sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Doelman, David S.

Normalized to: Doelman, D.

18 article(s) in total. 285 co-authors, from 1 to 18 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:2004.06157  [pdf] - 2093295
First Images of the Protoplanetary Disk Around PDS 201
Comments: Accepted for publication in AJ
Submitted: 2020-04-13, last modified: 2020-04-30
Scattered light imaging has revealed nearly a dozen circumstellar disks around young Herbig Ae/Be stars$-$enabling studies of structures in the upper disk layers as potential signs of on-going planet formation. We present the first images of the disk around the variable Herbig Ae star PDS 201 (V* V351 Ori), and an analysis of the images and spectral energy distribution through 3D Monte-Carlo radiative transfer simulations and forward modelling. The disk is detected in three datasets with LBTI/LMIRCam at the LBT, including direct observations in the $Ks$ and $L'$ filters, and an $L'$ observation with the 360$^\circ$ vector apodizing phase plate coronagraph. The scattered light disk extends to a very large radius of $\sim$250 au, which places it among the largest of such disks. Exterior to the disk, we establish detection limits on substellar companions down to $\sim$5 M$_{Jup}$ at $\gtrsim$1.5" ($\gtrsim$500 au), assuming the Baraffe et al. (2015) models. The images show a radial gap extending to $\sim$0.4" ($\sim$140 au at a distance of 340 pc) that is also evident in the spectral energy distribution. The large gap is a possible signpost of multiple high-mass giant planets at orbital distances ($\sim$60-100 au) that are unusually massive and widely-separated compared to those of planet populations previously inferred from protoplanetary disk substructures.
[2]  oai:arXiv.org:2003.05714  [pdf] - 2063822
SPHERE+: Imaging young Jupiters down to the snowline
Boccaletti, A.; Chauvin, G.; Mouillet, D.; Absil, O.; Allard, F.; Antoniucci, S.; Augereau, J. -C.; Barge, P.; Baruffolo, A.; Baudino, J. -L.; Baudoz, P.; Beaulieu, M.; Benisty, M.; Beuzit, J. -L.; Bianco, A.; Biller, B.; Bonavita, B.; Bonnefoy, M.; Bos, S.; Bouret, J. -C.; Brandner, W.; Buchschache, N.; Carry, B.; Cantalloube, F.; Cascone, E.; Carlotti, A.; Charnay, B.; Chiavassa, A.; Choquet, E.; Clenet, Y.; Crida, A.; De Boer, J.; De Caprio, V.; Desidera, S.; Desert, J. -M.; Delisle, J. -B.; Delorme, P.; Dohlen, K.; Doelman, D.; Dominik, C.; Orazi, V. D; Dougados, C.; Doute, S.; Fedele, D.; Feldt, M.; Ferreira, F.; Fontanive, C.; Fusco, T.; Galicher, R.; Garufi, A.; Gendron, E.; Ghedina, A.; Ginski, C.; Gonzalez, J. -F.; Gratadour, D.; Gratton, R.; Guillot, T.; Haffert, S.; Hagelberg, J.; Henning, T.; Huby, E.; Janson, M.; Kamp, I.; Keller, C.; Kenworthy, M.; Kervella, P.; Kral, Q.; Kuhn, J.; Lagadec, E.; Laibe, G.; Langlois, M.; Lagrange, A. -M.; Launhardt, R.; Leboulleux, L.; Coroller, H. Le; Causi, G. Li; Loupias, M.; Maire, A. L.; Marleau, G.; Martinache, F.; Martinez, P.; Mary, D.; Mattioli, M.; Mazoyer, J.; Meheut, H.; Menard, F.; Mesa, D.; Meunier, N.; Miguel, Y.; Milli, J.; Min, M.; Molliere, P.; Mordasini, C.; Moretto, G.; Mugnier, L.; Arena, G. Muro; Nardetto, N.; Diaye, M. N; Nesvadba, N.; Pedichini, F.; Pinilla, P.; Por, E.; Potier, A.; Quanz, S.; Rameau, J.; Roelfsema, R.; Rouan, D.; Rigliaco, E.; Salasnich, B.; Samland, M.; Sauvage, J. -F.; Schmid, H. -M.; Segransan, D.; Snellen, I.; Snik, F.; Soulez, F.; Stadler, E.; Stam, D.; Tallon, M.; Thebault, P.; Thiebaut, E.; Tschudi, C.; Udry, S.; van Holstein, R.; Vernazza, P.; Vidal, F.; Vigan, A.; Waters, R.; Wildi, F.; Willson, M.; Zanutta, A.; Zavagno, A.; Zurlo, A.
