Dodsworth, George
Normalized to: Dodsworth, G.
3 article(s) in total. 20 co-authors, from 1 to 3 common article(s). Median position in authors list is 4,0.
[1]
oai:arXiv.org:astro-ph/0408449 [pdf] - 66940
Design and construction of the IMACS-IFU, a 2000-element integral field
unit
Submitted: 2004-08-24
The IMACS-IFU is an Integral Field Unit built for the IMACS spectrograph at
the Magellan-I-Telescope at Las Campanas Observatory. It consists of two
rectangular fields of 5 by 7 arcseconds, separated by roughly one arcminute.
With a total number of 2000 spatial elements it is the second largest
fiber-lenslet based IFU worldwide, working in a wavelength range between 400
and 900 nm. Due to the equally sized fields classical background subtraction,
beam switching and shuffling are possible observation techniques. One
particular design challenge was the single, half a metre long curved slit in
combination with a non telecentric output. Besides the construction some
preliminary results are described.
[2]
oai:arXiv.org:astro-ph/0202330 [pdf] - 47824
The GMOS integral field unit: first integral field spectroscopy with an
8m telescope
Allington-Smith, Jeremy;
Murray, Graham;
Content, Robert;
Dodsworth, George;
Davies, Roger;
Miller, Bryan W.;
Turner, James;
Jorgensen, Inger;
Hook, Isobel;
Crampton, David;
Murowinski, Richard
Submitted: 2002-02-18
The Gemini Multiobject Spectrograph (GMOS) installed on the Gemini-North
telescope has a facility for integral field spectroscopy over the wavelength
range 0.4-1.0um. GMOS is converted to this mode by the remote insertion of an
integral field unit (IFU) into the beam in place of the masks used for
multiobject spectroscopy. With the IFU deployed, integral field spectroscopy is
available over a fully-filled contiguous field of 5 x 7 arcsec with a sampling
of 0.2 arcsec. A separate field of half the area, but otherwise identical, is
also provided to aid background subtraction. The IFU contains 1500
lenslet-coupled fibres and is the largest-format fibre-based IFU yet tested on
the sky and the first facility of any type for integral field spectroscopy
employed on an 8/10m telescope. We describe the IFU and present results from
commissioning.
[3]
oai:arXiv.org:astro-ph/9909017 [pdf] - 1469818
Multiple object and integral field near-infrared spectroscopy using
fibers
Haynes, Roger;
Lee, David;
Allington-Smith, Jeremy;
Content, Robert;
Dodsworth, George;
Lewis, Ian;
Sharples, Ray;
Turner, James;
Webster, John;
Done, Christine;
Peletier, Reynier;
Parry, Ian;
Chapman, Scott
Submitted: 1999-09-01
We describe a new system for multiple object spectroscopy and integral field
spectroscopy at near-infrared wavelengths using optical fibers. Both modes of
the SMIRFS instrument have been tested at the UK Infrared Telescope with the
CGS4 infrared spectrograph. The modular system includes a common optical system
to image the fiber slit onto the cold slit inside the CGS4 cryostat. The
multiobject mode consists of 14 interchangeable fused silica or zirconium
fluoride fibers each with a field of 4 arcsec. The integral field mode consists
of 72 fused silica fibers coupled with a lenslet array to give a contiguous
field of 6x4 arcsec with 0.6 arcsec sampling.
We describe the performance of both modes. For the multiobject mode, the
feasibility and desirability of using fluoride fibers to extend the wavelength
range into the K-band is discussed. For the integral field mode, the
performance is compared with theoretical expectation with particular attention
to the effect of Focal Ratio Degradation in the fibers.
These results demonstrate the feasibility of multiobject and integral field
spectroscopy in the near-infrared using lenslet-coupled fiber systems. Although
SMIRFS in an experimental system working with a spectrograph not designed for
this purpose, the throughput and uniformity of response are good. SMIRFS points
the way forward to systems with much larger numbers of elements.