Normalized to: Doherty, P.
[1]
oai:arXiv.org:1911.00656 [pdf] - 2076708
An ultra-wide bandwidth (704 to 4032 MHz) receiver for the Parkes radio
telescope
Hobbs, G.;
Manchester, R. N.;
Dunning, A.;
Jameson, A.;
Roberts, P.;
George, D.;
Green, J. A.;
Tuthill, J.;
Toomey, L.;
Kaczmarek, J. F.;
Mader, S.;
Marquarding, M.;
Ahmed, A.;
Amy, S. W.;
Bailes, M.;
Beresford, R.;
Bhat, N. D. R.;
Bock, D. C. -J.;
Bourne, M.;
Bowen, M.;
Brothers, M.;
Cameron, A. D.;
Carretti, E.;
Carter, N.;
Castillo, S.;
Chekkala, R.;
Cheng, W.;
Chung, Y.;
Craig, D. A.;
Dai, S.;
Dawson, J. R.;
Dempsey, J.;
Doherty, P.;
Dong, B.;
Edwards, P. G.;
Ergesh, T.;
Gao, X. Y.;
Han, J. L.;
Hayman, D. B.;
Indermuehle, B. T.;
Jeganathan, K.;
Johnston, S.;
Kanoniuk, H.;
Kesteven, M.;
Kramer, M.;
Leach, M.;
Mcintyre, V. J.;
Moss, V. A.;
Oslowski, S.;
Phillips, C. J.;
Pope, N. C.;
Preisig, B.;
Price, D. C.;
Reeves, K.;
Reilly, L.;
Reynolds, J. E.;
Robishaw, T.;
Roush, P.;
Ruckley, T.;
Sadler, E. M.;
Sarkissian, J.;
Severs, S.;
Shannon, R. M.;
Smart, K. W.;
Smith, M.;
Sobey, S. L. Smith. C.;
Staveley-Smith, L.;
Tzioumis, A. K.;
van Straten, W.;
Wang, N.;
Wen, L.;
Whiting, M. T.
Submitted: 2019-11-02
We describe an ultra-wide-bandwidth, low-frequency receiver ("UWL") recently
installed on the Parkes radio telescope. The receiver system provides
continuous frequency coverage from 704 to 4032 MHz. For much of the band (~60%)
the system temperature is approximately 22K and the receiver system remains in
a linear regime even in the presence of strong mobile phone transmissions. We
discuss the scientific and technical aspects of the new receiver including its
astronomical objectives, as well as the feed, receiver, digitiser and
signal-processor design. We describe the pipeline routines that form the
archive-ready data products and how those data files can be accessed from the
archives. The system performance is quantified including the system noise and
linearity, beam shape, antenna efficiency, polarisation calibration and timing
stability.
[2]
oai:arXiv.org:0805.2366 [pdf] - 1934226
LSST: from Science Drivers to Reference Design and Anticipated Data
Products
Ivezić, Željko;
Kahn, Steven M.;
Tyson, J. Anthony;
Abel, Bob;
Acosta, Emily;
Allsman, Robyn;
Alonso, David;
AlSayyad, Yusra;
Anderson, Scott F.;
Andrew, John;
Angel, James Roger P.;
Angeli, George Z.;
Ansari, Reza;
Antilogus, Pierre;
Araujo, Constanza;
Armstrong, Robert;
Arndt, Kirk T.;
Astier, Pierre;
Aubourg, Éric;
Auza, Nicole;
Axelrod, Tim S.;
Bard, Deborah J.;
Barr, Jeff D.;
Barrau, Aurelian;
Bartlett, James G.;
Bauer, Amanda E.;
Bauman, Brian J.;
Baumont, Sylvain;
Becker, Andrew C.;
Becla, Jacek;
Beldica, Cristina;
Bellavia, Steve;
Bianco, Federica B.;
Biswas, Rahul;
Blanc, Guillaume;
Blazek, Jonathan;
Blandford, Roger D.;
Bloom, Josh S.;
Bogart, Joanne;
Bond, Tim W.;
Borgland, Anders W.;
Borne, Kirk;
Bosch, James F.;
Boutigny, Dominique;
Brackett, Craig A.;
Bradshaw, Andrew;
Brandt, William Nielsen;
Brown, Michael E.;
Bullock, James S.;
Burchat, Patricia;
Burke, David L.;
Cagnoli, Gianpietro;
Calabrese, Daniel;
Callahan, Shawn;
Callen, Alice L.;
Chandrasekharan, Srinivasan;
Charles-Emerson, Glenaver;
Chesley, Steve;
Cheu, Elliott C.;
Chiang, Hsin-Fang;