Comments: White paper submitted to ESO on Feb. 20th, 2020
Submitted: 2020-03-12, last modified: 2020-03-13
SPHERE (Beuzit et al,. 2019) has now been in operation at the VLT for more than 5 years, demonstrating a high level of performance. SPHERE has produced outstanding results using a variety of operating modes, primarily in the field of direct imaging of exoplanetary systems, focusing on exoplanets as point sources and circumstellar disks as extended objects. The achievements obtained thus far with SPHERE (~200 refereed publications) in different areas (exoplanets, disks, solar system, stellar physics...) have motivated a large consortium to propose an even more ambitious set of science cases, and its corresponding technical implementation in the form of an upgrade. The SPHERE+ project capitalizes on the expertise and lessons learned from SPHERE to push high contrast imaging performance to its limits on the VLT 8m-telescope. The scientific program of SPHERE+ described in this document will open a new and compelling scientific window for the upcoming decade in strong synergy with ground-based facilities (VLT/I, ELT, ALMA, and SKA) and space missions (Gaia, JWST, PLATO and WFIRST). While SPHERE has sampled the outer parts of planetary systems beyond a few tens of AU, SPHERE+ will dig into the inner regions around stars to reveal and characterize by mean of spectroscopy the giant planet population down to the snow line. Building on SPHERE's scientific heritage and resounding success, SPHERE+ will be a dedicated survey instrument which will strengthen the leadership of ESO and the European community in the very competitive field of direct imaging of exoplanetary systems. With enhanced capabilities, it will enable an even broader diversity of science cases including the study of the solar system, the birth and death of stars and the exploration of the inner regions of active galactic nuclei.
[3]  oai:arXiv.org:2002.05622  [pdf] - 2063298
Minimizing the polarization leakage of geometric-phase coronagraphs with multiple grating pattern combinations
Comments: 23 pages, 15 figures, accepted for publication in PASP
Submitted: 2020-02-13, last modified: 2020-02-14
The design of liquid-crystal diffractive phase plate coronagraphs for ground-based and space-based high-contrast imaging systems is limited by the trade-off between spectral bandwidth and polarization leakage. We demonstrate that by combining phase patterns with a polarization grating (PG) pattern directly followed by one or several separate PGs, we can suppress the polarization leakage terms by additional orders of magnitude by diffracting them out of the beam. \textcolor{black}{Using two PGs composed of a single-layer liquid crystal structure in the lab, we demonstrate a leakage suppression of more than an order of magnitude over a bandwidth of 133 nm centered around 532 nm. At this center wavelength we measure a leakage suppression of three orders of magnitude.} Furthermore, simulations indicate that a combination of two multi-layered liquid-crystal PGs can suppress leakage to $<10^{-5}$ for 1-2.5 $\mu$m and $<10^{-10}$ for 650-800 nm. We introduce multi-grating solutions with three or more gratings that can be designed to have no separation of the two circular polarization states, and offer even deeper suppression of polarization leakage. We present simulations of a triple-grating solution that has $<10^{-10}$ leakage on the first Airy ring from 450 nm to 800 nm. We apply the double-grating concept to the Vector-Vortex coronagraph of charge 4, and demonstrate in the lab that polarization leakage no longer limits the on-axis suppression for ground-based contrast levels. Lastly, we report on the successful installation and first-light results of a double-grating vector Apodizing Phase Plate pupil-plane coronagraph installed at the Large Binocular Telescope. We discuss the implications of these new coronagraph architectures for high-contrast imaging systems on the ground and in space.
