly consistent with L-type objects, but a second epoch with
improved photometry is necessary to clarify its status. The new astrometry of
GJ758 B shows a significant proper motion since the last epoch. We use this
result to improve the determination of the orbital characteristics using two
fitting approaches, Least-Square Monte Carlo and Markov Chain Monte Carlo.
Finally, we analyze the sensitivity of our data to additional closer-in
companions and reject the possibility of other massive brown dwarf companions
down to 4-5 AU. [abridged]
[51]
oai:arXiv.org:1511.04082 [pdf] - 1358964
First light of the VLT planet finder SPHERE. IV. Physical and chemical
properties of the planets around HR8799
Bonnefoy, M.;
Zurlo, A.;
Baudino, J. L.;
Lucas, P.;
Mesa, D.;
Maire, A. -L.;
Vigan, A.;
Galicher, R.;
Homeier, D.;
Marocco, F.;
Gratton, R.;
Chauvin, G.;
Allard, F.;
Desidera, S.;
Kasper, M.;
Moutou, C.;
Lagrange, A. -M.;
Baruffolo, A.;
Baudrand, J.;
Beuzit, J. -L.;
Boccaletti, A.;
Cantalloube, F.;
Carbillet, M.;
Charton, J.;
Claudi, R. U.;
Costille, A.;
Dohlen, K.;
Dominik, C.;
Fantinel, D.;
Feautrier, P.;
Feldt, M.;
Fusco, T.;
Gigan, P.;
Girard, J. H.;
Gluck, L.;
Gry, C.;
Henning, T.;
Janson, M.;
Langlois, M.;
Madec, F.;
Magnard, Y.;
Maurel, D.;
Mawet, D.;
Meyer, M. R.;
Milli, J.;
Moeller-Nilsson, O.;
Mouillet, D.;
Pavlov, A.;
Perret, D.;
Pujet, P.;
Quanz, S. P.;
Rochat, S.;
Rousset, G.;
Roux, A.;
Salasnich, B.;
Salter, G.;
Sauvage, J. -F.;
Schmid, H. M.;
Sevin, A.;
Soenke, C.;
Stadler, E.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Wahhaj, Z.;
Wildi, F.
Submitted: 2015-11-12
The system of four planets around HR8799 offers a unique opportunity to probe
the physics and chemistry at play in the atmospheres of self-luminous young
(~30 Myr) planets. We recently obtained new photometry of the four planets and
low-resolution (R~30) spectra of HR8799 d and e with the SPHERE instrument
(paper III). In this paper (paper IV), we compare the available spectra and
photometry of the planets to known objects and atmospheric models (BT-SETTL14,
Cloud-AE60, Exo-REM) to characterize the atmospheric properties of the planets.
We find that HR8799d and e properties are well reproduced by those of L6-L8
dusty dwarfs discovered in the field, among which some are candidate members of
young nearby associations. No known object reproduces well the properties of
planets b and c. Nevertheless, we find that the spectra and WISE photometry of
peculiar and/or young early-T dwarfs reddened by submicron grains made of
corundum, iron, enstatite, or forsterite successfully reproduce the SED of
these two planets. Our analysis confirms that only the Exo-REM models with
thick clouds fit (within 2{\sigma}) the whole set of spectrophotometric
datapoints available for HR8799 d and e for Teff = 1200 K, log g in the range
3.0-4.5, and M/H=+0.5. The models still fail to reproduce the SED of HR8799c
and b. The determination of the metallicity, log g, and cloud thickness are
degenerate. We conclude that an enhanced content in dust and decreased CIA of
H2 is certainly responsible for the deviation of the properties of the planet
with respect to field dwarfs. The analysis suggests in addition that HR8799c
and b have later spectral types than the two other planets, and therefore could
both have lower masses.
[52]
oai:arXiv.org:1510.06331 [pdf] - 1297783
K-Stacker, a new way of detecting and characterizing exoplanets with
high contrast imaging instruments
Submitted: 2015-10-21
This year, a second generation of coronagraphs dedicated to high-contrast
direct imaging of exoplanets is starting operations. Among them, SPHERE,
installed at the focus of the UT3 Very Large Telescope, reaches unprecedented
contrast ratios up to $10^{-6}$ -$ 10^{-7}$, using eXtreme Adaptive Optics and
the Angular Differential Imaging (ADI) techniques.
In this paper, we present a new method called Keplerian-Stacker that improves
the detection limit of high contrast instruments like SPHERE, by up to a factor
of 10. It consists of observing a star on a long enough period to let a
hypothetical planet around that star move along its orbit. Even if in each
individual observation taken during one night, we do not detect anything, we
show that it is possible, using an optimization algorithm, to re-center the
images according to keplerian motions (ex: 10-100 images taken over a long
period of typically 1-10 years) and detect planets otherwise unreachable. This
method can be used in combination with the ADI technics (or possibly any other
high contrast data reduction method) to improve the Signal to Noise Ratio in
each individual image, and to further improve the global detection limit. It
also directly provides orbital parameters of the detected planets, as a
by-product of the optimization algorithm.
[53]
oai:arXiv.org:1509.02725 [pdf] - 1274617
THERMAP: a mid-infrared spectro-imager for space missions to small
bodies in the inner solar system
Groussin, O.;
Licandro, J.;
Helbert, J.;
Reynaud, J. -L.;
Levacher, P.;
García-Talavera, M. Reyes;
Alí-Lagoa, V.;
Blanc, P. -E.;
Brageot, E.;
Davidsson, B.;
Delbó, M.;
Deleuze, M.;
Delsanti, A.;
Garcia, J. J. Diaz;
Dohlen, K.;
Ferrand, D.;
Green, S.;
Jorda, L.;
Álvarez, E. Joven;
Knollenberg, J.;
Kührt, E.;
Lamy, P.;
Lellouch, E.;
Merrer, J. Le;
Marty, B.;
Mas, G.;
Rossin, C.;
Rozitis, B.;
Sunshine, J.;
Vernazza, P.;
Vives, S.