Chiang, James;
Chirino, Carol;
Chow, Derek;
Ciardi, David R.;
Claver, Charles F.;
Cohen-Tanugi, Johann;
Cockrum, Joseph J.;
Coles, Rebecca;
Connolly, Andrew J.;
Cook, Kem H.;
Cooray, Asantha;
Covey, Kevin R.;
Cribbs, Chris;
Cui, Wei;
Cutri, Roc;
Daly, Philip N.;
Daniel, Scott F.;
Daruich, Felipe;
Daubard, Guillaume;
Daues, Greg;
Dawson, William;
Delgado, Francisco;
Dellapenna, Alfred;
de Peyster, Robert;
de Val-Borro, Miguel;
Digel, Seth W.;
Doherty, Peter;
Dubois, Richard;
Dubois-Felsmann, Gregory P.;
Durech, Josef;
Economou, Frossie;
Eracleous, Michael;
Ferguson, Henry;
Figueroa, Enrique;
Fisher-Levine, Merlin;
Focke, Warren;
Foss, Michael D.;
Frank, James;
Freemon, Michael D.;
Gangler, Emmanuel;
Gawiser, Eric;
Geary, John C.;
Gee, Perry;
Geha, Marla;
Gessner, Charles J. B.;
Gibson, Robert R.;
Gilmore, D. Kirk;
Glanzman, Thomas;
Glick, William;
Goldina, Tatiana;
Goldstein, Daniel A.;
Goodenow, Iain;
Graham, Melissa L.;
Gressler, William J.;
Gris, Philippe;
Guy, Leanne P.;
Guyonnet, Augustin;
Haller, Gunther;
Harris, Ron;
Hascall, Patrick A.;
Haupt, Justine;
Hernandez, Fabio;
Herrmann, Sven;
Hileman, Edward;
Hoblitt, Joshua;
Hodgson, John A.;
Hogan, Craig;
Huang, Dajun;
Huffer, Michael E.;
Ingraham, Patrick;
Innes, Walter R.;
Jacoby, Suzanne H.;
Jain, Bhuvnesh;
Jammes, Fabrice;
Jee, James;
Jenness, Tim;
Jernigan, Garrett;
Jevremović, Darko;
Johns, Kenneth;
Johnson, Anthony S.;
Johnson, Margaret W. G.;
Jones, R. Lynne;
Juramy-Gilles, Claire;
Jurić, Mario;
Kalirai, Jason S.;
Kallivayalil, Nitya J.;
Kalmbach, Bryce;
Kantor, Jeffrey P.;
Karst, Pierre;
Kasliwal, Mansi M.;
Kelly, Heather;
Kessler, Richard;
Kinnison, Veronica;
Kirkby, David;
Knox, Lloyd;
Kotov, Ivan V.;
Krabbendam, Victor L.;
Krughoff, K. Simon;
Kubánek, Petr;
Kuczewski, John;
Kulkarni, Shri;
Ku, John;
Kurita, Nadine R.;
Lage, Craig S.;
Lambert, Ron;
Lange, Travis;
Langton, J. Brian;
Guillou, Laurent Le;
Levine, Deborah;
Liang, Ming;
Lim, Kian-Tat;
Lintott, Chris J.;
Long, Kevin E.;
Lopez, Margaux;
Lotz, Paul J.;
Lupton, Robert H.;
Lust, Nate B.;
MacArthur, Lauren A.;
Mahabal, Ashish;
Mandelbaum, Rachel;
Marsh, Darren S.;
Marshall, Philip J.;
Marshall, Stuart;
May, Morgan;
McKercher, Robert;
McQueen, Michelle;
Meyers, Joshua;
Migliore, Myriam;
Miller, Michelle;
Mills, David J.;
Miraval, Connor;
Moeyens, Joachim;
Monet, David G.;
Moniez, Marc;
Monkewitz, Serge;
Montgomery, Christopher;
Mueller, Fritz;
Muller, Gary P.;
Arancibia, Freddy Muñoz;
Neill, Douglas R.;
Newbry, Scott P.;
Nief, Jean-Yves;
Nomerotski, Andrei;
Nordby, Martin;
O'Connor, Paul;
Oliver, John;
Olivier, Scot S.;
Olsen, Knut;
O'Mullane, William;
Ortiz, Sandra;
Osier, Shawn;
Owen, Russell E.;
Pain, Reynald;
Palecek, Paul E.;
Parejko, John K.;
Parsons, James B.;
Pease, Nathan M.;
Peterson, J. Matt;
Peterson, John R.;
Petravick, Donald L.;
Petrick, M. E. Libby;
Petry, Cathy E.;
Pierfederici, Francesco;
Pietrowicz, Stephen;
Pike, Rob;
Pinto, Philip A.;
Plante, Raymond;
Plate, Stephen;
Price, Paul A.;
Prouza, Michael;
Radeka, Veljko;
Rajagopal, Jayadev;
Rasmussen, Andrew P.;
Regnault, Nicolas;
Reil, Kevin A.;
Reiss, David J.;
Reuter, Michael A.;
Ridgway, Stephen T.;
Riot, Vincent J.;
Ritz, Steve;
Robinson, Sean;
Roby, William;