[4]  oai:arXiv.org:1909.08317  [pdf] - 2005496
Focal-plane wavefront sensing with the vector Apodizing Phase Plate
Comments: Accepted for publication in Astronomy&Astrophysics. 19 pages, 15 figures
Submitted: 2019-09-18
In this article we show that the vector-Apodizing Phase Plate (vAPP) coronagraph can be designed such that the coronagraphic point spread functions (PSFs) can act as a wavefront sensor to measure and correct the (quasi-)static aberrations, without dedicated wavefront sensing holograms nor modulation by the deformable mirror. The absolute wavefront retrieval is performed with a non-linear algorithm. The focal-plane wavefront sensing (FPWFS) performance of the vAPP and the algorithm are evaluated with numerical simulations, to test various photon and read noise levels, the sensitivity to the 100 lowest Zernike modes and the maximum wavefront error (WFE) that can be accurately estimated in one iteration. We apply these methods to the vAPP within SCExAO, first with the internal source and subsequently on-sky. In idealised simulations we show that for $10^7$ photons the root-mean-square (RMS) WFE can be reduced to $\sim\lambda/1000$, which is 1 nm RMS in the context of the SCExAO system. We find that the maximum WFE that can be corrected in one iteration is $\sim\lambda/8$ RMS or $\sim$200 nm RMS (SCExAO). Furthermore, we demonstrate the SCExAO vAPP capabilities by measuring and controlling the lowest 30 Zernike modes with the internal source and on-sky. On-sky, we report a raw contrast improvement of a factor $\sim$2 between 2 and 4 $\lambda/D$ after 5 iterations of closed-loop correction. When artificially introducing 150 nm RMS WFE, the algorithm corrects it within 5 iterations of closed-loop operation. FPWFS with the vAPP's coronagraphic PSFs is a powerful technique since it integrates coronagraphy and wavefront sensing, eliminating the need for additional probes and thus resulting in a $100\%$ science duty cycle and maximum throughput for the target.
[5]  oai:arXiv.org:1909.02283  [pdf] - 1956025
A snapshot full-Stokes spectropolarimeter for detecting life on Earth
Comments:
Submitted: 2019-09-05
We present the design of a point-and-shoot non-imaging full-Stokes spectropolarimeter dedicated to detecting life on Earth from an orbiting platform like the ISS. We specifically aim to map circular polarization in the spectral features of chlorophyll and other biopigments for our planet as a whole. These non-zero circular polarization signatures are caused by homochirality of the molecular and supramolecular configurations of organic matter, and are considered the most unambiguous biomarker. To achieve a fully solid-state snapshot design, we implement a novel spatial modulation that completely separates the circular and linear polarization channels. The polarization modulator consists of a patterned liquid-crystal quarter-wave plate inside the spectrograph slit, which also constitutes the first optical element of the instrument. This configuration eliminates cross-talk between linear and circular polarization, which is crucial because linear polarization signals are generally much stronger than the circular polarization signals. This leads to a quite unorthodox optical concept for the spectrograph, in which the object and the pupil are switched. We discuss the general design requirements and trade-offs of LSDpol (Life Signature Detection polarimeter), a prototype instrument that is currently under development.
[6]  oai:arXiv.org:1811.08805  [pdf] - 1799075
Simultaneous phase and amplitude aberration sensing with a liquid-crystal vector-Zernike phase mask
Comments: Published in Optics Letters, 4 pages, 5 figures
Submitted: 2018-11-21, last modified: 2018-12-17
We present an enhanced version of the Zernike wavefront sensor, that simultaneously measures phase and amplitude aberrations. The 'vector-Zernike' wavefront sensor consists of a patterned liquid-crystal mask, which imposes $\pm \pi/2$ phase on the point spread function core through the achromatic geometric phase acting with opposite sign on opposite circular polarizations. After splitting circular polarization, the ensuing pupil intensity images are used to reconstruct the phase and the amplitude of the incoming wavefront. We demonstrate reconstruction of the complex wavefront with monochromatic lab measurements and show in simulation the high accuracy and sensitivity over a bandwidth up to $100\%$
[7]  oai:arXiv.org:1811.09775  [pdf] - 1791533
Fully broadband vAPP coronagraphs enabling polarimetric high contrast imaging
Comments: 11 pages, 5 figures, presented at SPIE Astronomical Telescopes and Instrumentation 2018
Submitted: 2018-11-24
We present designs for fully achromatic vector Apodizing Phase Plate (vAPP) coronagraphs, that implement low polarization leakage solutions and achromatic beam-splitting, enabling observations in broadband filters. The vAPP is a pupil plane optic, inducing the phase through the inherently achromatic geometric phase. We discuss various implementations of the broadband vAPP and set requirements on all the components of the broadband vAPP coronagraph to ensure that the leakage terms do not limit a raw contrast of 1E-5. Furthermore, we discuss superachromatic QWPs based of liquid crystals or quartz/MgF2 combinations, and several polarizer choices. As the implementation of the (broadband) vAPP coronagraph is fully based on polarization techniques, it can easily be extended to furnish polarimetry by adding another QWP before the coronagraph optic, which further enhances the contrast between the star and a polarized companion in reflected light. We outline several polarimetric vAPP system designs that could be easily implemented in existing instruments, e.g. SPHERE and SCExAO.