Submitted: 2015-09-09
We present THERMAP, a mid-infrared (8-16 {\mu}m) spectro-imager for space
missions to small bodies in the inner solar system, developed in the framework
of the MarcoPolo-R asteroid sample return mission. THERMAP is very well suited
to characterize the surface thermal environment of a NEO and to map its surface
composition. The instrument has two channels, one for imaging and one for
spectroscopy: it is both a thermal camera with full 2D imaging capabilities and
a slit spectrometer. THERMAP takes advantage of the recent technological
developments of uncooled microbolometers detectors, sensitive in the
mid-infrared spectral range. THERMAP can acquire thermal images (8-18 {\mu}m)
of the surface and perform absolute temperature measurements with a precision
better than 3.5 K above 200 K. THERMAP can acquire mid-infrared spectra (8-16
{\mu}m) of the surface with a spectral resolution {\Delta}{\lambda} of 0.3
{\mu}m. For surface temperatures above 350 K, spectra have a signal-to-noise
ratio >60 in the spectral range 9-13 {\mu}m where most emission features occur.
[54]
oai:arXiv.org:1503.02486 [pdf] - 1231979
Performance of the VLT Planet Finder SPHERE II. Data analysis and
Results for IFS in laboratory
Mesa, D.;
Gratton, R.;
Zurlo, A.;
Vigan, A.;
Claudi, R. U.;
Alberi, M.;
Antichi, J.;
Baruffolo, A.;
Beuzit, J. -L.;
Boccaletti, A.;
Bonnefoy, M.;
Costille, A.;
Desidera, S.;
Dohlen, K.;
Fantinel, D.;
Feldt, M.;
Fusco, T.;
Giro, E.;
Henning, T.;
Kasper, M.;
Langlois, M.;
Maire, A. -L.;
Martinez, P.;
Moeller-Nilsson, O.;
Mouillet, D.;
Moutou, C.;
Pavlov, A.;
Puget, P.;
Salasnich, B.;
Sauvage, J. -F.;
Sissa, E.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Waters, R.;
Wildi, F.
Submitted: 2015-03-09
We present the performance of the Integral Field Spectrograph (IFS) of
SPHERE, the high-contrast imager for the ESO VLT telescope designed to perform
imaging and spectroscopy of extrasolar planets, obtained from tests performed
at the Institute de Plan\'etologie et d'Astrophysique de Grenoble facility
during the integration phase of the instrument.} {The tests were performed
using the instrument software purposely prepared for SPHERE. The output data
were reduced applying the SPHERE data reduction and handling software, adding
an improved spectral deconvolution procedure. To this aim, we prepared an
alternative procedure for the spectral subtraction exploiting the principal
components analysis algorithm. Moreover, a simulated angular differential
imaging procedure was also implemented to estimate how the instrument performed
once this procedure was applied at telescope. The capability of the IFS to
faithfully retrieve the spectra of the detected faint companions was also
considered.} {We found that the application of the updated version of the
spectral deconvolution procedure alone, when the algorithm throughput is
properly taken into account, gives us a $5\sigma$ limiting contrast of the
order of 5$\times$$10^{-6}$ or slightly better. The further application of the
angular differential imaging procedure on these data should allow us to improve
the contrast by one order of magnitude down to around 7$\times$$10^{-7}$ at a
separation of 0.3 arcsec. The application of a principal components analysis
procedure that simultaneously uses spectral and angular data gives comparable
results. Finally, we found that the reproducibility of the spectra of the
detected faint companions is greatly improved when angular differential imaging
is applied in addition to the spectral deconvolution.
[55]
oai:arXiv.org:1410.1754 [pdf] - 903834
Performance of the VLT Planet Finder SPHERE I. Photometry and astrometry
precision with IRDIS and IFS in laboratory
Zurlo, A.;
Vigan, A.;
Mesa, D.;
Gratton, R.;
Moutou, C.;
Langlois, M.;
Claudi, R. U.;
Pueyo, L.;
Boccaletti, A.;
Baruffolo, A.;
Beuzit, J. -L.;
Costille, A.;
Desidera, S.;
Dohlen, K.;
Feldt, M.;
Fusco, T.;
Henning, T.;
Kasper, M.;
Martinez, P.;
Moeller-Nilsson, O.;
Mouillet, D.;
Pavlov, A.;
Puget, P.;
Sauvage, J. -F.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Waters, R.;
Wildi, R. F.
Submitted: 2014-10-07
The new planet finder for the Very Large Telescope (VLT), the
Spectro-Polarimetric High-contrast Exoplanet REsearch (SPHERE), just had its
first light in Paranal. A dedicated instrument for the direct detection of
planets, SPHERE, is composed of a polametric camera in visible light, the
Zurich IMager POLarimeter (ZIMPOL), and two near-infrared sub-systems: the
Infra-Red Dual-beam Imager and Spectrograph (IRDIS), a multi-purpose camera for
imaging, polarimetry, and long-slit spectroscopy, and the integral field
spectrograph (IFS), an integral field spectrograph. We present the results
obtained from the analysis of data taken during the laboratory integration and
validation phase, after the injection of synthetic planets. Since no continuous
field rotation could be performed in the laboratory, this analysis presents
results obtained using reduction techniques that do not use the angular
differential imaging (ADI) technique. To perform the simulations, we used the
instrumental point spread function (PSF) and model spectra of L and T-type
objects scaled in contrast with respect to the host star. We evaluated the
expected error in astrometry and photometry as a function of the signal to
noise of companions, after spectral differential imaging (SDI) reduction for
IRDIS and spectral deconvolution (SD) or principal component analysis (PCA)
data reductions for IFS. We deduced from our analysis, for example, that
$\beta$Picb, a 12~Myr old planet of $\sim$10~\MJ and semi-major axis of 9--10
AU, would be detected with IRDIS with a photometric error of 0.16~mag and with
a relative astrometric position error of 1.1~mas. With IFS, we could retrieve a
spectrum with error bars of about 0.15~mag on each channel and astrometric
relative position error of 0.6~mas. For a fainter object such as HR8799d, a
13~\MJ planet at a distance of 27~AU, IRDIS could obtain a relative astrometric
error of 3~mas.