Roodman, Aaron;
Rosing, Wayne;
Roucelle, Cecille;
Rumore, Matthew R.;
Russo, Stefano;
Saha, Abhijit;
Sassolas, Benoit;
Schalk, Terry L.;
Schellart, Pim;
Schindler, Rafe H.;
Schmidt, Samuel;
Schneider, Donald P.;
Schneider, Michael D.;
Schoening, William;
Schumacher, German;
Schwamb, Megan E.;
Sebag, Jacques;
Selvy, Brian;
Sembroski, Glenn H.;
Seppala, Lynn G.;
Serio, Andrew;
Serrano, Eduardo;
Shaw, Richard A.;
Shipsey, Ian;
Sick, Jonathan;
Silvestri, Nicole;
Slater, Colin T.;
Smith, J. Allyn;
Smith, R. Chris;
Sobhani, Shahram;
Soldahl, Christine;
Storrie-Lombardi, Lisa;
Stover, Edward;
Strauss, Michael A.;
Street, Rachel A.;
Stubbs, Christopher W.;
Sullivan, Ian S.;
Sweeney, Donald;
Swinbank, John D.;
Szalay, Alexander;
Takacs, Peter;
Tether, Stephen A.;
Thaler, Jon J.;
Thayer, John Gregg;
Thomas, Sandrine;
Thukral, Vaikunth;
Tice, Jeffrey;
Trilling, David E.;
Turri, Max;
Van Berg, Richard;
Berk, Daniel Vanden;
Vetter, Kurt;
Virieux, Francoise;
Vucina, Tomislav;
Wahl, William;
Walkowicz, Lucianne;
Walsh, Brian;
Walter, Christopher W.;
Wang, Daniel L.;
Wang, Shin-Yawn;
Warner, Michael;
Wiecha, Oliver;
Willman, Beth;
Winters, Scott E.;
Wittman, David;
Wolff, Sidney C.;
Wood-Vasey, W. Michael;
Wu, Xiuqin;
Xin, Bo;
Yoachim, Peter;
Zhan, Hu
Submitted: 2008-05-15, last modified: 2018-05-23
(Abridged) We describe here the most ambitious survey currently planned in
the optical, the Large Synoptic Survey Telescope (LSST). A vast array of
science will be enabled by a single wide-deep-fast sky survey, and LSST will
have unique survey capability in the faint time domain. The LSST design is
driven by four main science themes: probing dark energy and dark matter, taking
an inventory of the Solar System, exploring the transient optical sky, and
mapping the Milky Way. LSST will be a wide-field ground-based system sited at
Cerro Pach\'{o}n in northern Chile. The telescope will have an 8.4 m (6.5 m
effective) primary mirror, a 9.6 deg$^2$ field of view, and a 3.2 Gigapixel
camera. The standard observing sequence will consist of pairs of 15-second
exposures in a given field, with two such visits in each pointing in a given
night. With these repeats, the LSST system is capable of imaging about 10,000
square degrees of sky in a single filter in three nights. The typical 5$\sigma$
point-source depth in a single visit in $r$ will be $\sim 24.5$ (AB). The
project is in the construction phase and will begin regular survey operations
by 2022. The survey area will be contained within 30,000 deg$^2$ with
$\delta<+34.5^\circ$, and will be imaged multiple times in six bands, $ugrizy$,
covering the wavelength range 320--1050 nm. About 90\% of the observing time
will be devoted to a deep-wide-fast survey mode which will uniformly observe a
18,000 deg$^2$ region about 800 times (summed over all six bands) during the
anticipated 10 years of operations, and yield a coadded map to $r\sim27.5$. The
remaining 10\% of the observing time will be allocated to projects such as a
Very Deep and Fast time domain survey. The goal is to make LSST data products,
including a relational database of about 32 trillion observations of 40 billion
objects, available to the public and scientists around the world.