[8]  oai:arXiv.org:1809.08301  [pdf] - 1755190
SCExAO, an instrument with a dual purpose: perform cutting-edge science and develop new technologies
Comments: 12 pages, 9 figures, conference proceedings (SPIE Astronomical telescopes and instrumentation 2018)
Submitted: 2018-09-21
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is an extremely modular high-contrast instrument installed on the Subaru telescope in Hawaii. SCExAO has a dual purpose. Its position in the northern hemisphere on a 8-meter telescope makes it a prime instrument for the detection and characterization of exoplanets and stellar environments over a large portion of the sky. In addition, SCExAO's unique design makes it the ideal instrument to test innovative technologies and algorithms quickly in a laboratory setup and subsequently deploy them on-sky. SCExAO benefits from a first stage of wavefront correction with the facility adaptive optics AO188, and splits the 600-2400 nm spectrum towards a variety of modules, in visible and near infrared, optimized for a large range of science cases. The integral field spectrograph CHARIS, with its J, H or K-band high-resolution mode or its broadband low-resolution mode, makes SCExAO a prime instrument for exoplanet detection and characterization. Here we report on the recent developments and scientific results of the SCExAO instrument. Recent upgrades were performed on a number of modules, like the visible polarimetric module VAMPIRES, the high-performance infrared coronagraphs, various wavefront control algorithms, as well as the real-time controller of AO188. The newest addition is the 20k-pixel Microwave Kinetic Inductance Detector (MKIDS) Exoplanet Camera (MEC) that will allow for previously unexplored science and technology developments. MEC, coupled with novel photon-counting speckle control, brings SCExAO closer to the final design of future high-contrast instruments optimized for Giant Segmented Mirror Telescopes (GSMTs).
[9]  oai:arXiv.org:1808.00751  [pdf] - 1726841
Multiplexed Holographic Aperture Masking with liquid-crystal geometric phase masks
Comments: Presented at the 2018 SPIE Astronomical Telescopes + Instrumentation, Austin, Texas, USA
Submitted: 2018-08-02
Sparse Aperture Masking (SAM) allows for high-contrast imaging at small inner working angles, however the performance is limited by the small throughput and the number of baselines. We present the concept and first lab results of Holographic Aperture Masking (HAM) with extreme liquid-crystal geometric phase patterns. We multiplex subapertures using holographic techniques to combine the same subaperture in multiple non-redundant PSFs in combination with a non-interferometric reference spot. This way arbitrary subaperture combinations and PSF configurations can be realized, giving HAM more uv-coverage, better throughput and improved calibration as compared to SAM, at the cost of detector space.
[10]  oai:arXiv.org:1807.07043  [pdf] - 1718662
Review of high-contrast imaging systems for current and future ground-based and space-based telescopes II. Common path wavefront sensing/control and Coherent Differential Imaging
Comments: 18 pages, 9 figures
Submitted: 2018-07-18
The Optimal Optical Coronagraph (OOC) Workshop held at the Lorentz Center in September 2017 in Leiden, the Netherlands, gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. In this second installment of a series of three papers summarizing the outcomes of the OOC workshop (see also~\citenum{ruane2018,snik2018}), we present an overview of common path wavefront sensing/control and Coherent Differential Imaging techniques, highlight the latest results, and expose their relative strengths and weaknesses. We layout critical milestones for the field with the aim of enhancing future ground/space based high contrast imaging platforms. Techniques like these will help to bridge the daunting contrast gap required to image a terrestrial planet in the zone where it can retain liquid water, in reflected light around a G type star from space.