[56]
oai:arXiv.org:1409.2247 [pdf] - 1216772
Compensation of high-order quasi-static aberrations on SPHERE with the
coronagraphic phase diversity (COFFEE)
Submitted: 2014-09-08
The second-generation instrument SPHERE, dedicated to high-contrast imaging,
will soon be in operation on the European Very Large Telescope. Such an
instrument relies on an extreme adaptive optics system coupled with a
coronagraph that suppresses most of the diffracted stellar light. However, the
coronagraph performance is strongly limited by quasi-static aberrations that
create long-lived speckles in the scientific image plane, which can easily be
mistaken for planets. The ultimate performance is thus limited by the
unavoidable differential aberrations between the wave-front sensor and the
scientific camera, which have to be estimated andcompensated for. In this
paper, we use the COFFEE approach to measure and compensate for SPHERE's
quasi-static aberrations. COFFEE (for COronagraphic Focal-plane wave-Front
Estimation for Exoplanet detection), which consists in an extension of phase
diversity to coronagraphic imaging, estimates the quasi-static aberrations,
including the differential ones, using only two focal plane images recorded by
the scientific camera. In this paper, we use coronagraphic images recorded from
SPHERE's infrared detector IRDIS to estimate the aberrations upstream of the
coronagraph, which are then compensated for using SPHERE's extreme adaptive
optics loop SAXO. We first validate the ability of COFFEE to estimate
high-order aberrations by estimating a calibrated influence function pattern
introduced upstream of the coronagraph. We then use COFFEE in an original
iterative compensation process to compensate for the estimated aberrations,
leading to a contrast improvement by a factor that varies from 1.4 to 4.7
between 2l/D and 15l/D on IRDIS. The performance of the compensation process is
also evaluated through simulations. An excellent match between experimental
results and these simulations is found.
[57]
oai:arXiv.org:1310.5459 [pdf] - 1180090
High-order myopic coronagraphic phase diversity (COFFEE) for wave-front
control in high-contrast imaging systems
Submitted: 2013-10-21
The estimation and compensation of quasi-static aberrations is mandatory to
reach the ultimate performance of high-contrast imaging systems. COFFEE is a
focal plane wave-front sensing method that consists in the extension of phase
diversity to high-contrast imaging systems. Based on a Bayesian approach, it
estimates the quasi-static aberrations from two focal plane images recorded
from the scientific camera itself. In this paper, we present COFFEE's extension
which allows an estimation of low and high order aberrations with nanometric
precision for any coronagraphic device. The performance is evaluated by
realistic simulations, performed in the SPHERE instrument framework. We develop
a myopic estimation that allows us to take into account an imperfect knowledge
on the used diversity phase. Lastly, we evaluate COFFEE's performance in a
compensation process, to optimize the contrast on the detector, and show it
allows one to reach the 10^-6 contrast required by SPHERE at a few resolution
elements from the star. Notably, we present a non-linear energy minimization
method which can be used to reach very high contrast levels (better than 10^-7
in a SPHERE-like context)
[58]
oai:arXiv.org:1307.4240 [pdf] - 1172763
Performances tests on the SPHERE-IFS
Mesa, Dino;
Gratton, Raffaele;
Claudi, Riccardo U.;
Desidera, Silvano;
Giro, Enrico;
Zurlo, Alice;
Costille, Anne;
Vigan, Arthur;
Moutou, Claire;
Beuzit, Jean-Luc;
Dohlen, Kjetil;
Feldt, Markus;
Mouillet, David;
Sauvage, Jean-Francois;
Kasper, Markus;
Antichi, Jacopo
Submitted: 2013-07-16, last modified: 2013-07-24
Until now, just a few extrasolar planets (~30 out of 860) have been found
through the direct imaging method. This number should greatly improve when the
next generation of High Contrast Instruments like Gemini Planet Imager (GPI) at
Gemini South Telescope or SPHERE at VLT will became operative at the end of
this year. In particular, the Integral Field Spectrograph (IFS), one of the
SPHERE subsystems, should allow a first characterization of the spectral type
of the found extrasolar planets. Here we present the results of the last
performance tests that we have done on the IFS instrument at the Institut de
Planetologie et d'Astrophysique de Grenoble (IPAG) in condition as similar as
possible to the ones that we will find at the telescope. We have found that we
should be able to reach contrast down to 5x10$^{-7}$ and make astrometry at
sub-mas level with the instrument in the actual conditions. A number of
critical issues have been identified. The resolution of these problems could
allow to further improve the performance of the instrument.