[3]
oai:arXiv.org:1805.05867 [pdf] - 1682842
A collimated beam projector for precise telescope calibration
Coughlin, Michael;
Abbott, T. M. C.;
Brannon, Kairn;
Claver, Chuck;
Doherty, Peter;
Fisher-Levine, Merlin;
Ingraham, Patrick;
Lupton, Robert;
Mondrik, Nicholas;
Stubbs, Christopher
Submitted: 2018-05-15
The precise determination of the instrumental response function versus
wavelength is a central ingredient in contemporary photometric calibration
strategies. This typically entails propagating narrowband illumination through
the system pupil, and comparing the detected photon rate across the focal plane
to the amount of incident light as measured by a calibrated photodiode.
However, stray light effects and reflections/ghosting (especially on the edges
of filter passbands) in the optical train constitute a major source of
systematic uncertainty when using a flat-field screen as the illumination
source. A collimated beam projector that projects a mask onto the focal plane
of the instrument can distinguish focusing light paths from stray and scattered
light, allowing for a precise determination of instrumental throughput. This
paper describes the conceptual design of such a system, outlines its merits,
and presents results from a prototype system used with the Dark Energy Camera
wide field imager on the 4-meter Blanco telescope. A calibration scheme that
blends results from flat-field images with collimated beam projector data to
obtain the equivalent of an illumination correction at high spectral and
angular resolution is also presented. In addition to providing a precise system
throughput calibration, by monitoring the evolution of the intensity and
behaviour of the ghosts in the optical system, the collimated beam projector
can be used to track the evolution of the filter transmission properties and
various anti-reflective coatings in the optical system.
[4]
oai:arXiv.org:1707.04237 [pdf] - 1636634
A Digital Correlator Upgrade for the Arcminute MicroKelvin Imager
Hickish, Jack;
Razavi-Ghods, Nima;
Perrott, Yvette C.;
Titterington, David J.;
Carey, Steve H.;
Scott, Paul F.;
Grainge, Keith J. B.;
Scaife, Anna M. M.;
Alexander, Paul;
Saunders, Richard D. E.;
Crofts, Mike;
Javid, Kamran;
Rumsey, Clare;
Jin, Terry Z.;
Ely, John A.;
Shaw, Clive;
Northrop, Ian G.;
Pooley, Guy;
D'Alessandro, Robert;
Doherty, Peter;
Willatt, Greg P.
Submitted: 2017-07-13, last modified: 2018-02-16
The Arcminute Microkelvin Imager (AMI) telescopes located at the Mullard
Radio Astronomy Observatory near Cambridge have been significantly enhanced by
the implementation of a new digital correlator with 1.2 MHz spectral
resolution. This system has replaced a 750-MHz resolution analogue lag-based
correlator, and was designed to mitigate the effects of radio frequency
interference, particularly from geostationary satellites that contaminate
observations at low declinations. The upgraded instrument consists of 18 ROACH2
Field Programmable Gate Array platforms used to implement a pair of real-time
FX correlators -- one for each of AMI's two arrays. The new system separates
the down-converted RF baseband signal from each AMI receiver into two 2.3
GHz-wide sub-bands which are each digitized at 5-Gsps with 8 bits of precision.