[11]  oai:arXiv.org:1807.07042  [pdf] - 1782818
Review of high-contrast imaging systems for current and future ground- and space-based telescopes I. Coronagraph design methods and optical performance metrics
Comments: To appear in Proceedings of the SPIE, vol. 10698
Submitted: 2018-07-18
The Optimal Optical Coronagraph (OOC) Workshop at the Lorentz Center in September 2017 in Leiden, the Netherlands gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. In this first installment of a series of three papers summarizing the outcomes of the OOC workshop, we present an overview of design methods and optical performance metrics developed for coronagraph instruments. The design and optimization of coronagraphs for future telescopes has progressed rapidly over the past several years in the context of space mission studies for Exo-C, WFIRST, HabEx, and LUVOIR as well as ground-based telescopes. Design tools have been developed at several institutions to optimize a variety of coronagraph mask types. We aim to give a broad overview of the approaches used, examples of their utility, and provide the optimization tools to the community. Though it is clear that the basic function of coronagraphs is to suppress starlight while maintaining light from off-axis sources, our community lacks a general set of standard performance metrics that apply to both detecting and characterizing exoplanets. The attendees of the OOC workshop agreed that it would benefit our community to clearly define quantities for comparing the performance of coronagraph designs and systems. Therefore, we also present a set of metrics that may be applied to theoretical designs, testbeds, and deployed instruments. We show how these quantities may be used to easily relate the basic properties of the optical instrument to the detection significance of the given point source in the presence of realistic noise.
[12]  oai:arXiv.org:1807.07100  [pdf] - 1719096
Review of high-contrast imaging systems for current and future ground-based and space-based telescopes III. Technology opportunities and pathways
Comments:
Submitted: 2018-07-18
The Optimal Optical CoronagraphWorkshop at the Lorentz Center in September 2017 in Leiden, the Netherlands gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. This contribution is the final part of a series of three papers summarizing the outcomes of the workshop, and presents an overview of novel optical technologies and systems that are implemented or considered for high-contrast imaging instruments on both ground-based and space telescopes. The overall objective of high contrast instruments is to provide direct observations and characterizations of exoplanets at contrast levels as extreme as 10^-10. We list shortcomings of current technologies, and identify opportunities and development paths for new technologies that enable quantum leaps in performance. Specifically, we discuss the design and manufacturing of key components like advanced deformable mirrors and coronagraphic optics, and their amalgamation in "adaptive coronagraph" systems. Moreover, we discuss highly integrated system designs that combine contrast-enhancing techniques and characterization techniques (like high-resolution spectroscopy) while minimizing the overall complexity. Finally, we explore extreme implementations using all-photonics solutions for ground-based telescopes and dedicated huge apertures for space telescopes.
[13]  oai:arXiv.org:1807.05089  [pdf] - 1715413
ERIS: revitalising an adaptive optics instrument for the VLT
Comments: 12 pages, Proc SPIE 10702 "Ground-Based and Airborne Instrumentation for Astronomy VII"
Submitted: 2018-07-13
ERIS is an instrument that will both extend and enhance the fundamental diffraction limited imaging and spectroscopy capability for the VLT. It will replace two instruments that are now being maintained beyond their operational lifetimes, combine their functionality on a single focus, provide a new wavefront sensing module that makes use of the facility Adaptive Optics System, and considerably improve their performance. The instrument will be competitive with respect to JWST in several regimes, and has outstanding potential for studies of the Galactic Center, exoplanets, and high redshift galaxies. ERIS had its final design review in 2017, and is expected to be on sky in 2020. This contribution describes the instrument concept, outlines its expected performance, and highlights where it will most excel.
[14]  oai:arXiv.org:1807.04729  [pdf] - 1714921
Modeling coronagraphic extreme wavefront control systems for high contrast imaging in ground and space telescope missions
Comments: 11 pages, 12 figures, SPIE Astronomical Telescopes and Instrumentation 2018
Submitted: 2018-07-12
The challenges of high contrast imaging (HCI) for detecting exoplanets for both ground and space applications can be met with extreme adaptive optics (ExAO), a high-order adaptive optics system that performs wavefront sensing (WFS) and correction at high speed. We describe two ExAO optical system designs, one each for ground-based telescopes and space-based missions, and examine them using the angular spectrum Fresnel propagation module within the Physical Optics Propagation in Python (POPPY) package. We present an end-to-end (E2E) simulation of the MagAO-X instrument, an ExAO system capable of delivering 6$\times10^{-5}$ visible-light raw contrast for static, noncommon path aberrations without atmosphere. We present a laser guidestar (LGS) companion spacecraft testbed demonstration, which uses a remote beacon to increase the signal available for WFS and control of the primary aperture segments of a future large space telescope, providing on order of a factor of ten factor improvement for relaxing observatory stability requirements. The LGS E2E simulation provides an easily adjustable model to explore parameters, limits, and trade-offs on testbed design and characterization.