[59]
oai:arXiv.org:1305.5142 [pdf] - 691674
Apodization in high-contrast long-slit spectroscopy. Closer, deeper,
fainter, cooler
Submitted: 2013-05-22, last modified: 2013-07-11
The spectroscopy of faint planetary-mass companions to nearby stars is one of
the main challenges that new-generation high-contrast spectro-imagers are going
to face. In a previous work we presented a long slit coronagraph (LSC), for
which the presence of a slit in the coronagraphic focal plane induces a complex
distribution of energy in the Lyot pupil-plane that cannot be easily masked
with a binary Lyot stop. To alleviate this concern, we propose to use a pupil
apodization to suppress diffraction, creating an apodized long slit coronagraph
(ALSC). After describing how the apodization is optimized, we demonstrate its
advantages with respect to the CLC in the context of SPHERE/IRDIS long slit
spectroscopy (LSS) mode at low-resolution with a 0.12" slit and 0.18"
coronagraphic mask. We perform different sets of simulations with and without
aberrations, and with and without a slit to demonstrate that the apodization is
a more appropriate concept for LSS, at the expense of a significantly reduced
throughput (37%) compared to the LSC. Then we perform detailed end-to-end
simulations of the LSC and the ALSC that include realistic levels of
aberrations to obtain datasets representing 1h of integration time on stars of
spectral types A0 to M0 located at 10 pc. We insert spectra of planetary
companions at different effective temperatures (Teff) and surface gravities
(log g) into the data at angular separations of 0.3" to 1.5" and with contrast
ratios from 6 to 18 mag. Using the SD method to subtract the speckles, we show
that the ALSC brings a gain in sensitivity of up to 3 mag at 0.3" with respect
to the LSC, which leads to a much better spectral extraction below 0.5". In
terms of Teff, we demonstrate that at small angular separations the limit with
the ALSC is always lower by at least 100K, inducing an increase of sensitivity
of a factor up to 1.8 in objects' masses at young ages. [Abridged]
[60]
oai:arXiv.org:1306.1006 [pdf] - 1171814
Prospects of detecting the polarimetric signature of the Earth-mass
planet alpha Centauri B b with SPHERE / ZIMPOL
Submitted: 2013-06-05, last modified: 2013-06-22
Over the past five years, radial-velocity and transit techniques have
revealed a new population of Earth-like planets with masses of a few Earth
masses. Their very close orbit around their host star requires an exquisite
inner working angle to be detected in direct imaging and sets a challenge for
direct imagers that work in the visible range, like SPHERE / ZIMPOL. Among all
known exoplanets with less than twenty-five Earth-masses we first predict the
best candidate for direct imaging. Our primary objective is then to provide the
best instrument setup and observing strategy for detecting such a peculiar
object with ZIMPOL. As a second step, we aim at predicting its detectivity.
Using exoplanet properties constrained by radial velocity measurements,
polarimetric models and the diffraction propagation code CAOS, we estimate the
detection sensitivity of ZIMPOL for such a planet in different observing modes
of the instrument. We show how observing strategies can be optimized to yield
the best detection performance on a specific target. In our current knowledge
of exoplanetary systems, alpha Centauri B b is the most promising target with
less than twenty-five Earth-masses for ZIMPOL. With a gaseous
Rayleigh-scattering atmosphere and favorable inclinations, the planet could be
detected in about four hours of observing time, using the four-quadrant
phase-mask coronograph in the I band. However, if alpha Centauri B b should
display unfavorable polarimetric and reflective properties similar to that of
our Moon, it is around 50 times fainter than the best sensitivity of ZIMPOL.
Alpha Centauri B is a primary target for SPHERE. Dedicated deep observations
specifically targeting the radial velocity-detected planet can lead to a
detection if the polarimetric properties of the planet are favorable.
[61]
oai:arXiv.org:1305.5143 [pdf] - 1171519
Calibration of quasi-static aberrations in exoplanet direct-imaging
instruments with a Zernike phase-mask sensor
Submitted: 2013-05-22, last modified: 2013-05-31
Context. Several exoplanet direct imaging instruments will soon be in
operation. They use an extreme adaptive optics (XAO) system to correct the
atmospheric turbulence and provide a highly-corrected beam to a near-infrared
(NIR) coronagraph for starlight suppression. The performance of the coronagraph
is however limited by the non-common path aberrations (NCPA) due to the
differential wavefront errors existing between the visible XAO sensing path and
the NIR science path, leading to residual speckles in the coronagraphic image.
Aims. Several approaches have been developed in the past few years to
accurately calibrate the NCPA, correct the quasi-static speckles and allow the
observation of exoplanets at least 1e6 fainter than their host star. We propose
an approach based on the Zernike phase-contrast method for the measurements of
the NCPA between the optical path seen by the visible XAO wavefront sensor and
that seen by the near-IR coronagraph. Methods. This approach uses a focal plane
phase mask of size {\lambda}/D, where {\lambda} and D denote the wavelength and
the telescope aperture diameter, respectively, to measure the quasi-static
aberrations in the upstream pupil plane by encoding them into intensity
variations in the downstream pupil image. We develop a rigorous formalism,
leading to highly accurate measurement of the NCPA, in a quasi-linear way
during the observation. Results. For a static phase map of standard deviation
44 nm rms at {\lambda} = 1.625 {\mu}m (0.026 {\lambda}), we estimate a possible
reduction of the chromatic NCPA by a factor ranging from 3 to 10 in the
presence of AO residuals compared with the expected performance of a typical
current-generation system. This would allow a reduction of the level of
quasi-static speckles in the detected images by a factor 10 to 100 hence,
correspondingly improving the capacity to observe exoplanets.