These digital data streams are filtered into 2048 frequency channels and
cross-correlated using FPGA hardware, with a commercial 10 Gb Ethernet switch
providing high-speed data interconnect. Images formed using data from the new
digital correlator show over an order of magnitude improvement in dynamic range
over the previous system. The ability to observe at low declinations has also
been significantly improved.
[5]
oai:arXiv.org:1608.01964 [pdf] - 1531202
High fidelity point-spread function retrieval in the presence of
electrostatic, hysteretic pixel response
Rasmussen, Andrew;
Guyonnet, Augustin;
Lage, Craig;
Antilogus, Pierre;
Astier, Pierre;
Doherty, Peter;
Gilmore, Kirk;
Kotov, Ivan;
Lupton, Robert;
Nomerotski, Andrei;
O'Connor, Paul;
Stubbs, Christopher;
Tyson, Anthony;
Walter, Christopher
Submitted: 2016-08-05, last modified: 2016-09-12
We employ electrostatic conversion drift calculations to match CCD pixel
signal covariances observed in flat field exposures acquired using candidate
sensor devices for the LSST Camera. We thus constrain pixel geometry
distortions present at the end of integration, based on signal images recorded.
We use available data from several operational voltage parameter settings to
validate our understanding. Our primary goal is to optimize flux point-spread
function (FPSF) estimation quantitatively, and thereby minimize sensor-induced
errors which may limit performance in precision astronomy applications. We
consider alternative compensation scenarios that will take maximum advantage of
our understanding of this underlying mechanism in data processing pipelines
currently under development.
To quantitatively capture the pixel response in high-contrast/high dynamic
range operational extrema, we propose herein some straightforward laboratory
tests that involve altering the time order of source illumination on sensors,
within individual test exposures. Hence the word {\it hysteretic} in the title
of this paper.
[6]
oai:arXiv.org:1501.01577 [pdf] - 936263
Evidence for self-interaction of charge distribution in charge-coupled
devices
Submitted: 2015-01-07, last modified: 2015-01-08
Charge-coupled devices (CCDs) are widely used in astronomy to carry out a
variety of measurements, such as for flux or shape of astrophysical objects.
The data reduction procedures almost always assume that ther esponse of a given
pixel to illumination is independent of the content of the neighboring pixels.
We show evidence that this simple picture is not exact for several CCD sensors.
Namely, we provide evidence that localized distributions of charges (resulting
from star illumination or laboratory luminous spots) tend to broaden linearly
with increasing brightness by up to a few percent over the whole dynamic range.
We propose a physical explanation for this "brighter-fatter" effect, which
implies that flatfields do not exactly follow Poisson statistics: the variance
of flatfields grows less rapidly than their average, and neighboring pixels
show covariances, which increase similarly to the square of the flatfield
average. These covariances decay rapidly with pixel separation. We observe the
expected departure from Poisson statistics of flatfields on CCD devices and
show that the observed effects are compatible with Coulomb forces induced by
stored charges that deflect forthcoming charges. We extract the strength of the
deflections from the correlations of flatfield images and derive the evolution
of star shapes with increasing flux. We show for three types of sensors that
within statistical uncertainties,our proposed method properly bridges
statistical properties of flatfields and the brighter-fatter effect.