[15]  oai:arXiv.org:1807.04381  [pdf] - 1714881
Focal plane wavefront sensing and control strategies for high-contrast imaging on the MagAO-X instrument
Comments: 17 pages, 22 figures
Submitted: 2018-07-11
The Magellan extreme adaptive optics (MagAO-X) instrument is a new extreme adaptive optics (ExAO) system designed for operation in the visible to near-IR which will deliver high contrast-imaging capabilities. The main AO system will be driven by a pyramid wavefront sensor (PyWFS); however, to mitigate the impact of quasi-static and non-common path (NCP) aberrations, focal plane wavefront sensing (FPWFS) in the form of low-order wavefront sensing (LOWFS) and spatial linear dark field control (LDFC) will be employed behind a vector apodizing phase plate (vAPP) coronagraph using rejected starlight at an intermediate focal plane. These techniques will allow for continuous high-contrast imaging performance at the raw contrast level delivered by the vAPP coronagraph 6 x 10^-5. We present simulation results for LOWFS and spatial LDFC with a vAPP coronagraph, as well as laboratory results for both algorithms implemented with a vAPP coronagraph at the University of Arizona Extreme Wavefront Control Lab.
[16]  oai:arXiv.org:1807.04315  [pdf] - 1714869
MagAO-X: project status and first laboratory results
Comments: Presented at SPIE Astronomical Telescopes and Instrumentation 2018
Submitted: 2018-07-11
MagAO-X is an entirely new "extreme" adaptive optics system for the Magellan Clay 6.5 m telescope, funded by the NSF MRI program starting in Sep 2016. The key science goal of MagAO-X is high-contrast imaging of accreting protoplanets at H$\alpha$. With 2040 actuators operating at up to 3630 Hz, MagAO-X will deliver high Strehls (>70%), high resolution (19 mas), and high contrast ($< 1\times10^{-4}$) at H$\alpha$ (656 nm). We present an overview of the MagAO-X system, review the system design, and discuss the current project status.
[17]  oai:arXiv.org:1803.10693  [pdf] - 1657750
The Single-mode Complex Amplitude Refinement (SCAR) coronagraph: II. Lab verification, and toward the characterization of Proxima b
Comments: 9 pages, 11 figures. accepted by A&A
Submitted: 2018-03-28
We present the monochromatic lab verification of the newly developed SCAR coronagraph that combines a phase plate (PP) in the pupil with a microlens-fed single-mode fiber array in the focal plane. The two SCAR designs that have been measured, create respectively a 360 degree and 180 degree dark region from 0.8-2.4 \lambda/D around the star. The 360 SCAR has been designed for a clear aperture and the 180 SCAR has been designed for a realistic aperture with central obscuration and spiders. The 360 SCAR creates a measured stellar null of $2-3 \times 10^{-4}$ , and the 180 SCAR reaches a null of $1 \times 10^{-4}$ . Their monochromatic contrast is maintained within a range of $\pm$ 0.16 \lambda/D peak-to-valley tip-tilt, which shows the robustness against tip-tilt errors. The small inner working angle and tip-tilt stability makes the SCAR coronagraph a very promising technique for an upgrade of current high-contrast instruments to characterize and detect exoplanets in the solar neighborhood.
[18]  oai:arXiv.org:1709.09897  [pdf] - 1589019
Patterned liquid-crystal optics for broadband coronagraphy and wavefront sensing
Comments:
Submitted: 2017-09-28
The direct-write technology for liquid-crystal patterns allows for manufacturing of extreme geometric phase patterned coronagraphs that are inherently broadband, e.g. the vector Apodizing Phase Plate (vAPP). We present on-sky data of a double-grating vAPP operating from 2-5 $\mu m$ with a 360-degree dark hole and a decreased leakage term of $\sim 10^{-4}$. We report a new liquid-crystal design used in a grating-vAPP for SCExAO that operates from 1-2.5$\mu m$. Furthermore, we present wavelength-selective vAPPs that work at specific wavelength ranges and transmit light unapodized at other wavelengths. Lastly, we present geometric phase patterns for advanced implementations of WFS (e.g. Zernike-type) that are enabled only by this liquid-crystal technology.