[62]
oai:arXiv.org:1302.7211 [pdf] - 1164927
Speckle temporal stability in XAO coronagraphic images II. Refine model
for quasi-static speckle temporal evolution for VLT/SPHERE
Submitted: 2013-02-28
Observing sequences have shown that the major noise source limitation in
high-contrast imaging is due to the presence of quasi-static speckles. The
timescale on which quasi-static speckles evolve, is determined by various
factors, among others mechanical or thermal deformations. Understanding of
these time-variable instrumental speckles, and especially their interaction
with other aberrations, referred to as the pinning effect, is paramount for the
search of faint stellar companions. The temporal evolution of quasi-static
speckles is for instance required for a quantification of the gain expected
when using angular differential imaging (ADI), and to determine the interval on
which speckle nulling techniques must be carried out. Following an early
analysis of a time series of adaptively corrected, coronagraphic images
obtained in a laboratory condition with the High-Order Test bench (HOT) at ESO
Headquarters, we confirm our results with new measurements carried out with the
SPHERE instrument during its final test phase in Europe. The analysis of the
residual speckle pattern in both direct and differential coronagraphic images
enables the characterization of the temporal stability of quasi-static
speckles. Data were obtained in a thermally actively controlled environment
reproducing realistic conditions encountered at the telescope. The temporal
evolution of the quasi-static wavefront error exhibits linear power law, which
can be used to model quasi-static speckle evolution in the context of
forthcoming high-contrast imaging instruments, with implications for
instrumentation (design, observing strategies, data reduction). Such a model
can be used for instance to derive the timescale on which non-common path
aberrations must be sensed and corrected. We found in our data that
quasi-static wavefront error increases with ~0.7 angstrom per minute.
[63]
oai:arXiv.org:1207.0768 [pdf] - 1124573
Multi-Object Spectroscopy with the European ELT: Scientific synergies
between EAGLE & EVE
Evans, C. J.;
Barbuy, B.;
Bonifacio, P.;
Chemla, F.;
Cuby, J. -G.;
Dalton, G. B.;
Davies, B.;
Disseau, K.;
Dohlen, K.;
Flores, H.;
Gendron, E.;
Guinouard, I.;
Hammer, F.;
Hastings, P.;
Horville, D.;
Jagourel, P.;
Kaper, L.;
Laporte, P.;
Lee, D.;
Morris, S. L.;
Morris, T.;
Myers, R.;
Navarro, R.;
Parr-Burman, P.;
Petitjean, P.;
Puech, M.;
Rollinde, E.;
Rousset, G.;
Schnetler, H.;
Welikala, N.;
Wells, M.;
Yang, Y.
Submitted: 2012-07-03
The EAGLE and EVE Phase A studies for instruments for the European Extremely
Large Telescope (E-ELT) originated from related top-level scientific questions,
but employed different (yet complementary) methods to deliver the required
observations. We re-examine the motivations for a multi-object spectrograph
(MOS) on the E-ELT and present a unified set of requirements for a versatile
instrument. Such a MOS would exploit the excellent spatial resolution in the
near-infrared envisaged for EAGLE, combined with aspects of the spectral
coverage and large multiplex of EVE. We briefly discuss the top-level systems
which could satisfy these requirements in a single instrument at one of the
Nasmyth foci of the E-ELT.
[64]
oai:arXiv.org:1111.3194 [pdf] - 1091625
Improved achromatization of phase mask coronagraphs using colored
apodization
Submitted: 2011-11-14
For direct imaging of exoplanets, a stellar coronagraph helps to remove the
image of an observed bright star by attenuating the diffraction effects caused
by the telescope aperture of diameter D. The Dual Zone Phase Mask (DZPM)
coronagraph constitutes a promising concept since it theoretically offers a
small inner working angle (IWA \sim \lambda_0/D), good achromaticity and high
starlight rejection, typically reaching a 1e6 contrast at 5 \lambda_0/D from
the star over a spectral bandwidth \Delta\lambda/\lambda_0 of 25% (similar to
H-band). This last value proves to be encouraging for broadband imaging of
young and warm Jupiter-like planets. Contrast levels higher than 1e6 are
however required for the observation of older and/or less massive companions
over a finite spectral bandwidth. An achromatization improvement of the DZPM
coronagraph is therefore mandatory to reach such performance. In its design,
the DZPM coronagraph uses a grey (or achromatic) apodization. We propose to
replace it by a colored apodization to increase the performance of this
coronagraphic system over a large spectral range. This innovative concept,
called Colored Apodizer Phase Mask (CAPM) coronagraph, is defined with some
design parameters optimized to reach the best contrast in the exoplanet search
area. Once this done, we study the performance of the CAPM coronagraph in the
presence of different errors to evaluate the sensitivity of our concept. A 2.5
mag contrast gain is estimated from the performance provided by the CAPM
coronagraph with respect to that of the DZPM coronagraph. A 2.2e-8 intensity
level at 5 \lambda_0/D separation is then theoretically achieved with the CAPM
coronagraph in the presence of a clear circular aperture and a 25% bandwidth.
In addition, our studies show that our concept is less sensitive to low than
high-order aberrations for a given value of rms wavefront errors.
[65]
oai:arXiv.org:1104.3859 [pdf] - 1053477
On-sky multi-wavelength phasing of segmented telescopes with the Zernike
phase contrast sensor
Submitted: 2011-04-19
Future Extremely Large Telescopes will adopt segmented primary mirrors with
several hundreds of segments. Cophasing of the segments together is essential
to reach high wavefront quality. The phasing sensor must be able to maintain
very high phasing accuracy during the observations, while being able to phase
segments dephased by several micrometers. The Zernike phase contrast sensor has
been demonstrated on-sky at the Very Large Telescope. We present the
multi-wavelength scheme that has been implemented to extend the capture range
from \pmlambda/2 on the wavefront to many micrometers, demonstrating that it is
successful at phasing mirrors with piston errors up to \pm4.0 micron on the
wavefront. We discuss the results at different levels and conclude with a
phasing strategy for a future Extremely Large Telescope.
[66]
oai:arXiv.org:1103.4766 [pdf] - 1790516
Simulation of planet detection with the SPHERE IFS
Mesa, D.;
Gratton, R.;
Berton, A.;
Antichi, J.;
Verinaud, C.;
Boccaletti, A.;
Kasper, M.;
Claudi, R. U.;
Desidera, S.;
Giro, E.;
Beuzit, J. -L.;
Dohlen, K.;
Feldt, M.;
Mouillet, D.;
Chauvin, G.;
Vigan, A.