[7]
oai:arXiv.org:1407.5655 [pdf] - 1215813
A framework for modeling the detailed optical response of thick,
multiple segment, large format sensors for precision astronomy applications
Rasmussen, Andrew;
Antilogus, Pierre;
Astier, Pierre;
Claver, Chuck;
Doherty, Peter;
Dubois-Felsmann, Gregory;
Gilmore, Kirk;
Kahn, Steven;
Kotov, Ivan;
Lupton, Robert;
O'Connor, Paul;
Nomerotski, Andrei;
Ritz, Steve;
Stubbs, Christopher
Submitted: 2014-07-21, last modified: 2014-07-23
Near-future astronomical survey experiments, such as LSST, possess system
requirements of unprecedented fidelity that span photometry, astrometry and
shape transfer. Some of these requirements flow directly to the array of
science imaging sensors at the focal plane. Availability of high quality
characterization data acquired in the course of our sensor development program
has given us an opportunity to develop and test a framework for simulation and
modeling that is based on a limited set of physical and geometric effects. In
this paper we describe those models, provide quantitative comparisons between
data and modeled response, and extrapolate the response model to predict
imaging array response to astronomical exposure. The emergent picture departs
from the notion of a fixed, rectilinear grid that maps photo-conversions to the
potential well of the channel. In place of that, we have a situation where
structures from device fabrication, local silicon bulk resistivity variations
and photo-converted carrier patterns still accumulating at the channel,
together influence and distort positions within the photosensitive volume that
map to pixel boundaries. Strategies for efficient extraction of modeling
parameters from routinely acquired characterization data are described. Methods
for high fidelity illumination/image distribution parameter retrieval, in the
presence of such distortions, are also discussed.
[8]
oai:arXiv.org:1402.0725 [pdf] - 1203166
The brighter-fatter effect and pixel correlations in CCD sensors
Submitted: 2014-02-04
We present evidence that spots imaged using astronomical CCDs do not exactly
scale with flux: bright spots tend to be broader than faint ones, using the
same illumination pattern. We measure that the linear size of spots or stars,
of typical size 3 to 4 pixels FWHM, increase linearly with their flux by up to
$2\%$ over the full CCD dynamic range. This brighter-fatter effect affects both
deep-depleted and thinned CCD sensors. We propose that this effect is a direct
consequence of the distortions of the drift electric field sourced by charges
accumulated within the CCD during the exposure and experienced by forthcoming
light-induced charges in the same exposure. The pixel boundaries then become
slightly dynamical: overfilled pixels become increasingly smaller than their
neighbors, so that bright star sizes, measured in number of pixels, appear
larger than those of faint stars. This interpretation of the brighter-fatter
effect implies that pixels in flat-fields should exhibit statistical
correlations, sourced by Poisson fluctuations, that we indeed directly detect.
We propose to use the measured correlations in flat-fields to derive how pixel
boundaries shift under the influence of a given charge pattern, which allows us
to quantitatively predict how star shapes evolve with flux. This physical model
of the brighter-fatter effect also explains the commonly observed phenomenon
that the spatial variance of CCD flat-fields increases less rapidly than their
average.
[9]
oai:arXiv.org:1012.4441 [pdf] - 1042682
A blind detection of a large, complex, Sunyaev--Zel'dovich structure
Consortium, AMI;
:;
Shimwell, T. W.;
Barker, R. W.;
Biddulph, P.;
Bly, D.;
Boysen, R. C.;
Brown, A. R.;
Brown, M. L.;
Clementson, C.;
Crofts, M.;
Culverhouse, T. L.;
Czeres, J.;
Dace, R. J.;
Davies, M. L.;
D'Alessandro, R.;
Doherty, P.;
Duggan, K.;
Ely, J. A.;
Felvus, M.;
Feroz, F.;
Flynn, W.;
Franzen, T. M. O.;
Geisbusch, J.;
Genova-Santos, R.;
Grainge, K. J. B.;
Grainger, W. F.;
Hammett, D.;
Hobson, M. P.;
Holler, C. M.;
Hurley-Walker, N.;
Jilley, R.;
Kaneko, T.;
Kneissl, R.;
Lancaster, K.;
Lasenby, A. N.;
Marshall, P. J.;
Newton, F.;
Norris, O.;
Northrop, I.;
Odell, D. M.;
Olamaie, M.;
Pober, Y. C. Perrott J. C.;
Pooley, G. G.;
Pospieszalski, M. W.;
Quy, V.;
Rodriguez-Gonzalvez, C.;
Saunders, R. D. E.;
Scaife, A. M. M.;
Schammel, M. P.;
Schofield, J.;
Scott, P. F.;
Shaw, C.;
Smith, H.;
Titterington, D. J.;
Velic, M.;
Waldram, E. M.;
West, S.;
Wood, B. A.;
Yassin, G.;
Zwart, J. T. L.