Submitted: 2011-03-24
Aims. We present simulations of the perfomances of the future SPHERE IFS
instrument designed for imaging extrasolar planets in the near infrared (Y, J,
and H bands). Methods. We used the IDL package code for adaptive optics
simulation (CAOS) to prepare a series of input point spread functions (PSF).
These feed an IDL tool (CSP) that we designed to simulate the datacube
resulting from the SPHERE IFS. We performed simulations under different
conditions to evaluate the contrast that IFS will be able to reach and to
verify the impact of physical propagation within the limits of the near field
of the aperture approximation (i.e. Fresnel propagation). We then performed a
series of simulations containing planet images to test the capability of our
instrument to correctly classify the found objects. To this purpose we
developed a separated IDL tool. Results. We found that using the SPHERE IFS
instrument and appropriate analysis techniques, such as multiple spectral
differential imaging (MDI), spectral deconvolution (SD), and angular
differential imaging (ADI), we should be able to image companion objects down
to a luminosity contrast of ? 10-7 with respect to the central star in
favorable cases. Spectral deconvolution resulted in the most effective method
for reducing the speckle noise. We were then able to find most of the simulated
planets (more than 90% with the Y-J-mode and more than the 95% with the
Y-H-mode) for contrasts down to 3 \times 10-7 and separations between 0.3 and
1.0 arcsec. The spectral classification is accurate but seems to be more
precise for late T-type spectra than for earlier spectral types. A possible
degeneracy between early L-type companion objects and field objects (flat
spectra) is highlighted. The spectral classification seems to work better using
the Y-H-mode than with the Y-J-mode.
[67]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.
[68]
oai:arXiv.org:0806.0646 [pdf] - 127958
Apodized Pupil Lyot Coronagraph Working Without Lyot Stop
Submitted: 2008-06-03, last modified: 2010-03-09
In the context of high contrast imaging, we propose to evaluate the
performance of the Apodized Pupil Lyot Coronagraph (APLC) working without Lyot
Stop, namely Stop-less Lyot Coronagraph (SLLC). This coronagraph is a
combination of an entrance pupil apodizer and an opaque mask in the following
focal plane. However, contrary to APLC, SLLC is amputated by the traditional
pupil stop. Our goal is to stress the interest of using this coronagraphic
solution, in particular for instruments for which the introduction of a stellar
coronagraph with Lyot stop is made impossible. We estimate the intensity
attenuation achieved with SLLC and carry out our study with a focus on the case
of Gran Telescopio Canarias (GTC). In a first step, numerical simulations are
made assuming the absence of any aberration, thereafter SLLC performance is
evaluated considering AO corrected wavefronts in our approach for ground-based
instruments. SLLC performance proves to be equivalent to that obtained with
APLC in presence of AO compensated atmospheric turbulence images, which Strehl
ratio is S=0.552 at the wavelength lambda=1.57 mu m. This coronagraph allows to
remove the peak intensity of a star image and therefore, avoid detector
saturation. Moreover, it helps increasing the image dynamic range. A mean
contrast gain in stellar magnitudes Delta m=0.23 is obtained with SLLC whereas
APLC reaches a value Delta m=0.38.
[69]
oai:arXiv.org:0904.2481 [pdf] - 1001937
Design, analysis, and testing of a microdot apodizer for the Apodized
Pupil Lyot Coronagraph. II. The dot size impact. (Research Note)
Submitted: 2009-04-16
The Apodized Pupil Lyot Coronagraph (APLC) is a promising coronagraphic
device for direct exoplanets detection on the European-Extremely Large
Telescope. We present new near-IR laboratory results using binary apodizers --
the so-called microdots apodizer -- which represent a very attractive and
advantageous solution for the APLC.
Microdots apodizers introduce high-frequency noise whose characteristics
depend on the pixel size. The aim of this work is to characterize the impact of
the pixel size on the coronagraphic image. Estimation of both the noise
intensity and its localization in the field of view is the objective of this
study.
Stray-light diffraction introduced by the finite pixel size was measured
during experiment. Intensity decreases, and radial distance increases, when the
pixel size gets smaller.
The physical properties of these microdots apodizers have been demonstrated
in laboratory. The microdots apodizer is a suitable solution for any
coronagraph using pupil amplitude apodization if properly designed.
[70]
oai:arXiv.org:0901.3529 [pdf] - 900581
BIGRE: a low cross-talk integral field unit tailored for extrasolar
planets imaging spectroscopy
Antichi, Jacopo;
Dohlen, Kjetil;
Gratton, Raffaele G.;
Mesa, Dino;
Claudi, Riccardo U.;
Giro, Enrico;
Boccaletti, Anthony;
Mouillet, David;
Puget, Pascal;
Beuzit, Jean-Luc
Submitted: 2009-01-22
Integral field spectroscopy (IFS) represents a powerful technique for the
detection and characterization of extrasolar planets through high contrast
imaging, since it allows to obtain simultaneously a large number of
monochromatic images. These can be used to calibrate and then to reduce the
impact of speckles, once their chromatic dependence is taken into account. The
main concern in designing integral field spectrographs for high contrast
imaging is the impact of the diffraction effects and the non-common path
aberrations together with an efficient use of the detector pixels. We focus our
attention on integral field spectrographs based on lenslet-arrays, discussing
the main features of these designs: the conditions of appropriate spatial and
spectral sampling of the resulting spectrograph's slit functions and their
related cross-talk terms when the system works at the diffraction limit. We
present a new scheme for the integral field unit (IFU) based on a dual-lenslet
device (BIGRE), that solves some of the problems related to the classical TIGER
design when used for such applications. We show that BIGRE provides much lower
cross-talk signals than TIGER, allowing a more efficient use of the detector
pixels and a considerable saving of the overall cost of a lenslet-based
integral field spectrograph.
[71]
oai:arXiv.org:0901.2429 [pdf] - 20405
Apodized Lyot Coronagraph for VLT-SPHERE: Laboratory tests and
performances of a first prototype in the visible
Guerri, Géraldine;
Robbe-Dubois, Sylvie;
Daban, Jean-Baptiste;
Abe, Lyu;
Douet, Richard;
Bendjoya, Philippe;
Vakili, Farrokh;
Carbillet, Marcel;
Beuzit, Jean-Luc;
Puget, Pascal;
Dohlen, Kjetil;
Mouillet, David
Submitted: 2009-01-16
We present some of the High Dynamic Range Imaging activities developed around
the coronagraphic test-bench of the Laboratoire A. H. Fizeau (Nice). They
concern research and development of an Apodized Lyot Coronagraph (ALC) for the
VLT-SPHERE instrument and experimental results from our testbed working in the
visible domain. We determined by numerical simulations the specifications of
the apodizing filter and searched the best technological process to manufacture
it. We present the results of the experimental tests on the first apodizer
prototype in the visible and the resulting ALC nulling performances. The tests
concern particularly the apodizer characterization (average transmission radial
profile, global reflectivity and transmittivity in the visible), ALC nulling
performances compared with expectations, sensitivity of the ALC performances to
misalignments of its components.
[72]
oai:arXiv.org:0811.2496 [pdf] - 18579
Diversity among other worlds: characterization of exoplanets by direct
detection
Schneider, J.;
Boccaletti, A.;
Aylward, A.;
Baudoz, P.;
Beuzit, J. -L.;
Brown, R.;
Cho, J.;
Dohlen, K.;
Ferrari, M.;
Galicher, R.;
Grasset, O.;
Grenfell, L.;
Griessmeier, J. -M.;
Guyon, O.;
Hough, J.;
Kasper, M.;
Keller, Ch.;
Longmore, A.;
Lopez, B.;
Martin, E.;
Mawet, D.;
Menard, F.;
Merin, B.;
Palle, E.;
Perrin, G.;
Pinfield, D.;
Sein, E.;
Shore, P.;
Sotin, Ch.;
Sozzetti, A.;
Stam, D.;
Surdej, J.;
Tamburini, F.;
Tinetti, G.;
Udry, S.;
Verinaud, C.;
Walker, D.
Submitted: 2008-11-15, last modified: 2008-12-04
The physical characterization of exoplanets will require to take spectra at
several orbital positions. For that purpose, a direct imaging capability is
necessary. Direct imaging requires an efficient stellar suppression mechanism,
associated with an ultrasmooth telescope. We show that before future large
space missions (interferometer, 4-8 m class coronograph, external occulter or
Fresnel imager), direct imaging of giant planets and close-by super-Earth are
at the cross-road of a high scientific interest and a reasonable feasibility.
The scientific interest lies in the fact that super-Earths share common
geophysical attributes with Earths. They already begin to be detected by radial
velocity (RV) and, together with giant planets, they have a larger area than
Earths, making them detectable with a 1.5-2 m class telescope in reflected
light. We propose such a (space) telescope be a first step before large direct
imaging missions.
[73]
oai:arXiv.org:0810.5678 [pdf] - 18059
Design, analysis and test of a microdots apodizer for the Apodized Pupil
Lyot Coronagraph
Submitted: 2008-10-31
Coronagraphic techniques are required to detect exoplanets with future
Extremely Large Telescopes. One concept, the Apodized Pupil Lyot Coronagraph
(APLC), is combining an apodizer in the entrance aperture and a Lyot opaque
mask in the focal plane. This paper presents the manufacturing and tests of a
microdots apodizer optimized for the near IR.
The intent of this work is to demonstrate the feasibility and performance of
binary apodizers for the APLC. This study is also relevant for any coronagraph
using amplitude pupil apodization.
A binary apodizer has been designed using a halftone dot process, where the
binary array of pixels with either 0% or 100% transmission is calculated to fit
the required continuous transmission, i.e. local transmission control is
obtained by varying the relative density of the opaque and transparent pixels.
An error diffusion algorithm was used to optimize the distribution of pixels
that best approximates the required field transmission. The prototype was
tested with a coronagraphic setup in the near IR.
The transmission profile of the prototype agrees with the theoretical shape
within 3% and is achromatic. The observed apodized and coronagraphic images are
consistent with theory. However, binary apodizers introduce high frequency
noise that is a function of the pixel size. Numerical simulations were used to
specify pixel size in order to minimize this effect, and validated by
experiment.
This paper demonstrates that binary apodizers are well suited for being used
in high contrast imaging coronagraphs. The correct choice of pixel size is
important and must be adressed considering the scientific field of view.
[74]
oai:arXiv.org:0808.3817 [pdf] - 15735
Exoplanet characterization with long slit spectroscopy
Submitted: 2008-08-27
Extrasolar planets observation and characterization by high contrast imaging
instruments is set to be a very important subject in observational astronomy.
Dedicated instruments are being developed to achieve this goal with very high
efficiency. In particular, full spectroscopic characterization of low
temperature planetary companions is an extremely important milestone. We
present a new data analysis method for long slit spectroscopy (LSS) with
coronagraphy, which allows characterization of planetary companions of low
effective temperature. In a speckle-limited regime, this method allows an
accurate estimation and subtraction of the scattered starlight, to extract a
clean spectrum of the planetary companion. We performed intensive LSS
simulations with IDL/CAOS to obtain realistic spectra of low (R=35) and medium
(R=400) resolution in the J, H, and K bands. The simulated spectra were used to
test our method and estimate its performance in terms of contrast reduction and
extracted spectra quality. Our simulations are based on a software package
dedicated to the development of SPHERE, a second generation instrument for the
ESO-VLT. Our method allows a contrast reduction of 0.5 to 2.0 magnitudes
compared to the coronagraphic observations. For M0 and G0 stars located at 10
pc, we show that it would lead to the characterization of companions with Teff
of 600 K and 900 K respectively, at angular separations of 1.0 as. We also show
that errors in the wavelength calibration can produce significant errors in the
characterization, and must therefore be minimized as much as possible.