Submitted: 2010-12-20, last modified: 2012-03-22
We present an interesting Sunyaev-Zel'dovich (SZ) detection in the first of
the Arcminute Microkelvin Imager (AMI) 'blind', degree-square fields to have
been observed down to our target sensitivity of 100{\mu}Jy/beam. In follow-up
deep pointed observations the SZ effect is detected with a maximum peak
decrement greater than 8 \times the thermal noise. No corresponding emission is
visible in the ROSAT all-sky X-ray survey and no cluster is evident in the
Palomar all-sky optical survey. Compared with existing SZ images of distant
clusters, the extent is large (\approx 10') and complex; our analysis favours a
model containing two clusters rather than a single cluster. Our Bayesian
analysis is currently limited to modelling each cluster with an ellipsoidal or
spherical beta-model, which do not do justice to this decrement. Fitting an
ellipsoid to the deeper candidate we find the following. (a) Assuming that the
Evrard et al. (2002) approximation to Press & Schechter (1974) correctly gives
the number density of clusters as a function of mass and redshift, then, in the
search area, the formal Bayesian probability ratio of the AMI detection of this
cluster is 7.9 \times 10^4:1; alternatively assuming Jenkins et al. (2001) as
the true prior, the formal Bayesian probability ratio of detection is 2.1
\times 10^5:1. (b) The cluster mass is MT,200 = 5.5+1.2\times 10^14h-1M\odot.
(c) Abandoning a physical model with num- -1.3 70 ber density prior and instead
simply modelling the SZ decrement using a phenomenological {\beta}-model of
temperature decrement as a function of angular distance, we find a central SZ
temperature decrement of -295+36 {\mu}K - this allows for CMB primary
anisotropies, receiver -15 noise and radio sources. We are unsure if the
cluster system we observe is a merging system or two separate clusters.
[10]
oai:arXiv.org:1203.0297 [pdf] - 1117014
The Pan-STARRS1 Photometric System
Tonry, J. L.;
Stubbs, C. W.;
Lykke, K. R.;
Doherty, P.;
Shivvers, I. S.;
Burgett, W. S.;
Chambers, K. C.;
Hodapp, K. W.;
Kaiser, N.;
Kudritzki, R. -P.;
Magnier, E. A.;
Morgan, J. S.;
Price, P. A.;
Wainscoat, R. J.
Submitted: 2012-02-29
The Pan-STARRS1 survey is collecting multi-epoch, multi-color observations of
the sky north of declination -30 deg to unprecedented depths. These data are
being photometrically and astrometrically calibrated and will serve as a
reference for many other purposes. In this paper we present our determination
of the Pan-STARRS photometric system: gp1, rp1, ip1, zp1, yp1, and wp1. The
Pan-STARRS photometric system is fundamentally based on the HST Calspec
spectrophotometric observations, which in turn are fundamentally based on
models of white dwarf atmospheres. We define the Pan-STARRS magnitude system,
and describe in detail our measurement of the system passbands, including both
the instrumental sensitivity and atmospheric transmission functions.
Byproducts, including transformations to other photometric systems, galactic
extinction, and stellar locus are also provided. We close with a discussion of
remaining systematic errors.
[11]
oai:arXiv.org:1003.3465 [pdf] - 1025778
Precise Throughput Determination of the PanSTARRS Telescope and the
Gigapixel Imager using a Calibrated Silicon Photodiode and a Tunable Laser:
Initial Results
Submitted: 2010-03-17
We have used a precision calibrated photodiode as the fundamental metrology
reference in order to determine the relative throughput of the PanSTARRS
telescope and the Gigapixel imager, from 400 nm to 1050 nm. Our technique uses
a tunable laser as a source of illumination on a transmissive flat-field
screen. We determine the full-aperture system throughput as a function of
wavelength, including (in a single integral measurement) the mirror
reflectivity, the transmission functions of the filters and the corrector
optics, and the detector quantum efficiency, by comparing the light seen by
each pixel in the CCD array to that measured by a precision-calibrated silicon
photodiode. This method allows us to determine the relative throughput of the
entire system as a function of wavelength, for each pixel in the instrument,
without observations of celestial standards. We present promising initial
results from this characterization of the PanSTARRS system, and we use
synthetic photometry to assess the photometric perturbations due to throughput
variation across the field of view.