[75]
oai:arXiv.org:0807.0697 [pdf] - 14205
End to End Simulation of AO-assisted coronagraphic differential imaging:
estimation of performance for SPHERE
Submitted: 2008-07-04
SPHERE (Spectro Polarimetric High contrast Exoplanet REsearch), the planet
finder instrument for the VLT is designed to study relatively bright extrasolar
giant planets around young or nearby stars. SPHERE is a set of three
instruments fed by the same AO-system, two of them share the same coronagraph.
This complex system has been modeled with Fourier Optics to investigate the
performance of the whole instrument. In turns, this end-to-end model was useful
to analyze the sensitivity to various parameters (WFE, alignment of the
coronagraph, differential aberrations) and to put some specifications on the
sub-systems. This paper presents some example of sensitivity analysis and some
contrast performance of the instruments as a function of the flux for the main
observing mode of SPHERE: the Dual Band Imaging (DBI), equivalent to the
Spectral Differential Imaging technique.
[76]
oai:arXiv.org:0807.0694 [pdf] - 14204
Prototyping coronagraphs for exoplanet characterization with SPHERE
Boccaletti, Anthony;
Abe, Lyu;
Baudrand, Jacques;
Daban, Jean-Baptiste;
Douet, Richard;
Guerri, Geraldine;
Robbe-Dubois, Sylvie;
Bendjoya, Philippe;
Dohlen, Kjetil;
Mawet, Dimitri
Submitted: 2008-07-04
The detection and characterization of extrasolar planets with SPHERE (Spectro
Polarimetric High contrast Exoplanet REsearch) is challenging and in particular
relies on the ability of a coronagraph to attenuate the diffracted starlight.
SPHERE includes 3 instruments, 2 of which can be operated simultaneously in the
near IR from 0.95 to 1.8 microns. This requirements is extremely critical for
coronagraphy. This paper briefly introduces the concepts of 2 coronagraphs, the
Half-Wave Plate Four Quadrant Phase Masks and the Apodized Pupil Lyot
Coronagraph, prototyped within the SPHERE consortium by LESIA (Observatory of
Paris) and FIZEAU (University of Nice) respectively. Then, we present the
measurements of contrast and sensitivity analysis. The comparison with
technical specifications allows to validate the technology for manufacturing
these coronagraphs.
[77]
oai:arXiv.org:astro-ph/0606597 [pdf] - 83037
The Integral Field Spectrograph of SPHERE: the Planet Finder for VLT
Claudi, R. U.;
Turatto, M.;
Antichi, J.;
Gratton, R.;
Scuderi, S.;
Cascone, E.;
Mesa, D.;
Desidera, S.;
Baruffolo, A.;
Berton, A.;
Bagnara, P.;
Giro, E.;
Bruno, P.;
Fantinel, D.;
Beuzit, J. -L.;
Puget, P.;
Dohlen, K.
Submitted: 2006-06-23, last modified: 2006-06-30
SPHERE is an instrument designed and built by a consortium of French, German,
Italian, Swiss and Dutch institutes in collaboration with ESO. The project is
currently in its Phase B. The main goal of SPHERE is to gain at least one order
of magnitude with respect to the present VLT AO facility (NACO) in the direct
detection of faint objects very close to a bright star, especially giant
extrasolar planets. Apart from a high Strehl ratio, the instrument will be
designed to reduce the scattered light of the central bright star and subtract
the residual speckle halo. Sophisticated post-AO capabilities are needed to
provide maximum detectivity and possibly physical data on the putative planets.
The Integral Field Spectrograph (IFS), one of the three scientific channels
foreseen in the SPHERE design, is a very low resolution spectrograph (R~20)
which works in the near IR (0.95-1.35 micron), an ideal wavelength range for
the ground based detection of planetary features. Its goal is to suppress
speckle to a contrast of 10^7, with a goal of 10^8, and at the same time
provide spectral information in a field of view of about 1.5 x 1.5 arcsecs^2 in
proximity of the target star. In this paper we describe the overall IFS design
concept.
[78]
oai:arXiv.org:astro-ph/0512092 [pdf] - 78292
Analysis of ground-based differential imager performance
Submitted: 2005-12-05
In the context of extrasolar planet direct detection, we evaluated the
performance of differential imaging with ground-based telescopes. This study
was carried out in the framework of the VLT-Planet Finder project and is
further extended to the case of Extremely Large Telescopes. Our analysis is
providing critical specifications for future instruments mostly in terms of
phase aberrations but also regarding alignments of the instrument optics or
offset pointing on the coronagraph. It is found that Planet Finder projects on
8m class telescopes can be successful at detecting Extrasolar Giant Planets
providing phase aberrations, alignments and pointing are accurately controlled.
The situation is more pessimistic for the detection of terrestrial planets with
Extremely Large Telescopes for which phase aberrations must be lowered at a
very challenging level.
[79]
oai:arXiv.org:astro-ph/9807168 [pdf] - 102162
Multi-Object Spectroscopy in Space
Submitted: 1998-07-16
From the scientific objectives of the Next Generation Space Telescope, this
paper tries to constrain the design of the NGST Multi-Object Spectrograph.
Several technical alternatives are presented that could address the
requirements of the Design Reference Mission.