[12]
oai:arXiv.org:0807.2469 [pdf] - 554051
The Arcminute Microkelvin Imager
Consortium, AMI;
:;
Zwart, J. T. L.;
Barker, R. W.;
Biddulph, P.;
Bly, D.;
Boysen, R. C.;
Brown, A. R.;
Clementson, C.;
Crofts, M.;
Culverhouse, T. L.;
Czeres, J.;
Dace, R. J.;
Davies, M. L.;
D'Alessandro, R.;
Doherty, P.;
Duggan, K.;
Ely, J. A.;
Felvus, M.;
Feroz, F.;
Flynn, W.;
Franzen, T. M. O.;
Geisbüsch, J.;
Génova-Santos, R.;
Grainge, K. J. B.;
Grainger, W. F.;
Hammett, D.;
Hills, R. E.;
Hobson, M. P.;
Holler, C. M.;
Hurley-Walker, N.;
Jilley, R.;
Jones, M. E.;
Kaneko, T.;
Kneissl, R.;
Lancaster, K.;
Lasenby, A. N.;
Marshall, P. J.;
Newton, F.;
Norris, O.;
Northrop, I.;
Odell, D. M.;
Pober, J. C.;
Pooley, G. G.;
Quy, V.;
Rodríguez-Gonzálvez, C.;
Saunders, R. D. E.;
Scaife, A. M.;
Schofield, J.;
Scott, P. F.;
Shaw, C.;
Shimwell, T. W.;
Smith, H.;
Taylor, A. C.;
Titterington, D. J.;
Velić, M.;
Waldram, E. M.;
West, S.;
Wood, B. A.;
Yassin, G.
Submitted: 2008-07-15
The Arcminute Microkelvin Imager is a pair of interferometer arrays operating
with six frequency channels spanning 13.9-18.2 GHz, with very high sensitivity
to angular scales 30''-10'. The telescope is aimed principally at
Sunyaev-Zel'dovich imaging of clusters of galaxies. We discuss the design of
the telescope and describe and explain its electronic and mechanical systems.
[13]
oai:arXiv.org:astro-ph/0509215 [pdf] - 75797
High-significance Sunyaev-Zel'dovich measurement: Abell 1914 seen with
the Arcminute Microkelvin Imager
AMI Collaboration;
Barker, R.;
Biddulph, P.;
Bly, D.;
Boysen, R.;
Brown, A.;
Clementson, C.;
Crofts, M.;
Culverhouse, T.;
Czeres, J.;
Dace, R.;
D'Alessandro, R.;
Doherty, P.;
Duffett-Smith, P.;
Duggan, K.;
Ely, J.;
Felvus, M.;
Flynn, W.;
Geisbuesch, J.;
Grainge, K.;
Grainger, W.;
Hammet, D.;
Hills, R.;
Hobson, M.;
Holler, C.;
Jilley, R.;
Jones, M.;
Kaneko, T.;
Kneissl, R.;
Lancaster, K.;
Lasenby, A.;
Marshall, P.;
Newton, F.;
Norris, O.;
Northrop, I.;
Pooley, G.;
Quy, V.;
Saunders, R.;
Scaife, A.;
Schofield, J.;
Scott, P.;
Shaw, C.;
Taylor, A.;
Titterington, D.;
Velic, M.;
Waldram, E.;
West, S.;
Wood, B.;
Yassin, G.;
Zwart, J.
Submitted: 2005-09-08
We report the first detection of a Sunyaev-Zel'dovich (S-Z) decrement with
the Arcminute Microkelvin Imager (AMI). We have made commissioning observations
towards the cluster A1914 and have measured an integrated flux density of -8.61
mJy in a uv-tapered map with noise level 0.19 mJy/beam. We find that the
spectrum of the decrement, measured in the six channels between 13.5-18GHz, is
consistent with that expected for a S-Z effect. The sensitivity of the
telescope is consistent with the figures used in our simulations of cluster
surveys with AMI.